DY-529-001 SHT 004 for Mod.pdf

PDF 1 MB Posted

Attached to
RFQ 1305M221QNMAN0082 for the FY21 Drydock Repairs to the NOAA Ship Oscar Dyson
Solicitation number
1305M221QNMAN0082
Issued by

About this file

This file contains engineering drawings and specifications for modifications to a ship's piping system, as well as information on a related federal solicitation. The engineering drawings depict proposed changes to valves, pipes, and related components. Notes call for removing an existing valve, installing new 3-inch piping and a gate valve with reach rod at frame 34.5, and positioning a new deck operator near an existing sewage valve operator. The related solicitation is RFQ 1305M221QNMAN0082 issued by the National Oceanic and Atmospheric Administration for drydock repairs to the NOAA Ship Oscar Dyson. Interested parties must contact the named Contract Specialist and Contracting Officer to request the reference documents and drawings applicable to the solicitation due to file size limitations.

View the file

Other files

File Type Posted
Amendment 0007.pdf PDF
Attachment I - NOAA Ship Oscar Dyson Intermediate Drydock Detail Specification_REV.3.pdf PDF
REV. 2 Attachment VI - Price Schedule.xlsx XLSX spreadsheet
Amendment 0006.pdf PDF
REV. 1 Attachment VI - Price Schedule.xlsx XLSX spreadsheet
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Attachment I - NOAA Ship Oscar Dyson Intermediate Drydock Detail Specification_REV.2.pdf PDF
DY-671-002 Dive Locker arrangement.pdf PDF
DY-163-FP19 Seachest Diagram Rev 3.pdf PDF
DY-256-FP08 Revision 05 sea water cooling.pdf PDF
DY-524-FP23 Aux Seawater Cooling System Diagram Rev 04.pdf PDF
Amendment 0003.pdf PDF
DY Davit hydraulic hose certificate.pdf PDF
DY-521-FP20 Rev 3 Firemain System.pdf PDF
Attachment I - NOAA Ship Oscar Dyson Intermediate Drydock Detail Specification_REV.1.pdf PDF
DY-085-FA01 Outboard Profile Rev 3.pdf PDF
OD-602-FH60-001 Hull Designated Markings Rev 02 Final.pdf PDF
DY-591-01 Trawling Winch Engineering (047).pdf PDF
DY_528_DY-528-003_RevA_Sht1 THRU 3_N_MODIFICATIONS TO GRAY AND BLACK W.pdf PDF
DY-528-002_RevA MODIFICATIONS TO GRAY AND BLACK WATER SYSTEMS.pdf PDF
Amendment 0002.pdf PDF
DY-085-FZ30 Booklet of General Drawings Rev 0.pdf PDF
DY anchor motor name plate.pdf PDF
Amendment 0001.pdf PDF
1305M221QNMAN0082_REV 1.docx DOCX document
Attachment V - Past Performance Questionnaire.docx DOCX document
Attachment II - Deliverables List.docx DOCX document
1305M221QNMAN0082.pdf PDF
Attachment IV - Past Performance Information Form.pdf PDF
Attachment VI - Price Schedule.xlsx XLSX spreadsheet
Attachment I - NOAA Ship Oscar Dyson Intermediate Drydock Detail Specification.pdf PDF
Attachment VII - Subcontracting Plan Outline.doc DOC document
Attachment III - AIRs Process Document.docx DOCX document
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Jerry.Sheehan Line

Jerry.Sheehan Typewritten Text there is a valve that was added here to make this work needs to be removed too

Jerry.Sheehan Line

Jerry.Sheehan Typewritten Text Dedicated OVBD

Jerry.Sheehan Rectangle

Jerry.Sheehan Line

Jerry.Sheehan Line

Jerry.Sheehan Rectangle

Jerry.Sheehan Line

Pencil

Jerry.Sheehan Pencil

Jerry.Sheehan Rectangle

Jerry.Sheehan Rectangle

Jerry.Sheehan Pencil

Jerry.Sheehan Rectangle

Jerry.Sheehan Pencil

Jerry.Sheehan Pencil

Jerry.Sheehan Rectangle

Jerry.Sheehan Line

Jerry.Sheehan Typewritten Text provide and install new 3" pipe

Jerry.Sheehan Rectangle

Jerry.Sheehan Rectangle

Jerry.Sheehan Pencil

Pencil

Jerry.Sheehan Line

Jerry.Sheehan Line

Jerry.Sheehan Line

Jerry.Sheehan Pencil

Jerry.Sheehan Polygonal Line

Jerry.Sheehan Line

Jerry.Sheehan Typewritten Text new 3" ovbd @FR 34.5 w/ gate valve and reach rod

Jerry.Sheehan Rectangle

Jerry.Sheehan Line

Jerry.Sheehan Typewritten Text HVAC fan and duct not shown on these

Jerry.Sheehan Pencil

Jerry.Sheehan Oval

Jerry.Sheehan Typewritten Text new reach rod install deck operator near existing sewage ovbd operator

Oval