Kongsberg EM 2040 Installatin Manual - April 2015 R.pdf

PDF 7 MB Posted

Attached to
FY21 Henry Bigelow Drydock Repairs
Solicitation number
1305M220QNMAN0190
Issued by

About this file

This is a solicitation for FY21 Henry Bigelow Drydock Repairs. The solicitation is seeking offers for drydock repairs of the NOAA ship Henry Bigelow. The solicitation was issued by the Department of Commerce National Oceanic and Atmospheric Administration. Offerors should submit pricing for haul out, blocking, repairs, painting, and re-blocking services. The solicitation includes a statement of work detailing the required repairs. The closing date for offers is listed as April 15, 2022. Award is expected to be made by May 15, 2022 to the offer representing the best value to the government.

View the file

Other files

File Type Posted
Amendment 0003.pdf PDF
(134)Knuckle Boom Crane_Part2.pdf PDF
(134)Knuckle Boom Crane_Part1.pdf PDF
Bigelow Trawl Winch Drawings.pdf PDF
VideoXpert.pdf PDF
HB FY21 Dry Dock Repair Spec_Rev 1.pdf PDF
(012)Centerboard_Rev1.pdf PDF
HB 124931 Cover.pdf PDF
HB310 FRV40 225 041 010 Generator 3 Phase Synchronous.pdf PDF
HB-085 FA02 General Arrangements.pdf PDF
HB-568 (FRV40-225-008-010) Bow Thruster.pdf PDF
HB-300 FE01 Power One Line.pdf PDF
HB-085 FA04 Docking Drawing.pdf PDF
HB-461 FE93 Transducer Arrangement and Installation(1).pdf PDF
VideoXpert Professional v 3 7 Product Specification.pdf PDF
HB167 FH62 STRL Doors Hatches Manholes Scuttles.pdf PDF
HB-512-5010 Assy Unit 5010 HVAC A_D.pdf PDF
AMC 0001F General Requirements for Contract Repair Work on NOAA Ships.pdf PDF
AMC-0001F General Requirements for Contract Repair Work on NOAA Ships.pdf PDF
HB-100 FH68 BERP _ WERP Key Plan and Details.pdf PDF
Appleton Drawing AMD-2129 REV 0 Jib Pin Assembly.pdf PDF
HB FY20 Liferaft Certificates.pdf PDF
Naval Ships Technical Manual 081 Waterborne Underwater Hull Cleaning of Navy Ships.pdf PDF
HB-160 FH19 Centerboard Bottom Void Scantlings(1).pdf PDF
HB 124622 Sleeve Doubler 3inch NPS.pdf PDF
HB-085 FA01 Outboard Profile.pdf PDF
CC-7137_Plan_001.pdf PDF
Amendment 0002.pdf PDF
Air Box and Generator Pictures (1).pdf PDF
P 1097 19 Henry B. Bigelow LeBus Sleeves.pdf PDF
HB 124930 Casing.pdf PDF
Aft Deck Hatch.pdf PDF
Airmar B17-HP Temp Sensor.pdf PDF
HB-160 FH19 Centerboard Bottom Void Scantlings.pdf PDF
HB-461 FE93 Transducer Arrangement and Installation.pdf PDF
HB-461-002 EM2040 Installation Cable Run Sheets.pdf PDF
Standard - MIL-STD-2199A Glass Reinforced Plastic Covering for Propeller Shafts.pdf PDF
MOC-631-2D Coating Systems for Steel Surfaces.pdf PDF
(005)Line Shaft and Thrust Bearing Manual.pdf PDF
AMC-300-1 Overhaul of Electrical Rotating Machinery.pdf PDF
Amendment 0001.pdf PDF
(006)SternTubeBearing and Shaft Seal Resubmittal.pdf PDF
Furuno FE800 Installation Manual.pdf PDF
HB-461-001 EM2040 MkII 0.4x0.7 Installation.pdf PDF
Airmar Owners Guide _ Installation Instructions - SS577- 33-495-01.pdf PDF
Radial-Rubber-Tile-RBT-Submittal.pdf PDF
MOC-573-2 Overhaul-Repair of Hydraulic Cylinders.pdf PDF
S6900 General Requirement for Electrical-Electronic Items.pdf PDF
MOC-631-3B Underwater Body Ablative Coating System.pdf PDF
(139)Cathelco Antifouling System.pdf PDF
Show 40 more

Latest 50 of 106 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Installation manual

EM 2040

Slim Processing Unit

391932/C April 2015 © Kongsberg Maritime AS

Kongsberg EM 2040 Processing Unit

Installation

Kongsberg Maritime AS www.kongsberg.com

Copyright © Copyright Kongsberg Maritime AS

The information contained in this document remains the sole property of Kongsberg Maritime AS. No part of this document may be copied or reproduced in any form or by any means, and the information contained within it is not to be communicated to a third party, without the prior written consent of Kongsberg Maritime AS. The document, or any part of it, may not be translated to any other language without the written approval from Kongsberg Maritime AS.

Disclaimer Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated, but does not accept liability for any errors or omissions.

Warning The equipment to which this manual applies must only be used for the purpose for which it was designed.

Improper use or maintenance may cause damage to the equipment and/or injury to personnel. All users must be familiar with the contents of the appropriate manuals before attempting to install, operate, maintain or in any other way work on the equipment.

Kongsberg Maritime AS disclaims any responsibility for damage or injury caused by improper installation, use or maintenance of the equipment.

Support information If you require maintenance or repair, contact your local dealer. You can also contact us using the following address: km.hydrographic.support@kongsberg.com. If you need information about our other products, visit http: //www.km.kongsberg.com.

mailto:km.hydrographic.support@kongsberg.com http: //www.km.kongsberg.com

391932/C 3

Table of contents

ABOUT THIS MANUAL

KONGSBERG EM 2040

System Description System diagram System units

Transducer description EM 2040 Processing Unit description Hydrographic Work Station description Ethernet switch Remote Control Unit (K-Rem) description

CABLE LAYOUT AND INTERCONNECTIONS

Read this first Cable plans

Single RX cable plan, Processing Unit Dual RX cable plan, Processing Unit Dual TX cable plan, Processing Unit Single RX with dual swath cable plan, Processing Unit Dual RX with dual swath cable plan, Processing Unit Topside cable plan

List of EM 2040 cables Cable drawings and specifications

RS–232 serial line using three 3 wires and RJ45 connector RS-422 serial line using five wires and RJ45 connector 1PPS (One pulse per second) using a coax cable Remote control Remote Control using K-Rem Not using the remote control option External Synchronization Transmit transducer cable Receive transducer cable TX to RX transducer cable TX to dual RX transducer cable

DRAWING FILE

Processing Unit dimensions Hydrographic Work Station outline dimensions Remote Control Unit (K-REM) outline dimensions

TECHNICAL SPECIFICATIONS

Installation

4 391932/C

Weights and outline dimensions

Kongsberg EM 2040

391932/C 5

About this manual

Observe this general information about the EM 2040 Installation; its purpose and target audience.

Purpose

The purpose of this manual is to provide the information and basic drawings required for the physical installation of the EM 2040.

For more detailed information about the practical use of the EM 2040, refer to the Operator manual and/or the Reference manual.

Target audience

The manual is intended for technical personnel; such as skilled shipyard workers, electricians, qualified engineers and naval architects. It is assumed that you understand the general principles of maritime electronic equipment. You must also be familiar with computer hardware, interface technology and installation of electronic and mechanical products.

We assume that you are familiar with the basic acoustic principles of sound in water, and that you have some experience with multibeam and/or single beam echo sounders in hydrographic applications.

Installation instructions

You must follow the instructions in this manual to ensure optimal performance. As a guide, installation procedures are presented in the order they must be done.

The equipment described in this manual includes the complete system with relevant cabinets. Units provided locally by the customer, installation shipyard or local representative are not described.

The manual also defines the equipment responsibility, and provides applicable instructions for unpacking and storage of units.

About this manual

6 391932/C

Note

You must follow the instructions given in this manual. If not it may affect the warranty.

Kongsberg Maritime AS will accept no responsibility for any damage or injury to the system, vessel or personnel caused by equipment that has been incorrectly installed or maintained, or by drawings, instructions or procedures that have not been prepared by us.

Installation drawings

The customer, or the shipyard contracted to do the installation, must provide relevant detailed vessel specific mechanical drawings.

Note

If required, all drawings provided by the shipyard for the physical installation of the EM 2040 must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. Such approval must be obtained before the installation can begin. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval.

Kongsberg Maritime AS may, on special order, provide assistance to these drawings.

Applicable generic outline dimension and productions drawings are provided in the Drawing file chapter.

On-line information

For information about the EM 2040 and other products from Kongsberg Maritime, visit our website on

• http://www.km.kongsberg.com

Registered trademarks

Observe the registered trademarks that apply.

Windows®, Windows XP®, and Windows® 7 are either registered trademarks, or trademarks of Microsoft Corporation in the United States and/or other countries.

http://www.km.kongsberg.com

391932/C 7

Topics System Description, page 7

System diagram, page 9

System units, page 12

System Description The Kongsberg EM 2040 is an advanced multibeam echo sounder.

Key features include:

• Frequency range from 200 to 400 kHz

• FM chirp allowing much longer range capability (depth and coverage) compared to CW pulses

• Complete roll, pitch and yaw stabilization

• Nearfield focusing on both transmit and receive

• Operates with very short pulse lengths – shortest pulse is 25 microseconds

• The depth rating of the subsea parts is 6000 metres

• IHO-S44 special order compliant

• The EM 2040 has two TX array sizes:

– EM 2040-04 (0.4 degrees at 400 kHz)

– EM 2040-07 (0.7 degrees at 400 kHz)

The EM 2040 multibeam echo sounder is the first system to bring all the advanced features of deep water multibeams to the near bottom sounding environment.

The EM 2040 operating bandwidth is from 200 to 400 kHz, which is a full octave, and this is achieved using the standard transducers. Three standard modes are available. 300 kHz is used for normal operation, giving an optimum balance between high resolution, 8 391932/C depth capability and tolerance of performance deteriorating factors such as water column sediments. 200 kHz is available for meeting requirements to operate at the standard hydrographic single beam frequency, but also to achieve the best depth capability. 400 kHz is provided for inspection work with the utmost resolution.

EM 2040 has the functionality of the lower frequency EM systems, and the small size and weight advantage of the high frequency systems, as well as beamwidth of 0.4 degrees.

FM pulses are used to increase the maximum range capability without sacrificing resolution. Example: 12 ms FM with 1.7 kHz sweep bandwidth compared to 600 us CW pulse (1.7 kHz bandwidth): The resolution is the same since the bandwidth is the same.

The signal to noise ratio in FM mode is increased by 13 dB. This has the same effect as increasing the transmit power level by 13 dB. The range resolution (defined as cT/2) for 600 us CW pulse is 45 cm. A 4.5 ms CW pulse would give the same coverage as 12 ms FM. But this CW pulse would give a range resolution of 200 cm (= 4.5 * 45 cm).

The normally recommended survey frequency is 300 kHz. At this frequency the bandwidth used is more than 75 kHz with three angular sectors running at separate frequencies. With dual swath six frequencies are used (with shortest pulse the total bandwidt used is more than 100 kHz). The minimum pulse length is 70 microseconds in three sectors, and reduced to 35 microseconds using one sector. With 35 μs pulse the range resolution (defined as cτ/2) is 26 mm. For deep waters FM chirp is employed with a bandwidth of 1.7 kHz. This allows a swath width in the order of 600 m and a depth capability of about 400 m in cold ocean waters.

The 200 kHz frequency mode is similar to the 300 kHz mode. It uses the same CW pulse lengths, while the FM chirp pulse length is increased. The range and depth resolution is the same. Normally two sectors are used per swath, but single sector can also be used. At this frequency the absorption in the water is lower than at 300 kHz, resulting in increased swath width and depth capability. In cold ocean waters with FM chirp a swath width of 700 m can be expected and approximately 500 m depth capability.

The 400 kHz frequency mode is intended for high resolution inspection work. Very short transmit pulses and wide receiver bandwidth is used. The operator may select between one and three transmit sectors. With a single RX transducer the coverage limit is 120 degrees (±60 degrees), and with dual RX the coverage is 180 degrees (±90 degrees). The shortest pulse used is 25 μs giving a range resolution less than 20 mm (cτ/2). It is also possible to run dual swath, but not using the shortest pulse length.

The EM 2040 is modular, allowing the user to tailor the beamwidths to the operational requirements, 0.4 by 0.7 degrees or 0.7 by 0.7degrees. The transmit fan is divided into three sectors pinging simultaneously at separate frequencies. This ensures a very strong and beneficial dampening of multibounce interference which on simpler systems often is seen at beam angles from 60 degrees and outwards. The EM 2040 has dual swath capability, allowing a sufficient sounding density alongtrack at a reasonable vessel speed.

EM 2040 also has a scanning mode, i.e. one sector is transmitted at a time, giving the possibility to use the shortest pulse length while still keeping the full swath coverage.

The standard depth rating of the EM 2040 subsea parts is 6000 m. The system is ideal for use on subsea vehicles such as AUVs or ROVs. All analog electronics are contained

391932/C 9 in the transducers, and communication to the topside processing unit is on standard Ethernet. For subsea vehicle use the processing unit may be installed in a pressure rated tank with an inner diameter as small as 230 mm.

For more information about the use of EM 2040 on ROVs and AUVs please see the following application notes (document numbers in brackets):

• High Resolution Bathymetry from ROV Mounted EM 2040 [368428]

• High Resolution Bathymetry from ROV Mounted EM 2040 and HAIN Inertial

Navigation [368429]

System diagram The system diagram identifies the main components of the EM 2040 system, as well as the key connections between these units. Interface capabilities and power cables are not shown.

The standard EM 2040 multibeam echo sounder system consists of one transmit transducer, one receive transducer, one Processing Unit (PU) and one Hydrographic Work Station (computer).

A complete system for seabed mapping will in addition include a transducer mounting plate, a motion sensor, a heading sensor, a sound velocity sensor and a positioning system.

10 391932/C

(cd020104_101_001)

TX

RX

391932/C 11

A Hydrographic Work Station B Interfaces:

• Sound speed sensor

• Tide

• Center depth output

C Processing Unit (PU) D Processing Unit interfaces:

• Positioning systems

• Attitude (roll, pitch and heave)

• Velocity

• Heading

• Clock Processing Unit special interfaces:

• Trigger input/output

• Clock synchronization (1PPS)

E Ethernet F TX transducer cable (Ethernet/power) G RX transducer cable (Ethernet) H TX to RX transducer cable (synchronization/power) I Transmit transducer (TX) J Receive transducer (RX)

12 391932/C

System units The EM 2040 comprises a modular set of electronic units.

Topics Transducer description, page 12

EM 2040 Processing Unit description, page 13

Hydrographic Work Station description, page 13

Ethernet switch, page 13

Remote Control Unit (K-Rem) description, page 14

Transducer description The transducers are the devices that transmit sound into the water and receive the echo. They are fully water tight units intended for many years of trouble-free operation in rough seas.

The EM 2040 consists of separate transducers for transmit and receive.

The system may be delivered in different versions with different transmission beam width. The standard types are:

• EM 2040-04 (0.4 degrees at 400 kHz)

• EM 2040-07 (0.7 degrees at 400 kHz) Note

The red protective coating is an vital part of the transducer. It is very important that neither this coating nor the internal parts of the transducer are damaged during the handling, installation or cleaning. Any holes and/or scratches in the transducer surface will allow water to penetrate the transducer. If a leak occurs, the transducer must be replaced.

A transducer must always be handled as a delicate item. Any wrongful handling may damage the transducer beyond repair.

Observe these rules:

1 Do not activate the transducer when it is out of the water.

2 Do not lift the transducer by the cable.

3 Do not step on the transducer cable.

4 Do not handle the transducer roughly, avoid impacts.

391932/C 13

5 Do not expose the transducer to direct sunlight or excessive heat.

6 Do not use high pressure water, sand blasting or metal tools to clean the transducer face.

7 Do not use strong solvents to clean the transducer face.

8 Do not damage the outer protective skin on the transducer.

EM 2040 Processing Unit description The EM 2040 Processing Unit is provided to process the signals to and from the transducer(s) .

The EM 2040 Processing Unit is an industrial computer using both COTS (commercial off-the-shelf) components and custom made components. The unit is designed and tested for rugged use. The Processing Unit is the central controlling device in the EM multibeam system. It administers the transmittal of pings via the TX unit(s) and reception of data from the RX unit(s).

The processing unit also supplies 48 Vdc power to the transducer(s).

Hydrographic Work Station description The Hydrographic Work Station is a maritime computer. It contains the operational software, and offers the user interface that allows you to control the EM 2040 system.

A dedicated maritime computer is provided with the Kongsberg EM 2040 system. It is set up with all necessary software.

The computer is based on the Microsoft® Windows® 7 operating system.

The computer is normally mounted on the bridge or in a scientific laboratory.

In this publication, the computer is referred to as the Hydrographic Work Station.

Ethernet switch A high capacity Ethernet switch is sometimes required.

If you use more than one Processing Unit in your EM 2040 system, you must use an Ethernet switch to connect each Processing Unit to the Hydrographic Work Station.

A high capacity Ethernet switch (1000BASE-T) is included in the EM 2040 delivery.

14 391932/C

Note

It is very important that high quality Ethernet cables are used everywhere. You must use CAT-5E cables or better. Cables with lower bandwidth capacity will reduce the EM 2040 performance.

1000BASE-T (also known as IEEE 802.3ab) is a standard for gigabit Ethernet over copper wiring. Each 1000BASE-T network segment can be a maximum length of 100 meters (330 feet), and must use Category 5 cable or better (including Cat 5e and Cat 6).

Wikipedia, April 2014

Remote Control Unit (K-Rem) description A dedicated junction box has been designed to provide remote on/off switches with light indication and interface to a remote synchronizing system. The junction box contains a terminal block and four switches with lamps mounted in the front.

Note

The Remote Control Unit is not a standard part of the EM 2040 delivery.

The Remote Control Unit is called K-Rem. It is prepared for remote control and interface to an external synchronization system for the following Kongsberg echo sounders:

• One Sub-bottom profiler (SBP 120 or SBP 300)

• Two EM multibeam echo sounders

• One EA single beam echo sounder

The Remote Control Unit is designed to be mounted in a 19 inch rack, but it is also possible to mount it on a flat surface or in a bulkhead. It is also prepared for mounting on telescopic rails.

391932/C 15

Cable layout and interconnections

Cabling principles, cable plans and drawings, as well as relevant procedures, are provided.

Topics Read this first, page 16

Cable plans, page 17

List of EM 2040 cables, page 25

Cable drawings and specifications, page 27

Cable layout and interconnections

16 391932/C

Read this first Detailed information about cable specifications, termination and connectors is provided.

Unless otherwise specified, all cables are supplied by Kongsberg Maritime as a part of the EM 2040 delivery.

Note

All electronic installations and corresponding wiring must be in accordance with the vessel's national registry and corresponding maritime authority and/or classification society. If no such guidelines exist, we recommend that Det Norske Veritas (DNV GL) Report No. 80-P008 "Guidelines for Installation and Proposal for Test of Equipment" is used as a guide.

Only trained and authorized personnel can install the EM 2040 cables.

Kongsberg Maritime will not accept any responsibility for errors, malfunctions or damage to system or personnel caused by improper wiring.

A detailed drawing for each specific cable is provided. Each drawing provides additional information, and may, when applicable, include minimum specifications, connector terminations and the required number of cores.

Drawings are generally not provided for standard commercial cables.

Cables fall into two categories.

1 System cables: These cables are provided by Kongsberg Maritime as a part of the

EM 2040 delivery.

2 Shipyard cables: These cables must be provided by the shipyard performing the installation, or the shipowner. It is very important that the cables used meet the minimum specifications provided in this manual.

Kongsberg Maritime accepts no responsibility for damage to the system or reduced operational performance caused by improper wiring.

Note

It is very important that all cables are properly installed and correctly terminated.

Observe the relevant regulations and work standards. Always leave enough cable slack close to system units and cabinets to allow for maintenance.

391932/C 17

Cable plans

Topics Single RX cable plan, Processing Unit, page 18

Dual RX cable plan, Processing Unit, page 19

Dual TX cable plan, Processing Unit, page 20

Single RX with dual swath cable plan, Processing Unit, page 21

Dual RX with dual swath cable plan, Processing Unit, page 22

Topside cable plan, page 24

18 391932/C

Single RX cable plan, Processing Unit The processing unit cables include those used to connect the EM 2040 processing unit to AC mains power, and to the transducer. One Ethernet cable is used to connect the processing unit to the Hydrographic Work Station.

C27

(CD020104_100_001)

C28

C34

C29-C32

C10*

C33

C25*

C39*

C38*C37*

C36-1*

TX

RX

C26*

A

B C

A Processing Unit B Transmit Transducer (TX) C Receive Transducer (RX)

Cables identified with an asterisk (*) are provided with the standard EM 2040 delivery.

391932/C 19

Dual RX cable plan, Processing Unit The processing unit cables include those used to connect the EM 2040 processing unit to AC mains power, and to the transducer. One Ethernet cable is used to connect the processing unit to the Hydrographic Work Station.

(cd020104_100_002)

C28

C34

C29-C32

C10*

C33

C25*

C38-1*

RX

C37*

C37*

C38-2*

C36-1*

TX

RX

C CB

C39*

C26*

A C27

C36-2*

A Processing Unit B Transmit Transducer (TX) C Receive Transducer (RX)

20 391932/C

Dual TX cable plan, Processing Unit The processing unit cables include those used to connect the EM 2040 processing unit to AC mains power, and to the transducer. One Ethernet cable is used to connect the processing unit to the Hydrographic Work Station.

C36-2*

(CD020104_100_003)

C28

C34

C29-C32

C10*

C33

C25*

C37-1*

C38-1*

C39-1*

C37-2*

C38-2*

C39-2*

C36-1*

TX

RX

TX

RX

C

C

B

B

A C27

C26*

A Processing Unit B Transmit Transducer (TX) C Receive Transducer (RX)

391932/C 21

Single RX with dual swath cable plan, Processing Unit The processing unit cables include those used to connect the EM 2040 processing unit to AC mains power, and to the transducer. One Ethernet cable is used to connect the processing unit to the Hydrographic Work Station.

C36-2*

C27

(CD020104_100_004)

C28

C34

C29-C32

C10*

C33

C25*

C26*

C38*

C37*

C36-1*

TX

RX

CB

C39*

A

A Processing Unit B Transmit Transducer (TX) C Receive Transducer (RX)

22 391932/C

Dual RX with dual swath cable plan, Processing Unit The processing unit cables include those used to connect the EM 2040 processing units to AC mains power, and to the transducer. Ethernet cables are used to connect the processing units to the Hydrographic Work Station.

C36-2*

C27-1

C27-2

(CD020104_100_005)

C28

C34

C29-C32

C36-7*

C36-6*

C10*

C33

C25-1*

C25-2* C25-3*

C26-2*

C26-1*

C38-2*

C38-1*

C37*

C36-1*

C36-4*

C36-5*

C36-3*

TX

RXRX

C

C39*

DD

A

B

E

391932/C 23

A Processing Unit, master B Processing Unit, slave C Transmit Transducer (TX) D Receive Transducer (RX) E Ethernet switch

24 391932/C

Topside cable plan The topside cables include those used to connect the EM 2040 Hydrographic Work Station and the display to each other, to AC mains power, and to external devices. One Ethernet cable is used to connect the Hydrographic Work Station to the Processing Unit.

C1*

C18

C14

C19 C7*

C8*

C3*

C4*

C5*

C10*

(C D

_0

_0

A

B

C D

A Hydrographic Work Station B Display C Computer keyboard D Computer mouse or trackball

391932/C 25

List of EM 2040 cables A set of cables is required to connect the EM 2040 system units to each other, to the relevant power source(s), and to peripheral devices.

C1 Video cable (VGA, SVGA, HDMI or other format depending on computer and display specifications) C2 Not used, provided for future expansions C3 Computer keyboard cable C4 Computer mouse or trackball cable C5 230/115 Vac 50/60 Hz power C6 Not used, provided for future expansions C7 230/115 Vac 50/60 Hz power C8 Vessel ground C9 Not used, provided for future expansions C10 Ethernet cable between Hydrographic Work Station and Processing Unit

A 4.5 meter long Ethernet cable is provided with the Hydrographic Work Station.

If a longer cable is required, this must be provided by the installation shipyard.

Note

It is very important that a high quality Ethernet cable is used. You must use CAT-5E quality or better. Cables with lower bandwidth capacity will reduce the EM 2040 performance.

C11 Not used, provided for future expansions C12 Not used, provided for future expansions C13 Not used, provided for future expansions C14 Serial interface cables for communication with peripheral devices C15 Not used, provided for future expansions C16 Not used, provided for future expansions C17 Not used, provided for future expansions C18 Ethernet connection cable to ship’s network C19 Ethernet communication using a high quality cable C20 Not used, provided for future expansions C21 Not used, provided for future expansions C22 Not used, provided for future expansions C23 Not used, provided for future expansions

26 391932/C

C24 Not used, provided for future expansions C25 230/115 Vac 50/60 Hz power C26 Vessel ground C27 Remote control to local on/off switch in junction box (Optional)

If Remote control is not used, a termination plug has to be inserted in the Remote control plug on the Processing Unit. This plug is a 9 pin D-SUB supplied with the Processing Unit.

C28 External synchronization C29 Serial interface cables for communication with peripheral devices C30 Serial interface cables for communication with peripheral devices C31 Serial interface cables for communication with peripheral devices C32 Serial interface cables for communication with peripheral devices C33 Ethernet cable from Attitude Velocity sensor

This Ethernet port has to be configured via the Installation parameters menu in SIS. In the SIS installation menu this port is referred to as Ethernet 2.

The Ethernet cable must be provided by the shipyard.

Note

It is very important that a high quality Ethernet cable is used. You must use CAT-5E quality or better. Cables with lower bandwidth capacity will reduce the EM 2040 performance.

C34 1 PPS (one pulse per second) clock synchronization C35 Not used, provided for future expansions C36 Internal Ethernet connections C37 TX Transducer cables C38 RX Transducer cables C39 TX to RX Transducer cables

391932/C 27

Cable drawings and specifications Relevant cables and connections required for the EM 2040 are described in detail.

Topics RS–232 serial line using three 3 wires and RJ45 connector, page 28

RS-422 serial line using five wires and RJ45 connector, page 29

1PPS (One pulse per second) using a coax cable, page 30

Remote control, page 32

Remote Control using K-Rem, page 33

Not using the remote control option, page 34

External Synchronization, page 35

Transmit transducer cable, page 39

Receive transducer cable, page 42

TX to RX transducer cable, page 45

TX to dual RX transducer cable, page 48

28 391932/C

RS–232 serial line using three 3 wires and RJ45 connector An RS-232 serial line connection using three –3– wires and NMEA telegrams is probably the most common way to connect the EM 2040 to external devices.

RX

GROUND 2

TX

TX GROUND

RX

(C D

_0

_0

9 6

6 9

(CD0801_001_002)

Pin 8

Pin 1

(CD0801_001_004)

A Local connection B Connection on peripheral device C Female 9–pin

D-connector D Male 9–pin

D-connector E RJ45 connector

Note that this cable does not support all the signals in the standard RS-232 specification.

Unless otherwise specified, the serial line cable must be provided by the installation shipyard.

Important

When you are using RS-232 serial communication, observe that long runs of unshielded cable will pick up noise easily. This is because the RS-232 signals are not balanced.

Maximum length is typically 60 meters with 2400 bps data rate, but this depends on the cable quality. Always check the cable manufacturers specifications for the actual "shunt capacitance". A common figure is 47.5 pF/m, which gives a maximum cable length of about 50 meters.

Note

Even though a standard exist for RS-232 pin configuration, certain manufacturer may still choose their own connector pins for the various signals used. In order to make the RS-232 connection to your peripheral device work properly, you must always consult the relevant instructions provided by the device manufacturer.

391932/C 29

RS-422 serial line using five wires and RJ45 connector An RS-422 serial line connection can transmit data at rates as high as 10 million bits per second, and may be sent on cables as long as 1500 meters.

GROUND

TXD+ RXD+

RXD+

RXD-

+5V

TXD-

TXD-

RXD-

GROUND

(CD0801_004_002)

TXD+

9 6

6 9

(CD0801_001_002)

Pin 8

Pin 1

(CD0801_001_004)

A Local connection B Connection on peripheral device C Female 9–pin

D-connector D Male 9–pin

D-connector E RJ45 connector

While RS-232 is the most common serial interface for communicating with external devices using the NMEA standard, it only allows for one transmitter and one receiver on each line.

RS-422 provides a mechanism for transmitting data up to 10 Mbits/s. This interface format uses a balanced signal on two wires. This increases both the maximum baud rate and the physical length of the cable, and it reduces the noise. With a high quality cable, you can use RS-422 on distances up to 1500 meters even in noisy environments.

RS-422 is also specified for multi-drop applications. This means that one transmitter can send data to up to 10 receivers.

Note

There are no common standard for RS-422 pin configuration. Any manufacturer may choose their own connector pins for the various signals used. In order to make the RS-422 connection to your peripheral device work properly, you must always consult the relevant instructions provided by the device manufacturer.

Minimum cable requirements

• Conductors: 2 x 5 x 1.5 mm²

• Screen: Overall braided

• Voltage: 60 V

• Maximum outer diameter: Defined by the plugs

30 391932/C

1PPS (One pulse per second) using a coax cable The Processing Unit is equipped with a 1PPS signal input for clock synchronization.

This cable must be provided by the installation shipyard.

1PPS cable A Male BNC connector B Ground C 1PPS signal

1PPS input The 1PPS signal is normally provided by a positioning system.

This is an optically isolated connection that requires approximately 10 mA current. The input power and the resistor value must be adjusted accordingly.

The 1PPS (one pulse per second) signal is connected to the coax connector on the CBMF board. The CBMF board is equipped with an optocoupler at this input. The input series resistor is tuned for a TTL signal (Low level<0.6 V, High level>3.2 V). It can be selected in SIS wether the falling edge or the rising edge of the signal is used by the Processing Unit to synchronize the internal clock.

The 1PPS signal must be minimum 1 microsecond long.

Optical isolated input signals

330 ΩIF

U =1.2VF

Trig In+

Trig In-

RE

CD020104_102_001

A Input from external system B Processing Unit input circuitry

The input current must be approximately 10 mA.

Depending on your input signal additional resistance must be applied to achieve the required input current. Two examples are shown to clarify.

Example:

I =F » 10mA 330 W

4.5V - 1.2V(U )F

391932/C 31

Using +4.5V input signal the input current will be as required (~10mA). No additional resistance required.

Example:

R =1080-330=750E W

R =TOT = =1080 W

10mA

12V - 1.2V(U )F

0.010 10.8

An added resistor of 750Ω and minimum 0.1 Watt must be used.

Note

The input signals must not be negative, i.e. no RS-232 signals can be used for these inputs.

32 391932/C

Remote control The Processing Unit can be switched on/off with a remote switch. This switch is connected to a 9–pin D-connector on the Processing Unit.

STANDBY GND

STANDBY 12 V

ON

(CD0806_701_010)

A B

9 6

6 9

(CD0801_001_002)

A Local connection, male 9–pin D-connector B Connection to remote lamp and on/off switch C Female 9–pin D-connector D Male 9–pin D-connector

Minimum cable requirements

• Conductors: 3 x 0.5 mm²

• Screen: Overall braided

• Voltage: 60 V

• Maximum outer diameter: Defined by the plugs

This cable must be provided by the installation shipyard.

391932/C 33

Remote Control using K-Rem The Processing Unit can be switched on/off with a remote switch. This switch is connected to a 9–pin D-connector on the Processing Unit. A dedicated junction box with on/off switches and light indication has been designed for this purpose (K-Rem).

STANDBY GND

STANDBY 12 V

ON

(CD0806_701_01 1)

A B

STANDBY GND

STANDBY 12 V

ON

9 6

6 9

(CD0801_001_002)

A Local connection, male 9–pin D-connector B Connection at the terminal strip in Remote Control

Unit (K-Rem ) C Female 9–pin D-connector D Male 9–pin D-connector

Minimum cable requirements

• Conductors: 3 x 0.5 mm²

• Screen: Overall braided

• Voltage: 60 V

• Maximum outer diameter: Defined by the plugs

This cable must be provided by the installation shipyard.

34 391932/C

Not using the remote control option The Processing Unit can be switched on/off with a remote switch. If remote control is not used, the enclosed remote control dummy plug has to be inserted in the Remote Control connector in the Processing Unit.

Note

If remote control is not used, the enclosed remote control dummy plug has to be inserted in the Remote Control connector in the Processing Unit. The Processing Unit will not work without this dummy plug.

391932/C 35

External Synchronization The Processing Unit (PU) is equipped with a connection for interface to an external synchronization system.

External synchronization input/output

When multiple echo sounders are employed on a vessel it is essential to optimize the timing of the transmitting of each system. The Kongsberg Maritime K-Sync Synchronizing Unit provides highly configurable timing.

The EM 2040 provides the following synchronization signals:

EM 2040 external synchronization signal characteristics

Signal Type Active

Ready To Transmit (output) Open collector output from isolation unit

High

Trig out (output) Open collector output from isolation unit

Low

Trig in (input) Optical isolated input High

• Ready To Transmit: This is an output signal from the EM 2040 to the synchronization system that goes active when the EM is ready to transmit. The signal is inactive when the echo sounder is transmitting, receiving or processing samples.

• Trig out: The EM 2040 issues a trig out signal. The trig out signal starts before the first transmit pulse and is terminated after the end of the last transmit pulse. For EM 2040 all pulses in one swath are transmitted simultaneously. With dual swath, two pulses are transmitted in sequence. The length of this trig signal is 0.7 ms plus the total TX signal length. For CW pulses the actual TX pulse is 1.5 times the nominal pulse length (because of amplitude tapering).

Reference to the Raw range and angle 78 datagram:

The transmit time for the TX pulse is referred to the centre of the pulse.

The total length of the TX pulse is given in the datagram (Signal length).

The time delay from the leading edge of the trig out pulse to the centre of the first TX pulse is:

– 506 us + 0.5 * signal length.

Example of signal length (200 kHz, Normal sector):

– Short CW: 101 µs

– Medium CW: 288 µs

– Long CW: 865 µs

– Short FM: 3 ms

– Long FM: 12 ms

36 391932/C

• Trig in: The EM 2040 can be triggered by an external signal that will cause the echo sounder to ping. The CBMF board is equipped with an optocoupler at this input. The input series resistor is tuned for a TTL signal (Low level<0.6 V, High level>3.2 V).

There is a delay from the external trig signal is received to the start of the transmit pulse (Trig out). This is caused by signal processing in the TX transducer (pitch stabilization, focus range etc).

The delay is minimum 1.5 ms and depends on the number of transmit pulses per ping (to optimize pitch stabilization). This means that the delay depends on ping mode (frequency), sector mode and swath mode (single/dual).

External Synchronization cable

This connection is used for interface to an external synchronization system (for example K-Sync) used when multiple echo sounders are employed on the same vessel. The external synchronization connector is located on the CBMF board of the processing unit.

This is an optically isolated connection that requires ~10mA current. Input power and resistor value must be adjusted accordingly.

The connector is RJ45 type.

This cable must be provided by the installation shipyard.

(CD0806_701_001)

Pin 8

Pin 1

1 Trig out +

DGND

Trig out -

Trig in +

Trig in -

DGND

RTT +

RTT -

Pin 3 and 6 is used by Kongsberg Maritime only.

Minimum cable requirements

• Conductors: 5 x 2 x 0.5 mm²

• Screen: Screened twisted pairs and overall braided

• Voltage: 60 V

• Maximum outer diameter: Defined by the plugs

391932/C 37

Optical isolated input signals

330 ΩIF

U =1.2VF

Trig In+

Trig In-

RE

CD020104_102_001

A Input from external system B Processing Unit input circuitry

The input current must be approximately 10 mA.

Depending on your input signal additional resistance must be applied to achieve the required input current. Two examples are shown to clarify.

Example:

I =F » 10mA 330 W

4.5V - 1.2V(U )F

Using +4.5V input signal the input current will be as required (~10mA). No additional resistance required.

Example:

R =1080-330=750E W

R =TOT = =1080 W

10mA

12V - 1.2V(U )F

0.010 10.8

An added resistor of 750Ω and minimum 0.1 Watt must be used.

Note

The input signals must not be negative, i.e. no RS-232 signals can be used for these inputs.

Optical isolated output signals

The collector current must be approximately 10 mA. A resistor must be used to tune the collector current depending on your voltage.

38 391932/C

CBMF board RE

External power cd020104_102_002

100 Ω

RTS out+ Trig out+

RTS out- Trig out-

Customer input

Power Resistor value Minimum effect

5 V 0.38 kΩ 0.1 W

12 V 1.08 kΩ 0.15 W

24 V 2.28 kΩ 0.25 W

Note

To avoid ground loops and damage of the EM 2040 electronics caused by external connections, all connections are optically isolated.

391932/C 39

Transmit transducer cable The TX transducer must be connected to the Processing Unit.

(CD0808_100_002)

15000

All measurements in mm.

The drawing is not in scale.

(CD0808_100_001)

ETHERNET 2/3

ETHERNET 2/2

LEMO/1 (+48VDC)

BLACK 18 AWG

WHITE 18 AWG

WHITE/BROWN 24 AWG

BROWN 24 AWG

BLUE 24 AWG

ORANGE 24 AWG

GREEN 24 AWG

GREEN 18 AWG

RED 18 AWG

WHITE/GREEN 24 AWG

WHITE/ORANGE 24 AWG

WHITE/BLUE 24 AWG

ETHERNET 2/1

CHASSIS ETHERNET 1/2

ETHERNET 2/6

Lemo/2 (GND)

ETHERNET 1/2

ETHERNET 1/1

ETHERNET 1/6

ETHERNET 1/3

LEMO/3 (+48VDC)

LEMO/4 (GND)

40 391932/C

1 2 3

8 9 10 11

1 2

Pin 8

Pin 1

(CD0808_100_003)

A LEMO Connector for power in Processing Unit end. Solder side view.

B RJ45 connector for signal in Processing Unit end.

C RJ45 connector for signal in Processing Unit end.

D Underwater connector type DIL13M in transducer end. Face view.

Cable specifications

• SubConn® Power/Ethernet Cable, Type

D/P-P4TP24#/4C18#

• 13 pin with 4 Ethernet TPs, 4 power conductors and

1 screen

• Cable length: 15, 30 and 50 meters

• Cable diameter: 13.97 mm nom.

• Diameter DSLA locking sleeve: 36 mm

• Weight in air: 246 kg/km nom.

• Weight in sea water: 90 kg/km nom.

• Min. bending radius: 130 mm

• Depth rating: 6000 metres

• Screen: Overall braided

• Voltage:

– Power conductor: 600V, max. 4 A

– Twisted pairs: 250V, max. 1 A

391932/C 41

Important

Follow these instructions carefully to ensure correct use of your SubConn® underwater connectors.

• Disconnect the connector by pulling it straight out, not at an angle. Do not pull the cable, and avoid sharp cable bends.

• The connectors must not be exposed to long periods of heat or direct sunlight. If a connector becomes very dry, it should be soaked in fresh water before use

• General cleaning and removal of any accumulated sand or mud on a connector should be performed using spray based contact cleaner (isopropyl alcohol). New grease must be applied again prior to mating.

• Always apply grease before mating:

Greasing and mating above water (dry mate):

– Connectors must be greased with Molykote® 44 Medium before every mating.

– A layer of grease corresponding to minimum 1/10 of socket depth should be applied to the female connector.

– The inner edge of all sockets should be completely covered, and a thin transparent layer of grease left visible on the face of the connector.

– After greasing, fully mate the male and female connector in order to secure optimal distribution of grease on pins and in sockets.

– To confirm that grease has been sufficiently applied, de-mate and check for grease on every male pin. Then re-mate the connector.

Greasing and mating under water (wet mate):

– Connectors must be greased with Molykote® 44 Medium before every mating.

– A layer of grease corresponding to approximately 1/3 of socket depth should be applied to the female connector.

– All sockets should be completely sealed, and transparent layer of grease left visible on the face of the connector.

– After greasing, fully mate the male and female connector and remove any excess grease from the connector joint.

The recommendations from the manufacturer of the underwater connectors may be subject to change without prior notice. Please refer to the manufacturers website for updated information.

• http: //www.macartney.com

Important

Sacrificial anodes should be mounted near the transducer to protect the connectors.

Inspect the anodes regularly, and replace them if needed.

http: //www.macartney.com

42 391932/C

Receive transducer cable The RX transducer must be connected to the Processing Unit.

(CD0808_101_002)

15000

All measurements in mm.

The drawing is not in scale.

B

(CD0808_101_001)

3ETHERNET 4

BLUE 24 AWG

WHITE/BLUE 24 AWG

WHITE/ORANGE 24 AWG

WHITE/GREEN 24 AWG

WHITE/BROWN 24 AWG

BROWN 24 AWG

GREEN 24 AWG

ORANGE 24 AWG

ETHERNET 8

CHASSIS ETHERNET

ETHERNET 7

ETHERNET 5

ETHERNET 2

ETHERNET 1

ETHERNET 6

ETHERNET 3

1 2

Pin 8

Pin 1

(CD0808_101_003)

A RJ45 connector for signal in Processing Unit end.

B Underwater connector type DIL8M in transducer end. Face view.

Cable specifications

• SubConn® Ethernet Cable, Type D-P4TP24#

• 8 pin with 4 Ethernet wisted pairs

• Cable length: 15, 30 and 50 meters

• Cable diameter: 10.4 mm nom.

• Diameter DSLA locking sleeve: 36 mm

• Weight in air: 140 kg/km nom.

• Weight in sea water: 53 kg/km nom.

• Min. bending radius: 100 mm

• Depth rating: 6000 metres

• Screen: Overall braided

391932/C 43

• Voltage:

– Twisted pairs: 250V, max. 1 A

Important

Follow these instructions carefully to ensure correct use of your SubConn® underwater connectors.

• Disconnect the connector by pulling it straight out, not at an angle. Do not pull the cable, and avoid sharp cable bends.

• The connectors must not be exposed to long periods of heat or direct sunlight. If a connector becomes very dry, it should be soaked in fresh water before use

• General cleaning and removal of any accumulated sand or mud on a connector should be performed using spray based contact cleaner (isopropyl alcohol). New grease must be applied again prior to mating.

• Always apply grease before mating:

Greasing and mating above water (dry mate):

– Connectors must be greased with Molykote® 44 Medium before every mating.

– A layer of grease corresponding to minimum 1/10 of socket depth should be applied to the female connector.

– The inner edge of all sockets should be completely covered, and a thin transparent layer of grease left visible on the face of the connector.

– After greasing, fully mate the male and female connector in order to secure optimal distribution of grease on pins and in sockets.

– To confirm that grease has been sufficiently applied, de-mate and check for grease on every male pin. Then re-mate the connector.

Greasing and mating under water (wet mate):

– Connectors must be greased with Molykote® 44 Medium before every mating.

– A layer of grease corresponding to approximately 1/3 of socket depth should be applied to the female connector.

– All sockets should be completely sealed, and transparent layer of grease left visible on the face of the connector.

– After greasing, fully mate the male and female connector and remove any excess grease from the connector joint.

The recommendations from the manufacturer of the underwater connectors may be subject to change without prior notice. Please refer to the manufacturers website for updated information.

• http: //www.macartney.com

44 391932/C

Sacrificial anodes should be mounted near the transducer to protect the connectors.

Inspect the anodes regularly, and replace them if needed.

391932/C 45

TX to RX transducer cable The transmit transducer must be connected to the receive transducer for synchronization and power.

(CD0808_102_002)

All measurements in mm.

The drawing is not in scale.

B

(CD0808_102_001)

BLACK

WHITE

RED

GREEN

48V(+) 48V(+)

SYNC1+ SYNC1+

SYNC1- SYNC1-

48V(GND) 48V(GND)

(CD0808_102_003)

1 2

A Connector in TX end. Face view.

B Connector in RX end. Face view.

Cable specifications

• Power/Sync Cable, Type SOOW 20/5

• Manufactured by MacArtney Underwter Technology

• MCIL8M, MCDLSF connector in TX end

• MCIL4M, MCDLSF connector in TX end

• Cable length: 0.5 or 1.5 meters

• Depth rating: 6000 metres

• Screen: Overall braided

46 391932/C

• Voltage: 250V, max. 1 A Important

Follow these instructions carefully to ensure correct use of your SubConn® underwater connectors.

• Disconnect the connector by pulling it straight out, not at an angle. Do not pull the cable, and avoid sharp cable bends.

• The connectors must not be exposed to long periods of heat or direct sunlight. If a connector becomes very dry, it should be soaked in fresh water before use

• General cleaning and removal of any accumulated sand or mud on a connector should be performed using spray based contact cleaner (isopropyl alcohol). New grease must be applied again prior to mating.

• Always apply grease before mating:

Greasing and mating above water (dry mate):

– Connectors must be greased with Molykote® 44 Medium before every mating.

– A layer of grease corresponding to minimum 1/10 of socket depth should be applied to the female connector.

– The inner edge of all sockets should be completely covered, and a thin transparent layer of grease left visible on the face of the connector.

– After greasing, fully mate the male and female connector in order to secure optimal distribution of grease on pins and in sockets.

– To confirm that grease has been sufficiently applied, de-mate and check for grease on every male pin. Then re-mate the connector.

Greasing and mating under water (wet mate):

– Connectors must be greased with Molykote® 44 Medium before every mating.

– A layer of grease corresponding to approximately 1/3 of socket depth should be applied to the female connector.

– All sockets should be completely sealed, and transparent layer of grease left visible on the face of the connector.

– After greasing, fully mate the male and female connector and remove any excess grease from the connector joint.

The recommendations from the manufacturer of the underwater connectors may be subject to change without prior notice. Please refer to the manufacturers website for updated information.

• http: //www.macartney.com

391932/C 47

Sacrificial anodes should be mounted near the transducer to protect the connectors.

48 391932/C

TX to dual RX transducer cable In a dual RX system, the transmit transducer must be connected to both receive transducers. This connection is for synchronization and power.

(CD0808_103_002)

All measurements in mm.

The drawing is not in scale.

B

C

(CD0808_103_001)

C

48V(+)

SYNC1+

SYNC1-

48V(GND)

48V(+)

SYNC1+

SYNC1-

48V(GND)

48V(+)

48V(+)

SYNC1+

SYNC1+

SYNC1-

SYNC1-

48V(GND)

48V(GND)

BLACK BLACK

BLACK

WHITE WHITE

WHITE

RED RED

RED

GREEN GREEN

GREEN

ORANGE

BLUE

WHITE/BLACK

RED/BLACK

(CD0808_103_003)

1 2

C

A Connector in TX end. Face view.

B Connector in RX end. Face view.

C Connector in RX end. Face view.

Cable specifications

• Power and synchronization cable, type SOOW 20/8 and SOOW

18/4

• Manufactured by MacArtney Underwter Technology

• MCIL8M, MCDLSF connector in TX end

• MCIL4M, MCDLSF connector in RX end

• Cable length: 0.5 + 3.0 meters or 0.5 + 1.0 meters

391932/C 49

• Depth rating: 6000 metres

• Screen: Overall braided

• Voltage: 250V, max. 1 A Important

Follow these instructions carefully to ensure correct use of your SubConn® underwater connectors.

• Disconnect the connector by pulling it straight out, not at an angle. Do not pull the cable, and avoid sharp cable bends.

• The connectors must not be exposed to long periods of heat or direct sunlight. If a connector becomes very dry, it should be soaked in fresh water before use

• General cleaning and removal of any accumulated sand or mud on a connector should be performed using spray based contact cleaner (isopropyl alcohol). New grease must be applied again prior to mating.

• Always apply grease before mating:

Greasing and mating above water (dry mate):

– Connectors must be greased with Molykote® 44 Medium before every mating.

– A layer of grease corresponding to minimum 1/10 of socket depth should be applied to the female connector.

– The inner edge of all sockets should be completely covered, and a thin transparent layer of grease left visible on the face of the connector.

– After greasing, fully mate the male and female connector in order to secure optimal distribution of grease on pins and in sockets.

– To confirm that grease has been sufficiently applied, de-mate and check for grease on every male pin. Then re-mate the connector.

Greasing and mating under water (wet mate):

– Connectors must be greased with Molykote® 44 Medium before every mating.

– A layer of grease corresponding to approximately 1/3 of socket depth should be applied to the female connector.

– All sockets should be completely sealed, and transparent layer of grease left visible on the face of the connector.

– After greasing, fully mate the male and female connector and remove any excess grease from the connector joint.

The recommendations from the manufacturer of the underwater connectors may be subject to change without prior notice. Please refer to the manufacturers website for updated information.

• http: //www.macartney.com

50 391932/C

Sacrificial anodes should be mounted near the transducer to protect the connectors.

391932/C 51

Drawing file

Topics Processing Unit dimensions, page 52

Hydrographic Work Station outline dimensions, page 53

Remote Control Unit (K-REM) outline dimensions, page 55

52 391932/C

Processing Unit dimensions Drawing 385422

All measurements in mm.

The drawing is not in scale.

[385422] Rev .Pro01

CD12_385422_001_001

Rear V iew

Weight: 10.5 kg

482.5

Front V iew

.6

Side V iew

391932/C 53

Hydrographic Work Station outline dimensions Drawing 378828 (2 pages)

54 391932/C

391932/C 55

Remote Control Unit (K-REM) outline dimensions Drawing 370275 (2 pages)

All measurements in mm.

The drawing is not in scale.

[370275] Rev .A

CD12_370275_001_001

U ni t L ab el

4 x M5

Top view

4x M4 (both sides)

Side view

.5

3.

6.

482.6

.8

4x M6 mounting holes

.6

1U

465.9 (19" rack)

Front view

56 391932/C

All measurements in mm.

The drawing is not in scale.

[370275] Rev .A

CD12_ _001_002370275

Ground connection

259.5

Bottom view

4 x PG9 - cable diameter 6.5 - 9 mm

4 x PG13.5 - cable diameter 12 - 15 mm

Top view

391932/C 57

Technical specifications

Topics Weights and outline dimensions, page 57

Weights and outline dimensions The weights and outline dimension characteristics summarize the physical properties of the EM 2040 system.

Note

For more detailed information about the physical dimensions, see the Drawing file.

Transmit transducer - EM 2040–04

• Outline dimensions:

– Length: 727 mm

– Width: 142 mm

– Height: 150 mm

• Weight:

– In air: 45 kg

– In water: 30 kg

• Volume: 15 liters

Transmit transducer - EM 2040–07

• Outline dimensions:

– Length: 407 mm

– Width: 142 mm

– Height: 150 mm

Technical specifications

58 391932/C

• Weight:

– In air: 24 kg

– In water: 16 kg

• Volume: 8.6 liters

Receive transducer

• Outline dimensions:

– Length: 407 mm

– Width: 142 mm

– Height: 136 mm

• Weight:

– In air: 23 kg

– In water: 16 kg

• Volume: 7.8 liters

Transducer mounting plate, EM 2040–04

• Outline…