Furuno FE800 Installation Manual.pdf

PDF 6 MB Posted

Attached to
FY21 Henry Bigelow Drydock Repairs
Solicitation number
1305M220QNMAN0190
Issued by

About this file

This solicitation is for FY21 Henry Bigelow Drydock Repairs for the Department of Commerce National Oceanic and Atmospheric Administration. The solicitation seeks repair services for the NOAA ship Henry Bigelow, including hull preservation and repair, machinery repairs, and alterations and modifications. Offerors should have experience with drydocking and repair of ships of similar size and complexity to the Henry Bigelow. The closing date for proposals is listed as May 15, 2022. Award is expected by June 30, 2022.

View the file

Other files

File Type Posted
Amendment 0003.pdf PDF
(134)Knuckle Boom Crane_Part2.pdf PDF
(134)Knuckle Boom Crane_Part1.pdf PDF
Bigelow Trawl Winch Drawings.pdf PDF
VideoXpert.pdf PDF
HB FY21 Dry Dock Repair Spec_Rev 1.pdf PDF
(012)Centerboard_Rev1.pdf PDF
HB 124931 Cover.pdf PDF
HB310 FRV40 225 041 010 Generator 3 Phase Synchronous.pdf PDF
HB-085 FA02 General Arrangements.pdf PDF
HB-568 (FRV40-225-008-010) Bow Thruster.pdf PDF
HB-300 FE01 Power One Line.pdf PDF
HB-085 FA04 Docking Drawing.pdf PDF
HB-461 FE93 Transducer Arrangement and Installation(1).pdf PDF
VideoXpert Professional v 3 7 Product Specification.pdf PDF
HB167 FH62 STRL Doors Hatches Manholes Scuttles.pdf PDF
HB-512-5010 Assy Unit 5010 HVAC A_D.pdf PDF
AMC 0001F General Requirements for Contract Repair Work on NOAA Ships.pdf PDF
AMC-0001F General Requirements for Contract Repair Work on NOAA Ships.pdf PDF
HB-100 FH68 BERP _ WERP Key Plan and Details.pdf PDF
Appleton Drawing AMD-2129 REV 0 Jib Pin Assembly.pdf PDF
HB FY20 Liferaft Certificates.pdf PDF
Naval Ships Technical Manual 081 Waterborne Underwater Hull Cleaning of Navy Ships.pdf PDF
HB-160 FH19 Centerboard Bottom Void Scantlings(1).pdf PDF
HB 124622 Sleeve Doubler 3inch NPS.pdf PDF
HB-085 FA01 Outboard Profile.pdf PDF
CC-7137_Plan_001.pdf PDF
Amendment 0002.pdf PDF
Air Box and Generator Pictures (1).pdf PDF
P 1097 19 Henry B. Bigelow LeBus Sleeves.pdf PDF
HB 124930 Casing.pdf PDF
Aft Deck Hatch.pdf PDF
Airmar B17-HP Temp Sensor.pdf PDF
HB-160 FH19 Centerboard Bottom Void Scantlings.pdf PDF
HB-461 FE93 Transducer Arrangement and Installation.pdf PDF
HB-461-002 EM2040 Installation Cable Run Sheets.pdf PDF
Standard - MIL-STD-2199A Glass Reinforced Plastic Covering for Propeller Shafts.pdf PDF
MOC-631-2D Coating Systems for Steel Surfaces.pdf PDF
(005)Line Shaft and Thrust Bearing Manual.pdf PDF
AMC-300-1 Overhaul of Electrical Rotating Machinery.pdf PDF
Amendment 0001.pdf PDF
(006)SternTubeBearing and Shaft Seal Resubmittal.pdf PDF
HB-461-001 EM2040 MkII 0.4x0.7 Installation.pdf PDF
Airmar Owners Guide _ Installation Instructions - SS577- 33-495-01.pdf PDF
Radial-Rubber-Tile-RBT-Submittal.pdf PDF
MOC-573-2 Overhaul-Repair of Hydraulic Cylinders.pdf PDF
S6900 General Requirement for Electrical-Electronic Items.pdf PDF
MOC-631-3B Underwater Body Ablative Coating System.pdf PDF
(139)Cathelco Antifouling System.pdf PDF
IEEE.pdf PDF
Show 40 more

Latest 50 of 106 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

www.furuno.com All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Installation Manual

NAVIGATIONAL ECHO SOUNDER

Model FE-800

SAFETY INSTRUCTIONS ................................................................................................ i SYSTEM CONFIGURATION ........................................................................................... ii EQUIPMENT LISTS........................................................................................................ iii

1. MOUNTING

1.1 Display Unit

1.2 Transceiver Unit

1.3 Transducer

1.4 Matching Box

1.5 Gate Valve GV-50B-6B, GV-200B-8B (option)

2. WIRING

2.1 Wiring

2.2 Cable Fabrication

2.3 Display Unit

2.4 Transceiver Unit

2.5 Matching Box

2.6 Bridge Alert Management (BAM) Connection

2.7 Junction Box (Option)

3. ADJUSTMENTS

3.1 Service Menu

3.2 How to Set the Time

3.3 How to Set the Frequency

3.4 How to Set the Port

3.5 How to Set the Ethernet

APPENDIX 1 JIS CABLE GUIDE .............................................................................AP-1 APPENDIX 2 DIGITAL INTERFACE ........................................................................AP-2

PACKING LISTS ......................................................................................................... A-1

OUTLINE DRAWINGS ................................................................................................ D-1

INTERCONNECTION DIAGRAM ................................................................................ S-1 i

SAFETY INSTRUCTIONS

Warning, Caution

The installer must read the applicable safety instructions before attempting to install the equipment.

WARNING

CAUTION

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury.

Prohibitive Action Mandatory Action

WARNING CAUTION

Do not open the equipment unless totally familiar with electrical circuits and service manual.

Only qualified personnel should work inside the equipment.

Turn off the power at the switchboard before beginning the installation.

Fire or electrical shock can result if the power is left on.

Do not install the equipment where it may get wet from rain or water splash.

Water in the equipment can result in fire,electrical shock or equipment damage.

Be sure no water leaks in at the transducer mounting location.

Water leakage can sink the vessel. Also confirm that the transducer will not loosen by ship's vibration. The installer of the equipment is solely responsible for the proper installation of the equipment.

FURUNO will assume no responsibility for any damage associated with improper installation.

Be sure that the power supply is compatible with the voltage rating of the equipment.

Connection of an incorrect power supply can cause fire or equipment damage. The voltage rating of the equipment appears on the label above the power connector.

Observe the following compass safe distances to prevent deviation of a magnetic compass:

Standard compass

Steering compass

0.75 m 0.50 mDisplay unit

FE-8010

Transceiver unit FE-8020 1.50 m 0.95 m

Matching box

MB-502

0.80 m 0.50 m

Matching box

MB-504

0.65 m 0.40 m

Securely attach protective earth to the ship's body.

The protective earth is required to prevent electrical shock.

When handling the transducer cable, keep in mind following points:

- Keep the cable away from oil and fuel.

- Keep the cable away from the place where it may be damaged during the installation.

- Do not paint the cable.

- The sheath of the transducer cable is made of chlorophrene rubber (or vinyl chloride). Therefore, do not paint the sheath with organic liquid (such as toluene) since it may harm the sheath.

Use the proper fuse.

A wrong fuse can cause fire or serious damage to the equipment.

Turn off the POWER switch when the transducer is not in water.

Operating the transducer when it is not in water may damage the transducer.

ii

SYSTEM CONFIGURATION

LANLAN

TRANSCEIVER UNIT

FE-8020

Power

Signal

Printer

PP-505-FE

DISPLAY UNIT

FE-8010

Remote Display RD-20 or RD-50

Remote Display RD-20 or RD-50

BAM

Network Device or PC

Power

Contact signal

Ship’s Mains

100-230 VAC

JUNCTION

BOX

JISF8821-1MO

JUNCTION

BOX

JISF8821-1MO

Transceiver Unit FE-8020 (No.2)

MATCHING BOX

MB-504

TRANSDUCER

200B-8B

TRANSDUCER

50B-6B

MATCHING BOX

MB-502

Equipment category

Display unit

Transceiver unit protected from weather protected from weather

Navigator

BAM or IF-2503

: Standard supply

: Optional or local supply

EQUIPMENT LISTS

Standard Supply

Optional Supply

Name Type Code No. Qty Remarks Display Unit FE-8010 — 1 Transceiver Unit

FE-8020 — 1

Matching Box

MB-502 — 1 Select one.

For 50B-6B MB-504 — 1 For 200B-8B

Transducer 50B-6B — 1 Select one.

w/ 15/30/50 m cable 200B-8B — 1 w/ 15/30/50 m cable

Transducer Case

TTF-5600 — 1 For 50B-6B TTF-2000 — 1 For 200B-8B

Installation Materials

CP12-01101 001-273-980 1 For display unit.

Self-tapping screw, 4 pcs. (Type: 5×20 SUS304, Code No.: 000-171-997-10)

CP12-01201 001-274-800 1 For transceiver unit CP12-01201 001-288-000 1 Copper strap, 1 pc. (Type: WEA-

1004-0, Code No.: 500-310-040-10) CP02-08802 001-106-500 1 For Transducer Case TTF-5600 CP02-08801 001-106-490 1 For Transducer Case TTF-2000

Accessories FP12-00801 001-273-990 1 For display unit Spare Parts SP12-00801 001-274-790 1 Fuse, 2 pcs. (Type: FGMB 250V 2A

PBF, Code No.: 000-157-497-10), for transceiver unit

Name Type Code No. Remarks Transceiver Unit FE-8020 — Junction Box JISF8821-1MO

BTB15C3

Matching Box MB-502 — For 50B-6B MB-504 — For 200B-8B

Transducer 50B-6B — w/15/30/50 m cable 200B-8B — w/15/30/50 m cable

Transducer Case TTF-5600 — For 50B-6B TTF-2000 — For 200B-8B

Transducer Tank TTF-5001 — For 50B-6B TTF-2001 — For 200B-8B TTF-5002 — For 50B-6B (w/Flange) TTF-2002 — For 200B-8B (w/Flange) TK-052 — w/Flange TK-085 — w/Flange

Gate Valve GV-50B-6B — w/ Installation Materials CP02- 07601 (code no.: 002-891-620)

GV-200B-8B —

Bracket Assembly w/Knobs

OP26-8 000-016-313 For display unit, see page 3 for details.

iii

EQUIPMENT LISTS

Note: Windows is a registered trademark or trademark of the Microsoft Corporation of the USA and other countries.

Front Fixing Panel OP26-28 001-247-250 For display unit, change cutout from octagon to square. (See page 2 for details.)

Front Fixing Panel OP12-1 001-273-660 For display unit, replace FE- 680 or FE-680T. (See page 3 for details.)

Printer PP-505-FE 000-055-892 Data Recording Software for PC

OP12-2 001-273-650 For Windows 7/8 (PC: local supply)

Installation Materials

CP12-01101(BOX) 001-273-760 For display unit CP12-01201(BOX) 001-273-790 For transceiver unit CP24-02900(10M) 001-208-050 For transceiver unit, LAN cableCP24-02910(20M) 001-208-060

CP24-02920(30M) 001-208-070

Accessories FP12-00801(BOX) 001-273-770 For display unit Spare Parts SP12-00801(BOX) 001-273-780 For transceiver unit Operator’s Manual

(CD-ROM)

FE-800 O/M *CD-ROM* —

Interface Unit IF-2503 —

Name Type Code No. Remarks iv

1. MOUNTING

1.1 Display Unit

1.1.1 Installation consideration

The display unit can be installed on a desktop or flush mounted in a console or panel.

When selecting a mounting location, keep in mind the following points:

• The nominal viewing distance for the display unit is 0.9 m. Select a suitable mount-ing location considering that distance.

• Locate the unit away from exhaust pipes and vents.

• Select an installation location that is well ventilated.

• Locate the unit where shock and vibration are minimal.

• Locate the unit away from equipment which generates the electromagnetic fields like a motor or generator.

• Allow enough maintenance space at the sides and rear of the unit and leave enough slack in cables to facilitate maintenance and servicing.

• Observe the compass safe distances in the "SAFETY INSTRUCTIONS" (on page i) to prevent interference to a magnetic compass.

• For flush mounting in a panel, the mounting surface must be flat. Do not install the unit on an uneven surface.

1.1.2 How to remove the cover

While pressing the center of the cover with your thumbs as shown in the right figure, pull the cover towards you to remove it.

NOTICE

Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment.

Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors.

1.1.3 Flush mounting

For details, see the outline diagrams at the back of this manual.

For octagonal cutout

1. Make an octagonal cutout in the mounting location as shown in the illustration be-low.

2. Make four pilot holes for self-tapping screws in the location indicated in the illus-tration below.

3. Set the display unit to the cutout and fasten the display unit with four self-tapping screws (φ5×20).

4. Set a cosmetic cap to each fixing hole on the front panel. (See "How to set the cosmetic cap" on page 4.)

For square cutout

You can install the display unit in a square cutout using with the optional kit OP26-28.

Front Fixing Panel OP26-28 (code no.: 001-247-250)

1. Make a square cutout (239±1 mm) in the mounting location referring to the outline drawing at the back of the manual.

2. Make four pilot holes for self-tapping screws in the location.

3. Attach the front fixing panel to the display unit from the front side with binding screws (M5×16).

4. Set the display unit to the cutout and fasten the display unit with four self-tapping screws (φ5×20) from the front side.

5. Set a cosmetic cap to each fixing hole on the front panel. (See "How to set the cosmetic cap" on page 4.)

No. Name Type Code no. Qty Remarks 1 Self-tapping screw 5×20 SUS304 000-163-915-10 4 2 Front fixing panel 26-003-1701 100-382-080-10 1 3 Binding screw M5×16 SUSU304 000-163-898-10 4 4 Manual C72-01302-* —

78 (3.07")12 (0.47") 240 (9.45")

(9 .4

5 "

Fixing hole (4-ø6)

223±0.5 (8.78")

0.

(8

.7 8"

) 18 (0.71")

18 (0.71")Pilot hole (4 places)

Cutout

18 (0.71")

For replacement of FE-680/FE-680T

You can replace FE-680/FE-680T with FE-800, using the optional Front Fixing Panel kit OP12-1.

Front Fixing Panel OP12-1 (code no.: 001-273-660)

1. Remove FE-680/FE-680T from mounting location.

2. Attach the front fixing panel to the display unit from the front side with binding head screws (M5×12).

3. Set the display unit to the original cutout then fasten the display unit as shown in the right figure.

1.1.4 Desktop mounting

The display unit can be mounted on a desktop using the optional hanger. See the out-line drawing for details.

Bracket Assembly with Knobs (Type: OP26-8, Code no.: 000-016-313-00)

1. Remove the hanger mounting plate from the hanger assembly.

2. Fasten the hanger mounting plate to the display unit from the left side and right side with four bind-ing head screws (M5×12).

No. Name Type Code no. Qty Remarks 1 Binding head screw M5×12 SUS304 000-171-999-10 4 2 Front fixing panel 12-005-1131-0 100-391-660-10 1 3 Hexagonal head bolt M8×35 SUS304 000-164-170-10 4 4 Spring washer M8 SUS304 000-167-410-10 4 5 Flat washer M8 SUS304 000-167-464-10 8 6 Hexagonal nut M8 SUS304 000-167-479-10 8

Name Type Code No. Qty Self-tapping screw 5×20 000-171-997-10 4 Binding head screw M5×12 000-171-999-10 4 Hanger assy. OP26-8-1 001-081-920-00 1

Mounting plate

FE-8010

w/Front fixing panel

Hex nutHex nut Spring washerSpring washer

Flat washerFlat washer

Hex boltHex bolt

Rear side of FE-8010

Hanger mounting plate (left side) Binding head screw (M5×12)

3. Make a four pilot holes for self-tapping screws (φ5×20) in the mounting location.

4. Fix the hanger to the mounting location with four self-tapping screws (φ5×20).

5. Insert a washer to each knob (right and left) and fix the washer to the display unit loosely.

6. Set the display unit to the hanger.

7. Tighten the knobs to fasten the hanger to the display unit.

8. Set a cosmetic cap to each fixing hole on the front panel. (See below "How to set the cosmetic cap".)

How to set the cosmetic cap

Set a cosmetic cap to each fixing hole on the front panel as shown in the figure below.

(1 0.

288 ± 5 (11.34”)

240 (9.45”)

(1 0.

51 ± 5 (2.01”) 149 (5.87”)

91 (3.58”)

(9 .4

5”

Fixing hole (4-ø7)190 ± 0.5 (7.48”)

.5

(2 .9

5”

(1

.5 7”

Set cosmetic cap to hole so cap is flush with panel.

1.2 Transceiver Unit

1.2.1 Installation considerations

Keep in mind the following points when selecting a location.

• Locate the transceiver unit away from heat sources because of heat that can build up inside the cabinet.

• Locate the unit where shock and vibration are minimal.

• Locate the transceiver unit away from places subject to water splash and rain.

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

• Be sure to connect the copper strap (between the earth terminal on the chassis and the ship’s earth).

• A magnetic compass will be affected if the transceiver unit is placed too close to the magnetic compass. Observe the compass safe distances in the "SAFETY IN- STRUCTIONS" (on page i) to prevent interference to a magnetic compass.

• Install the transceiver unit on the floor, or on a bulkhead.

1.2.2 How to install the transceiver unit

The transceiver unit can be mounted on a desktop or a bulkhead. See the outline drawing for details.

Note 1: For desktop mounting, install the unit where it won’t get wet from rain or water splash.

Note 2: For bulkhead mounting, fix the unit so that the notches on it are facing the deck.

1. Make four pilot holes for hexagonal nuts (M8×25) in the mounting location.

2. Fasten the transceiver unit as shown below.

1.3 Transducer

The installation of the transducer and the tank should be accomplished by a dockyard referring to the installation drawings at the back of this manual. An example of trans-ducer installation method is also shown in paragraph 1.3.2.

Note: Discussions should be taken place and agreement reached with the dockyard for sufficient reinforcement and watertightness of the hull to comply with the regula-tions concerned.

Notches (Face the deck for bulkhead mounting.)

Bolt Flat washer

Spring washer

Nut

Pilot hole (M8×25)

Mounting location

1.3.1 Installation considerations

The most important matter is where the transducer is installed. To decide the location of the transducer, the following points should be taken into account.

• The position should be free from aeration possibly occurring beneath the hull and also not affected by engine and propeller noise.

• It is known that air bubble streams start approximately from a quarter length of the ship’s length from the bow, and spreads over the hull bottom approximately to three quarters. Air bubble streams vary in form and intensity according to ship's speed, draught, trim, shape of bow and hull, as well as sea state.

• Sitting near obstructions such as the forward propeller, bow thruster, water intake pipes and speed log signal should be avoided.

• Select a place giving minimum mechanical vibration.

• Do not lay the transducer cable near or in parallel with other electric cables.

1.3.2 How to install the transducer (Example for TTF-5600)

The transducer tank should be welded to the hull so as to be flush with the hull bottom.

This should be done by the shipyard before installing the transducer.

Note: Be sure to remove the transducer and rubber gasket prior to welding the trans-ducer tank to the hull. Further, re-attach the fixing flange temporarily, to avoid heat dis-tortion when welding.

1. Feed the transducer cable through the cable gland.

2. Apply sealing tape to the threads of the gland nut for watertightness.

3. Pass the cable thru the gasket, washer and gland nut.

4. Fix the transducer to the tank with the transducer fixing flange.

5. Coat the thread of gland nut with silicone grease.

6. Tighten the gland nut.

7. It is recommended to enclose the transducer cable in a conduit pipe for water-proofing and electrical shielding as well as for protecting the cable from mechan-ical damage. The conduit pipe should be fixed to the flange on the transducer tank. The pipe should be of such a length to clear the water level when the ship is fully loaded. The pipe end should be finished with filling compound. It is recom-

Washer (Flat face: Upside)

Gasket

Fixing flange

Gland nut mended to fill the pipe with sand between the transducer and the junction box (or matching box). This will protect the transducer from vibration and damage.

1.4 Matching Box

The matching box should be selected based on the transducer type; and should be installed between the transceiver unit and the transducer unit. (A second matching box is optional.)

• 50B-6B transducer: MB-502

• 200B-8B transducer: MB-504

1.4.1 Installation considerations

The matching box can withstand minor water splash, however, locate the unit away from places subject to direct water and rain.

1.4.2 How to install the matching Box

Fasten the matching box with four self-tapping screws (φ6×20, local supply). Observe the compass safe distances in the "SAFETY INSTRUCTIONS" (on page i) to prevent interference to a magnetic compass.

Transducer

Reinforcement Reinforcement

Fixing flange

Washer Rubber gasket

Gland nut

Transducer Tank

Hex. head bolt (M6×25) and spring washer

Damper (TTF-2000/TK-052/085 only)

Hull plateHull plate Hull plateHull plate

1.5 Gate Valve GV-50B-6B, GV-200B-8B (option)

Assemble the gate valve as shown below. Refer to the drawing at the end of this man-ual.

1. Disassemble the gate valve as-sembled tentatively: spacer, gasket1, gate valve, gasket 2, seachest cap and shaft assem-bly.

When assembling the gate valve, use original washers, bolts and nuts. Keep the bot-tom of the seachest cap and the shaft free of dust and be careful not to damage them.

2. Weld the spacer to the hull bot-tom.

The hull side of the spacer should be flush with the hull bottom. Be careful not to dam-age the side fixed to the gate valve.

3. Clean the side of the spacer to be fixed to the gate valve.

4. Grease (supplied) both sides of the gasket 1 and the inner side of the spacer. Place the gasket 1 onto the spacer.

5. Clean the flange side of the gate valve, and place it on the gasket 1. The scale side of the gate valve should be up.

6. Fix stud bolts of the spacer with washers and bolts loosely.

7. Keep seachest cap and shaft assembly free of dirt and dust.

8. Grease (supplied) both sides of the gasket 2 and place it onto the gate valve.

9. Place seachest cap and shaft assembly onto the gasket 2.

10. Fix the assembly with bolts, nuts and washers loosely.

11. Unscrew nuts from flange 2, and confirm that shaft can be moved up and down smoothly by hand.

You will feel some resistance because of the O-ring (P135).

12. Fasten the gate valve with bolts, nuts and washers above and below.

Note: When installing a transducer, do it be-fore step 7 or after removing the seachest cap and the shaft assembly.

Spacer

Nut Washer

Gate Valve

Nut

Washer

Bolt

Gasket 2

Seachest cap

Shaft

O-ring (P135)

Scale

Gasket 1

Stud bolt

Bolt M6×25

Shaft Flange

O-ring Spring washer

Damper

Transducer case Transducer

Flange 2

Nut

Washer

2. WIRING

2.1 Wiring

The illustration below shows the cables to use to connect the units of the system. See the interconnection diagram at the back of the manual for details. The cables shown with dashed line are local supply.

DPYC-1.5

(Power)

Display Unit

FE-8010

TTYCSLA-4

(Signal)

TTYCSLA-4 RD-20 or RD-50

TTYCSLA-4 Navigator

TTYCSLA-4 FE-8020 (No.2)

TTYCSLA-1 Navigator

TTYCSLA-1 Navigator

TTYCSLA-4 BAM or IF-2503

TTYCSLA-1 POWER FAIL

DTI-C5E350 VCV Network Device or PC

DPYC-1.5 Ship’s Mains

Junction Box

JISF8821-1MO

DPYCYSLA-2.5

Printer

PP-505-FE

TPYCSLA-1.5

DPYCYSLA-2.5

Transceiver unit

FE-8020

(No. 1)

Matching Box MB-502 (For 50B-6B)/ MB-504 (For 200B-8B)

Transducer 50B-6B/200B-8B

2.2 Cable Fabrication

TTYCSLA-1/TTYCSLA-4

<Side: Display unit>

<Side: Transceiver unit>

DPYC-1.5

<Side: Display unit>

<Side: Transceiver unit>

Drain wireDrain wire

CoreCore

Vinyl tapeVinyl tape

Clamp here.Clamp here.

Armor

Wrap the drain wire around the sheath.

SheathSheath more than 50

Vinyl tapeVinyl tape

Vinyl tapeVinyl tape

TTYCSLA-4

Cable Core

2TTYCSLA-1

CoreCoreArmor

Clamp here.Clamp here. Crimp-on lug

Pass heat shrink tubing (local supply) onto the drain wire.

Drain wireDrain wire150150

15 5

Vinyl tapeVinyl tape Crimp-on lug

CoreCoreArmor

Clamp here.Clamp here.

SheathSheath more than 50

L1 L2

Vinyl tapeVinyl tape

15 5

Crimp-on lug

CoreCoreArmor Length of “L1” (mm)

Transceiver unit (CN1)

Cable side

Length of “L2” (mm)

9Transceiver unit (CN4)

Clamp here.Clamp here.

*: For CN1, attach the crimp-on lug.

TPYCSLA-1.5

<Side: Display unit>

DPYCYSLA-2.5

<Side: Transceiver unit>

<Side: Matching box>

2RNCT-SB 2Cx1.4

<Side: Matching box>

Drain wireDrain wire

CoreCore

Vinyl tapeVinyl tape

Clamp here.Clamp here.

Armor

Wrap the drain wire around the sheath.

SheathSheath more than 50

Vinyl tapeVinyl tape

Drain wireDrain wire CoreCoreSheathSheath Armor more than 50

150 6

Clamp here.Clamp here.

15 5

Crimp-on lug

Pass heat shrink tubing (local supply) onto the drain wire.

Vinyl tapeVinyl tape

Drain wireDrain wire CoreCoreOuter sheath Outer sheath more than 50

150 6

Clamp here.Clamp here. 15 5 Crimp-on lug

Pass heat shrink tubing (local supply) onto the drain wire.Vinyl tapeVinyl tape

Armor (Suitable length) Armor (Suitable length)

Inner sheathInner sheath

CoreCoreSheathSheath

Clamp here.Clamp here.

Vinyl tapeVinyl tape

Crimp-on lug

Unwind shield.

Twist shield.

DTI-C5E350 VCV

Note: Do not use an optical fiber cable.

How to fabricate the LAN connector

Armor

Outer vinyl sheath Outer vinyl sheath

Inner vinyl sheathInner vinyl sheath more than 50

Vinyl tapeVinyl tape Modular plugModular plug Clamp here.Clamp here.

Cable jacketCable jacket

Using the special crimping tool MPT5-8 (PANDUIT CORP.), crimp the modular plug.

Finally, check the plug visually.

Expose inner vinyl sheath.

1 WHT/GRN

2 GRN

3 WHT/ORG

4 BLU

5 WHT/BLE

6 ORG

7 WHT/BRN

8 BRN

WHT/ORG 1

ORG 2

WHT/GRN 3

BLU 4

WHT/BLE 5

GRN 6

WHT/BRN 7

BRN 8

[Cross-over cable]

1 WHT/ORG

2 ORG

3 WHT/GRN

4 BLU

5 WHT/BLE

6 GRN

7 WHT/BRN

8 BRN

WHT/ORG 1

ORG 2

WHT/GRN 3

BLU 4

WHT/BLE 5

GRN 6

WHT/BRN 7

BRN 8

[Straight cable]

Remove the outer sheath by approx 25 mm. Be careful not to damage inner shield and cores.

Fold back the shield, wrap it onto the outer sheath and cut it, leaving 9 mm.

1 2 3 25 mm approx. 9 mm

4 5 6 approx. 9 mm approx. 11 mm Drain wire

Fold back drain wire and cut it, leaving 9 mm.

Straighten and flatten the core in order and cut them, leaving 11 mm.

Insert the cable into the modular plug so that the folded part of the shield enters the modular plug. The drain wire must be on the tab side of the jack.

1 8

Modular plug

2.3 Display Unit

Remove four screws to remove the rear cable cover. Remove the cable clamps to con-nect the cables.

Rear view of the display unit

Three cables are connected to the display unit. After connecting cables, close the ca-ble cover.

• Cable for the transceiver unit (DPYC-1.5): To CN1

• Cable for the transceiver unit (TTYCSLA-4): To CN2 Connect the ground wire with the wing nut as shown the below.

• Cable from the printer (TPYCSLA-1.5): To CN3

Grounding

Shorten the ground wire as much as possible.

Note 1: Ground the equipment to prevent mutu-al interference.

Note 2: Use “closed-type” lugs to make the ground connection at the display unit and the matching box. Do not use “open-type” lugs when a crimp-on lugs are supplied locally.

2.4 Transceiver Unit

1. Remove six screws to open the cover of the transceiver unit.

Cable coverCable cover

DISP board 12P1004

DISP board 12P1004

Cable clampCable clamp

From printerFrom printer

From Transceiver unit (For signal) From Transceiver unit (For signal)

From Transceiver unit (For power) From Transceiver unit (For power)

CN3 CN2 CN1

(Rear view)

2. Loosen four screws to open the fil-ter cover.

3. Loosen or remove the cable entrance assembly as shown below.

To connect CN8, CN10, CN12 and CN13, remove the cap spacers from the cable clamp.

4. There is a plastic sheet on the inside of the cable entrance. Before passing the cables, tear the plastic sheet by hand to pass the cables.

5. Connect cables as shown below.

Top and front views of the Transceiver unit

Filter cover

Remove two screws.Remove four screws.Loosen two screws.

Cap spacer

Front view

Top view

CN4

CN2 CN3

CN6

CN9

CN12

CN8

CN11

CN14

CN5

CN7

CN10

CN13

CN1

Transceiver unit

6. Set the DIP switch on MAIN board 12P1000 referring to the descriptions below.

Cable entrance No. Cable Connector

(on 12P1000) Grounding

1: For ship’s mains DPYC-1.5 CN1

2: For display unit (power) CN4 3: LAN for INS or PC (Recording software)

DTI-C5E350

VCV (φ13.5 mm) Note: Do not use other cable.

CN5

4: For external equipment TTYCSLA-1 CN6, CN7, CN9

Needed

5: For display unit (signal) TTYCSLA-4 CN8 6: For matching box DPYCYSLA-2.5 CN2, CN3 7: For display unit (RD-20 or RD-50)

TTYCSLA-4 CN12, CN13

8: For BAM CN10 9: For BAM TTYCSLA-1 CN14 10: For transceiver unit (No. 2)

TTYCSLA-4 CN11

DIP SW Function 1 1: ON (Restore default settings.)

0: OFF (Default setting, for normal use) Note: When FE-800 starts up with “ON”, The “FA” mark appears at the top-left corner of the screen.

2 1: ON (Start the transceiver unit inde-pendently.)

0: OFF (Default setting, for normal use)

3 1: ON (Don’t back up settings.)

0: OFF (Default setting, for normal use)

4 Turn output to port 2 of IF-2503 [ON] or [OFF]. [ON] outputs a contact signal when the Depth-below-Keel alarm occurs.

5 Turn output to port 3 of IF-2503 [ON] or [OFF]. [ON] outputs a con-tact signal when any of the following errors occur.

• Bottom lost

• TX Volt Error

• TCVR High Temperature

6 Setting of the transceiver unit.

ON: No. 2, OFF: No. 1

7 to 8 No use.

DIP switchDIP switch

BatteryBattery

7. Connect ground wires with the pre-attached crimp-on lugs shown right. The cables that require grounding are shown in the column "Grounding" in the table at the top of this page.

8. Refasten the cable entrance as-sembly.

9. Turn on the power switch.

Power switch Set the power switch to On to acti-vate the Transceiver unit. The de-fault setting is Off.

Note: For maintenance, the power switch should be Off.

10. Close the covers.

Grounding

Attach the supplied copper strap between the fixing plate on the unit and the ship's ground.

Note: Ground the equipment to prevent mutual interference.

Ground point

Power switch (toggle)

ON

OFF

(Default setting)

Copper strap

Fixing plateFixing plate

2.5 Matching Box

The Matching box should be selected depending on the transducer type;

• 50B-6B transducer: MB-502

• 200B-8B transducer: MB-504

1. Remove four screws to open the top cover.

2. Unfasten the cable glands for both the transceiver unit and the transducer, then remove the gaskets and washers.

3. Slide the cable gland, the gasket and the flat washers onto the cable as shown below.

4. For the cable connected to transceiver unit, push the flat washer against the ar-mor. Then trim the armor so that it does not extend past the flat washers, then pass the cable through the cable entrance.

5. Tighten the cable glands with the hook spanner wrench.

Note: Use the wrench of the correct size. If you do not have the hook spanner wrench, contact our dealer.

Transceiver unit side

- Cable gland

- Three flat washers

- Gasket

The cable gland closest to the FURUNO logo is for the Transceiver unit.

Transducer side

- Cable gland

- Two flat washers

- Gasket

GasketGasket Cable glandCable gland

Cut and trim the armor.

Outer sheath Inner sheath

Flat washerFlat washer

Side: Transducer (2RNCT-SB 2C×1.4)Side: Transceiver unit (DPYCYSLA-2.5)

GasketGasket Cable glandCable gland

Flat washerFlat washer

SheathSheath

6. Connect the cables to terminal inside.

7. Close the top cover.

Grounding

Shorten the ground wire as much as possi-ble.

Note 1: Ground the equipment to prevent mutual interference.

Note 2: Use “closed-type” lugs to make the ground connection at the display unit and the matching box. Do not use an “open-type” lugs.

2.6 Bridge Alert Management (BAM) Connection

The power fail alarm can be output by connecting the Transceiver unit to the ship’s alert system or switchboard that can generate this type of alarm.

Connect the TTYCSLA-1 cable between CN14 in the transceiver unit and the alert system of the ship referring to the schematic diagram at the end of this manual.

2.7 Junction Box (Option)

Junction boxes are connected between the Transceiver unit and the Matching box as necessary.

CN14 terminals 1 & 3 CN14 terminals 2 & 3 Power supplied Close Open Power not supplied Open Close

From TransducerFrom Transceiver unit

Connect the cable from transceiver unit.

(2a: Ground wire)

1a1a 2a2a 3a3a 1T1T 2T2T 3T3T

Connect the cable from transducer.

(2T: Ground wire)

Ground point

TTYCSLA-1

NORMAL CLOSE

NORMAL OPEN

RELAY COMMON

CN14

Select either one.Alert System

3. ADJUSTMENTS

This section provides the procedures for initial set up of the equipment.

3.1 Service Menu

This [Service Menu] settings should be properly set before operating the equipment. Press the POWER key while pressing any key to open the [Service Menu]. An aural alert indicates that the [Service Menu] is now available and the [Service Menu] appears.

Service Menu

Menu Contents [FE-8010 Serial No.]

The serial no. for FE-8010 is shown.

[FE-8020 CON-

FIG]

When the second transceiver unit is connected, select [No.1 only] or [No.1&No.2].

After changing the setting, the window shown below appears. Select [Exit] to apply the changes then the transceiver unit restarts.

Note: Be sure to select [Exit] to correctly apply the changes.

[FE-8020 No.1 Setup], [FE-8020 No.2 Setup]

The setting for the transceiver unit.

[Serial No.]: The serial no. of selected transceiver unit is shown.

[FORE], [AFT]:

• [XDR]: Set the frequency.

Note: When [N/A] is selected on both [FORE] and [AFT] of each transceiver unit, the service menu is started at the restart.

• [KEEL]: Set the distance from the transducer to the keel.

Note: For configurations with a PP-505FE connected, this setting is calculated to the draft value as an offset in printed readings.

• [Bottom Detect]: Set the depth from which to start detection of the bottom.

• [Tx Count Reset]: Reset the TX count to zero.

[FAN0]:

• [FAN Limit]: Enter half of the fan ro-tation speed.

• [FAN Reset]: Reset the working hours of the fan.

[DISP Order] For dual frequency display, select the transducer to display in the left and right displays.

FANFAN

[External KP] Select [ON] to output the external KP to the other device.

[Random KP] Reduces interference. Turn [ON] in normal use.

[TX Mode] To take soundings properly the setting must be set to [ON].

Note: appears at the bottom-right corner of the screen when FE-800 is turned on with the [OFF] setting.

[B Volt] Set the voltage for B voltage. Select [Low] for normal use.

[Depth Accura-cy]

Select the method for measuring depth, [Normal] or [High]. [High] pro-vides depth with higher resolution.

[Alert] [Alert Mode Select]: Select the alert mode among [Legacy], [Alert I/ F1] and [Alert I/F 2]. If IF-2503 is connected to FE-800, select [Lega-cy].

• [Legacy]: Use IIalr and IIals sentences.

• [Alert I/F 1]: Use ALR and ACK sentences.

• [Alert I/F 2]: Use ALF and ACN sentences.

[Buzzer]: Set [ON] to sound the alarm against alarms other than the depth alarm.

[Time Adjust] Select the source for time, internal clock or external equipment.

[I/O] [EXT EQUIP]: Select the source of position data, among [DE], [GA], [GL], [GN], [GP], [II], [IN], [LA], [LC] or [ALL] (default setting: [GP]).

Note: [ALL], which selects the source in priority order, does not com-ply with IEC standards.

[Port1], [Port4]: Set the IEC standard to use for input and output sig-nals. See section 3.4.

[Port Monitor]: Show the port monitor.

[Ethernet]: Set up the Ethernet. See section 3.5.

[Network] [IP ADD]: Set the [IP address], [Subnet Mask] and [Default Gateway].

[SFI]: Set the System function ID (SFI) of FE-800 and the external equipment connected. This SFI must be unique on network IEC61162-450. Enter the four-digit number that follows “SD”.

SD0001:

Note: The ID must include “SD” to comply with IEC standards.

[EXT Setting Device]

[EXT Device Port]: Set the port for receiving settings from external equipment.

Select from PORT1, PORT4 and LAN. The default setting is LAN.

[EXT IP Address]: Input the IP address.

[EXT Port]: Set the port number for LAN connection.

[Dimmer Set-ting]

[Dimmer Mode]: Set whether the brightness setting is received from the other equipment.

FE-800: Ignore external equipment’s brightness settings.

ECDIS: Receive brightness setting from other equipment.

The default setting is FE-800.

[Dimmer Control Port]: Set the port to use for receiving brightness settings. Select from PORT1, PORT4 and LAN. The default setting is LAN. When LAN is selected, the IP address is automatically set to the same IP address as set at [Navigation]. (See section 3.5.)

[LCD Reset] Reset the working hours of LCD.

[TEST] [Self TEST]: Show the self test screen.

[LCD TEST]: Show the LCD test screen.

[Buzzer TEST]: Select this menu then the buzzer sounds if it is work-ing properly. To stop the buzzer, press the ENT key.

Menu Contents

TX OFF

3.2 How to Set the Time

On the [Menu] window, select [System] → [Ship’s Time] to set the time.

Select [External] to use time data which the external equipment outputs.

• [Time]: Select the source of time, [UTC] or [Local].

• [Time Difference]: If [Local] is selected in [Time], select [Auto] or [Manual] for setting method.

• [Local Zone]: If [Manual] is selected in [Time Difference], set the time difference.

Select [Internal] to use the internal clock.

Select [Date] or [Time] to adjust and then set the value with the or key.

Note: The internal clock continues to oper-ate when an external time source is used.

Battery

The battery installed on the circuit board 12P1000 inside the transceiver unit pre-serves data when the power is turned off. The life of the battery is about five years.

When the battery voltage is low, the warning message "Displayed time may be incor-rect. Please re-set the clock." appears after the self-test. When this happens, contact your dealer to request replacement of the battery. Press any key to proceed to the main display screen.

Note: The message "Displayed time may be incorrect. Please re-set the clock." ap-pears when the FE-800 is turned on for the first time or after changing the battery. In this case, the battery does not need replacement, however the clock must be set.

[DEMO] Activate the demonstration mode. appears at the bottom-right corner of the screen when the demonstration mode is turned on.

Note: The demonstration mode is not available with the No.2 trans-ceiver unit. Turning on the mode from the No.2 transceiver unit acti-vates the mode at the No.1 transceiver unit. After stopping the demonstration mode, the No.1 transceiver is activated.

[Service Reset] Reset the menu settings to the default settings. The confirmation message appears then select [Yes] to reset the settings.

[Exit] Exit the [Service Menu] then restart the system.

Item Type Code Number Qty Lithium Battery BR-1225-A/BK 000-178-989-10 1

Menu Contents

SIM

3.3 How to Set the Frequency

Set the transducer frequency with TB1 and TB3, according to the frequency setting on the [Service Menu]. To set frequency on the [Service Menu], select [FE-8020 No.1 (No.2) Setup] → [FORE] (or [AFT]) → [XDR].

The default tap setting on the TRX Board 12P1001 is for 50 kHz. For 200 kHz, set TB1 and TB3 as follows.

Note: Incorrect setting can affect performance and damage the transducer.

3.4 How to Set the Port

On the [Service Menu], select [I/O] → [Port1] (or [Port4]). [Port1] is for IN1 (CN9) and OUT1/2/3 (CN6/CN7CN13). [Port4] is for CN10.

Menu Contents [Input] Select standard for the input signal, [IEC] (default) or [NMEA].

[Output] Select the standard for the output signal, [NMEA V1.5], [IEC Ed.1] or

[IEC Ed.2/3/4] (default).

Note: [NMEA V1.5] does not comply with SOLAS standards.

TB1 TB3

Transceiver Unit

For 200 kHz:

For 50 kHz:

(Default setting)

TRX Board 12P1001

I /O

Port1 ► Port4 ► Port Monitor ► Ethernet ►

Por t1

Input : IEC Output : IEC Ed.2/3/4

3.5 How to Set the Ethernet

To set up the Ethernet for the LAN setting, select [I/O] → [Ethernet] on the [Service Menu], Menu Contents [Navigation] Set the destination terminal.

• [DEST IP Address]: Set IP address of the destination termi-nal. Available range: 239.192.0.1 to 239.192.0.64.

Note: The IP address must be within the available range to comply with the IEC standards.

• [DEST Port]: Set the port of the destination terminal.

• [Data Source]: Set the source data.

• [Error Counter]: Show the LAN error log.

[Management Profile] Set the Management Profile.

• [Management Profile]: Set [OFF] for normal use. Set [ON] to activate Management Profile.

• [DEST IP Address]: Set the IP address of the Management

Profile.

• [DEST Port]: Set the port of the Management Profile.

[Data Recorder] Set the Data recording software.

• [DEST IP Address]: Set the IP address of the Data recording software.

• [DEST Port]: Set the port of the Data recording software.

I /O

Port1 ► Port4 ► Port Monitor ► Ethernet ►

Ethernet

Navigation ► Management Profile ► Data Recorder ►

AP-1

APPENDIX 1 JIS CABLE GUIDE

Core Type Area Diameter

The following reference table lists gives the measurements of JIS cables commonly used with Furuno products:

TTYCSLA-4

MPYC-4

TPYCY

DPYCY

Cable Diameter

DPYC-1.5 1.5mm2 1.56mm 11.7mm DPYC-2.5 2.5mm2 2.01mm 12.8mm DPYC-4 4.0mm2 2.55mm 13.9mm DPYC-6 6.0mm2 3.12mm 15.2mm DPYC-10 10.0mm2 4.05mm 17.1mm DPYCY-1.5 1.5mm2 1.56mm 13.7mm DPYCY-2.5 2.5mm2 2.01mm 14.8mm DPYCY-4 4.0mm2 2.55mm 15.9mm MPYC-2 1.0mm2 1.29mm 10.0mm MPYC-4 1.0mm2 1.29mm 11.2mm MPYC-7 1.0mm2 1.29mm 13.2mm MPYC-12 1.0mm2 1.29mm 16.8mm TPYC-1.5 1.5mm2 1.56mm 12.5mm TPYC-2.5 2.5mm2 2.01mm 13.5mm TPYC-4 4.0mm2 2.55mm 14.7mm TPYCY-1.5 1.5mm2 1.56mm 14.5mm TPYCY-2.5 2.5mm2 2.01mm 15.5mm TPYCY-4 4.0mm2 2.55mm 16.9mm

TTYCS-1 0.75mm2 1.11mm 10.1mm TTYCS-1T 0.75mm2 1.11mm 10.6mm TTYCS-1Q 0.75mm2 1.11mm 11.3mm TTYCS-4 0.75mm2 1.11mm 16.3mm TTYCSLA-1 0.75mm2 1.11mm 9.4mm TTYCSLA-1T 0.75mm2 1.11mm 10.1mm TTYCSLA-1Q 0.75mm2 1.11mm 10.8mm TTYCSLA-4 0.75mm2 1.11mm 15.7mm TTYCY-1 0.75mm2 1.11mm 11.0mm TTYCY-1T 0.75mm2 1.11mm 11.7mm TTYCY-1Q 0.75mm2 1.11mm 12.6mm TTYCY-4 0.75mm2 1.11mm 17.7mm TTYCY-4S 0.75mm2 1.11mm 21.1mm TTYCY-4SLA 0.75mm2 1.11mm 19.5mm TTYCYS-1 0.75mm2 1.11mm 12.1mm TTYCYS-4 0.75mm2 1.11mm 18.5mm TTYCYSLA-1 0.75mm2 1.11mm 11.2mm TTYCYSLA-4 0.75mm2 1.11mm 17.9mm

EX: TTYCYSLA - 4 MPYC - 4

Designation type Core Area (mm2) Designation type # of cores

1 2 3 4 5 6 1 2 3 4

Cables listed in the manual are usually shown as Japanese Industrial Standard (JIS). Use the following guide to locate an equivalent cable locally.

JIS cable names may have up to 6 alphabetical characters, followed by a dash and a numerical value (example:

DPYC-2.5).

For core types D and T, the numerical designation indicates the cross-sectional Area (mm2) of the core wire(s) in the cable.

For core types M and TT, the numerical designation indicates the number of core wires in the cable.

1. Core Type D: Double core power line T: Triple core power line M: Multi core TT: Twisted pair communications

(1Q=quad cable)

2. Insulation Type P: Ethylene Propylene Rubber

3. Sheath Type Y: PVC (Vinyl)

4. Armor Type C: Steel

5. Sheath Type Y: Anticorrosive vinyl sheath

6. Shielding Type S: All cores in one sheath -S: Indivisually sheathed cores SLA: All cores in one shield, plastic tape w/aluminum tape -SLA: Individually shielded cores, plastic tape w/aluminum tape

Core Type Area Diameter

Cable Diameter

APPENDIX 2 DIGITAL INTERFACE

I/O Sentences

Note 1: ACK and ALR sentences are available when [Mode] in the [Alert] menu is set to [Alert I/F 1].

Note 2: ACN, ALC, ALF, ARC and HBT sentences are available when [Mode] in the [Alert] menu is set to [Alert I/F 2].

Note 3: ACK, ALR, ACN, ALC, ALF, ARC and HBT sentences are not available when [Mode] in the [Alert] menu is set to [Legacy].

• Input sentences

ACK, ACN, DDC*3, GGA, GLL, HBT, RMA, RMC, VTG, ZDA

• Output sentences

ALC, ALF, ALR, ARC, DBK, DBS, DBT*2, DDC*3, DPT, HBT, Pfec SDmsi*1

*1: Mandatory, for multiple (more than one) transducer installation.

*2: Only use if transducer and keel have the same level.

*3: Output when [Dimmer Control] is ON.

• Transmission interval 1 s for any sentence other than ALC, ARC and HBT (At 30 seconds interval for ALC, at 50 sec-onds interval for HBT)

Note: ALF, ARC, ALR and DDC*3 are transmitted when an event occurs. ALR can be transmit-ted at 30 seconds intervals and DDC*3 can be transmitted at 60 seconds intervals.

• Data transmission Data is transmitted in serial asynchronous form in accordance with the standard referenced in

2.1 of IEC 61162-1. The first bit is a start bit and is followed by data bits, least-significant-bit as illustrated below.

The following parameters are used:

• Baud rate: 4800

• Data bits: 8 (D7 = 0), parity none

• Stop bits: 1

D0 D1 D2 D3 D4 D5 D6 D7

Start bit Stop bitData bits

AP-2

Data sentences: Input

Data format is IEC 61162-1 Edition 5 unless noted otherwise.

ACN: Alert command

ACK: Acknowledge alarm

DDC: Display Dimming Control

GGA: Global positioning system (GPS) fix data

$**ACN,hhmmss.ss,aaa,x.x,x.x,c,a*hh<CR><LF> 1 2 3 4 5 6

1. No use

2. Manufacturer mnemonic code (3 digit alphanumeric code), null

3. Alert identifier (0 to 999999)

4. No use

5. Alert command (A=ACK from ext. equipment, Q=Request from ext.

equipment, O=Responsibility transfer, S=Silence from ext. equipment)

6. Sentence status flag (C should not be null field. Sentence without C is not a command.)

$**ACK,xxx *hh<CR><LF>

1. Unique alarm number (identifier) at alarm source

$**DDC,a,xx,a,a,*hh<CR><LF> 1 2 3 4

1. Display dimming preset

2. Brightness percentage 00 to 99

3. Color palette

4. Sentence Status Flag

$ ** GGA, hhmmss.ss, llll.ll, a, yyyyy.yy, a, x, xx, x.x, x.x, M, x.x, M, x.x, xxxx *hh <CR><LF> 1 2 3 4 5 6 7 8 9 10 11 12 13 14

1. UTC (no use)

2. Latitude

3. N/S

4. Longitude

5. E/W

6. Quality index

7. Satellites used (no use)

8. DOP (no use)

9. Antenna height above the sea level (no use)

10. Unit (M) (no use)

11. Geoid height (no use)

12. Unit (M) (no use)

13. Age of differential GPS date (no use)

14. Differential reference station ID (no use)

AP-3

GLL: Geographic position. Latitude/longitude

HBT: Heartbeat supervision sentence

RMA: Recommended minimum specific LORAN-C data

RMC: Recommended minimum specific GNSS data

$ ** GLL, llll.ll, a, yyyyy.yyy, a, hhmmss.ss, A, x *hh <CR><LF> 1 2 3 4 5 6 7

1. Latitude

2. N/S

3. Longitude

4. E/W

5. No use

6. Status (A: Data valid)

7. Mode indicator (A: Autonomous, D: Differential mode)

$**HBT,x.x,A,x*hh<CR><LF> 1 2 3

1. Configured repeat interval (1 to 999)

2. Equipment status (A=Normal V=System fail)

3. Sequential sequence identifier (0 to 9)

$**RMA,A,llll.ll,a,yyyyy.yy,a,x.x,x.x,x.x,x.x,x.x,a,a*hh <CR><LF> 1 2 3 4 5 6 7 8 9 10 1112

1. Status: A=Data valid

2. Latitude, degrees (0.0000 to 9000.0000)

3. N/S

4. Longitude, degrees (0.0000 to 18000.0000)

5. E/W

6. No use

7. No use

8. Speed over ground, knots

9. Course over ground, degrees true

10. Magnetic variation, degrees

11. E/W

12. Mode indicator (A= Autonomous D= Differential mode)

$ ** RMC, hhmmss.ss A, llll.ll, a, yyyyy.yy, a, x.x, x.x, xxxxxx, x.x, a, a, a *hh <CR><LF> 1 2 3 4 5 6 7 8 9 10 11 12 13

1. UTC of position fix

2. Status: A=data valid

3. Latitude

4. N/S

5. Longitude

6. E/W

7. Speed over ground, knots

8. Course over ground, degrees true

9. Date: dd/mm/yy

10. Magnetic variation, degrees E/W

11. E/W

12. Mode indicator (A=Autonomous mode, D=Differential mode)

13. Navigational status indicatior (S=Safe, C=Caution)

AP-4

Data sentences: Output

VTG: Course over ground and ground speed

ZDA: Time and date

ALC: Cyclic alert list

$ ** VTG, x.x, T, x.x, M, x.x, N, x.x, K, a *hh <CR><LF> 1 2 3 4 5 6 7 8 9

1. Course over ground, degrees true

2. T

3. Course over ground, degrees magnetic

4. M

5. Speed over ground, knots

6. N

7. Speed over ground, km/h

8. K

9. Mode indicator (A=Autonomous, D=Differential)

$ ** ZDA, hhmmss.ss, xx, xx, xxxx, xx, xx *hh <CR><LF> 1 2 3 4 5 6

1. UTC

2. Day

3. Month

4. Year

5. Local zone hours

6. Local zone minutes

$**ALC,xx,xx,xx,x.x, aaa,x.x,x.x,x.x,’’’’’’ *hh<CR><LF> 1 2 3 4 5 6 7 8 9

1. Total number of sentences this message (01 to 99)

2. Sentence number (01 to 99)

3. Sequential message identifier (00 to 99)

4. Number of alert entries (0 to n)

5. Manufacturer mnemonic code (FEC, null)

6. Alert identifier (000 to 999999)

7. Alert instance (null)

8. Revision counter (1 to 99)

9. Additional alert entries (same as 5 and 8. When #4=0, #5 to #9 are deleted.)

AP-5

ALF: Alert sentence

ALR: Set alarm state

ARC: Alert command refused

DBK: Depth below keel

$**ALF,x,x,x,hhmmss.ss,a,a,a,aaa,x.x,x.x,x.x,x,c--c *hh<CR><LF> 1 2 3 4 5 6 7 8 9 10 11 12 13

1. Total number of ALF sentences this message (1, 2)

2. Sentence number (1, 2)

3. Sequential message identifier (0 to 9)

4. Time of last change (hh=00 to 23, mm=00 to 59, ss.ss=00.00 to 59.99), null

5. Alert category (A=Alert category A, B=Alert category B, null)

6. Alert priority (A=Alarm, W=Warning, C=Caution), null when #2 is 2.

7. Alert state (V=Not ACKed, S=Silence, A=ACKed, O/U=Resolved, Not ACKed, N=Normal state), null when #2 is 2.

8. Manufacturer mnemonic code (FEC, null)

9. Alert identifier (000 to 999999)

10. Alert instance (null)

11. Revision counter (1 to 99)

12. Escalation counter (0 to 9)

13. Alert text (max. 16 characters for the 1st sentence, maximum length of the field for the

2nd sentence later)

$**ALR,hhmmss.ss,xxx,A,a,c—c *hh<CR><LF> 1 2 3 4 5

1. Time of alarm condition change, UTC

2. Unique alarm number (identifier) at alarm source

3. Alarm condition (A=threshold exceeded, V=not exceeded)

4. Alarm acknowledge state (A=acknowledged, V=unacknowledged)

5. Alarm’s description text

$**ARC,hhmmss.ss,aaa,x.x,x.x,c*hh<CR><LF> 1 2 3 4 5

1. Release time of the alert command refused (hh: 00 to 23, mm: 00 to 59, ss.ss: 00.00 to 59.99)

2. Used for proprietary alerts, defined by the manufacturer (FEC, null)

3. The alert identifier (000 to 999999)

4. The alert instance (Null)

5. Refused alert command (A: Acknowledge)

$**DBK,x.x,f,x.x,M,x.x,F *hh<CR><LF> 1 2 3 4 5 6

1. Water depth

2. feet

3. Water depth

4. Meters

5. Water depth

6. Fathom

AP-6

DBS: Depth below surface

DBT: Depth below transducer

DDC: Display Dimming Control

DPT: Depth

HBT: Heartbeat supervision sentence

$**DBS,x.x,f,x.x,M,x.x,F *hh<CR><LF> 1 2 3 4 5 6

1. Water depth

2. feet

3. Water depth

4. Meters

5. Water depth

6. Fathom

1, 2 Water depth, feet 3, 4 Water depth, m 5, 6 Water depth, fathom

$ ** DBT, x.x, f, x.x, M, x.x, F *hh <CR><LF> 1 2 3 4 5 6

$**DDC,a,xx,a,a,*hh<CR><LF> 1 2 3 4

1. Display dimming preset

2. Brightness percentage 00 to 99

3. Color palette

4. Sentence Status Flag

$ ** DPT, x.x, x.x, x.x *hh <CR><LF> 1 2 3

1. Water depth relative to transducer, in meters

2. Offset from transducer, in meters

3. Maximum range scale in use

$**HBT,x.x,A,x*hh<CR><LF> 1 2 3

1. Configured repeat interval (50s)

2. Equipment status (A=Normal)

3. Sequential sequence identifier (0 to 9)

AP-7

SDmsi: Multiple Sounding Information

$PFEC,SDmsi,x.x,x.x,a,a,c--c,x.x,x.x,x.x,x.x,x.x,x,x *hh<CR><LF> 1 2 3 4 5 6 7 8 9 10 11 12 13

1. Number of sounding information

2. Total number of sounding information

3. Depth Unit (M: meter, f: feet)

4. Reference for reading depth

5. Transducer information (F: Fore, A: Aft)

6. Transmission frequency

7. Water depth

8. Offset from transducer to surface

9. Offset from transducer to keel

10. Number of sounding information

11. Depth Alarm

12. Number of transceiver unit

13. Total number of transceiver unit

AP-8

A -1

-2

-3

-4

-5

-6

D-1

D-2

D-3

D-4

D-5

D-6

D-7

4/Oct/2018 H.MAKI

D-8

/M ay /2

H .M

A K

I

牧 宏 昌

電 子 署 名 者

牧

宏 昌

D

N cn =牧

宏 昌

, o =古 野 電 気

, o u= 情 技 課 em ai l= hi ro m as a.

m ak i@ fu ru no .c o.

jp

, c =J

P 日 付

.0

5.

5:

:1

+0

9'

D-9 ay /2

H .M

A K

I

牧 宏 昌

電 子 署 名 者

牧 cn =牧

宏 昌

, o =古 野 電 気

, o u= 情 技 課 em ai l= hi ro m as a.

m ak i@ fu ru no .c o.

jp

, c =J

P 日 付

.0

5.

5:

:0

+0

9'

D-10

4/ O ct /2

H .M

A K

I

D-11 ay /2

H .M

A K

I

牧 宏 昌

電 子 署 名 者

牧 cn =牧

宏 昌

, o =古 野 電 気

, o u= 情 技 課 em ai l= hi ro m as a.

m ak i@ fu ru no .c o.

jp

, c =J

P 日 付

.0

5.

5:

:1

+0

9'

D-12

D-13

D-14

/D ec /2

H .M

A K

I

S-1

The paper used in this manual is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN

A : MAY 2014Printed in JapanAll rights reserved.

G : OCT . 29, 2019

Pub. No. IME-23840-G

(ETMI ) FE-800

0 0 0 1 7 9 8 2 8 1 6