HB-461-001 EM2040 MkII 0.4x0.7 Installation.pdf
PDF 1 MB Posted
- Attached to
- FY21 Henry Bigelow Drydock Repairs
- Solicitation number
- 1305M220QNMAN0190
About this file
This document package includes an engineering drawing set and related federal contract opportunity. The engineering drawing set provides installation details for a 0.4x0.7 EM2040 MkII multibeam echo sounder aboard the NOAA ship Henry Bigelow. It includes general arrangement drawings, scantling details, equipment installation details, piping details, conduit and vent routing diagrams, and cabling details.
The related federal contract opportunity is solicitation number 1305M220QNMAN0190 for FY21 Henry Bigelow drydock repairs from the Department of Commerce National Oceanic and Atmospheric Administration. The scope of work involves structural modifications, equipment installations and other work incidental to installing the 0.4x0.7 EM2040 MkII multibeam echo sounder aboard the NOAA ship Henry Bigelow, as depicted in the engineering drawing set.
View the file
Other files
Show 40 more
Latest 50 of 106 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
600mm
AP
100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15
400mm
FP
510 0
BASELINE
FLWL 6.1m
45 45 ofSheet
Rev
Scale
C
A
D
Maritime Systems Division 2750 Prosperity Avenue Suite 600 Fairfax VA 22031
(703) 270 1540
Size
Drawing Title
Drawn by Date Prepared for
Date
Date
Checked by
Approved by
NOAA Office of Marine & Aviation Operations 8403 Colesville Road
Silver Spring MD 20910
B
C
A
D
Drawing Number
THIRD ANGLE PROJECTION
UNLESS OTHERWISE SPECIFIED
DIM ARE IN INCHES
TOL ON ANGLE ± 0.01°
INTERPRET DIM AND TOL PER
ASME Y14.5M-2009
ABS Approval Date
DateUSCG Approval
HULL NUMBER
HB-461-001D
R 225
NOAA SHIP HENRY BIGELOW
SWBS
EM2040 MKII 0.4X0.7 INSTALLATION
D W
G :H
B-
1-
R
EV
GENERAL NOTES
1AS NOTED
NWT 7/9/2020
BILL OF MATERIALS
NO. QTY UNIT MFG# / PART # DESCRIPTION MATERIAL MATL. SPEC. SCE UNIT WT. REMARKS
1 1 EA - 0.4x0.7 EM2040 CASING ASSEMBLY STEEL ABS GRADE A CFM N/A
2 1 EA TX MODULE VARIOUS - CFM N/A
3 1 EA RX MODULE VARIOUS - CFM N/A
4 1 EA GV-200B-8B GATE VALVE VARIOUS - CFM 375 LB INCLUDES HARDWARE, GASKETS, ETC
5 14 FT2 - 1
2" PLATE STEEL ABS GRADE A CFM 20.4 LB/FT2
6 6 FT2 - 3
8" PLATE STEEL ABS GRADE A CFM 15.3 LB/FT2
7 23 FT - 3-1
2" SCH80 PIPE STEEL ASTM A53 CFM 12.5 LB/FT SEAMLESS, BUTT WELDED JOINTS
8 66 FT - 1-1
2" SCH 80 PIPE STEEL ASTM A53 CFM 3.65 LB/FT SEAMLESS, BUTT WELDED JOINTS
9 1/4 FT - 4-1
2" TUBE STEEL ASTM A53 CFM - 1
4" WALL THICKNESS
10 1 EA - 1-1/2" 90° ELBOW STEEL ASTM A234 CFM - SCHED 80, BUTT WELDED
11 5 EA - 1-1/2" LONG RADIUS 90° ELBOW STEEL ASTM A234 CFM - SCHED 80, BUTT WELDED
12 2 EA - 1-1/2" 45° ELBOW STEEL ASTM A234 CFM - SCHED 80, BUTT WELDED
13 1 EA - 1-1/2" 180° RETURN CONNECTOR STEEL ASTM A234 CFM - SCHED 80, BUTT WELDED
14 1 EA - 4" MCT FRAME VARIOUS - CFM 1.1 LB ROXTEC R100 OR EQUIVALENT
15 6 EA RM15 MCT CABLE GLAND MODULE - - CFM - ROXTEC RM15 OR EQUIVALENT
16 3 EA RM15/0 MCT BLANK MODULE - - CFM - ROXTEC RM15/0 OR EQUIVALENT
17 20 EA - 3/8-16 UNC BOLT STAINLESS STEEL TYPE 316 CFM -
18 20 EA - 3/8-16 UNC NUT STAINLESS STEEL TYPE 316 CFM -
19 20 EA - 3
8" WASHER STAINLESS STEEL TYPE 316 CFM -
20 2 FT2 - 5
16" GASKET NEOPRENE - CFM -
No. REFERENCE DWG No.
1 GENERAL ARRANGEMENTS HB-085-FA02 REV. 7
2 HULL MIDBODY SCANTLINGS FR19-FR49 HB-110-FH03 REV. 0
3 VENTS & SOUNDS SYS DIAGRAM HB-506-FP02 REV. 4
4 CASING, 0.7x0.7 EM2040/SVP70, NANCY FOSTER 124930
5 TRANSDUCER INSTALLATION DETAILS HB-169-FH50 REV. 6
6 INSTALLATION MANUAL - NAVIGATIONAL ECHO SOUNDER
MODEL FE-800
7 PAINT SCHEDULE HB-631-FF04 REV. 0
8 STANDARD PIPING DETAILS HB-505-FP25
9 EM2040 INSTALLATION CABLE RUN DETAILS HB-461-002
1 - GENERAL NOTES
2 - REMOVALS
3 - INSTALLATION & WELD DETAILS, EM2040 & FE800
4 - PIPING DETAILS
5 - CONDUIT & VENT PIPE ROUTING
6 - VENT PIPE ROUTING
7 - CABLING DETAILS
CABLE INSTALLATION NOTES
C-1 CABLES ARE GFE, FOR CABLE LIST SEE SHEET 7
C-2 PROTECT WET AND DRY SIDE CONNECTORS SO TO
NOT DAMAGE DURING INSTALLATION
C-3 CABLES WILL NEED TO BE PULLED IN SEQUENCE
FOR PROPER FIT IN CONDUIT
C-4 FOR ALL CABLE RUNS TO LOCATIONS NOT SHOWN
ON THIS DRAWING, USE EXISTING CABLEWAYS
AND PATHS UNLESS DIRECTED OTHERWISE BY
KONGSBERG
C-5 KONGSBERG ENGINEER SHALL EXAMINE PATH
AND RECOMMEND CHANGES BASED ON
PROXIMITY TO CABLES THAT MIGHT CAUSE
ELECTRICAL INTERFERENCE
C-6 PULL CABLES BY HAND ONLY
C-7 PULL CABLES FROM WET SIDE TO DRY SIDE
C-8 PULL CABLES UNDER THE DIRECTION OF THE
ON-SITE KONGSBERG ENGINEER OR COR
C-9 EXISTING ABOVE-DECK EQUIPMENT POWER AND
INTERFACE WILL BE UTILIZED. KONGSBERG
ENGINEER WILL MAKE OR MODIFY THESE
CONNECTIONS IF NECESSARY TO CONNECT /
INTERFACE TO THE EQUIPMENT
C-10 INSTALLING ACTIVITY SHALL PROVIDE CABLE TAGS
FOR ALL CABLES. SEE SHEET 7 FOR CABLE TAG
DETAILS
C-11 CABLE TAGS SHALL BE STAMPED WITH 12" INCH
LETTERING AND MADE FROM 304 OR 316
STAINLESS STEEL
C-12 CABLE TAGS SHALL BE INSTALLED WITHIN 1' OF
ALL TERMINATIONS AND WITHIN 1' OF EACH SIDE
OF ALL PENETRATIONS
C-13 SPARE CABLING NOTED IN DET 49-A SHALL BE RUN
AS CLOSELY AS POSSIBLE TO CORRESPONDING
PRIMARY CABLING AND COILED NEAR
CORRESPONDING TERMINATION WITH UNUSED
CONNECTION PROTECTED FROM MOISTURE, DIRT,
DUST, GRIME, OR OTHER POSSIBLE DAMAGE
C-14 DUMMY PLUGS SHALL BE INSTALLED ON SPARE TX,
RX, AND SVP CABLING WITHIN EM2040 MkII CASING, AND BE INSTALLED AS TO BE ACCESSIBLE BY
DIVERS.
GENERAL NOTES
1 THIS DRAWING PROVIDES STRUCTURAL MODIFICATION DETAILS INCIDENTAL TO THE
INSTALLATION OF 0.4x0.7 EM2040 MkII MULTIBEAM ECHOSOUNDER ABOARD NOAA SHIP HENRY
BIGELOW
2 INSTALLATION OF GATE VALVE INCIDENTAL TO RELOCATION OF FE800 TRANSDUCER SHALL BE IN
ACCORDANCE WITH REF. 4
3 ALL NEW STEEL SHALL BE ABS GRADE A UNLESS NOTED OTHERWISE.
4 ALL WELDING, WORKMANSHIP, AND MATERIALS, SHALL BE IN ACCORDANCE WITH USCG AND ABS
REGULATIONS.
5 ALL STRUCTURAL DETAILS AND GENERAL NOTES NOT SHOWN ON THIS DRAWING SHALL BE IN
ACCORDANCE WITH REF 2.
SHARP OR ROUGH EDGES OF EXPOSED WORK SHALL BE GROUND SMOOTH TO PREVENT INJURY
TO PERSONNEL OR DAMAGE TO EQUIPMENT.
6 NEW METAL SHALL BE BLASTED TO SSPC-SP-10 NEAR WHITE AND PRIMED WITH INORGANIC ZINC
WELD THROUGH SHIP PRIMER. WELDS AND DAMAGED AREAS SHALL BE SPOT BLASTED AND
REPRIMED.
7 COATINGS SHALL BE APPLIED TO MATCH SURROUNDING AREAS IN ACCORDANCE WITH REF. 7
8 BULKHEAD AND DECK PENETRATIONS SHALL BE MADE THROUGH THE USE OF APPROVED
STUFFING TUBES OR TRANSIT DEVICES WHICH WILL MAINTAIN THE WATERTIGHT, FIRE TIGHT, OR
SMOKE TIGHT (AS APPLICABLE) INTEGRITY OF THE BULKHEADS OR DECK
9 PHILLY BOND FAIRING COMPOUND SHALL BE APPLIED AS SHOWN IN REF. 5 DETAIL 31-B AT 5:1
SLOPE TO CREATE A STREAMLINED TAPER & PREVENT THE WATER FLOW FROM TRIPPING.
PHILLY BOND FAIRING COMPOUND SHALL BE GROUND TO OBTAIN A 250 MICRO-INCH SURFACE
FINISH.
10 MATERIAL LENGTHS ARE APPROXIMATE. EXACT LENGTHS FOR INSTALLATION SHALL BE
MEASURED FROM THE SHIP AND EQUIPMENT, AS NECESSARY.
11 PIPE ROUTING IS APPROXIMATE. EXACT ROUTING MUST BE VERIFIED AND TARGETED BY
CONTRACTOR BEFORE INSTALLATION.
MESSROOM 1-19-0
PASSAGE 2-29-0 & SR 2-34-3
TRANSDUCER ROOM 4-34-0
KEY 3-B
SCALE: 1
512" = 1'
AREAS OF WORK
APPROVEDDATEDESCRIPTIONREV
REVISION HISTORY
ZONE
DRAWING INDEX
SHT REV TITLE
AutoCAD SHX Text
HAUL
24 25 26 27 28
FWD
PLAN 10-A
SHELL PLATING REMOVALS
TRANSDUCER ROOM 4-23-0
37 12"x4"x3
4" FLG PL (E)
ofSheet
Rev
Scale
B
C
A
D
Size
Sheet Title
Drawing Number
D HB-461-001
B
C
A
D
REMOVALS
21/32" = 1'
AB
R1
R2
Ø12
37 12"x4"x3
4" FLG PL (E)
SECTION 13-B
FRAME 27 REMOVALS
SECTION 13-A
FRAME 26 REMOVALS
℄1
2" GUSSET PL (REMOVE)
2" GUSSET PL (REMOVE)
PASSIVE SONAR (E)
SPEED LOG (E)
FE800
XDCR (E)
SELF-NOISE
HYDROPHONE (E)
x3 x5 16 F
LG
P
L (T
YP
37 12 x 4 x 34" FLG PL
24 25 26 27 28 ofSheet
Rev
Scale
B
C
A
D
Size
Sheet Title
Drawing Number
D HB-461-001
B
C
A
D
INSTALL. & WELD DETAILS, EM2040 & FE800
31/32" = 1'
FWD℄
PLAN 18-A
INSTALLATIONS
TRANSDUCER ROOM 4-23-0
SELF-NOISE
HYDROPHONE (E)
PASSIVE
SONAR (E)
SPEED
LOG (E)
R2
FE800 XDCR (E) &
GATE VALVE (N)
B
B25
SECTION 17-C
FE800 XDCR & GATE VALVE INSTALLATION
SCALE: 1
16" = 1'
FE800 XDCR (E)
FAIRING COMPOUND, SEE G.N. 9
FAIRING COMPOUND, SEE G.N. 9
SEE REF 6 FOR VALVE
INSTALLATION DETAILS
CA
SECTION 21-B
CASING COLLAR INSTALLATION - FR 27
SECTION 21-A
CASING COLLAR INSTALLATION - FR 26
DETAIL 19-C
FRAME 26 COLLAR
SCALE: 1
16" = 1'
DETAIL 22-C
FRAME 27 COLLAR
SCALE: 1
16" = 1'
1 4
Ø2Ø2
4° 4°
31 31
8 95
81 2 91 8
3/8
FP
3/8
TYP
22-C
3/8
3/8
3/8
TYP
19-C
3/8
3/8
1 2
12 12 12 ofSheet
Rev
Scale
B
C
A
D
Size
Sheet Title
Drawing Number
D HB-461-001
B
C
A
D
PIPING DETAILS
41/16" = 1'
SECTION 25-B
EM2040 CASING COLLAR INSTALLATION
10"x3"x 5
16" FLG PL (E)
DETAIL 27-D
PIPE COLLAR INSTALLATION
SCALE: 18" = 1'
DETAIL 26-D
PIPE COLLAR DETAIL
SCALE: 18" = 1'
D
81 2 31 241 2
SECTION 25-D
DETAIL 29-C
VENT PIPE NON-TIGHT
PENETRATION
C
SECTION 28-C
DETAIL 29-B
VENT PIPE WATERIGHT / FLAMETIGHT
PENETRATION
DETAIL 32-B
VENT BOX
B
SECTION 31-B
71 2
DETAIL 32-D
ACCESS PLATE
Ø13
R21
R1
TOP, BOTTOM,
SIDES
26-C
1/2
CP
1/2
CP6
21-B
21-A
1/8
CP
3/16
CP
5/16
TYP
32-D
TYP
5/16
CP
3/8
CP
3/8
CP
27-D
NOTE: INSTALL BOLT
HOLES TO ALIGN
WITH COVER PLATE
25 20
25 20
25 20 ofSheet
Rev
Scale
B
C
A
D
Size
Sheet Title
Drawing Number
D HB-461-001
B
C
A
D
CONDUIT & VENT ROUTING
51/64" = 1'
ELEVATION 33-A
CONDUIT & VENT ROUTING
TANK TOP
2ND DECK
MAIN DECK
01 DECK
1 2
1 4
33 A
1 2
3 4
PLAN 36-A
CONDUIT ROUTING
TANK TOP
PLAN 38-A
CONDUIT ROUTING
INNERBOTTOM
R24
R24
4 153
1 2
32-B
53-B
29-B
29-C
29-B
THRU
PASS
THRU
PASS
FT
DN
W
T ofSheet
Rev
Scale
B
C
A
D
Size
Sheet Title
Drawing Number
D HB-461-001
B
C
A
D
VENT PIPE ROUTING
61/64" = 1'
PLAN 44-C
VENT ROUTING
MAIN DECK
PLAN 41-C
VENT ROUTING
01 DECK
ELEVATION 41-B
CONDUIT & VENT ROUTING
VIEW LOOKING AFT
ELEVATION 41-C
CONDUIT & VENT ROUTING
VIEW LOOKING AFT
PLAN 46-B
VENT ROUTING
2ND DECK
C
B
1 2
47 8
MN DK
01 DK
47 8
1 4
1 2
5 8
1 2
PASSAGE
2-29-0
SR (2)
2-34-2
MESSROOM
1-19-0
SR (2)
01-24-4
SR (2)
01-19-2
MN DK
01 DK
7/
C1 AC IN C2
MONITOR
#1
KEYBOARD
C4
MOUSE
C5
C17
NETB
C2
C5
C4
C6
USB
DVI
USB
NETA
EM2040
HP HWS
COM
AC IN C3
C19
C17
(CFE)
SVP-70
SVP-70
JUNCTION
BOX C18 C18 MISSION UPS
EM 2040 SINGLE SLIM PU
CONSOLE
(G G
A/ZD
A)
(ATTITU
D
E)
C7
C8
PORT1
PORT2
PORT3
PORT4
ETH0
ETH1
ETH2
ETH3
ETH4
SYNC
CBMF
EM 2040
BOARD
100-250
VAC
POWER
GROUND
CONCURRENT
CPU
BOARD
ETH1
ETH2
USB0
USB2
USB1
ETHERNET
SWITCH
BOARD
ETH5
ETH6
ETH7
ETH8
CPU3
1PPS
ETH1
ETH2
48VDC
OUT
48VDC
OUT
C6
C11
C10
C12
C11
(ATTITU
D
E VELO
C
ITY)
(1PPS)
EM2040
TX
TRANSDUCER
C9
C16
EM2040
RX
TRANSDUCER
C16
C10
PASSAGEWAY 2-24-0
ME70 RACK - BOTTOM
COMPUTER LAB 1-38-2
POSMV
C12
C13
SPARE
C7
C8
SPARE
SPAR
E
SP-C12
SP-C12
SP-C13
SP-C13
SPAR
E
C13
C3 MISSION UPS
C19
C14 MISSION UPS
C10
HULL-MOUNTED EM2040 CASING
COM
OLEX
COMPUTER
COM
COM
BRIDGE 03-34-0
COM C20
C1MISSION UPS
SP-C10
SP-C10
SP-C17
C17
SP-C9
C9
C17
SP-C17
C9
SP-C9
C20
C21
C22
C14
C15 C15
C18
C19 ofSheet
Rev
Scale
B
C
A
D
Size
Sheet Title
Drawing Number
D HB-461-001
B
C
A
D
CABLING DETAILS
7NOT TO SCALE
DETAIL 49-A
CABLE DIAGRAM
DETAIL 53-B
MCT ARRANGEMENT
CABLE PLAN
CABLE
NO.
FROM TO
SIGNAL CABLE TYPE CABLE DESCRIPTION
IEEE MAX
CABLE
LENGH
SOURCE
DEVICE CONNECTOR TYPE /
PORT DESCRIPTION LOCATION DEVICE
CONNECTOR
TYPE / PORT
DESCRIPTION
LOCATION
C1 MONITOR #1 IEC320 COMP LAB 1-38-2 SHIP'S POWER - CIRCUIT TBD NEMA 5-15 COMP LAB 1-38-2 115 VAC SWE AC POWER CORD N/A KONGSBERG
C2 MONITOR #1 DVI COMP LAB 1-38-2 EM2040 HP HWS DVI COMP LAB 1-38-2 VIDEO SWE VIDEO CABLE N/A KONGSBERG
C3 EM2040 HP HWS IEC320 COMP LAB 1-38-2 SHIP'S POWER - CIRCUIT TBD NEMA 5-15 COMP LAB 1-38-2 115 VAC SWE AC POWER CORD N/A KONGSBERG
C4 EM2040 HP HWS USB COMP LAB 1-38-2 KEYBOARD MOLDED COMP LAB 1-38-2 KEYBOARD SWE KEYBOARD N/A KONGSBERG
C5 EM2040 HP HWS USB COMP LAB 1-38-2 MOUSE MOLDED COMP LAB 1-38-2 MOUSE SWE MOUSE N/A KONGSBERG
C6 EM2040 HP HWS RJ45 / NET A COMP LAB 1-38-2 EM2040 SINGLE SLIM PU / CCB RJ45/ETH1 COMP LAB 1-38-2 ETHERNET SWE 4 TWISTED PAIRS 100 KONGSBERG
C7 EM2040 SINGLE SLIM PU / CCB RJ45 / PORT1 IMU ROOM 2-24-0 POS/MV DB9-F COMP LAB 1-38-2 GGX/ZDA CAT6 LSZH 4 TWISTED PAIRS 100 CFE
C8 EM2040 SINGLE SLIM PU / CCB RJ45 / PORT2 IMU ROOM 2-24-0 POS/MV DB9-F COMP LAB 1-38-2 ATTITUDE CAT6 LSZH 4 TWISTED PAIRS 100 CFE
C9
EM2040 SINGLE SLIM PU / ESB RJ45 / ETH2 IMU ROOM 2-24-0 EM2040 TX TRANSDUCER DIL13M EM2040 CASING 48VDC / ETHERNET SWE POWER / ETHERNET CABLE 15 KONGSBERG
EM2040 SINGLE SLIM PU / ESB RJ45 / ETH4 IMU ROOM 2-24-0
EM2040 SINGLE SLIM PU / POWER THREE LEMO / 48VDC IMU ROOM 2-24-0
C10 EM2040 SINGLE SLIM PU / ESB RJ45 / ETH6 IMU ROOM 2-24-0 EM2040 RX TRANSDUCER DIL8M EM2040 CASING ETHERNET SWE TRANSDUCER CABLE 15 KONGSBERG
C11 EM2040 SINGLE SLIM PU / ESB RJ45 / ETH8 IMU ROOM 2-24-0 EM2040 SINGLE SLIM PU /
CBMF RJ45/ETH1 IMU ROOM 2-24-0 ETHERNET SWE ETHERNET CABLE 15 KONGSBERG
C12 EM2040 SINGLE SLIM PU / ESB RJ45 / CPU3 IMU ROOM 2-24-0 POS/MV RJ45 COMP LAB 1-38-2 ATTITUDE VELOCITY CAT6 LSZH 4 TWISTED PAIRS 100 CFE
C13 EM2040 SINGLE SLIM PU / CBMF BNC / 1PPS IMU ROOM 2-24-0 POS/MV BNC COMP LAB 1-38-2 1PPS RJ59 COAX COAX 30 CFE
C14 EM2040 SINGLE SLIM PU / POWER IEC320 IMU ROOM 2-24-0 SHIP'S POWER - CIRCUIT TBD NEMA 5-15 IMU ROOM 2-24-0 115 VAC SWE AC POWER CORD N/A KONGSBERG
C15 EM2040 SINGLE SLIM PU / POWER LUGS IMU ROOM 2-24-0 SHIP GROUND LUGS IMU ROOM 2-24-0 GROUND BRAID BRAID 0.5 KONGSBERG
C16 EM2040 TX TRANSDUCER MCIL8M EM2040 CASING EM2040 RX TRANSDUCER MCIL4M EM2040 CASING 48VDC / SYNC SOOW 20/5 POWER/SYNC CABLE 1.5 KONGSBERG
C17 SVP-70 S105A062-130 EM2040 CASING SVP-70 JUNCTION BOX DEU105A062-130 IMU ROOM 2-24-0 12/24 VDC RS232 TX/RX SWE POWER/SIGNAL N/A KONGSBERG
C18 SVP-70 JUNCTION BOX TERMINAL BLOCK IMU ROOM 2-24-0 SHIP'S POWER - CIRCUIT TBD IEC320 IMU ROOM 2-24-0 115 VAC CFE POWER N/A CFE
C19 SVP-70 JUNCTION BOX TERMINAL BLOCK IMU ROOM 2-24-0 EM2040 HP HWS DB9-F COMP LAB 1-38-2 SURVACE SV BELDEN 8777SB 3 PAIR, 22AWG 15 CFE
C20 OLEX COMPUTER RJ45 / ETH BRIDGE 03-34-0 EM2040 HP HWS RJ45 / ETH COMP LAB 1-38-2 MULTIBEAM DATA CAT6 Plenum 100 CFE
C21 OLEX COMPUTER RJ45 / SPARE BRIDGE 03-34-0 EM2040 HP HWS NONE BRIDGE 03-34-0 NONE CAT6 Plenum 100 CFE
C22 OLEX COMPUTER RJ45 / SPARE BRIDGE 03-34-0 EM2040 HP HWS NONE BRIDGE 03-34-0 NONE CAT6 Plenum 100 CFE
SP-C9
EM2040 SINGLE SLIM PU / ESB DUMMY PLUG IMU ROOM 2-24-0
EM2040 TX TRANSDUCER DUMMY PLUG EM2040 CASING NONE SWE POWER / ETHERNET CABLE 15 KONGSBERGEM2040 SINGLE SLIM PU / ESB DUMMY PLUG IMU ROOM 2-24-0
EM2040 SINGLE SLIM PU / POWER DUMMY PLUG IMU ROOM 2-24-0
SP-C10 EM2040 SINGLE SLIM PU / ESB DUMMY PLUG IMU ROOM 2-24-0 EM2040 RX TRANSDUCER DUMMY PLUG EM2040 CASING NONE SWE TRANSDUCER CABLE 15 KONGSBERG
SP-C12 EM2040 SINGLE SLIM PU / ESB RJ45 / CPU3 IMU ROOM 2-24-0 POS/MV RJ45 COMP LAB 1-38-2 ATTITUDE VELOCITY CAT6 LSZH 4 TWISTED PAIRS 100 CFE
SP-C13 EM2040 SINGLE SLIM PU / CBMF BNC / 1PPS IMU ROOM 2-24-0 POS/MV BNC COMP LAB 1-38-2 1PPS RJ59 COAX COAX 30 CFE
SP-C17 SVP-70 DUMMY PLUG EM2040 CASING SVP-70 JUNCTION BOX DUMMY PLUG IMU ROOM 2-24-0 NONE SWE POWER/SIGNAL N/A KONGSBERG
CABLE TAG LIST
CABLE
NO. TAG QUANTITY REMARKS
C3 EM2040 HWS AC POWER C-12 AS REQ'D
C7 EM2040 POSMV 1 C-12 AS REQ'D
C8 EM2040 POSMV 2 C-12 AS REQ'D
C9 EM2040 TX PRIMARY 2
C10 EM2040 RX PRIMARY 2
C12 EM2040 POSMV 3 C-12 AS REQ'D
C13 EM2040 POSMV 4 C-12 AS REQ'D
C17 EM2040 SVP-70 JBOX PRIMARY 2
C18 EM2040 SVP-70 SIGNAL C-12 AS REQ'D
C18 EM2040 PU SVP-70 AC POWER C-12 AS REQ'D
C20 EM2040 OLEX 1 C-12 AS REQ'D
C21 EM2040 OLEX 2 SPARE C-12 AS REQ'D
C22 EM2040 OLEX 3 SPARE C-12 AS REQ'D
SP-C10 EM2040 RX SPARE 2
SP-C12 EM2040 POSMV 5 SPARE C-12 AS REQ'D
SP-C13 EM2040 POSMV 6 SPARE C-12 AS REQ'D
SP-C17 EM2040 SVP-70 JBOX SPARE 2
SP-C9 EM2004 TX SPARE 2
C-11 C9
C10
C17
15 (6)
16 (3)
SP-C17
SP-C10
SP-C9
NOTE: CABLE RUN SHEETS ARE DETAILED IN REFERENCE 9.
| Sheets and Views |
| GENERAL NOTES |
| REMOVALS |
| INSTALLATION & WELD DETAILS, EM2040 & FE800 |
| PIPING DETAILS |
| CONDUIT & VENT PIPE ROUTING |
| VENT PIPE ROUTING |
| CABLING DETAILS |