HB-461-001 EM2040 MkII 0.4x0.7 Installation.pdf

PDF 1 MB Posted

Attached to
FY21 Henry Bigelow Drydock Repairs
Solicitation number
1305M220QNMAN0190
Issued by

About this file

This document package includes an engineering drawing set and related federal contract opportunity. The engineering drawing set provides installation details for a 0.4x0.7 EM2040 MkII multibeam echo sounder aboard the NOAA ship Henry Bigelow. It includes general arrangement drawings, scantling details, equipment installation details, piping details, conduit and vent routing diagrams, and cabling details.

The related federal contract opportunity is solicitation number 1305M220QNMAN0190 for FY21 Henry Bigelow drydock repairs from the Department of Commerce National Oceanic and Atmospheric Administration. The scope of work involves structural modifications, equipment installations and other work incidental to installing the 0.4x0.7 EM2040 MkII multibeam echo sounder aboard the NOAA ship Henry Bigelow, as depicted in the engineering drawing set.

View the file

Other files

File Type Posted
Amendment 0003.pdf PDF
(134)Knuckle Boom Crane_Part2.pdf PDF
(134)Knuckle Boom Crane_Part1.pdf PDF
Bigelow Trawl Winch Drawings.pdf PDF
VideoXpert.pdf PDF
HB FY21 Dry Dock Repair Spec_Rev 1.pdf PDF
(012)Centerboard_Rev1.pdf PDF
HB 124931 Cover.pdf PDF
HB310 FRV40 225 041 010 Generator 3 Phase Synchronous.pdf PDF
HB-085 FA02 General Arrangements.pdf PDF
HB-568 (FRV40-225-008-010) Bow Thruster.pdf PDF
HB-300 FE01 Power One Line.pdf PDF
HB-085 FA04 Docking Drawing.pdf PDF
HB-461 FE93 Transducer Arrangement and Installation(1).pdf PDF
VideoXpert Professional v 3 7 Product Specification.pdf PDF
HB167 FH62 STRL Doors Hatches Manholes Scuttles.pdf PDF
HB-512-5010 Assy Unit 5010 HVAC A_D.pdf PDF
AMC 0001F General Requirements for Contract Repair Work on NOAA Ships.pdf PDF
AMC-0001F General Requirements for Contract Repair Work on NOAA Ships.pdf PDF
HB-100 FH68 BERP _ WERP Key Plan and Details.pdf PDF
Appleton Drawing AMD-2129 REV 0 Jib Pin Assembly.pdf PDF
HB FY20 Liferaft Certificates.pdf PDF
Naval Ships Technical Manual 081 Waterborne Underwater Hull Cleaning of Navy Ships.pdf PDF
HB-160 FH19 Centerboard Bottom Void Scantlings(1).pdf PDF
HB 124622 Sleeve Doubler 3inch NPS.pdf PDF
HB-085 FA01 Outboard Profile.pdf PDF
CC-7137_Plan_001.pdf PDF
Amendment 0002.pdf PDF
Air Box and Generator Pictures (1).pdf PDF
P 1097 19 Henry B. Bigelow LeBus Sleeves.pdf PDF
HB 124930 Casing.pdf PDF
Aft Deck Hatch.pdf PDF
Airmar B17-HP Temp Sensor.pdf PDF
HB-160 FH19 Centerboard Bottom Void Scantlings.pdf PDF
HB-461 FE93 Transducer Arrangement and Installation.pdf PDF
HB-461-002 EM2040 Installation Cable Run Sheets.pdf PDF
Standard - MIL-STD-2199A Glass Reinforced Plastic Covering for Propeller Shafts.pdf PDF
MOC-631-2D Coating Systems for Steel Surfaces.pdf PDF
(005)Line Shaft and Thrust Bearing Manual.pdf PDF
AMC-300-1 Overhaul of Electrical Rotating Machinery.pdf PDF
Amendment 0001.pdf PDF
(006)SternTubeBearing and Shaft Seal Resubmittal.pdf PDF
Furuno FE800 Installation Manual.pdf PDF
Airmar Owners Guide _ Installation Instructions - SS577- 33-495-01.pdf PDF
Radial-Rubber-Tile-RBT-Submittal.pdf PDF
MOC-573-2 Overhaul-Repair of Hydraulic Cylinders.pdf PDF
S6900 General Requirement for Electrical-Electronic Items.pdf PDF
MOC-631-3B Underwater Body Ablative Coating System.pdf PDF
(139)Cathelco Antifouling System.pdf PDF
IEEE.pdf PDF
Show 40 more

Latest 50 of 106 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

600mm

AP

100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15

400mm

FP

510 0

BASELINE

FLWL 6.1m

45 45 ofSheet

Rev

Scale

C

A

D

Maritime Systems Division 2750 Prosperity Avenue Suite 600 Fairfax VA 22031

(703) 270 1540

Size

Drawing Title

Drawn by Date Prepared for

Date

Date

Checked by

Approved by

NOAA Office of Marine & Aviation Operations 8403 Colesville Road

Silver Spring MD 20910

B

C

A

D

Drawing Number

THIRD ANGLE PROJECTION

UNLESS OTHERWISE SPECIFIED

DIM ARE IN INCHES

TOL ON ANGLE ± 0.01°

INTERPRET DIM AND TOL PER

ASME Y14.5M-2009

ABS Approval Date

DateUSCG Approval

HULL NUMBER

HB-461-001D

R 225

NOAA SHIP HENRY BIGELOW

SWBS

EM2040 MKII 0.4X0.7 INSTALLATION

D W

G :H

B-

1-

R

EV

GENERAL NOTES

1AS NOTED

NWT 7/9/2020

BILL OF MATERIALS

NO. QTY UNIT MFG# / PART # DESCRIPTION MATERIAL MATL. SPEC. SCE UNIT WT. REMARKS

1 1 EA - 0.4x0.7 EM2040 CASING ASSEMBLY STEEL ABS GRADE A CFM N/A

2 1 EA TX MODULE VARIOUS - CFM N/A

3 1 EA RX MODULE VARIOUS - CFM N/A

4 1 EA GV-200B-8B GATE VALVE VARIOUS - CFM 375 LB INCLUDES HARDWARE, GASKETS, ETC

5 14 FT2 - 1

2" PLATE STEEL ABS GRADE A CFM 20.4 LB/FT2

6 6 FT2 - 3

8" PLATE STEEL ABS GRADE A CFM 15.3 LB/FT2

7 23 FT - 3-1

2" SCH80 PIPE STEEL ASTM A53 CFM 12.5 LB/FT SEAMLESS, BUTT WELDED JOINTS

8 66 FT - 1-1

2" SCH 80 PIPE STEEL ASTM A53 CFM 3.65 LB/FT SEAMLESS, BUTT WELDED JOINTS

9 1/4 FT - 4-1

2" TUBE STEEL ASTM A53 CFM - 1

4" WALL THICKNESS

10 1 EA - 1-1/2" 90° ELBOW STEEL ASTM A234 CFM - SCHED 80, BUTT WELDED

11 5 EA - 1-1/2" LONG RADIUS 90° ELBOW STEEL ASTM A234 CFM - SCHED 80, BUTT WELDED

12 2 EA - 1-1/2" 45° ELBOW STEEL ASTM A234 CFM - SCHED 80, BUTT WELDED

13 1 EA - 1-1/2" 180° RETURN CONNECTOR STEEL ASTM A234 CFM - SCHED 80, BUTT WELDED

14 1 EA - 4" MCT FRAME VARIOUS - CFM 1.1 LB ROXTEC R100 OR EQUIVALENT

15 6 EA RM15 MCT CABLE GLAND MODULE - - CFM - ROXTEC RM15 OR EQUIVALENT

16 3 EA RM15/0 MCT BLANK MODULE - - CFM - ROXTEC RM15/0 OR EQUIVALENT

17 20 EA - 3/8-16 UNC BOLT STAINLESS STEEL TYPE 316 CFM -

18 20 EA - 3/8-16 UNC NUT STAINLESS STEEL TYPE 316 CFM -

19 20 EA - 3

8" WASHER STAINLESS STEEL TYPE 316 CFM -

20 2 FT2 - 5

16" GASKET NEOPRENE - CFM -

No. REFERENCE DWG No.

1 GENERAL ARRANGEMENTS HB-085-FA02 REV. 7

2 HULL MIDBODY SCANTLINGS FR19-FR49 HB-110-FH03 REV. 0

3 VENTS & SOUNDS SYS DIAGRAM HB-506-FP02 REV. 4

4 CASING, 0.7x0.7 EM2040/SVP70, NANCY FOSTER 124930

5 TRANSDUCER INSTALLATION DETAILS HB-169-FH50 REV. 6

6 INSTALLATION MANUAL - NAVIGATIONAL ECHO SOUNDER

MODEL FE-800

7 PAINT SCHEDULE HB-631-FF04 REV. 0

8 STANDARD PIPING DETAILS HB-505-FP25

9 EM2040 INSTALLATION CABLE RUN DETAILS HB-461-002

1 - GENERAL NOTES

2 - REMOVALS

3 - INSTALLATION & WELD DETAILS, EM2040 & FE800

4 - PIPING DETAILS

5 - CONDUIT & VENT PIPE ROUTING

6 - VENT PIPE ROUTING

7 - CABLING DETAILS

CABLE INSTALLATION NOTES

C-1 CABLES ARE GFE, FOR CABLE LIST SEE SHEET 7

C-2 PROTECT WET AND DRY SIDE CONNECTORS SO TO

NOT DAMAGE DURING INSTALLATION

C-3 CABLES WILL NEED TO BE PULLED IN SEQUENCE

FOR PROPER FIT IN CONDUIT

C-4 FOR ALL CABLE RUNS TO LOCATIONS NOT SHOWN

ON THIS DRAWING, USE EXISTING CABLEWAYS

AND PATHS UNLESS DIRECTED OTHERWISE BY

KONGSBERG

C-5 KONGSBERG ENGINEER SHALL EXAMINE PATH

AND RECOMMEND CHANGES BASED ON

PROXIMITY TO CABLES THAT MIGHT CAUSE

ELECTRICAL INTERFERENCE

C-6 PULL CABLES BY HAND ONLY

C-7 PULL CABLES FROM WET SIDE TO DRY SIDE

C-8 PULL CABLES UNDER THE DIRECTION OF THE

ON-SITE KONGSBERG ENGINEER OR COR

C-9 EXISTING ABOVE-DECK EQUIPMENT POWER AND

INTERFACE WILL BE UTILIZED. KONGSBERG

ENGINEER WILL MAKE OR MODIFY THESE

CONNECTIONS IF NECESSARY TO CONNECT /

INTERFACE TO THE EQUIPMENT

C-10 INSTALLING ACTIVITY SHALL PROVIDE CABLE TAGS

FOR ALL CABLES. SEE SHEET 7 FOR CABLE TAG

DETAILS

C-11 CABLE TAGS SHALL BE STAMPED WITH 12" INCH

LETTERING AND MADE FROM 304 OR 316

STAINLESS STEEL

C-12 CABLE TAGS SHALL BE INSTALLED WITHIN 1' OF

ALL TERMINATIONS AND WITHIN 1' OF EACH SIDE

OF ALL PENETRATIONS

C-13 SPARE CABLING NOTED IN DET 49-A SHALL BE RUN

AS CLOSELY AS POSSIBLE TO CORRESPONDING

PRIMARY CABLING AND COILED NEAR

CORRESPONDING TERMINATION WITH UNUSED

CONNECTION PROTECTED FROM MOISTURE, DIRT,

DUST, GRIME, OR OTHER POSSIBLE DAMAGE

C-14 DUMMY PLUGS SHALL BE INSTALLED ON SPARE TX,

RX, AND SVP CABLING WITHIN EM2040 MkII CASING, AND BE INSTALLED AS TO BE ACCESSIBLE BY

DIVERS.

GENERAL NOTES

1 THIS DRAWING PROVIDES STRUCTURAL MODIFICATION DETAILS INCIDENTAL TO THE

INSTALLATION OF 0.4x0.7 EM2040 MkII MULTIBEAM ECHOSOUNDER ABOARD NOAA SHIP HENRY

BIGELOW

2 INSTALLATION OF GATE VALVE INCIDENTAL TO RELOCATION OF FE800 TRANSDUCER SHALL BE IN

ACCORDANCE WITH REF. 4

3 ALL NEW STEEL SHALL BE ABS GRADE A UNLESS NOTED OTHERWISE.

4 ALL WELDING, WORKMANSHIP, AND MATERIALS, SHALL BE IN ACCORDANCE WITH USCG AND ABS

REGULATIONS.

5 ALL STRUCTURAL DETAILS AND GENERAL NOTES NOT SHOWN ON THIS DRAWING SHALL BE IN

ACCORDANCE WITH REF 2.

SHARP OR ROUGH EDGES OF EXPOSED WORK SHALL BE GROUND SMOOTH TO PREVENT INJURY

TO PERSONNEL OR DAMAGE TO EQUIPMENT.

6 NEW METAL SHALL BE BLASTED TO SSPC-SP-10 NEAR WHITE AND PRIMED WITH INORGANIC ZINC

WELD THROUGH SHIP PRIMER. WELDS AND DAMAGED AREAS SHALL BE SPOT BLASTED AND

REPRIMED.

7 COATINGS SHALL BE APPLIED TO MATCH SURROUNDING AREAS IN ACCORDANCE WITH REF. 7

8 BULKHEAD AND DECK PENETRATIONS SHALL BE MADE THROUGH THE USE OF APPROVED

STUFFING TUBES OR TRANSIT DEVICES WHICH WILL MAINTAIN THE WATERTIGHT, FIRE TIGHT, OR

SMOKE TIGHT (AS APPLICABLE) INTEGRITY OF THE BULKHEADS OR DECK

9 PHILLY BOND FAIRING COMPOUND SHALL BE APPLIED AS SHOWN IN REF. 5 DETAIL 31-B AT 5:1

SLOPE TO CREATE A STREAMLINED TAPER & PREVENT THE WATER FLOW FROM TRIPPING.

PHILLY BOND FAIRING COMPOUND SHALL BE GROUND TO OBTAIN A 250 MICRO-INCH SURFACE

FINISH.

10 MATERIAL LENGTHS ARE APPROXIMATE. EXACT LENGTHS FOR INSTALLATION SHALL BE

MEASURED FROM THE SHIP AND EQUIPMENT, AS NECESSARY.

11 PIPE ROUTING IS APPROXIMATE. EXACT ROUTING MUST BE VERIFIED AND TARGETED BY

CONTRACTOR BEFORE INSTALLATION.

MESSROOM 1-19-0

PASSAGE 2-29-0 & SR 2-34-3

TRANSDUCER ROOM 4-34-0

KEY 3-B

SCALE: 1

512" = 1'

AREAS OF WORK

APPROVEDDATEDESCRIPTIONREV

REVISION HISTORY

ZONE

DRAWING INDEX

SHT REV TITLE

AutoCAD SHX Text

HAUL

24 25 26 27 28

FWD

PLAN 10-A

SHELL PLATING REMOVALS

TRANSDUCER ROOM 4-23-0

37 12"x4"x3

4" FLG PL (E)

ofSheet

Rev

Scale

B

C

A

D

Size

Sheet Title

Drawing Number

D HB-461-001

B

C

A

D

REMOVALS

21/32" = 1'

AB

R1

R2

Ø12

37 12"x4"x3

4" FLG PL (E)

SECTION 13-B

FRAME 27 REMOVALS

SECTION 13-A

FRAME 26 REMOVALS

℄1

2" GUSSET PL (REMOVE)

2" GUSSET PL (REMOVE)

PASSIVE SONAR (E)

SPEED LOG (E)

FE800

XDCR (E)

SELF-NOISE

HYDROPHONE (E)

x3 x5 16 F

LG

P

L (T

YP

37 12 x 4 x 34" FLG PL

24 25 26 27 28 ofSheet

Rev

Scale

B

C

A

D

Size

Sheet Title

Drawing Number

D HB-461-001

B

C

A

D

INSTALL. & WELD DETAILS, EM2040 & FE800

31/32" = 1'

FWD℄

PLAN 18-A

INSTALLATIONS

TRANSDUCER ROOM 4-23-0

SELF-NOISE

HYDROPHONE (E)

PASSIVE

SONAR (E)

SPEED

LOG (E)

R2

FE800 XDCR (E) &

GATE VALVE (N)

B

B25

SECTION 17-C

FE800 XDCR & GATE VALVE INSTALLATION

SCALE: 1

16" = 1'

FE800 XDCR (E)

FAIRING COMPOUND, SEE G.N. 9

FAIRING COMPOUND, SEE G.N. 9

SEE REF 6 FOR VALVE

INSTALLATION DETAILS

CA

SECTION 21-B

CASING COLLAR INSTALLATION - FR 27

SECTION 21-A

CASING COLLAR INSTALLATION - FR 26

DETAIL 19-C

FRAME 26 COLLAR

SCALE: 1

16" = 1'

DETAIL 22-C

FRAME 27 COLLAR

SCALE: 1

16" = 1'

1 4

Ø2Ø2

4° 4°

31 31

8 95

81 2 91 8

3/8

FP

3/8

TYP

22-C

3/8

3/8

3/8

TYP

19-C

3/8

3/8

1 2

12 12 12 ofSheet

Rev

Scale

B

C

A

D

Size

Sheet Title

Drawing Number

D HB-461-001

B

C

A

D

PIPING DETAILS

41/16" = 1'

SECTION 25-B

EM2040 CASING COLLAR INSTALLATION

10"x3"x 5

16" FLG PL (E)

DETAIL 27-D

PIPE COLLAR INSTALLATION

SCALE: 18" = 1'

DETAIL 26-D

PIPE COLLAR DETAIL

SCALE: 18" = 1'

D

81 2 31 241 2

SECTION 25-D

DETAIL 29-C

VENT PIPE NON-TIGHT

PENETRATION

C

SECTION 28-C

DETAIL 29-B

VENT PIPE WATERIGHT / FLAMETIGHT

PENETRATION

DETAIL 32-B

VENT BOX

B

SECTION 31-B

71 2

DETAIL 32-D

ACCESS PLATE

Ø13

R21

R1

TOP, BOTTOM,

SIDES

26-C

1/2

CP

1/2

CP6

21-B

21-A

1/8

CP

3/16

CP

5/16

TYP

32-D

TYP

5/16

CP

3/8

CP

3/8

CP

27-D

NOTE: INSTALL BOLT

HOLES TO ALIGN

WITH COVER PLATE

25 20

25 20

25 20 ofSheet

Rev

Scale

B

C

A

D

Size

Sheet Title

Drawing Number

D HB-461-001

B

C

A

D

CONDUIT & VENT ROUTING

51/64" = 1'

ELEVATION 33-A

CONDUIT & VENT ROUTING

TANK TOP

2ND DECK

MAIN DECK

01 DECK

1 2

1 4

33 A

1 2

3 4

PLAN 36-A

CONDUIT ROUTING

TANK TOP

PLAN 38-A

CONDUIT ROUTING

INNERBOTTOM

R24

R24

4 153

1 2

32-B

53-B

29-B

29-C

29-B

THRU

PASS

THRU

PASS

FT

DN

W

T ofSheet

Rev

Scale

B

C

A

D

Size

Sheet Title

Drawing Number

D HB-461-001

B

C

A

D

VENT PIPE ROUTING

61/64" = 1'

PLAN 44-C

VENT ROUTING

MAIN DECK

PLAN 41-C

VENT ROUTING

01 DECK

ELEVATION 41-B

CONDUIT & VENT ROUTING

VIEW LOOKING AFT

ELEVATION 41-C

CONDUIT & VENT ROUTING

VIEW LOOKING AFT

PLAN 46-B

VENT ROUTING

2ND DECK

C

B

1 2

47 8

MN DK

01 DK

47 8

1 4

1 2

5 8

1 2

PASSAGE

2-29-0

SR (2)

2-34-2

MESSROOM

1-19-0

SR (2)

01-24-4

SR (2)

01-19-2

MN DK

01 DK

7/

C1 AC IN C2

MONITOR

#1

KEYBOARD

C4

MOUSE

C5

C17

NETB

C2

C5

C4

C6

USB

DVI

USB

NETA

EM2040

HP HWS

COM

AC IN C3

C19

C17

(CFE)

SVP-70

SVP-70

JUNCTION

BOX C18 C18 MISSION UPS

EM 2040 SINGLE SLIM PU

CONSOLE

(G G

A/ZD

A)

(ATTITU

D

E)

C7

C8

PORT1

PORT2

PORT3

PORT4

ETH0

ETH1

ETH2

ETH3

ETH4

SYNC

CBMF

EM 2040

BOARD

100-250

VAC

POWER

GROUND

CONCURRENT

CPU

BOARD

ETH1

ETH2

USB0

USB2

USB1

ETHERNET

SWITCH

BOARD

ETH5

ETH6

ETH7

ETH8

CPU3

1PPS

ETH1

ETH2

48VDC

OUT

48VDC

OUT

C6

C11

C10

C12

C11

(ATTITU

D

E VELO

C

ITY)

(1PPS)

EM2040

TX

TRANSDUCER

C9

C16

EM2040

RX

TRANSDUCER

C16

C10

PASSAGEWAY 2-24-0

ME70 RACK - BOTTOM

COMPUTER LAB 1-38-2

POSMV

C12

C13

SPARE

C7

C8

SPARE

SPAR

E

SP-C12

SP-C12

SP-C13

SP-C13

SPAR

E

C13

C3 MISSION UPS

C19

C14 MISSION UPS

C10

HULL-MOUNTED EM2040 CASING

COM

OLEX

COMPUTER

COM

COM

BRIDGE 03-34-0

COM C20

C1MISSION UPS

SP-C10

SP-C10

SP-C17

C17

SP-C9

C9

C17

SP-C17

C9

SP-C9

C20

C21

C22

C14

C15 C15

C18

C19 ofSheet

Rev

Scale

B

C

A

D

Size

Sheet Title

Drawing Number

D HB-461-001

B

C

A

D

CABLING DETAILS

7NOT TO SCALE

DETAIL 49-A

CABLE DIAGRAM

DETAIL 53-B

MCT ARRANGEMENT

CABLE PLAN

CABLE

NO.

FROM TO

SIGNAL CABLE TYPE CABLE DESCRIPTION

IEEE MAX

CABLE

LENGH

SOURCE

DEVICE CONNECTOR TYPE /

PORT DESCRIPTION LOCATION DEVICE

CONNECTOR

TYPE / PORT

DESCRIPTION

LOCATION

C1 MONITOR #1 IEC320 COMP LAB 1-38-2 SHIP'S POWER - CIRCUIT TBD NEMA 5-15 COMP LAB 1-38-2 115 VAC SWE AC POWER CORD N/A KONGSBERG

C2 MONITOR #1 DVI COMP LAB 1-38-2 EM2040 HP HWS DVI COMP LAB 1-38-2 VIDEO SWE VIDEO CABLE N/A KONGSBERG

C3 EM2040 HP HWS IEC320 COMP LAB 1-38-2 SHIP'S POWER - CIRCUIT TBD NEMA 5-15 COMP LAB 1-38-2 115 VAC SWE AC POWER CORD N/A KONGSBERG

C4 EM2040 HP HWS USB COMP LAB 1-38-2 KEYBOARD MOLDED COMP LAB 1-38-2 KEYBOARD SWE KEYBOARD N/A KONGSBERG

C5 EM2040 HP HWS USB COMP LAB 1-38-2 MOUSE MOLDED COMP LAB 1-38-2 MOUSE SWE MOUSE N/A KONGSBERG

C6 EM2040 HP HWS RJ45 / NET A COMP LAB 1-38-2 EM2040 SINGLE SLIM PU / CCB RJ45/ETH1 COMP LAB 1-38-2 ETHERNET SWE 4 TWISTED PAIRS 100 KONGSBERG

C7 EM2040 SINGLE SLIM PU / CCB RJ45 / PORT1 IMU ROOM 2-24-0 POS/MV DB9-F COMP LAB 1-38-2 GGX/ZDA CAT6 LSZH 4 TWISTED PAIRS 100 CFE

C8 EM2040 SINGLE SLIM PU / CCB RJ45 / PORT2 IMU ROOM 2-24-0 POS/MV DB9-F COMP LAB 1-38-2 ATTITUDE CAT6 LSZH 4 TWISTED PAIRS 100 CFE

C9

EM2040 SINGLE SLIM PU / ESB RJ45 / ETH2 IMU ROOM 2-24-0 EM2040 TX TRANSDUCER DIL13M EM2040 CASING 48VDC / ETHERNET SWE POWER / ETHERNET CABLE 15 KONGSBERG

EM2040 SINGLE SLIM PU / ESB RJ45 / ETH4 IMU ROOM 2-24-0

EM2040 SINGLE SLIM PU / POWER THREE LEMO / 48VDC IMU ROOM 2-24-0

C10 EM2040 SINGLE SLIM PU / ESB RJ45 / ETH6 IMU ROOM 2-24-0 EM2040 RX TRANSDUCER DIL8M EM2040 CASING ETHERNET SWE TRANSDUCER CABLE 15 KONGSBERG

C11 EM2040 SINGLE SLIM PU / ESB RJ45 / ETH8 IMU ROOM 2-24-0 EM2040 SINGLE SLIM PU /

CBMF RJ45/ETH1 IMU ROOM 2-24-0 ETHERNET SWE ETHERNET CABLE 15 KONGSBERG

C12 EM2040 SINGLE SLIM PU / ESB RJ45 / CPU3 IMU ROOM 2-24-0 POS/MV RJ45 COMP LAB 1-38-2 ATTITUDE VELOCITY CAT6 LSZH 4 TWISTED PAIRS 100 CFE

C13 EM2040 SINGLE SLIM PU / CBMF BNC / 1PPS IMU ROOM 2-24-0 POS/MV BNC COMP LAB 1-38-2 1PPS RJ59 COAX COAX 30 CFE

C14 EM2040 SINGLE SLIM PU / POWER IEC320 IMU ROOM 2-24-0 SHIP'S POWER - CIRCUIT TBD NEMA 5-15 IMU ROOM 2-24-0 115 VAC SWE AC POWER CORD N/A KONGSBERG

C15 EM2040 SINGLE SLIM PU / POWER LUGS IMU ROOM 2-24-0 SHIP GROUND LUGS IMU ROOM 2-24-0 GROUND BRAID BRAID 0.5 KONGSBERG

C16 EM2040 TX TRANSDUCER MCIL8M EM2040 CASING EM2040 RX TRANSDUCER MCIL4M EM2040 CASING 48VDC / SYNC SOOW 20/5 POWER/SYNC CABLE 1.5 KONGSBERG

C17 SVP-70 S105A062-130 EM2040 CASING SVP-70 JUNCTION BOX DEU105A062-130 IMU ROOM 2-24-0 12/24 VDC RS232 TX/RX SWE POWER/SIGNAL N/A KONGSBERG

C18 SVP-70 JUNCTION BOX TERMINAL BLOCK IMU ROOM 2-24-0 SHIP'S POWER - CIRCUIT TBD IEC320 IMU ROOM 2-24-0 115 VAC CFE POWER N/A CFE

C19 SVP-70 JUNCTION BOX TERMINAL BLOCK IMU ROOM 2-24-0 EM2040 HP HWS DB9-F COMP LAB 1-38-2 SURVACE SV BELDEN 8777SB 3 PAIR, 22AWG 15 CFE

C20 OLEX COMPUTER RJ45 / ETH BRIDGE 03-34-0 EM2040 HP HWS RJ45 / ETH COMP LAB 1-38-2 MULTIBEAM DATA CAT6 Plenum 100 CFE

C21 OLEX COMPUTER RJ45 / SPARE BRIDGE 03-34-0 EM2040 HP HWS NONE BRIDGE 03-34-0 NONE CAT6 Plenum 100 CFE

C22 OLEX COMPUTER RJ45 / SPARE BRIDGE 03-34-0 EM2040 HP HWS NONE BRIDGE 03-34-0 NONE CAT6 Plenum 100 CFE

SP-C9

EM2040 SINGLE SLIM PU / ESB DUMMY PLUG IMU ROOM 2-24-0

EM2040 TX TRANSDUCER DUMMY PLUG EM2040 CASING NONE SWE POWER / ETHERNET CABLE 15 KONGSBERGEM2040 SINGLE SLIM PU / ESB DUMMY PLUG IMU ROOM 2-24-0

EM2040 SINGLE SLIM PU / POWER DUMMY PLUG IMU ROOM 2-24-0

SP-C10 EM2040 SINGLE SLIM PU / ESB DUMMY PLUG IMU ROOM 2-24-0 EM2040 RX TRANSDUCER DUMMY PLUG EM2040 CASING NONE SWE TRANSDUCER CABLE 15 KONGSBERG

SP-C12 EM2040 SINGLE SLIM PU / ESB RJ45 / CPU3 IMU ROOM 2-24-0 POS/MV RJ45 COMP LAB 1-38-2 ATTITUDE VELOCITY CAT6 LSZH 4 TWISTED PAIRS 100 CFE

SP-C13 EM2040 SINGLE SLIM PU / CBMF BNC / 1PPS IMU ROOM 2-24-0 POS/MV BNC COMP LAB 1-38-2 1PPS RJ59 COAX COAX 30 CFE

SP-C17 SVP-70 DUMMY PLUG EM2040 CASING SVP-70 JUNCTION BOX DUMMY PLUG IMU ROOM 2-24-0 NONE SWE POWER/SIGNAL N/A KONGSBERG

CABLE TAG LIST

CABLE

NO. TAG QUANTITY REMARKS

C3 EM2040 HWS AC POWER C-12 AS REQ'D

C7 EM2040 POSMV 1 C-12 AS REQ'D

C8 EM2040 POSMV 2 C-12 AS REQ'D

C9 EM2040 TX PRIMARY 2

C10 EM2040 RX PRIMARY 2

C12 EM2040 POSMV 3 C-12 AS REQ'D

C13 EM2040 POSMV 4 C-12 AS REQ'D

C17 EM2040 SVP-70 JBOX PRIMARY 2

C18 EM2040 SVP-70 SIGNAL C-12 AS REQ'D

C18 EM2040 PU SVP-70 AC POWER C-12 AS REQ'D

C20 EM2040 OLEX 1 C-12 AS REQ'D

C21 EM2040 OLEX 2 SPARE C-12 AS REQ'D

C22 EM2040 OLEX 3 SPARE C-12 AS REQ'D

SP-C10 EM2040 RX SPARE 2

SP-C12 EM2040 POSMV 5 SPARE C-12 AS REQ'D

SP-C13 EM2040 POSMV 6 SPARE C-12 AS REQ'D

SP-C17 EM2040 SVP-70 JBOX SPARE 2

SP-C9 EM2004 TX SPARE 2

C-11 C9

C10

C17

15 (6)

16 (3)

SP-C17

SP-C10

SP-C9

NOTE: CABLE RUN SHEETS ARE DETAILED IN REFERENCE 9.

Sheets and Views
GENERAL NOTES
REMOVALS
INSTALLATION & WELD DETAILS, EM2040 & FE800
PIPING DETAILS
CONDUIT & VENT PIPE ROUTING
VENT PIPE ROUTING
CABLING DETAILS

File details come from the government source that posted it. Updated .