Thunderbird Environmental, LLC
Clinton, Connecticut - Bozeman, Montana Phone: 860.227.4714 - darby@tbirdenv.com - A Service Disabled Veteran Owned Business
THUNDERBIRD ENVIRONMENTAL, LLC
February 10, 2020
USDA-NRCS Connecticut State Office 344 Merrow Road, Suite A Tolland, Connecticut 06084
Attn: Kristin Walker, Civil Engineer
RE: Hazardous Materials Survey Report 25 3rd Avenue Ext., West Haven, Connecticut
Dear Ms. Walker:
Thunderbird Environmental, LLC (Thunderbird) is pleased to submit this hazardous materials survey report to the Natural Resources Conservation Service (NRCS) for the above referenced property located at 25 3rd Avenue Extension in West Haven, Connecticut (herein after referred to as “the Site”). This report presents the findings of our property inspection and summarizes the observed presence of potentially hazardous/regulated substances including: asbestos containing materials (ACM), lead-based paint, heating oil tanks, mercury and polychlorinated biphenyl (PCB) containing materials, pressure treated wood, mold, and other miscellaneous hazardous materials (paint, automotive fluids, household cleaners, etc.). In addition, Thunderbird contracted laboratory analysis of potential ACM and lead-based paint. This report also provides estimated quantities of hazardous/regulated substances, but does not quantify removal/disposal costs.
1.0 Site Description
The Site is comprised of an approximately 0.13-acre residential property located on the southeast side of 3rd Avenue Ext. in West Haven, Connecticut (Figure 1). The site includes an approximately 2,544 square-foot, two-story residence with an unfinished basement. According to the City of West Haven Tax Assessor’s database, the building was constructed in 1920.
The site building is divided into two separate residential apartments including one on the first floor and one on the second floor. The building is constructed with wood framing on a mortared concrete block and stone foundation. The exterior is clad with vinyl siding over wood siding. The basement contained one, recently-installed gas-fired boiler (see photos) and miscellaneous maintenance-related containers as further described in this report. The first floor apartment includes two bedrooms, one bathroom, a kitchen, and a living room. The second floor apartment includes one bedroom, one bathroom, a galley kitchen and a living room.
2.0 Asbestos Survey
Thunderbird completed an asbestos survey of the site building on January 8, 2020. The survey was performed by Martin Brogie, LEP, licensed as an Asbestos Inspector by the Connecticut Department of
Public Health (Certificate Number 275).
The survey consisted of a National Emissions Standards for Hazardous Air Pollutants (NESHAP) assessment that included a thorough inspection of the subject building components/areas in which the location and number of samples collected, using limited destructive testing, provided sufficient detail to estimate the quantity and location of ACM located in the study areas. The federal NESHAP sampling protocols (40 CFR
61.145), utilized for the asbestos assessment of structures, equipment and buildings to be demolished, requires the following:
“…the owner or operator of a demolition or renovation activity and prior to the commencement of the demolition or renovation, thoroughly inspect the affected facility or part of the facility where the demolition or renovation operation will occur for the presence of asbestos…”
The intent of these federal regulations is to require suspect ACM which will be disturbed during the demolition or renovation (including repair), be assessed for asbestos content (defined as greater than 1% asbestos) and, if identified, be removed and disposed of properly. The asbestos survey utilized both statistically random and discrete sampling procedures during the assessment to find safely accessible sampling locations as well as ensuring that as many suspect building materials were sampled as possible.
Samples were collected using a utility knife and other hand tools which were decontaminated in between samples to avoid cross-contamination. Collected samples were placed in plastic sample bags, labeled with a unique identification number, documented in field notes and on the chain-of-custody documents. Upon completion of sampling activities, field renderings of the survey areas were created which displayed the sample locations. Samples were shipped under chain of custody to International Asbestos Testing
Laboratories, Inc. in Mount Laurel New Jersey for asbestos analysis (Polarized Light Microscopy).
Sampling locations are depicted Figures 2A, 2B, 2C, and 2D. Copies of the laboratory analytical reports are provided as Attachment A. Select photos are included as Attachment B. The table below summarizes the sampled materials and the asbestos analysis results.
TABLE 1
Asbestos Sampling Summary
25 3rd Avenue Ext., West Haven, CT
Sample I.D. Location - Material Asbestos Content
Estimated
ACM
Quantity AS-1 Basement/West Flue- Cement ND AS-2 Basement/East Flue- Cement ND AS-3 1st Floor Living Room- Joint Compound ND AS-4 1st Floor Living Room- Sheetrock ND AS-5 Kitchen 1st Floor- Tan 12" Floor Tile Top
Layer
ND
AS-6 Kitchen 1st Floor- Light Yellow Linoleum 2nd Layer Below
ND
AS-7 1st Floor Kitchen- Tan Linoleum With Black Backer Below 3/4" Particle Board
ND
AS-8 Bedroom 1- Joint Compound ND AS-9 Bedroom 1- Sheetrock ND AS-10 Bedroom 1- Dark Brown Linoleum With
Black Backer Below Particle Board And Plywood
1.8% Chrysotile 120 s.f.
AS-11 Bedroom 2- Brown Floor Tile With Black Backer Below Plywood And Sheetrock
2.2% Chrysotile 120 s.f.
AS-12 Bedroom 2- Sheetrock Below Plywood Floor
ND
AS-13 1st Floor Kitchen- Joint Compound ND AS-14 1st Floor Kitchen- Sheetrock ND AS-15 1st Floor Bathroom- 12" Brown Ceramic
Tile
ND
AS-16 1st Floor Bathroom- Dark Brown Tile Grout
ND
AS-17 1st Floor Bathroom- Ceramic Tile Cement
ND
AS-18 1st Floor Bathroom- Ceramic Tile Backer Board
ND
AS-19 2nd Floor Bedroom- Joint Compound ND AS-20 2nd Floor Bedroom- Sheetrock ND AS-21 2nd Floor Living Room- Joint Compound ND AS-22 2nd Floor Living Room- Sheetrock ND AS-23 2nd Floor Kitchen- 16x16 Light Brown
Ceramic Tile With White Leveling Compound
ND
AS-24 2nd Floor Kitchen- Dark Brown Grout ND
TABLE 1 (continued) Asbestos Sampling Summary
25 3rd Avenue Ext., West Haven, CT
Sample I.D. Location - Material Asbestos Content
Estimated
ACM
Quantity AS-25 2nd Floor Bathroom- Joint Compound ND AS-26 2nd Floor Bathroom- Sheetrock ND AS-27 2nd Floor Bathroom- 16x16 Ceramic Tile ND AS-28 2nd Floor Bathroom- Tan Ceramic Tile
Grout
ND
AS-29 2nd Floor Bathroom- Tan Grout Cement ND AS-30 2nd Floor Bathroom- Grey Backer Board ND AS-31 Hallway- Joint Compound ND AS-32 Hallway- Sheetrock ND AS-33 1st Floor Stairwell Landing- Grey 4"
Floor Tile With Orange Mastic
ND
AS-34 1st Floor Stairwell Landing- White Ceramic Tile With White Leveler
ND
AS-35 1st Floor Stairwell Landing- 1" Pink Ceramic Tile With Tan Mastic
ND
AS-36 1st Floor Stairwell Landing- Grey Leveler ND AS-37 Exterior Basement Window- Caulk ND AS-38 Exterior Porch Window Frame- Caulk ND AS-39 Rear Portion Of House- Black Tar Paper
Under Vinyl Siding
ND
AS-40 Main Roof South Side- Grey Shingle ND AS-41 1st Floor Roof East Side- Grey Shingle ND Notes:
1. ND - No asbestos detected
2. s.f. - square feet
3. P.C. – Asbestos Content by Point Count Method
Asbestos was detected in two (2) materials sampled throughout the residence including: Dark Brown Linoleum With Black Backer Below Particle Board And Plywood (Bedroom 1) and Brown Floor Tile With Black Backer Below Plywood And Sheetrock (Bedroom 1).
The estimated ACM quantity for the Site is 240 square feet.
No samples were collected from the single, gas-fired boiler as it appeared to be very recently installed.
No suspect ACMs were noted in association with the boiler other than flue cement.
Asbestos abatement will be necessary prior to building demolition.
3.0 Lead-Based Paint Testing
The disposal of building materials requires appropriate sampling methods to correctly characterize the proportion and makeup of representative building materials that will be removed during demolition. The Connecticut Department of Energy and Environmental Protection (DEEP) has released a method that states samples for waste characterization are to be representative of the percentage of each building material as it makes up the building. For example, if the building is 50 percent brick, 40 percent concrete, 5 percent wood, and 5 percent metal. The representative 100 gram collected sample would be the same makeup percentage.
Thunderbird staff collected a representative sample of the building at the Site for waste characterization.
The sample was tested for leachable lead via the Toxicity Characteristic Leaching Procedure (TCLP) analysis method as required for waste disposal approval. The sample was a composite of concrete, wood, metal, glass, paint, and other building materials that were in representative portion to their total makeup of the entire building. Based on the TCLP analytical results, leachable lead was not reported in the sample above the laboratory method detection limit of 0.10 milligrams per liter (mg/L) and solid waste debris derived from the demolition of the site building would not be classified as hazardous waste due to lead content.
4.0 Aboveground Storage Tanks (ASTs) and Underground Storage Tanks (USTs)
According to the City of West Haven Tax Assessor’s database, the Site building is heated with natural gas.
A gas-fired boiler was observed in the basement. The boiler appeared to be less than five years old. No fill or vent pipes were observed along the exterior of the Site building.
5.0 Mercury and PCB Containing Materials
As part of the Site inspection on January 8, 2020, Thunderbird observed a thermostat within in the second floor living room. The thermostat has the potential to contain minimal amounts of liquid mercury. There was no other evidence of potential mercury containing material at the Site.
Thunderbird did not observe any potential PCB containing material at the Site.
6.0 Pressure Treated Wood
Pressure treated wood was present at the entrances to both floors of the building. The first floor porch is constructed of pressure treated wood and is approximately 30 s.f. The second story porch is also constructed of pressure treated wood and is approximately 6 s.f.
7.0 Mold
No significant mold was noted in the site building.
8.0 Other Potentially Hazardous Material
Several cans of tile adhesive and paint were observed in the attic.
9.0 Conclusions and Recommendations
Thunderbird Environmental, LLC (Thunderbird) has performed a pre-demolition hazardous materials assessment for the property located at 25 3rd Avenue Extension in West Haven, Connecticut. The assessment included an asbestos survey, lead-based paint sampling, and an evaluation of the presence of other miscellaneous hazardous/regulated materials that may require special disposal or handling prior to, or during demolition.
Based on the findings of the survey, asbestos abatement is required prior to building demolition.
Miscellaneous household/maintenance chemicals and paints should be removed from the residence and disposed and/or recycled prior to demolition. The amount of household/maintenance materials requiring removal is not anticipated to exceed 100 kilograms.
Based on the TCLP analytical results, leachable lead was not reported in the sample above the laboratory method detection limit of 0.10 milligrams per liter (mg/L) and solid waste debris derived from the demolition of the site building would not be classified as hazardous waste due to lead content.
In accordance with Connecticut Department of Energy and Environmental Protection (DEEP) guidelines, disposal of the pressure treated wood should be handled as follows:
• Contractors, utilities, and manufactures should contract directly with a DEEP permitted bulky waste landfill, or send it to an out-of-state wood burner facility.
The identified thermostat should be disposed of in accordance with Connecticut Public Act 12-54.
Dust control measures should be implemented when handling demolition debris.
10.0 Limitations
Suspected ACM observed during the hazardous materials survey were sampled and analyzed for asbestos.
While our inspections are comprehensive, there may be limited areas, such as areas between walls and beneath structures, which were inaccessible and therefore not inspected or tested.
All estimates of materials provided are based on our observations made at the time of our inspection and should be confirmed by abatement contractors.
We appreciate the opportunity to assist NRCS with this project. If you have any questions or comments, please contact us at 860-227-4714.
Sincerely, Darby W. Hittle, L.E.P. Martin Brogie, L.E.P.
Principal / Owner Asbestos Inspector License No. 00275
Figures Attachment A – Laboratory Analytical Reports Attachment B – Select Site Photographs
FIGURES
25 Third Ave Ext.
0.13 Ac.
2nd 1st
Be ac h 3rd Avenue
Midd le
West Haven
Legend Haz-Mat Assessed Property
Streets
Location Map 25 Third Avenue Extension, West Haven, CT µ1 inch = 91 feet
ATTACHMENT A
LABORATORY ANALYTICAL REPORTS
Lab No.: 6949882 Client No.: AS-1
Analyst Observation: Grey Non-Fibrous Client Description: Cement
Location: Basement/West Flue Facility:
Percent Asbestos:
None Detected
Percent Non-Asbestos Fibrous Material:
Percent Non-Fibrous Material:
Different Material analyzed than listed on the sample log.
Lab No.: 6949883 Client No.: AS-2
Analyst Observation: Grey Non-Fibrous Client Description: Cement
Location: Basement/East Flue
Lab No.: 6949884 Client No.: AS-3
Analyst Observation: White Joint Compound Client Description: Joint Compound
Location: 1st Floor Living Room
Lab No.: 6949885 Client No.: AS-4
Analyst Observation: White Drywall Client Description: Sheetrock
Location: 1st Floor Living Room
12 Cellulose
Lab No.: 6949886 Client No.: AS-5
Analyst Observation: Tan/Grey Floor Tile Client Description: Tan 12" Floor Tile Top Layer
Location: Kitchen 1st Floor
Lab No.: 6949886(L2)
Analyst Observation: Clear Mastic
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Client: THU268
Dated : 1/22/2020 9:56:00 Page 1 of 13
Lab No.: 6949886(L3)
Analyst Observation: Brown Wood
85 Cellulose
Lab No.: 6949887 Client No.: AS-6
Analyst Observation: Yellow Vinyl Sheet Flooring Client Description: Light Yellow Linoleum 2nd Layer Below
Location: 1st Floor Kitchen
15 Cellulose 2 Fibrous Glass
Insufficient mastic to analyze
Lab No.: 6949888 Client No.: AS-7
Analyst Observation: Black/Tan Vinyl Sheet Flooring Client Description: Tan Linoleum With Black Backer Below 3/4" Particle Board
20 Cellulose
Lab No.: 6949888(L2) Client No.: AS-7
Analyst Observation: Tan/Green Non-Fibrous Client Description: Tan Linoleum With Black Backer Below 3/4" Particle Board
Lab No.: 6949889 Client No.: AS-8
Location: Bedroom 1
Lab No.: 6949890 Client No.: AS-9
10 Cellulose
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 2 of 13
Lab No.: 6949891 Client No.: AS-10
Analyst Observation: Brown Floor Tile Client Description: Dark Brown Linoleum With Black Backer Below Particle Board And Plywood
PC 1.8 Chrysotile
98.2
Lab No.: 6949891(L2)
Analyst Observation: Black Mastic
Lab No.: 6949891(L3)
Analyst Observation: Black Fibrous Backing
30 Cellulose
Lab No.: 6949892 Client No.: AS-11
Analyst Observation: Brown/Red Floor Tile Client Description: Brown Floor Tile With Black Backer Below Plywood And Sheetrock
Location: Bedroom 2
PC 2.2 Chrysotile
97.8
Lab No.: 6949892(L2) Client No.: AS-11
Analyst Observation: Black/Brown Fibrous Backing Client Description: Brown Floor Tile With Black Backer Below Plywood And Sheetrock
Lab No.: 6949893 Client No.: AS-12
Client Description: Sheetrock Below Plywood Floor
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 3 of 13
Lab No.: 6949894 Client No.: AS-13
Lab No.: 6949895 Client No.: AS-14
Lab No.: 6949896 Client No.: AS-15
Analyst Observation: Tan Ceramic Tile Client Description: 12" Brown Ceramic Tile
Location: 1st Floor Bathroom
Lab No.: 6949897 Client No.: AS-16
Analyst Observation: Brown Grout Client Description: Dark Brown Tile Grout
Lab No.: 6949898 Client No.: AS-17
Analyst Observation: White Mortar Client Description: Ceramic Tile Cement
Lab No.: 6949899 Client No.: AS-18
Analyst Observation: Grey Fiberboard Client Description: Ceramic Tile Backer Board
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 4 of 13
Lab No.: 6949900 Client No.: AS-19
Location: 2nd Floor Bedroom
Lab No.: 6949901 Client No.: AS-20
Location: 2nd Floor Bedroom
Lab No.: 6949902 Client No.: AS-21
Location: 2nd Floor Living Room
Lab No.: 6949903 Client No.: AS-22
Lab No.: 6949903(L2) Client No.: AS-22
Lab No.: 6949904 Client No.: AS-23
Analyst Observation: Brown Ceramic Tile Client Description: 16x16 Light Brown Ceramic Tile With White Leveling Compound
Location: 2nd Floor Kitchen
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 5 of 13
Lab No.: 6949904(L2)
Analyst Observation: White Cementitious
Lab No.: 6949904(L3)
Analyst Observation: Tan Non-Fibrous
Lab No.: 6949905 Client No.: AS-24
Analyst Observation: Brown Grout Client Description: Dark Brown Grout
Lab No.: 6949906 Client No.: AS-25
Location: 2nd Floor Bathroom
Lab No.: 6949907 Client No.: AS-26
Lab No.: 6949907(L2) Client No.: AS-26
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 6 of 13
Lab No.: 6949908 Client No.: AS-27
Analyst Observation: Tan/Red Ceramic Tile Client Description: 16x16 Ceramic Tile
Lab No.: 6949909 Client No.: AS-28
Analyst Observation: Tan Grout Client Description: Tan Ceramic Tile Grout
Lab No.: 6949910 Client No.: AS-29
Analyst Observation: Tan/Grey Mortar Client Description: Tan Grout Cement
2 Fibrous Glass
Lab No.: 6949911 Client No.: AS-30
Analyst Observation: Tan/Grey Cementitious Client Description: Grey Backer Board
Lab No.: 6949911(L2) Client No.: AS-30
Analyst Observation: Clear Fibrous Client Description: Grey Backer Board
95 Fibrous Glass
Lab No.: 6949912 Client No.: AS-31
Location: Hallway
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 7 of 13
Lab No.: 6949913 Client No.: AS-32
10 Cellulose 3 Fibrous Glass
Lab No.: 6949913(L2)
Lab No.: 6949913(L3)
Analyst Observation: Composite
5 Cellulose
Lab No.: 6949914 Client No.: AS-33
Analyst Observation: Grey/Off-White Floor Tile Client Description: Grey 4" Floor Tile With Orange Mastic
Location: 1st Floor Stairwell Landing
Lab No.: 6949914(L2) Client No.: AS-33
Analyst Observation: Clear/Yellow Mastic Client Description: Grey 4" Floor Tile With Orange Mastic
Lab No.: 6949915 Client No.: AS-34
Analyst Observation: White/Brown Ceramic Tile Client Description: White Ceramic Tile With White Leveler
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 8 of 13
Lab No.: 6949915(L2) Client No.: AS-34
Analyst Observation: White Cementitious Client Description: White Ceramic Tile With White Leveler
Lab No.: 6949916 Client No.: AS-35
Analyst Observation: Pink/Grey Ceramic Tile Client Description: 1" Pink Ceramic Tile With Tan Mastic
Lab No.: 6949916(L2) Client No.: AS-35
Analyst Observation: Clear/Tan Mastic/Fibrous Client Description: 1" Pink Ceramic Tile With Tan Mastic
80 Cellulose
Lab No.: 6949917 Client No.: AS-36
Analyst Observation: Grey Cementitious Client Description: Grey Leveler
Lab No.: 6949918 Client No.: AS-37
Analyst Observation: White Caulk Client Description: Caulk
Location: Exterior Basement Window
Lab No.: 6949919 Client No.: AS-38
Analyst Observation: White Caulk Client Description: Caulk
Location: Exterior Porch Window Frame
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 9 of 13
Lab No.: 6949920 Client No.: AS-39
Analyst Observation: Black Tar Paper Client Description: Black Tar Paper Under Vinyl Siding
Location: Rear Portion Of House
Lab No.: 6949921 Client No.: AS-40
Analyst Observation: Grey/Black Shingle Client Description: Grey Shingle
Location: Main Roof South Side
10 Fibrous Glass
Lab No.: 6949922 Client No.: AS-41
Analyst Observation: Grey/Black Shingle Client Description: Grey Shingle
Location: 1st Floor Roof East Side
10 Fibrous Glass
Laboratory Director
Approved By:
Date Analyzed:
1/13/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/20/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC
14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/22/2020 9:56:00 Page 10 of 13
Appendix to Analytical Report Customer Contact:
Method:40 CFR Appendix E to Subpart E of Part 763, interim method for the Determination of Asbestos in Bulk Insulation Samples, and USEPA 600, R93-116 as needed.
This appendix seeks to promote greater understanding of any observations, exceptions, special instructions, or circumstances that the laboratory needs to communicate to the client concerning the above samples. The information below is used to help promote your ability to make the most informed decisions for you and your customers.
Please note the following points of contact for any questions you may have.
iATL Customer Service: customerservice@iatl.com iATL Office Manager:wchampion@iatl.com iATL Account Representative: House Account Sample Login Notes: See Batch Sheet Attached Sample Matrix: Bulk Building Materials Exceptions Noted: See Following Pages
General Terms, Warrants, Limits, Qualifiers:
General information about iATL capabilities and client/laboratory relationships and responsibilities are spelled out in iATL policies that are listed at www.iATL.com and in our Quality Assurance Manual per ISO 17025 standard requirements. The information therein is a representation of iATL definitions and policies for turnaround times, sample submittal, collection media, blank definitions, quantification issues and limit of detection, analytical methods and procedures, sub-contracting policies, results reporting options, fees, terms, and discounts, confidentiality, sample archival and disposal, and data interpretation.
iATL warrants the test results to be of a precision normal for the type and methodology employed for each sample submitted. iATL disclaims any other warrants, expressed or implied, including warranty of fitness for a particular purpose and warranty of merchantability. iATL accepts no legal responsibility for the purpose for which the client uses test results. Any analytical work performed must be governed by our Standard Terms and Conditions. Prices, methods and detection limits may be changed without notification. Please contact your Customer Service Representative for the most current information.
This confidential report relates only to those item(s) tested and does not represent an endorsement by NIST-NVLAP, AIHA LAP LLC, or any agency of local, state or province governments nor of any agency of the U.S. government.
This report shall not be reproduced except in full, without written approval of the laboratory.
Information Pertinent to this Report:
Analysis by US EPA 600 93-116: Determination of Asbestos in Bulk Building Materials by Polarized Light Microscopy (PLM).
Certifications:
NIST-NVLAP No. 101165-0• NYSDOH-ELAP No. 11021• AIHA-LAP, LLC No. 100188•
Quantification at <0.25% by volume is possible with this method. (PC) Indicates Stratified Point Count Method performed. (PC-Trace) means that asbestos was detected but is not quantifiable under the Point Counting regimen. PC Trace represents a <0.25% amount. Analysis includes all distinct separable layers in accordance with EPA 600 Method. If not reported or otherwise noted, layer is either not present or the client has specifically requested that it not be analyzed (ex. analyze until positive instructions). Small asbestos fibers may be missed by PLM due to resolution limitations of the optical microscope. Therefore, PLM is not consistently reliable in detecting asbestos in non-friable organically bound (NOB) materials. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing.
Analytical Methodology Alternatives: Your initial request for analysis may not have accounted for recent advances in regulatory requirements or advances in technology that are routinely used in similar situations for other qualified projects. You may have the option to explore additional analysis for further information. Below are a few options, listed as the matrix followed by the appropriate methodology. Also included are links to more information on our website.
Bulk Building Materials that are Non-Friable Organically Bound (NOB) by Gravimetric Reduction techniques employing PLM and TEM: ELAP 198.6 (PLM-NOB), ELAP 198.4 (TEM-NOB)
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC 14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
Page 11 of 13Dated : 1/22/2020 9:56:01
Loose Fill Vermiculite Insulation, Attic Insulation, Zonolite (copyright), etc.: US EPA 600 R-4/004 (multi-tiered analytical process) Sprayed On Insulation/Fireproofing with Vermiculite (SOF-V): ELAP 198.8 (PLM-SOF-V)
Soil, sludge, sediment, aggregate, and like materials analyzed for asbestos or other elongated mineral particles (ex. erionite, etc.): ASTM D7521, CARB 435, and other options available
Asbestos in Surface Dust according to one of ASTM's Methods (very dependent on sampling collection technique – by TEM): ASTM D 5755, D5756, or D6480
Various other asbestos matrices (air, water, etc.) and analytical methods are available.
Disclaimers / Qualifiers:
There may be some samples in this project that have a "NOTE:" associated with a sample result. We use added disclaimers or qualifiers to inform the client about something that requires further explanation. Here is a list with highlighted disclaimers that may be pertinent to this project. For a full explanation of these and other disclaimers, please inquire at customerservice@iatl.com.
1) Note: No mastic provided for analysis.
2) Note: Insufficient mastic provided for analysis.
3) Note: Insufficient material provided for analysis.
4) Note: Insufficient sample provided for QC reanalysis.
5) Note: Different material than indicated on Sample Log / Description.
6) Note: Sample not submitted.
7) Note: Attached to asbestos containing material.
8) Note: Received wet.
9) Note: Possible surface contamination.
10) Note: Not building material. 1% threshold may not apply.
11) Note: Recommend TEM-NOB analysis as per EPA recommendations.
12) Note: Asbestos detected but not quantifiable.
13) Note: Multiple identical samples submitted, only one analyzed.
14) Note: Analyzed by EPA 600/R-93/116. Point Counting detection limit at 0.080%.
15) Note: Analyzed by EPA 600/R-93/116. Point Counting detection limit at 0.125%.
16) Note: This sample contains >10% vermiculite mineral. See Appendix for Recommendations for Vermiculite Analysis.
Recommendations for Vermiculite Analysis:
Several analytical protocols exist for the analysis of asbestos in vermiculite. These analytical approaches vary depending upon the nature of the vermiculite mineral being tested (e.g. un-processed gange, homogeneous exfoliated books of mica, or mixed mineral composites).Please contact your client representative for pricing and turnaround time options available.
iATL recommends initial testing using the EPA 600/R-93/116 method. This method is specifically designed for the analysis of asbestos in bulk building materials. It provides an acceptable starting point for primary screening of vermiculite for possible asbestos.
Results from this testing may be inconclusive. EPA suggests proceeding to a multi-tiered analysis involving wet separation techniques in conjunction with PLM and TEM gravimetric analysis (EPA 600/R-04/004).
For New York State customers, NYSDOH requires disclaimers and qualifiers for various vermiculite containing samples that direct analysis via ELAP198.6 and ELAP198.8 for samples that contain >10% vermiculite mineral where ELAP198.6 may be used to evaluate the asbestos content of the material. However, any test result using ELAP198.6 will be reported with the following disclaimer: “ELAP198.6 method does not remove vermiculite and may underestimate the level of asbestos present in a sample containing >10% vermiculite.”
Further information on this method and other vermiculite and asbestos issues can be found at the following: Agency for Toxic Substances and Disease Registry (ATSDR) www.atsdr.cdc.gov, United States Geological Survey (USGS) www.minerals.usgs.gov/minerals/, US EPA www.epa.gov/asbestos. The USEPA also has an informative brochure "Current Best Practices for Vermiculite Attic Insulation" EPA 747F03001 May 2003, that may assist the health and remediation professional.
The following is a summary of the analytical process outlines in the EPA 600/R-04/004 Method:
1)Analytical Step/Method: Initial Screening by PLM, EPA 600R-93/116 Requirements/Comments: Minimum of 0.1 g of sample. ~0.25% LOQ for most samples.
2)Analytical Step/Method:Wet Separation by PLM Gravimetric Technique, EPA R-04/004 Requirements/Comments: Minimum 50g** of dry sample. Analysis of "Sinks" only.
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC 14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
Page 12 of 13Dated : 1/22/2020 9:56:01
3)Analytical Step/Method:Wet Separation by PLM Gravimetric Technique, EPA R-04/004 Requirements/Comments: Minimum 50g** of dry sample. Analysis of "Floats" only.
4)Analytical Step/Method:Wet Separation by TEM Gravimetric Technique, EPA R-04/004 Requirements/Comments: Minimum 50g** of dry sample. Analysis of "Sinks" only.
5)Analytical Step/Method:Wet Separation by TEM Gravimetric Technique, EPA R-04/004 Requirements/Comments: Minimum 50g** of dry sample. Analysis of "Suspension" only.
LOQ, Limit of Quantitation estimates for mass and volume analyses.
*With advance notice and confirmation by the laboratory.
**Approximately 1 Liter of sample in double-bagged container (~9x6 inch bag of sample).
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Thunderbird Environmental, LLC 14 Leffingwell Rd Clinton CT 06413
1/20/2020Report Date:
Report No.: 607675 - PLM Project: NRCS - 25 3rd Ave Ext Project No.: 2019-099
Page 13 of 13Dated : 1/22/2020 9:56:01
CF00212 - CF00213
Tuesday, January 14, 2020
Sample ID#s:
Attn: Ms. Lauren Lomax Thunderbird Environmental 14 Leffingwell Rd Clinton, CT 06413
SDG ID: GCF00212
Project ID: NRCS 2 HBM SURVEGS
Sincerely yours, Laboratory Director Phyllis Shiller
If you are the client above and have any questions concerning this testing, please do not hesitate to contact Phoenix Client Services at ext.200. The contents of this report cannot be discussed with anyone other than the client listed above without their written consent.
NELAC - #NY11301
CT Lab Registration #PH-0618 MA Lab Registration #M-CT007 ME Lab Registration #CT-007 NH Lab Registration #213693-A,B
NJ Lab Registration #CT-003 NY Lab Registration #11301 PA Lab Registration #68-03530 RI Lab Registration #63 UT Lab Registration #CT00007 VT Lab Registration #VT11301
This laboratory is in compliance with the NELAC requirements of procedures used except where indicated.
This report contains results for the parameters tested, under the sampling conditions described on the Chain Of Custody, as received by the laboratory. This report is incomplete unless all pages indicated in the pagination at the bottom of the page are included.
A scanned version of the COC form accompanies the analytical report and is an exact duplicate of the original.
587 East Middle Turnpike, P.O. Box 370, Manchester, CT 06040 Telephone (860) 645-1102 Fax (860) 645-0823
Sample Id Cross Reference January 14, 2020
587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06045 Tel. (860) 645-1102 Fax (860) 645-0823
Environmental Laboratories, Inc.
SDG I.D.: GCF00212
Client Id Lab Id Matrix
Project ID: NRCS 2 HBM SURVEGS
25 THIRD AVE., EXT-BC CF00212 BULK
58 THIRD AVE., EXT-BC CF00213 BULK
Sample Information Custody Information Matrix:
Location Code:
Rush Request:
P.O.#:
Collected by:
Received by:
Analyzed by:
BULK
THUNDER
Standard 2019-099
01/08/20
LB
see "By" below
Laboratory Data
25 THIRD AVE., EXT-BC
Phoenix ID: CF00212
01/09/20 10:50 15:02
Parameter Result
RL/
PQL Units Date/Time By Reference
FOR: Attn: Ms. Lauren Lomax Thunderbird Environmental 14 Leffingwell Rd Clinton, CT 06413
Analysis Report January 14, 2020
Date Time
SDG ID: GCF00212
Client ID:
Project ID: NRCS 2 HBM SURVEGS
Dilution
587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06045 Tel. (860) 645-1102 Fax (860) 645-0823
Environmental Laboratories, Inc.
< 0.10TCLP Lead 0.10 01/11/20 TH SW846 1311/6010mg/L 1 CompletedTCLP Metals Digestion 01/10/20 Q/LS SW3010A CompletedTCLP Extraction for Metals 01/09/20 Q SW1311
Comments:
TCLP Non-Volatile Extraction:
Sample weight was < 100 grams (the minimum requirement of the method to insure homogeneity).
Phyllis Shiller, Laboratory Director January 14, 2020
If you are the client above and have any questions concerning this testing, please do not hesitate to contact Phoenix Client Services at ext.200.
The contents of this report cannot be discussed with anyone other than the client listed above without their written consent.
Reviewed and Released by: Rashmi Makol, Project Manager
RL/PQL=Reporting/Practical Quantitation Level ND=Not Detected BRL=Below Reporting Level
Ver 1
Sample Information Custody Information Matrix:
Location Code:
Rush Request:
P.O.#:
Collected by:
Received by:
Analyzed by:
BULK
THUNDER
Standard 2019-099
01/08/20
LB
see "By" below
Laboratory Data
58 THIRD AVE., EXT-BC
Phoenix ID: CF00213
01/09/20 13:10 15:02
Parameter Result
RL/
PQL Units Date/Time By Reference
FOR: Attn: Ms. Lauren Lomax Thunderbird Environmental 14 Leffingwell Rd Clinton, CT 06413
Analysis Report January 14, 2020
Date Time
SDG ID: GCF00212
Client ID:
Project ID: NRCS 2 HBM SURVEGS
Dilution
587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06045 Tel. (860) 645-1102 Fax (860) 645-0823
Environmental Laboratories, Inc.
< 0.10TCLP Lead 0.10 01/11/20 TH SW846 1311/6010mg/L 1 CompletedTCLP Metals Digestion 01/10/20 LS/LS SW3010A CompletedTCLP Extraction for Metals 01/09/20 Q SW1311
Comments:
TCLP Non-Volatile Extraction:
Sample weight was < 100 grams (the minimum requirement of the method to insure homogeneity).
Phyllis Shiller, Laboratory Director January 14, 2020
If you are the client above and have any questions concerning this testing, please do not hesitate to contact Phoenix Client Services at ext.200.
The contents of this report cannot be discussed with anyone other than the client listed above without their written consent.
Reviewed and Released by: Rashmi Makol, Project Manager
RL/PQL=Reporting/Practical Quantitation Level ND=Not Detected BRL=Below Reporting Level
Ver 1
QA/QC Data
Parameter Blk Blank RL
MS
MSD
MS
RPD
QA/QC Report January 14, 2020
587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06045 Tel. (860) 645-1102 Fax (860) 645-0823
Environmental Laboratories, Inc.
SDG I.D.: GCF00212
LCS
Dup
RPD
LCSD
LCS
RPD
Rec
Limits
RPD
Limits Sample Result
Dup Result
QA/QC Batch 513596 (mg/L), QC Sample No: CF00174 (CF00212)
ICP Metals - TCLP Extraction Lead NCBRL 87.75.70 87.7 0.0 75 - 125 2015.3 16.20.010
QA/QC Batch 513597 (mg/L), QC Sample No: CF00213 (CF00213)
ICP Metals - TCLP Extraction Lead 86.7BRL 86.7NC 82.6 4.8 75 - 125 20<0.10 <0.100.10
MS - Matrix Spike Phyllis Shiller, Laboratory Director
If there are any questions regarding this data, please call Phoenix Client Services at extension 200.
January 14, 2020 MS Dup - Matrix Spike Duplicate
RPD - Relative Percent Difference
LCS - Laboratory Control Sample
LCSD - Laboratory Control Sample Duplicate
NC - No Criteria
Intf - Interference
Sample Criteria Exceedances ReportTuesday, January 14, 2020
Acode Phoenix Analyte CriteriaResult RLSampNo Analysis
UnitsCriteria
GCF00212 - THUNDERCriteria: None
RL
Criteria
State: CT
#Error*** No Data to Display ***
Phoenix Laboratories does not assume responsibility for the data contained in this exceedance report. It is provided as an additional tool to identify requested criteria exceedences. All efforts are made to ensure the accuracy of the data (obtained from appropriate agencies). A lack of exceedence information does not necessarily suggest conformance to the criteria. It is ultimately the site professional's responsibility to determine appropriate compliance.
Phoenix Environmental Labs, Inc.
Rashmi Makol
Project Manager
Yes Were all samples received by the laboratory in a condition consistent with that described on the associated Chain-of-Custody document(s)?
For each analytical method referenced in this laboratory report package, were all specified QA/QC performance criteria followed, including the requirement to explain any criteria falling outside of acceptable guidelines, as specified in the CT DEP method-specific Reasonable Confidence Protocol documents?
No
Were all QA/QC performance criteria specified in the CTDEP Reasonable Confidence Protocol documents achieved?
For each analytical method referenced in this laboratory report package, were results reported for all constituents identified in the method-specific analyte lists presented in the Reasonable Confidence Protocol documents?
I, the undersigned, attest under the pains and penalties of perjury that, to the best of my knowledge and belief and based upon my personal inquiry of those responsible for providing the information contained in this analytical report, such information is accurate and complete.
Tuesday, January 14, 2020Date:
Notes: For all questions to which the response was "No" (with the exception of question #7), additional information must be provided in an attached narrative. If the answer to question #1, #1A or 1B is "No", the data package does not meet the requirements for "Reasonable Confidence".
This form may not be altered and all questions must be answered.
Authorized Signature:
Client: Thunderbird Environmental
Project Number:
Phoenix Environmental Labs, Inc.Laboratory Name:
Project Location:
REASONABLE CONFIDENCE PROTOCOL
NRCS 2 HBM SURVEGS
Yes No
Yes No
Yes No
Laboratory Sample ID(s): Sampling Date(s): 1/8/2020
Were samples received at an appropriate temperature (< 6 Degrees C)? 3 Yes No
Yes No
Are project-specific matrix spikes and laboratory duplicates included in the data set? 7 Yes No
Printed Name:
Position:
List RCP Methods Used (e.g., 8260, 8270, et cetera)
YesWere the method specified preservation and holding time requirements met? No 1A
Was the VPH or EPH method conducted without significant modifications (see section 11.3 of respective RCP methods)
1B Yes No
NA
a) Were reporting limits specified or referenced on the chain-of-custody?
b) Were these reporting limits met?
5 Yes No
NA
CTDEP RCP Laboratory Analysis QA/QC Certification Form - November 2007 Laboratory Quality Assurance and Quality Control Guidance Reasonable Confidence Protocols
LABORATORY ANALYSIS QA/QC CERTIFICATION FORM
CF00212, CF00213
1311/1312, 6010
VPH and EPH methods only:
Name of Laboratory
This certification form is to be used for RCP methods only.
RCP Certification Report January 14, 2020
587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06045 Tel. (860) 645-1102 Fax (860) 645-0823
Environmental Laboratories, Inc.
SDG I.D.: GCF00212
SDG Comments Metals Analysis:
The client requested a shorter list of elements than the 6010 RCP list. Only Lead is reported as requested on the chain of custody.
ICP Metals Narration Were all QA/QC performance criteria specified in the analytical method achieved? Yes.
Instrument:
CF00212, CF00213
BLUE 01/10/20 08:09 Tina Hall, Chemist 01/10/20
The initial calibration met criteria.
The continuing calibration standards met criteria for all the elements reported. The linear range is defined daily by the calibration range.
The continuing calibration blanks were less than the reporting level for the elements reported.
The ICSA and ICSAB were analyzed at the beginning and end of the run and were within criteria.The linear range is defined daily by the calibration range.
The following Initial Calibration Verification (ICV) compounds did not meet criteria: None.
The following Continuing Calibration Verification (CCV) compounds did not meet criteria: None.
The following ICP Interference Check (ICSAB) compounds did not meet criteria: None.
QC (Batch Specific):
CF00212
Batch 513596 (CF00174)
All LCS recoveries were within 75 - 125 with the following exceptions: None.
All LCSD recoveries were within 75 - 125 with the following exceptions: None.
All LCS/LCSD RPDs were less than 20% with the following exceptions: None.
QC (Site Specific):
CF00213
Batch 513597 (CF00213)
All LCS recoveries were within 75 - 125 with the following exceptions: None.
All LCSD recoveries were within 75 - 125 with the following exceptions: None.
All LCS/LCSD RPDs were less than 20% with the following exceptions: None.
All MS recoveries were within 75 - 125 with the following exceptions: None.
Temperature Narration The samples were received at 2.5C with cooling initiated.
(Note acceptance criteria for relevant matrices is above freezing up to 6°C)
ATTACHMENT B
SELECT PHOTOGRAPHS
Site Photographs 25 3rd Ave Ext. West Haven, Connecticut
Site Building
Newer Gas fired Furnace
| Cover Letter |
| Sample Id Cross Reference |
| Analytical Report |
| QA/QC Report |
| Sample Criteria Audit Report |
| RCP Checklist |
| Analysis Narratives |
| COC-GCF00212.pdf |
File details come from the government source that posted it. Updated .