Task Order #5 – Statement of Work
OVERVIEW
The Kisatchie National Forest, Catahoula Ranger District, has two work center out-buildings (seed cooler and chemical storage) that require renovations.
PROJECT LOCATION
The project is located at the Catahoula Ranger District Work Center in Grant Parish, Louisiana. The site is approximately three miles ESE of Bentley, Louisiana. Latitude 31.502906, longitude -92.460041.
Project location
Seed cooler location
Chemical shed location
PRICE RANGE
The Government estimated range is between $25,000 and $100,000. Payment bond required.
Existing Conditions
1. The seed cooler (SC) roof and structure are in varying stages of decay.
Figure 1. Front of tree seedling cooler
2. The seed cooler and supporting systems need some rehabilitation.
Figure 2. Back of tree seedling cooler
3. The chemical shed (CS) needs renovation and functional updates.
Figure 3. Front of chemical storage building
General
The project involves:
Demolition, building a metal shelter around the existing seed cooler, rehabilitating damaged/worn-out cooler components, painting, sealing, shelving construction, minor electrical wiring, and refrigeration work.
1. The contractor shall supply all material, labor, tools, equipment, cranes, vehicles, supplies, incidentals, supervision and safety measures to complete the project.
2. The contractor shall be responsible to verify the necessary quantities of materials to be supplied and square feet measurements of the buildings areas to be repaired.
3. Hours of work shall be anytime between the hours of 0630am to 0530pm Monday thru Friday.
Potable water, electrical power, water, and toilet facilities are available at the project site.
4. All work shall be done in accordance with manufacturer specifications, OSHA and this document.
Products
1. Government furnished property: None.
2. Contractor furnished products: All. Including but not limited to the following:
a. All required fasteners.
b. SC3: Replacement corner panels of seed cooler.
i. Manufacturer: Thermo-Kool
ii. POC: Brent Husband 1-800-647-1406; bhusband@thermokool.com mailto:bhusband@thermokool.com
iii. Installation IAW manufacturer’s specifications
iv. Cooler model #455922
v. Cooler Serial #6822
c. SC4: Replacement cooler door
i. Manufacturer: Thermo-Kool
ii. POC: Brent Husband 1-800-647-1406; bhusband@thermokool.com
iii. Installation IAW manufacturer’s specifications
iv. Cooler model #455922
v. Cooler Serial #6822
d. SC5: Elastomeric Joint seal and sealant. Installation and surface preparation IAW manufacturer’s specifications
e. SC6: Aluminum Diamond plate
i. 3/16” manufactured thickness
ii. 2.8 lbs/ square foot
f. SC7: Metal building cooler shelter. Table of estimated quantities is as follows:
QTY UNIT DESCRIPTION
380 LF 2x4 PURLIN
220 LF 4X4 11GA POST
600 SF 26 GA METAL ROOF
900 SF 26 GA METAL SIDING
48 LF 4" RECEIVING CHANNEL
98 LF FASCIA (EVE TRIM) 3"X4"
94 LF RAKE TRIM FOR GABLE ENDS ("L" TRIM)
40 LF OUTSIDE CORNERS
20 LF DOOR TRIM
1000 EA LONG LIFE SELF TAPPING METAL SCREWS
16 EA 3/4 ALL THREAD EPOXY ANCHORS
g. SC8: Refrigeration Condenser replacement. Estimated quantities and specifications are as follows:
QTY UNIT DESCRIPTION
1 EA
HEAT CRAFT CONDENSER, 21,500 BTU, 3HP SINGLE
PHASE, REFRIGERANT 404/R22 CURRENT MODEL
AVAILABLE: LHTO30X6BFMT.
1 EA INCIDENTAL MATERIALS (INSULATION, COPPER ETC)
h. SC9: Cooler Thermometer replacement
i. Manufacturer: Thermo-Kool
ii. POC: Brent Husband 1-800-647-1406; bhusband@thermokool.com
iii. Installation IAW manufacturer’s specifications
iv. Cooler model #455922
v. Cooler Serial #6822
i. SC10: Cooler Lights
i. LED
ii. IPV6 Code rated
iii. Vapor tight fixture housing
iv. High impact diffuser.
v. Exterior rated switch boxes
vi. PVC conduit
j. SC12: Cooler and building grounds
i. 5/8” x 8’ ground rods
ii. 4 AWG bare ground wire
iii. Misc. lugs, buses, fasteners, etc. as required
k. CS2: Heavy duty metal shelving. Table of estimated quantities as follows:
l. CS3:
Skylites, Polycarbonate profile to match existing.
m. CS4: Thermostatic control
i. NEMA 4x rated
ii. Electromechanical
iii. Rugged thermoplastic splashproof enclosure
iv. O-ring sealed set point adjustment knob
n. CS5: LED lights with impact rated diffuser covers
o. CS6: Elastomeric Joint seal and PAINT. Installation and surface preparation IAW manufacturer’s specifications
p. CS7: Elastomeric Joint seal and sealant. Installation and surface preparation IAW manufacturer’s specifications
q. CS8: Type 1 Chemical resistant Epoxy smooth floor coating
i. 25 mil minimum thickness installation
r. CS9: HAZMAT placards are to be MUTCD compliant
Execution: Contractor coordination
1. The Contractor shall schedule a pre-construction meeting a minimum of two weeks prior to starting their operations.
2. The Contractor shall provide shop drawings and tentative schedule of operations for review by the Contracting Officer during the pre-construction meeting.
3. The Contractor shall coordinate with the Government to minimize interruptions of Forest Service operations.
4. The Contractor shall cordon off an area of 20’ around the building to protect government traffic from tire laceration hazards.
QTY UNIT DESCRIPTION
400 LF 1.5"X3.5" 11GA TUBE
280 SF 3/16" ALUMINUM DIAMOND PLATE
250 EA SELF TAPPING METAL SCREWS (COUNTER SINK)
8 EA ALLTHREAD AND EPOXY FLOOR FASTENERS
5. The Contractor shall coordinate with the Government to have any vehicles moved which may hinder contractor operations.
6. The contractor shall police for tire laceration hazards with a magnet daily.
7. The contractor will remove all debris, rags, waste material; tools etc. from the project site at the end of each workday and properly dispose of offsite.
Execution
1. Contractor shall provide product submittals complete with manufacturer’s specifications for installation on the existing buildings to Contracting Officer for approval.
2. Contractor shall execute coordination requirements above.
3. Contractor shall maximize manufacturer’s pre-cut and pre-finish capabilities by providing shop drawings to Contracting Officer and manufacturer.
4. Contractor shall be mindful of associated weather risks and schedule staff, material delivery and equipment to minimize risk of weather damage.
5. Contractor shall perform all electrical work under the supervision of a licensed electrician and In Accordance With (IAW) National Electric Code.
6. Contractor shall perform all refrigeration work IAW EPA section 608.
7. Contractor shall perform all welding operations IAW OSHA and consistent with standard industry practice.
Additional photos (exterior and interior) are attached.
Project Photographs
Photo 1. Front of tree seedling cooler
Photo 2. Side of tree seedling cooler
Photo 3. Back of tree seedling cooler
Photo 4. Breaker box for tree seedling cooler
Photo 5. Breaker box and outside unit for tree seedling cooler
Photo 6. Outside cooling unit for tree seedling cooler
Photo 7. Fans inside tree seedling cooler
Photo 8. Manufacturing information for tree seedling cooler.
Photo 9. Tree cooler thermostat
Photo 10. Inside tree seedling cooler
Photo 11. Inside tree seedling cooler
Photo 12. Tree cooler door
Photo 13. Front of chemical storage building
Photo 14. Side of chemical storage building with MSDS box and post
Photo 15. Back of chemical storage building
Photo 16. Other side of chemical storage building
Photo 17. Electrical box inside chemical storage building
Photo 18. Electrical box with exhaust fan
Photo 19. Light inside chemical storage building
Photo 20. Light inside chemical storage building
Photo 21. Light and exhaust fan timer and switch
Photo 22. Skylights inside chemical storage
Photo 23. Inside the chemical storage building
SEED COOLER (SC) and CHEMICAL SHED (CS) RENOVATION
SCHEDULE OF ITEMS AND BID SHEET
ITEM QTY UNIT DESCRIPTION UNIT COST EXTENDED
COST
SC1 1 LS MOBILIZATION (SC and CS)
SC2 1 LS DEMOLITION AND REMOVAL OF EXISTING
COOLER SHELTER
SC3 2 EA REPLACE DAMAGED CORRODED CORNER
PANELS: FRONT LEFT CORNER & BACK RIGHT
SC4 1 EA REPLACEMENT COOLER DOOR INSTALLED.
SC5 735 SF
EXTERIOR WALL COATING: SURFACE PREP,
ELASTOMERIC JOINT SEALS, ELASTOMERIC
SEALANT
SC6 432 SF
3/16" ALUMINUM DIAMOND PLATE FLOORING.
CONTINUOUS WELDED ALL JOINTS. FLOATING
FLOOR.
SC7 1 LS METAL BUILDING COOLER SHELTER:
SC8 1 LS REFRIGERATION CONDENSER REPLACEMENT
SC9 1 EA COOLER THERMOMETER REPLACEMENT
SC10 4 EA
LED COOLER LIGHTS WITH IP67 CODE RATING.
VAPOR TIGHT FIXTURE HOUSING, HIGH
IMPACT DIFFUSER. ALL WIRING TO BE HOUSED
IN PVC CONDUIT. SWITCH AND JUNCTION
BOXES EXTERIOR GRADE
SC11 1 LS RE-INSTALL EXISTING SUB-PANEL TO OUTSIDE
OF NEW COOLER SHELTER
SC12 4 EA
PROVIDE COOLER SHELL AND METAL
BUILDING POTENTIAL TO GROUND IAW NEC
AND LOCAL CODE.
CS1 1 LS DEMOLITION AND REMOVAL OF WOOD
SHELVING
CS2 1 LS HEAVY DUTY METAL SHELVING. FASTEN TO
FLOOR.
CS3 2 EA REPLACE POLYCARBONATE SKYLITES WITH
MATCHING PROFILE LITES.
CS4 1 EA WIRING: 1. REWIRE EXHAUST FAN WITH
THERMOSTATIC CONTROL.
CS5 4 EA
INSTALL LED LIGHTS CONDUIT AND CIRCUIT.
MOUNT VERTICALLY ON SHELVING. IMPACT
RATED COVERS
CS6 560 SF
EXTERIOR WALL COATING: SURFACE PREP,
ELASTOMERIC JOINT SEALS, ELASTOMERIC
PAINT
CS7 256 SF ELASTOMERIC ROOF SEALANT
CS8 192 SF NON-SLIP EPOXY FLOOR PAINT
CS9 1 LS
SIGNAGE: INSTALL HAZMAT PLACARDS ON
DOOR AND ALL SIDES OF BUILDING. REMOVE
MSDS BOX AND POST. INSTALL MSDS BOX ON
INSIDE OF DOOR.
TOTAL