This document appears to be a set of construction drawings and specifications for an aluminum box culvert installation project. The key details are:

The project involves repairs and drainage improvements to National Forest Service Roads (NFSR) 104 ("Mingus Mountain Road") and 374 ("Granite Basin Road") in the Prescott National Forest. The work includes adding culverts, reconditioning ditches, replacing paved road edges, and installing erosion protection measures along NFSR 104. On NFSR 374, the work includes slurry seal and restriping of the Playa Day Use area, full-depth asphalt reclamation and repaving at the Wekuvde Picnic Site, and repairs to the main road. A new fee lane will also be constructed near the Cayuse Equestrian recreation site. Optional work includes repairing two concrete drainage crossings.

The project is a small business set-aside with a magnitude between $1-5 million. A mandatory site visit is scheduled for August 14, 2024, and offers are due September 12, 2024 by 1:00 pm PT. The contract will be awarded on a Lowest Price Technically Acceptable basis. The work will be performed under a Firm Fixed-Price construction contract by the U.S. Forest Service Region 3 - Southwestern Region.

View the file

Other files

File Type Posted
B08 127EAX23Q0045 Granite Basin and Mingus Mnt. Road NFSR 374 and 104 Notice of Award - Earth Resources Corp. revised.pdf PDF
A1_AttachmentB_NFSR374_ConstructionDrawings_240822e.pdf PDF
A1_AttachmentB_NFSR374_ConstructionDrawings_240822d.pdf PDF
A1_AttachmentB_NFSR374_ConstructionDrawings_240822c.pdf PDF
A1 AttachmentD_PrescottFirePlan.pdf PDF
A1_AttachmentA_NFSR104_ConstructionDrawings_240821b.pdf PDF
A1_AttachmentB_NFSR374_ConstructionDrawings_240822b.pdf PDF
A1_AttachmentA_NFSR104_ConstructionDrawings_240821c.pdf PDF
A1_AttachmentB_NFSR374_ConstructionDrawings_240822a.pdf PDF
A1_AttachmentA_NFSR104_ConstructionDrawings_240821d.pdf PDF
A1_AttachmentA_NFSR104_ConstructionDrawings_240821a.pdf PDF
A1 2024.08.22_ScheduleOfItems.xlsx XLSX spreadsheet
A1 2024.08.14_SignInSheet.pdf PDF
A1 AttachmentC_SpecificationPackage.pdf PDF
A1 2024.08.22_StatementOfWork.pdf PDF
A1 127EAX24Q0045 - Amendment I.pdf PDF
127EAX24Q0045 - Granite Basin and Mingus Mountain Road NFSR 374 and 104 - Solicitation.pdf PDF
Statement of Work rev 07.16.2024.pdf PDF
Statement of Work Attachment A2.pdf PDF
Statement of Work Attachment B.pdf PDF
Statement of Work Attachment D.pdf PDF
2024.07.01_ScheduleOfItems.xlsx XLSX spreadsheet
Statement of Work Attachment C.pdf PDF
General Decision Number AZ02240008 1.19.2024.docx DOCX document
BioPreferred.pdf PDF
Statement of Work Attachment A1.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDITIONAL SELECT GRANULAR STRUCTURAL BACKFILL NOTES:

SATISFACTORY BACKFILL MATERIAL, PROPER PLACEMENT, AND COMPACTION ARE KEY

FACTORS IN OBTAINING MAXIMUM STRENGTH AND STABILITY.

THE BACKFILL MATERIAL SHOULD BE FREE OF ROCKS, FROZEN LUMPS, AND FOREIGN

MATERIAL THAT COULD CAUSE HARD SPOTS OR DECOMPOSE TO CREATE VOIDS. BACKFILL

MATERIAL SHOULD BE WELL GRADED GRANULAR MATERIAL THAT MEETS THE REQUIREMENTS

OF AASHTO M-145 FOR SOIL CLASSIFICATIONS A-1, A-2-4, A-2-5, OR A-3 MODIFIED.

SEE THE STRUCTURAL PLATE BACKFILL GROUP CLASSIFICATION TABLE ON THIS SHEET.

BACKFILL MUST BE PLACED SYMMETRICALLY ON EACH SIDE OF THE STRUCTURE IN 8" LOOSE

LIFTS. EACH LIFT IS TO BE COMPACTED TO A MINIMUM OF 90% DENSITY PER AASHTO T-180.

A HIGH PERCENTAGE OF SILT OR FINE SAND IN THE NATIVE SOILS SUGGESTS THE NEED FOR A

WELL GRADED GRANULAR BACKFILL MATERIAL TO PREVENT SOIL MIGRATION. IF THE

PROPOSED BACKFILL IS NOT A WELL-GRADED MATERIAL, A NON-WOVEN GEOTEXTILE FILTER

FABRIC SHALL BE PLACED BETWEEN THE SELECT BACKFILL AND THE IN SITU MATERIAL.

DURING BACKFILL, ONLY LIGHTWEIGHT TRACKED VEHICLES (D-4 OR LIGHTER) SHOULD BE NEAR

THE STRUCTURE AS FILL PROGRESSES ABOVE THE CROWN AND TO THE FINISHED GRADE.

THE ENGINEER AND CONTRACTOR ARE CAUTIONED THAT THE MINIMUM COVER MAY NEED TO

BE INCREASED TO HANDLE TEMPORARY CONSTRUCTION VEHICLE LOADS

(HEAVIER THAN D-4).

SELECT GRANULAR STRUCTURAL BACKFILL LIMITS.

INITIAL LIFTS OVER THE CROWN OF STRUCTURE AS

INDICATED BY SHADED AREA TO BE COMPACTED TO

REQUIRED DENSITY WITH HAND OPERATED EQUIPMENT

OR WITH LIGHTWEIGHT(D-4 OR LIGHTER) EQUIPMENT.

NOTES:

1. ALL SELECT GRANULAR BACKFILL TO BE PLACED IN A BALANCED

FASHION IN THIN LIFTS (8" LOOSE TYPICALLY) AND COMPACTED TO

90 PERCENT DENSITY PER AASHTO T-180.

2. COMPLETE AND REGULAR MONITORING OF THE ALUMINUM BOX CULVERT

SHAPE IS NECESSARY DURING ALL BACKFILLING OF THE STRUCTURE.

3. PREVENT DISTORTION OF SHAPE AS NECESSARY BY VARYING COMPACTION

METHODS AND EQUIPMENT.

4. TRENCH WIDTH OTHER THAN 3 FEET SHALL BE BY DIRECTION OF THE

ENGINEER OF RECORD.

5. SWITCH TO PLACING SELECT GRANULAR BACKFILL NEAR IN RADIAL

LIFTS THE MIDDLE OF THE HAUNCH CURVE.

GROUP CLASSIFICATION A-1-a A-1-b A-2-4 A-2-5 A-3 Sieve Analysis Percent Passing

No. 10 (2.000 mm) 50 max. ---- ---- ---- ----

No. 40 (0.425 mm) 30 max. 50 max. ---- ---- 51 max.* No. 200 (0.075 mm) 15 max. 25 max. 35 max. 35 max. 10 max.

Atterberg Limits for Fraction Passing No. 40 (0.425 mm)

Liquid Limits ---- ---- 40 max. 41 min. ----

Plasticity Index 6 max. 6 max. 10 max. 10 max. Non Plastic

Usual Materials Stone Fragment, Gravel and Sand

Silty or Clayey Gravel and Sand

Coarse Sand

*Modified from M-145.

Fine beach sands, windblown sands, stream deposited sands, etc., exhibiting fine, rounded particles and typically Classified by AASHTO M-145 as A-3 materials should not be used.

Reference the most current version of ASTM D2487, Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System), for comparable soil groups.

STRUCTURAL PLATE BACKFILL GROUP CLASSIFICATION, REFERENCE AASHTO M-145

1.0 STANDARDS AND DEFINITIONS

1.1 STANDARDS - All standards refer to the current ASTM/AASHTO edition unless otherwise noted.

1.1.1 ASTM B-864 "Standard Specification for Corrugated Aluminum Box Culverts" (AASHTO Designation M-219).

1.1.2 AASHTO Standard Specification for Highway Bridges - Section 12 Division I - Design, AASHTO LRFD Bridge Design Specifications Section 12.

1.1.3 AASHTO Standard Specification for Highway Bridges - Section 26 Division II - Construction, AASHTO LRFD Bridge Construction Specifications - Section 26. ASTM B789, Standard Practice for Installing Corrugated Aluminum Structural Plate Pipe.

1.2 DEFINITIONS

1.2.1 Owner - In these specifications the word "Owner" shall mean

1.2.2 Engineer - In these specifications the word "Engineer" shall mean the Engineer of Record or Owner's designated engineering representative.

1.2.3 Manufacturer - In these specifications the word "Manufacturer" shall mean CONTECH ENGINEERED SOLUTIONS 800-338-1122

1.2.4 Contractor - In these specifications the word "Contractor" shall mean the firm or corporation undertaking the execution of any installation work under the terms of these specifications.

1.2.5 Approved - In these specifications the word "approved" shall refer to the approval of the Engineer or his designated representative.

1.2.6 As Directed - In these specifications the words "as directed" shall refer to the directions to the Contractor from the Owner or his designated representative.

2.0 GENERAL CONDITIONS

2.1 Any installation guidance provided herein shall be endorsed by the engineer; discrepancies herein are governed by the Engineer's plans and specifications.

2.2 The Contractor shall furnish all labor, material and equipment and perform all work and services except those set out and furnished by the Owner, necessary to complete in a satisfactory manner the site preparation, excavation, filling, compaction, grading as shown on the plans and as described therein. This work shall consist of all mobilization clearing and grading, grubbing, stripping, removal of existing material unless otherwise stated, preparation of the land to be filled, filling of the land, spreading and compaction of the fill, and all subsidiary work necessary to complete the grading of the cut and fill areas to conform with the lines, grades, slopes, and specifications. This work is to be accomplished under the observation of the Owner or his designated representative.

2.3 Prior to bidding the work, the Contractor shall examine, investigate and inspect the construction site as to the nature and location of the work, and the general and local conditions at the construction site, including without limitation, the character of surface or subsurface conditions and obstacles to be encountered on and around the construction site and shall make such additional investigation as he may deem necessary for the planning and proper execution of the work.

If conditions other than those indicated are discovered by the Contractor, the Owner shall be notified immediately. The material which the Contractor believes to be a changed condition shall not be disturbed so that the owner can investigate the condition.

2.4 The construction shall be performed under the direction of the Engineer.

2.5 All aspects of the structure design and site layout including foundations, backfill, end treatments and necessary scour consideration shall be performed by the Engineer.

LI

M

IT

S

O F

C O

M

PA

C

TE

D

AC

C

EP

TA

BL

E R

O A

D F

IL

L

SPAN

R

IS

E

M

IN

. C O

VE

R

TRENCH CONDITION MIN. 3 FEET EMBANKMENT

CONDITIONMIN. 3 FEET

MINIMUM LIMITS OF COMPACTED SELECT

GRANULAR STRUCTURAL BACKFILL

8"

LOOSE LIFTS

SECTION

CL

NATURAL

UNDISTURBED

EMBANKMENT

3.0 ASSEMBLY AND INSTALLATION

3.1 Bolts and nuts shall conform to the requirements of ASTM A-307 and/or ASTM A-449. The box culvert shall be assembled in accordance with the plate layout drawings provided by the manufacturer and per the manufacturer's recommendations.

Bolts shall be tightened using an applied torque of between 100 and 150 ft.-lbs.

3.2 The box culvert shall be installed in accordance with the plans and specifications, the manufacturer's recommendations, and AASHTO Standard Specification for Highway Bridges - Section 26 Division II - Construction/AASHTO LRFD Bridge Construction Specifications - Section 26.

3.3 Trench excavation shall be made in embankment material that is structurally adequate. The trench width shall be shown on the plans. Poor quality in situ embankment material must be removed and replaced with suitable backfill as directed by the Engineer.

3.4 Aluminum Box Culvert designs require a minimum allowable

soil-bearing pressure of 4,000 psf. Lower bearing capacities may be accommodated with a site specific design for an aluminum foundation or a concrete footing.

If the engineer determines the natural foundation is inadequate to support the structure's backfill, the poor material shall be excavated, removed and replaced to a suitable depth with competent material. The specific depth of excavation required may be reduced by utilizing a geosynthetic reinforced foundation as designed by a qualified geotechnical engineer. For additional information contact your local Contech representative.

3.5 When a metal foundation is used, the soil bedding requires a minimum of 6 inches of loose granular material with a maximum particle size of one half the corrugation depth. The proper width of the bedding material required shall conform to the project plans and specifications.

Bedding preparation is critical to both structure performance and service life. The bedding should be constructed to uniform line and grade to avoid distortions that may create undesirable stresses in the structure and/or rapid deterioration of the roadway. The bed should be free of rock formations, protruding stones, frozen lumps, roots, and other foreign matter that may cause unequal settlement.

3.6 The structure shall be assembled in accordance with the

Manufacturer's instructions. All plates shall be unloaded and handled with reasonable care. Plates shall not be rolled or dragged over gravel rock and shall be prevented from striking rock or other hard objects during placement in trench or on bedding.

When installed on a full invert or on flexible footing pads, assembly of the invert or footing pads shall start at the downstream end.

Circumferential seam laps shall shingle over the top of the downstream plates as assembly progresses upstream. Whether the box culvert is installed on a concrete footing, full metal invert, or flexible footing pad, assembly of the structure shell shall start at the upstream end. Downstream rings of plates shall be assembled outside of the upstream rings (Circumferential seams are shingled downstream when viewed from the inside of the shell).

3.7 The structure shall be backfilled using clean well graded granular material that meets the requirements for soil classifications A-1, A-2-4, A-2-5, or A-3 modified per AASHTO M-145. See the structural plate backfill group classification table on this sheet.

Backfill must be placed symmetrically on each side of the structure in 8 inch loose lifts. Each lift shall be compacted to a minimum of 90 percent density per AASHTO T-180.

3.8 Standard highway loads that meet the permissible design load limits for an Aluminum Box Culvert are not allowed on the structure until it is backfilled completely and pavement is in place.

The addition of temporary soil for heavy construction loads is not feasible or permissible for Aluminum Box Culverts. By design, these structures are limited in the range of permissible fill heights and live loads.

Heavy construction loads that exceed that of the particular highway live load design limits are not allowed on Aluminum Box Culverts without approval from the Engineer.

3.9 If an aluminum headwall and/or wingwall system is specified, the select granular structural backfill limits shall extend past the deadman anchor system. Contact the Engineer if stiff material or rock is encountered where the wingwalls and deadmen are to be installed.

STRUCTURAL PLATE

DRAWING

DYOB800-338-1122 513-645-7000 513-645-7993 FAX

9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069

The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.

If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.

www.ContechES.com

ALBC

SPECIFICATIONS

CHECKED:

DRAWN:DESIGNED:

APPROVED:

SHEET NO.:

OF

DATE:PROJECT No.:

D10

DYO DYO

DYO DYO

MARK DATE REVISION DESCRIPTION BY D8

Jeremy.Johnson Rectangle

Jeremy.Johnson Text Box

ROADFILL ABOVE

MIN. COVER LEVEL

Justin Helton Stamp

Justin Helton Stamp

Justin Helton Stamp

STRUCTURAL PLATE

DRAWING

DYOB800-338-1122 513-645-7000 513-645-7993 FAX

9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069

The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.

If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.

www.ContechES.com CHECKED:

DRAWN:DESIGNED:

APPROVED:

SHEET NO.:

OF

DATE:PROJECT No.:

D10

DYO DYO

DYO DYO

SAMPLE PARTIAL FOUNDATION PLAN

(NOT PROJECT SPECIFIC)

SA

M

PL

E

D R

AW

IN

G O

N

LY

EXPRESS FOUNDATIONS

C STRUCTUREL

A

KE

Y

W

AY

2" JOINT

6"

ADETAIL 1

SECTION

R

IS

E

SPAN

FOUNDATION WIDTH

DETAIL 1

FO

U

N D

AT

IO

N D

EP

TH

3" C

LR

(NOT PROJECT SPECIFIC)

(NOT PROJECT SPECIFIC)

1'-0" (TYP)

4" K

EY

W

AY

MARK DATE REVISION DESCRIPTION BY

ALBC

EXPRESS FOUNDATION SAMPLES

D9

QUIKRETE

Stamp

QUIKRETE

Stamp

QUIKRETE

Stamp

STRUCTURAL PLATE

DRAWING

DYOB800-338-1122 513-645-7000 513-645-7993 FAX

9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069

The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.

If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.

www.ContechES.com CHECKED:

DRAWN:DESIGNED:

APPROVED:

SHEET NO.:

OF

DATE:PROJECT No.:

D10

DYO DYO

DYO DYO

C

B

N.T.S.

ARMORFLEX PARTIAL INVERT

PARTIAL LAYOUT PLAN

A

A

FLOW

2 UNIT

MIN.

N.T.S.

STANDARD TERMINATION C

N.T.S.

ARMORFLEX WINGWALL

TERMINATION B

N.T.S.

ARMORFLEX STRUCTURE TERMINATION A

N.T.S.

ARMORFLEX FULL INVERT

PARTIAL LAYOUT PLAN

C

B

A

A

E

N.T.S.

A-JACKS PARTIAL INVERT

PARTIAL LAYOUT PLAN

D

FLOW

N.T.S.

A-JACKS STRUCTURE

TERMINATION D

N.T.S.

A-JACKS WINGWALL

TERMINATION E

FLOW

C

6" M

IN

6" M

IN

O

PT

IO

N

A O

PT

IO

N B

O

PT

IO

N

C

N.T.S.

A-JACKS PARTIAL INVERT

SA

M

PL

E

D R

AW

IN

G O

N

LY

MARK DATE REVISION DESCRIPTION BY

ALBC

ARMORTEC SAMPLES

D10

File details come from the government source that posted it. Updated .