Exhibit A_Mondeaux Floor Plans_12445526Q0121.pdf

PDF 858 KB Posted

Attached to
Mondeaux Floor Refinishing
Solicitation number
12445526Q0121
Issued by

About this file

These are architectural construction drawings and floor plans for the renovation and restoration of historic buildings, including existing quarters and a proposed lodge facility. The documents show detailed layouts for residential quarters with bedrooms, living areas, kitchen, bathroom, and laundry facilities, as well as a larger lodge structure with dining areas, kitchen, service areas, mechanical rooms, and shower facilities. The drawings include room finish schedules specifying materials and finishes for floors, walls, and ceilings across multiple spaces, with notations for historic preservation requirements and ABA accessibility compliance throughout.

Key construction specifications include provisions for new flooring materials such as luxury vinyl tile and polyurethane finishes, retention and restoration of historic doors and windows, new plumbing and electrical systems, refinished hardwood flooring with 25% salvaged and 75% new material replacement, removal of non-historic elements, and installation of new thresholds meeting ABA standards. Hardware specifications call for Grade 1 heavy-duty fixtures in US10B dark satin bronze oil-rubbed finish, with all exterior doors keyed alike. The drawings reference multiple specification sheets and detail pages for mechanical, electrical, and plumbing systems, indicating this is part of a comprehensive renovation project focused on historic preservation while meeting modern accessibility and building code requirements.

View the file

Other files

File Type Posted
Amd_0001-Sol_12445526Q0121.pdf PDF
Att 02_Statement Of Work_260825.pdf PDF
Moneaux Floor Pictures_260819.docx DOCX document
Q and A_12445526Q0121.xlsx XLSX spreadsheet
HOW TO FOLLOW PROJECTS ON SAM FOR EMAIL ALERTS.pdf PDF
Pictures_12445526Q0121.pdf PDF
Att 01_Schedule of Items_260805.docx DOCX document
Att 02_STATEMENT OF WORK_260623.pdf PDF
Sol_12445526Q0121.pdf PDF
Att 03_Wage Rates_260518.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Refrigerator

R ange

C4 Q-A301

LINEN

COVERED

PORCH

1 1

HALL LAUNDRY CLO. CLO.

CLO.

WEST

BEDROOM

EAST

BEDROOM

LIVING/

DINING

ROOM

KITCHEN

BATHROOM

EXISTING

CRAWLSPACE

ACCESS

EXISTING

ATTIC

ACCESS

TYP.

REMOVE NON-HISTORIC WINDOW AS INDICATED.

RETAIN AND RESTORE HISTORIC EXTERIOR DOOR.

REMOVE EXTERIOR PERIMETER FOUNDATION INSULATION, TYP.

QUARTERS PLANS KEY NOTES

PROVIDE NEW, HISTORICALLY COMPLIANT SCREEN DOOR AS

INDICATED.

REMOVE PORCH DECK ASSEMBLY. RETAIN ALL

ORIGINAL MATERIAL ABOVE FINISHED DECK HEIGHT.

2PROVIDE NEW, HISTORICALLY COMPLIANT, COMBINED

INSULATED WINDOW/ SCREEN UNIT AS INDICATED.

SEE A1/ Q-A201.

REMOVE NON-HISTORIC SCREEN DOOR AS INDICATED.

REBUILD PORCH DECK ASSEMBLY PER SHEET S101.

PREPARE AND REPAINT WALLS AND CEILING THROUGHOUT BUILDING PER SCHEDULE. 9

10REFINISH EXISTING FLOORING THROUGHOUT BUILDING UNO.

11REMOVE EXISTING NON-HISTORIC PLUMBING FIXTURES AS INDICATED.

12PROVIDE NEW PLUMBING FIXTURES PER PLUMBING SHEETS.

REMOVE EXISTING DOOR, SCREEN DOOR, AND

(2) WOODEN STEPS AS INDICATED.

14PROVIDE NEW, HISTORICALLY COMPLIANT 3'-0 x 6'-8" DOOR AND HISTORICALLY COMPLIANT 3'-0 x 6'-8" SCREEN DOOR.

15REMOVE EXISTING KITCHEN FLOORING AND REPLACE WITH

NEW RESILIENT FLOORING AS SELECTED BY OWNER.

16REMOVE EXISTING KITCHEN CABINETS AND COUNTERTOP.

PROVIDE NEW KITCHEN CABINETS AND COUNTERTOP. SEE A4/Q-A301.

17PROVIDE NEW KITCHEN RANGE AND REFRIGERATOR SELECTED

BY OWNER.

A4 Q-A301

COVERED

PORCH

2 2

NEW

CS ACCESS

3'-6" x 3'-2"

LINEN HALL LAUNDRY CLO. CLO.

CLO.

WEST

BEDROOM

EAST

BEDROOM

LIVING/

DINING

ROOM

KITCHEN

BATHROOM

FIELD LOCATE DOWNSPOUT

LOCATIONS. LOCATE AS

UNOBTRUSIVELY AS POSSIBLE.

DS

DS

DS

151617

REMOVE ASPHALT

IN FRONT OF

COVERED PORCH

(APPROXIMATE AREA)

1' - 6"

5' - 0"

5' - 0"

LEVEL LANDING

PROVIDES ABA

MANEUVERING

SPACE

NEW SIDEWALK

Q-A101 3C

PNTEPOXY PAINT (SEMI-GLOSS FINISH)

CPUCEMENTITIOUS POLYURETHANE

POLYPOLYURETHANE WOOD FINISH

EX.EXISTING

WDWOOD

VB VINYL BASE

LVTLUXURY VINYL TILE

KEY

PRE-MANUFACTURED

ABA-COMPLIANT

DOOR THRESHOLD

1/2" MAXIMUM HEIGHT

WITH 1:2 BEVEL

1/2" EXPANSION JOINT,

TYP. @ EXT. SLAB

NEW FINISH FLOORING

EXISTING SUBFLOOR

NEW LANDING &

SIDEWALK PER

CIVIL SHEETS

MAX. 1/4" VERTICAL

REPLACE EXISTING

SHEATHING @ LANDING

w/ 1/2" PT PLYWOOD &

PAINT-ON WATERPROOFING

EXTEND 6" BELOW MUDSILL

ENGINEERING

ARCHITECTURE

PLANNING

SURVEYING

ENVIRONMENTAL

PROJECT TITLE:

OWNER:

PROJECT LOCATION:

PROJECT NO:

DRAWN BY:

CHECKED:

APPROVED:

12345

12345

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

DESIGNED BY:

DATE: ISSUED FOR:

100 PORTAGE STREET

HOUGHTON, MI 49931

(906) 482-4810

424 SOUTH PINE STREET

ISHPEMING, MI 49849

(906) 485-1011

707 ASHMUN ST.

SAULT STE. MARIE, MI 49783

(906) 635-0511

1701 DUNLAP AVE. SUITE B

MARINETTE, WI 54143

(715) 732-4188

2906 N. STEPHENSON AVE. SUITE 2

IRON MOUNTAIN, MI 49801

(906) 779-0937

P:\U 28-17435 U

SD

A FS-U

SFS C

N

N F M ondo - Boulder 17\D w gs\M ondeaux_base_D

W G

\U 28-17435_U

SFS-M

ondeaux_Q uarters_Base.rvt

5/21/2019 11:49:29 AM

Q-A101

QUARTERS FLOOR

PLANS

MONDEAUX

RECREATION SITE

RESTORATION AND

REHABILITATION

USDA FOREST

SERVICE

W7969 PARK RD,

WESTBORO, WI

54490

U28-17435

JDMA

KRC

TP

JDMA

Issue Date Project Status

1/4" = 1'-0" 1AEXISTING QUARTERS FLOOR PLAN

MEASURED DWGS10-30-17

CHECK SET11-17-17

35% REVIEW11-22-2017

35% B12-15-17 35% C2-27-18

65% REVIEW12-7-2018

95% REVIEW4-19-2019

REVISED 95% REVIEW5-9-2019

FINAL5-17-2019

1/4" = 1'-0" 4APROPOSED QUARTERS FLOOR PLAN

ROOM FINISH SCHEDULE

ROOM NAME

FLOORWALLSCEILING

REMARKS MATERIALFINISHBASENORTHSOUTHEASTWESTMATERIALFINISH

NE BEDROOMWDPOLYEX.PNTPNTPNTPNTEX.PNT

NW BEDROOMWDPOLYEX.PNTPNTPNTPNTEX.PNT

LIVING/ DINING ROOMWDPOLYEX.PNTPNTPNTPNTEX.PNT

KITCHENLVT-VBPNTPNTPNTPNTEX.PNT

BATHROOMLVT-VBPNTPNTPNTPNTEX.PNT

NW CLOSETWDPOLYEX.PNTPNTPNTPNTEX.PNT

LINENSWDPOLYEX.PNTPNTPNTPNTEX.PNT

HALLWAYWDPOLYEX.PNTPNTPNTPNTEX.PNT

LAUNDRYLVT-VBPNTPNTPNTPNTEX.PNT

NE CLOSETWDPOLYEX.PNTPNTPNTPNTEX.PNT

1 1/2" = 1'-0" 3ABA THRESHOLD

mbeuning Rectangle mbeuning Rectangle mbeuning Rectangle

FREEZER

PREP

TABLE

FRIDGE DW

POP ICEPOP

FRIDGE

FREEZER

D4 L-A302

A4 L-A302

A1 L-A302

MECHANICAL

KITCHEN

SERVICE AREA

6' - 0"

SMALL DINING

ROOM LOBBY

WOMEN

MEN

N. SHOWER

S. SHOWER

LARGE DINING

ROOM

NEW 2X6

PARTITION WALL

3'-0" X 6'-8" CASED

OPENING, CENTER IN WALL

INFILL EXISTING OPENING WITH NEW

FRAMING, FINISH TO MATCH EXISTING

ADJACENT.

INFILL DOOR R.O. WITH

NEW FRAMING, FINISH

TO MATCH EXISTING

ADJACENT

REMOVE EXISTING THRESHOLD.

PROVIDE NEW ABA-COMPLIANT

THRESHOLD. SEE 3/ L-A102 FOR

THRESHOLD REQUIREMENTS.

REMOVE EXISTING THRESHOLD.

PROVIDE NEW ABA-COMPLIANT

THRESHOLD. SEE 3/ L-A102 FOR

THRESHOLD REQUIREMENTS.

ABA

COUNTERTOP

HT. @ +30" A.F.F. 3' - 6" 7' - 1"

1' - 6"

2' - 1"

COUNTERTOP

@ + 42" A.F.F.

PROVIDE NEW SCREEN/ STORM UNIT.

TYPE: FIXED TOP AND OPERABLE BOTTOM SASH

WITH EXTERIOR HALF SCREEN.

PROPOSED LODGE FLOOR PLAN KEY NOTES

RETAIN AND RESTORE HISTORIC SCREEN DOOR.

PROVIDE NEW SCREEN/ STORM UNIT.

TYPE: SINGLE REMOVABLE PANEL

WITH INTERCHANGEABLE SCREEN.

RETAIN AND RESTORE HISTORIC EXTERIOR DOOR. 5

REMOVE AND REPLACE DAMAGED DOOR THRESHOLD.

RETAIN AND RESTORE HISTORIC WINDOW.

2 2

NEW 3'-0" X 6'-8" X 1 3/8" THK.

SWINGING TRAFFIC DOOR,

VERTICAL PLANK APPEARANCE TO

MATCH EXISTING DOORS.

7PREPARE AND REFINISH WALLS IN THIS ROOM PER SCHEDULE.

8REMOVE AND REPLACE EXISTING COMPOSITE WALL PANELS

IN THIS ROOM PER SCHEDULE.

9PREPARE AND REFINISH CEILING IN THIS ROOM PER SCHEDULE.

10PROVIDE NEW DROPPED CEILING IN THIS ROOM.

11REFINISH AND REINSTALL RETAINED HARDWOOD FLOOR IN THIS ROOM.

ASSUME 25% SALVAGED HARDWOOD FLOORING, PROVIDE 75% NEW MATERIAL.

NOTE: ANY REQUIRED WOOD FLOORING SHALL MATCH EXISTING IN WOOD SPECIES,

SIZE, FINISH, AND RANDOM JOINT SPACING.

1 4

1 4

1 4

1 4

12PREPARE AND REFINISH FLOOR IN THIS ROOM PER SCHEDULE.

71012

71012 912 7

DS DS

DS

DS

DS

DS

DS

DS

FIELD LOCATE DOWNSPOUT

LOCATIONS. LOCATE AS

UNOBTRUSIVELY AS POSSIBLE.

NEW 2X4

CHASE

SEE M101

NEW SOFFIT

SEE NOTE 4,

L--P101

CLEAN AND RESTORE

INTERIOR AND EXTERIOR OF

EXISTING HISTORIC FIREPLACE AND

CHIMNEY. SEE D4/L-A302.

EXISTING ATTIC

ACCESS, ABOVE

LOCATION VIF

PROVIDE NEW

ATTIC ACCESS

NEW 3'-0" X 6'-8" X 1 3/8" THK.

FLUSH INTERIOR DOOR.

VERTICAL PLANK APPEARANCE TO

MATCH EXISTING DOORS.

5 5

INCREASE WIDTH OF ROOF OVER

EXTERIOR DOORS BY 6" AT

EXPOSED END(S) TO PROTECT

SHAPED BEAM.

TYP. @ (7) DOORS.

13KITCHEN EQUIPMENT SUPPLIED BY OWNER TYP UNO

3-COMPARTMENT

KITCHEN SINK

HANDS-FREE

HANDWASHING

STATION

FOOD PREP SINK

CLEAN AND REPAIR FLUE FOR

FULL FUNCTIONALITY. PROVIDE

INSPECTION REPORT FROM

CERTIFIED CHIMNEY SWEEP

CERTIFYING SAFE FOR WOOD

BURNING.

L-A102

TYP.

9' - 0"

15' - 0"LEVEL LANDING

PROVIDES ABA

MANEUVERING

SPACE

L-A102

TYP.

L-A102

SIM.

L-A102

SIM.

1' - 0"

EP-1EPOXY COATING

SCSEALED CONCRETE

FRP4' x 8' FRP PANEL ON 3/8" PLYWOOD

PNTEPOXY PAINT (SEMI-GLOSS FINISH)

TILEQUARRY TILE

ACTACOUSTIC CEILING TILE

CPUCEMENTITIOUS POLYURETHANE

POLYPOLYURETHANE WOOD FINISH

CONCCONCRETE

WDWOOD

EXEXISTING

KEYFRP-1 SHALL BE FIBERGLASS REINFORCED PLASTIC

PRELAMINATED TO PLYWOOD. FASTEN PANELS PER

MANUFACTURER'S INSTALLATION INSTRUCTIONS,

INCLUDING ADHESIVE AND NON-CORROSIVE

FASTENERS. ALLOW FOR DEFLECTION OF STRUCTURAL

MEMBERS. PROVIDE BATTEN STRIPS AT SEAMS.

NOTE:

SERVICE AREA DOOR

OFFSET PIVOT GRAVITY HINGE

PUSH/ PULL HARDWARE

NO LOCK

INTERIOR MECHANICAL ROOM DOOR

3 HINGES

PASSAGE SET DOOR LEVER

NO LOCK: DEADBOLT CORE HOLE AND JAMB

CUT & PLUGGED

HARDWARE SETSHARDWARE NOTES:

1. ALL HARDWARE SHALL BE

GRADE 1, HEAVY DUTY.

2. FINISH SHALL BE US10B,

DARK SATIN BRONZE, OIL

RUBBED.

3. ALL EXTERIOR DOORS

SHALL BE KEYED ALIKE.

4. RETAIN AND REUSE ALL

OTHER ORIGINAL DOOR

HARDWARE

ALL SCREEN DOORS

3 HINGES

PUSH/ PULL HARDWARE

NO LOCK

EXTERIOR DOORS (NOT SHOWER ROOMS)

3 HINGES

PASSAGE SET DOOR LEVER

DEADBOLT: CYLINDER x THUMBTURN

1/2"

PRE-MANUFACTURED ABA-COMPLIANT

DOOR THRESHOLD

1/2" MAXIMUM HEIGHT WITH 1:2 BEVEL

1/2" EXPANSION JOINT,

TYP. @ EXT. SLAB

6"

6"

6"

6"

2" HEMMED DRIP EDGE

1 1/2"

8"

FOLD IS

ROOF PITCH

FOLD IS

ROOF PITCH

GRIND OUT BED JOINT

WHERE NONE EXISTS

NOTE: MINIMIZE CUTS/GRINDING

AND OTHER DAMAGE TO EXISTING CHIMNEY

STEP FLASHING WEDGED &

MORTARED IN BED JOINT

CUT PAN FLASHING TO

OVERLAP @ RIDGE &

BEND AROUND CHIMNEY

EXISTING SHEATHING

EXISTINGNEW

EXISTINGNEW

NEW RIGID INSULATION

NEW SIDING

HEAD FLASHING w/

HEMMED DRIP EDGE

4" TOP LEG

NEW AIR BARRIER

NEW HEAD TRIM

2x3, RIP TOP FOR

POSITIVE DRAINAGE

EXTEND EXISTING OR RIP

NEW SILL, SLOPE TO DRAIN,

MATCH EXISTING (MIN. 15°)

w/ DRIP KERF

PAN FLASHING

w/ SIDE DAM & BACK DAM

2" LIP

ENGINEERING

ARCHITECTURE

PLANNING

SURVEYING

ENVIRONMENTAL

PROJECT TITLE:

OWNER:

PROJECT LOCATION:

PROJECT NO:

DRAWN BY:

CHECKED:

APPROVED:

12345

12345

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

DESIGNED BY:

DATE: ISSUED FOR:

100 PORTAGE STREET

HOUGHTON, MI 49931

(906) 482-4810

424 SOUTH PINE STREET

ISHPEMING, MI 49849

(906) 485-1011

707 ASHMUN ST.

SAULT STE. MARIE, MI 49783

(906) 635-0511

1701 DUNLAP AVE. SUITE B

MARINETTE, WI 54143

(715) 732-4188

2906 N. STEPHENSON AVE. SUITE 2

IRON MOUNTAIN, MI 49801

(906) 779-0937

P:\U 28-17435 U

SD

A FS-U

SFS C

N

N F M ondo - Boulder 17\D w gs\M ondeaux_base_D

W G

\U 28-17435_U

SFS-M

ondeaux_Lodge_Base.rvt

5/17/2019 12:49:28 PM

L-A102

PROPOSED LODGE

FLOOR PLAN

MONDEAUX

RECREATION SITE

RESTORATION AND

REHABILITATION

USDA FOREST

SERVICE

W7969 PARK RD,

WESTBORO, WI

54490

U28-17435

JDMA

KRC

TP

JDMA

Issue Date Project Status

1/4" = 1'-0" 3APROPOSED LODGE FLOOR PLAN

CHECK SET11-17-17

35% REVIEW11-22-2017

35% C2-27-18

65% REVIEW12-7-2018

95% REVIEW4-19-2019

REVISED 95% REVIEW5-9-2019

FINAL5-17-2019

ROOM FINISH SCHEDULE

ROOM NAME

FLOORWALLSCEILING

REMARKS MATERIALFINISHBASENORTHSOUTHEASTWESTMATERIALFINISH

MECHANICALCONCSC-PNTPNTPNTPNTEXPNT

KITCHENCONCTILETILEPNTPNTPNTPNTACT-

SERVICE AREACONCTILETILEPNTPNTPNTPNTACT-

LARGE DINING ROOMSEE KEYNOTES--------

SMALL DINING ROOMWDPOLY-PNTPNTPNTPNT--

LOBBYCONCTILETILEPNTPNTPNTPNT--

WOMENCONCCPUCPUFRPFRPFRPFRPEXPNT

MENCONCCPUCPUFRPFRPFRPFRPEXPNT

N. SHOWERCONCCPUCPUFRPFRPFRPFRPFRP-

S. SHOWERCONCCPUCPUFRPFRPFRPFRPFRP-

1 1/2" = 1'-0" 3ABA THRESHOLD, TYP.

1" = 1'-0" 4CHIMNEY FLASHING

1 1/2" = 1'-0" 5WINDOW FLASHING, TYP.

mbeuning Rectangle mbeuning Rectangle