This solicitation requests proposals for the Kenai Lake Work Center Water/Wastewater System Improvements project located in Seward, Alaska. The scope of work includes upgrading the existing water system, installing a new centralized wastewater treatment system and leach field, installing new sewer and building service laterals, and testing and commissioning all new systems. Optional items include asbestos abatement and demolition of an existing mess hall, replacing sewer piping, decommissioning existing septic systems, removing cabins, replacing well pumps and controls with new variable frequency drive controls, and providing a backup generator to power the well pumps. The estimated cost of construction is between $1 million and $5 million, with a period of performance through November 2024. Proposals are due by April 3, 2023. The Department of Agriculture Forest Service intends to award a single firm fixed price contract subject to availability of funds.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
ROXANNE D. ANDERSON
Project Name: Kenai Lake Work Center Water and Wastewater Construction, Seward Alaska
The purpose of this amendment #0002 is to:
1. Provide Questions and Answers to all contractors concerning this project (see following pages)
2. Provide 2 amendment 0002 attachments to help support and clarify questions
3. Change funding from "subject to availability" to now "Available to Fund".
Procurement & Property Services, Field Procurement Operations Northwest Zone – Construction & A-E Attn: Roxanne Anderson – Contracting Officer
1240BJ23R0004
1 1
04/10/2023
03/16/2023
Solicitation 1240BJ23R0004
Questions and Answers for the KLWC Water/Wastewater
1. Will other contractors be working on-site at the same time doing the next phases of construction (shown on phased construction drawing)?
No, those future phases are not yet funded.
2. Will access roads around the site be able to be closed off during construction?
Yes, this will need to be coordinated with Forest Service staff throughout the project. There is more than one access road to the various buildings on site, so closing one access road temporarily can be accomplished while maintaining access to the buildings.
3. Are there restricted work hours?
Yes. Work hours are stated in the Solicitation document on page 21 “Prosecution of Work: Construction activity shall be limited to the hours between 7:30 AM and 5:00 PM Monday through Friday, unless other hours are approved in writing by the Engineer. The Contractor shall conduct activities so that interference with the public shall be kept at a minimum. The project site shall be open to public access and free of hazards on weekends. Any activities requiring closure to the public shall be scheduled with the COR at least 7 days in advance.”
4. Do any of the buildings have lift stations associated with their existing septic systems?
Yes, the North Dorm and Flex housing. The main office also has a powered dosing station. The rest of the buildings have gravity drain to septic tank and drain field.
5. When is the anticipated time that funding will be available for the project?
Funding for this project is currently available and will be noted as an “update” within the Description Field on the Solicitation posting.
6. Does the Forest Service have an idea for the order of operations for construction, such as installing the advanced wastewater treatment system first?
The Forest Service does not have a set order of operations in mind. The Forest Service project team will work closely with the contractor to make a good plan of operations to minimize impact to staff and residents and develop a good plan. Plan will minimize shutdown of all facilities at once and minimize shutdown durations.
7. When is the peak season of employee use on-site?
June through September are the busiest months. Seasonals typically drop off in mid-September but recent staffing changes may have more people sticking around longer. Some seasonals stay until mid-October. The North and South Dorms are typically where seasonal staff is housed. The flex-housing is typically where longer-term staff resides year-round. We can move people around to various housing on-site to accommodate water/wastewater outages to each building. Field-going staff typically work Wednesday to Wednesday, so there are times when the dorms are less inhabited, and this could help with construction planning. May and June are the busiest times with the most staff on-site at KLWC. After that, staff are typically out in the field more and less time spent at KLWC. Staff who work in the office are typically on a Monday-Friday schedule.
8. Is there a desired timing for the demolition of the cabins and Mess Hall?
These are option items on the contract. The Forest Service is analyzing the order of operations and timing for demolishing these buildings in order to determine when and if these Option Items will be awarded.
9. Reference Section 312321 Dewatering. There appears to be no geotechnical information available for more than 9 feet in depth. TP-7, TP-8, TP-9, and TP-10 are all located within the wastewater treatment and Disposal System. These test pits are only nine feet deep. The excavation required for the septic tank installation will be deeper than this. It appears that the tank will sit below the surface elevation of Kenai Lake. Is the Forest service able to provide assumptions for bid regarding dewatering flows, or shoring requirements? Dewatering can be variable, and some guidance here would be appreciated.
The Forest Service does not have information on dewatering flows from past excavations. It is known, in general, that the site drains very well. Attached is the well log for the water well onsite, which gives information on material and water encountered when the well was drilled.
10. For Contract Line-Item No. 13 – please clarify what Pipes are to be replaced. Is this all piping inside of the pump house only? Is the pipe from the well to the pump house supposed to be replaced, including removal of pipe that penetrates through the pump house concrete floor? Or is everything other than the well casing supposed to be replaced?
This is only referring to the pipes down in the well casing that the pumps connect to.
11. Section 311101 Rock Excavation. Why is this specification included? Should a quantity of rock excavation be assumed? The geotechnical report doesn’t indicate rock layers.
Rock excavation is not expected at the KLWC site, but the Specification was included in case it is needed.
12. Drawing sheet C3.9, Detail A, Typical Sewer Pipe Trench Detail. Please verify the thickness of the pipe bedding. Similar to the water pipe trench detail on sheet C2.3 and as referenced in specifications, is bedding supposed to be 4” below up to 6” above the pipe?
Yes, this is correct for the Type 1 bedding (4” below, around, and 6” above the pipe). See specification Section 312100, Part 2.
13. Drawing sheet C3.9, Detail A, Typical Sewer Pipe Trench Detail. As well as sheet C2.3, Detail C, Typical water trench detail. Please indicate how tall the vertical sheets of insulation are to be. Are they two feet tall?
The vertical sheets of insulation should extend to the bottom of the trench before pipe bedding is installed. This way when the pipe bedding is laid, it can help support the insulation on the trench wall before the stick of pipe is installed.
14. Will the contractor be able to use water from the onsite water system? For instance, during compaction, if water is needed for compaction efforts. To flush the new waterline installed.
Yes, water from the onsite water system can be used by the contractor. If the Forest Service determines that the amount of water used by the contractor is too much for the system, the contractor will need to find an alternative source of water.
15. Are there any existing Telecom and electrical as-builts available?
As-builts of Telecom and electrical are not readily available. Attached is a site plan that was developed via a site survey by the Forest Service and includes approximate utility locations.
16. Reference Section 312300, Excavation and Fill, Part 3, subpart 3.4, Section A.1b: Please clarify if the testing service needs to be onsite at all times?
Testing service does not need to be onsite at all times. Testing service needs to be onsite at appropriate times during backfill and compaction in order to perform the tests at the locations directed by the government.
17. Refer to Drawing C3.10, Detal A and B. There is a specified 20” of 6” Aggregate Crushed Subbase. This material is specified in section 321116 Aggregate Subbase Course, Part 2. This material is something that is not made by supplier in Seward or Anchorage. Can this product be replaced with Subbase Grading A from the AKDOT Standard Specifications, Book 2020, Section 703, Subpart 703-2.09 subbase (shown below)? This is the typical subbase used in roadways for the DOT.
AKDOT Subbase A is an acceptable material, even though the No 4 sieve spec falls slightly outside defined parameters in the solicitation.
T
T T
T T
T T
T T
T T
T T
T
T
T
T T
T T
T T
T T
T T
T
T T
T T
TTTTTTTTTTTT
T
T T
T T
T T
T T
T T
T
T T
TT
T
T
T
T
T
T
T T
T T
T
T T
T T
T
T
T
T
T
T
T
T T
T
WWWW
W W
W W W
W W
W W
W
W
W
W
W
W
W W
W W
W
W
W
W
W
W
W
W
W
W
W
WW
W W
WWWW
W
W W
W
W W
W W
W W
W
WWWW
W
W W
W
W W
W
W W
W
W W
W
W
W W
W
W
W W
W
T old pump house
T
T T T T
PT 2
Elev.=453.3 FT
PT 3
Elev.=448.76 FT
PT 4
Elev.=450.0 FT
PT 11
Elev.=457.5 FT
PT 13
Elev.=450.9 FT
PT 15
Elev.=454.9 FT
T T
T T
T T
T T
T T
T
T
PT 59
Elev.=458.5 FT
PT 55
Elev.=453.1 FT
PT 56
Elev.=452.1 FT gas pump
W
SHEET 8
PT 51
PT 53
Elev.=458.1 FT
PT 7
Elev.=451.4 FT grate
PT 12
Elev.=451.2 FT gas pump shed
ASPHALT
fence
FT
sign, #2 sign, #4
GRAVEL ASPHALT
SHEET 10
GRAVEL
C R
EW
H O
U S E
M O
D
UL
AR
O
FF
IC
E
NO
RT
H D O
RM
SOUTH
DORM.
FLEX-H
O
U S
ING
U
NIT
W
AREH
O U S E
EQUIPMENT STORAGE
OFFICE
CAB
IN
CABIN
C
AB
IN
CABIN
CABIN
new pump house
RES
ID
EN
C E
(LAKE H
O
U S E)
FT
FT
FT
FT
FT
FT
FT
C
ARPEN
TER'S
S H O
P
PT 14
Elev.=452.5 FT
CABIN CABIN
shed shed
WCMC1
C3 concrete ramp sign, #6
FT
KENAI LAKE
FT
FT
SHEET 11
hazmat storage units
TRAC
T 3
TRAC
T 3
ALAS
KA RAILRO
AD
U S S
LO
T 1
TRAC
T 3
ALAS
KA RAILRO
AD
top of bank Parking Area
TRAC
T 3 trail
C2
PT 52
Elev.=
454.0 FT
PT 50 Elev.=454.9 FT
PT 58
Elev.=452.5 FT
FT
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey TITLE SHEET, LEGEND & SHEET INDEX TABLE
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 1 13
KEY:
HYD = fire hydrant.
s.t. = below ground septic tank.
m.h. = manhole cover
FT = above ground fuel tank.
WV = water valve.
c/o = cleanout
PT = survey point diam.= diameter
CMP = corrugated metal pipe
CPP = corrugated plastic pipe
(R) = Original BLM Record Plat and Field notes of US Survey No. 7398
SEE SHEET 12
SHEET INDEX
SHEET NO. TITLE
1 Title Sheet, Legend & Sheet Index Table
2 Site Topography & Notes
3 Underground Utilities & Sign Table
4 Septic System & Septic Tank Table
5 North Cabins & Lake Loop Road
6 Crew House, Carpenter Shop & Office Plan
7 KLWC Office, Modular Office & South Cabins
Warehouse, North Dorm & Equip.
Storage
9 Lake House & Misc. Bldgs.
10 Flex Housing & South Dorm.
11 Outside Storage & Pump House
12 Seward Hwy. & Access Road
13 Survey Control Table
T
E
RR
W
T_OH
E_OH
electrical line overhead electrical line telephone line overhead telephone line rail road track water line fence tree line/vegetation line trail curb sidewalk
Line Symbols:
monitoring well.
post, wood.
sign.
bollard (concrete filled metal1" diam. pipe).
sewer vent.
utility pole.
fire hydrant.
water valve.
water drain.
above ground fuel tank.
light pole on 2 Ft diam.
concrete footer telephone junction box.
electrical.
electrical meter.
Symbols:
USS 7398
Lot 1
This Project
LEGEND:
En la rg em en ts
A Standard Bureau of Land Management 3-14" diam.
brass cap on steel pipe found this survey.
A Standard USDA Forest Service 3-14" diam. alum.
cap on " diam. alum. drive rod, found this survey.
A standard Government Land Office 2-12" diam. brass cap on steel rod, found this survey.
A Standard USDA Forest Service 2-12" diam. alum.
cap on 58" diam. rebar, set this survey.
8" diam. rebar, found this survey.
8" diam. rebar w/ yellow Forest Service plastic cap set this survey.
2" diam. x 2" magnail, set this survey.
2" diam. x 2" magnail, found this survey.
8" diam. x 8" duranail spike, set this survey.
Monuments:
LEGEND:
old pump house
PT 2
Elev.=453.3 FT
PT 3
Elev.=448.76 FT
PT 4
Elev.=450.0 FT
PT 11
Elev.=457.5 FT
PT 13
Elev.=450.9 FT
PT 15
Elev.=454.9 FT
PT 59
Elev.=458.5 FT
PT 55
Elev.=453.1 FT
PT 56
Elev.=452.1 FT gas pump
PT 51
PT 53
Elev.=458.1 FT
PT 7
Elev.=451.4 FT grate
PT 12
Elev.=451.2 FT gas pump shed
ASPHALT
fence
FT
458 460 462
459459459 461
449 450
449 445
446 447 448 449
446447
448 449
445445
450 452449 451 sign, #2 sign, #4
456456456
GRAVEL ASPHALT
GRAVEL
C R
EW
H O
U S E
M O
D
UL
AR
O
FF
IC
E
NO
RT
H D O
RM
SOUTH
DORM.
FLEX-H
O
U S
ING
U
NIT
W
AREH
O U S E
EQUIPMENT STORAGE
OFFICE
CAB
IN
CABIN
C
AB
IN
CABIN
CABIN
new pump house
RES
ID
EN
C E
(LAKE H
O
U S E)
FT
FT
FT
FT
FT
FT
FT
C
ARPEN
TER'S
S H O
P
PT 14
Elev.=452.5 FT
CABIN CABIN
shed shed
WCMC1
C3 concrete ramp sign, #6
FT
KENAI LAKE
FT
FT
hazmat storage units
TRAC
T 3
TRAC
T 3
ALAS
KA RAILRO
AD
U S S
LO
T 1
TRAC
T 3
ALAS
KA RAILRO
AD
top of bank Parking Area trail
WV
C2
PT 52
Elev.=
454.0 FT
PT 50 Elev.=454.9 FT
PT 58
Elev.=452.5 FT
FT
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Site Topography & Notes
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 2 13
1. The purpose of this survey was to collect road, Building, underground utilities and existing topography at the Forest Service Kenai Lake Work Center (KLWC) located near milepost 23.5, Seward Hwy., Alaska for future planning and design.
2. The contour interval shown is 1 US Survey Foot.
3. All bearings and distances shown on this plat are grid unless otherwise noted.
4. All distances and elevations on this plat are calculated and shown in U.S. Survey feet.
5. Grid Coordinate values shown hereon are US State Plane, Zone 4, NAD83 (2011), US Survey Feet.
The ground scale factor computed at Control Point #1 is 1.0001088
6. Geographic Coordinates and Heights (HAE) shown hereon were determined using high precision GNSS RTK Survey methods based on a solution computed by the NGS OPUS utility for Control Point #1 (SRD 3167) and referenced to NAD83 (2011) (Epoch 2010.0000).
7. Elevations shown hereon are expressed as orthometric heights in US Survey Feet and are referenced to NAVD88. Elevations are based on the NGS OPUS utility solution for Control Point #1 noted above. Orthometric heights were determined by applying the geoidal height from NGS model Geoid 12B (Alaska).
8. Kenai Lake Work Center (KLWC) is located within Lot 1 United States Survey (USS) 7398 in Sec.
25, T. 4 N., R. 1 W., Seward Meridian.
Notes:
T
E
RR
W
T_OH
E_OH
electrical line overhead electrical line telephone line overhead telephone line rail road track water line fence tree line/vegetation line trail curb sidewalk
Line Symbols:
A Standard Bureau of Land Management 3-14" diam.
brass cap on steel pipe found this survey.
A Standard USDA Forest Service 3-14" diam. alum.
cap on " diam. alum. drive rod, found this survey.
A standard Government Land Office 2-12" diam. brass cap on steel rod, found this survey.
A Standard USDA Forest Service 2-12" diam. alum.
cap on 58" diam. rebar, set this survey.
8" diam. rebar, found this survey.
8" diam. rebar w/ yellow Forest Service plastic cap set this survey.
2" diam. x 2" magnail, set this survey.
2" diam. x 2" magnail, found this survey.
8" diam. x 8" duranail spike, set this survey.
Monuments:
LEGEND:
monitoring well.
post, wood.
sign.
bollard (concrete filled metal1" diam. pipe).
sewer vent.
utility pole.
fire hydrant.
water valve.
water drain.
above ground fuel tank.
light pole on 2 Ft diam.
concrete footer telephone junction box.
electrical.
electrical meter.
Symbols:
* See Details on Enlargement sheets 5 through 13
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE E
E
E
E
E
E
E E E E
E E
E E E
E
E
E
E E E
E E
E E
E E E
E
E E
E
E
E E
E
E
E
E E
E E
E E
E
E
E
T T
T T
T T
T T
T T
T T
T T
T
T
T
T T
T T
T T
T T
T T
T
T T
T T
TTTTTTTTTTTT
T
T T
T T
T T
T T
T T
T
T T
TT
T
T
T
T
T
T
T T
T T
T
T T
T T
T
T
T
T
T
T
T
T T
T
WWWW
W W
W W W
W W
W W
W
W
W
W
W
W
W W
W W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
WWWW
W
W W
W
W W
W W
W W
W
WWWW
W
W W
W
W W
W
W W
W
W W
W
E
E
E E
E
E E
E
W
W W
W
W
W W
W
T old pump house
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
T
T T T T
PT 2
Elev.=453.3 FT
PT 3
Elev.=448.76 FT
PT 4
Elev.=450.0 FT
PT 11
Elev.=457.5 FT
PT 13
Elev.=450.9 FT
PT 15
Elev.=454.9 FT
E E
E
T T
T T
T T
T T
T T
T
T
PT 59
Elev.=458.5 FT
PT 55
Elev.=453.1 FT
PT 56
Elev.=452.1 FT gas pump
W
PT 51
PT 53
Elev.=458.1 FT
PT 7
Elev.=451.4 FT grate
PT 12
Elev.=451.2 FT gas pump shed
E E
EEEEEEEE
EEEEEEEEEEEEEE
E
ASPHALT
fence
FT
sign, #2 sign, #4
GRAVEL ASPHALT
GRAVEL
C R
EW
H O
U S E
M O
D
UL
AR
O
FF
IC
E
NO
RT
H D O
RM
SOUTH
DORM.
FLEX-H
O
U S
ING
U
NIT
W
AREH
O U S E
EQUIPMENT STORAGE
OFFICE
CAB
IN
CABIN
C
AB
IN
CABIN
CABIN
new pump house
RES
ID
EN
C E
(LAKE H
O
U S E)
FT
FT
FT
FT
FT
FT
FT
C
ARPEN
TER'S
S H O
P
PT 14
Elev.=452.5 FT
CABIN CABIN
shed shed
WCMC1
C3 concrete ramp sign, #6
FT
KENAI LAKE
FT
FT
hazmat storage units
TRAC
T 3
TRAC
T 3
ALAS
KA RAILRO
AD
U S S
LO
T 1
TRAC
T 3
ALAS
KA RAILRO
AD
top of bank
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
Parking Area trail
WV
C2
PT 52
Elev.=
454.0 FT
PT 50 Elev.=454.9 FT
PT 58
Elev.=452.5 FT
FT
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Underground Utilities & Sign Table
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 3 13
SIGN TABLE
SIGN
POST SIGN
MESSAGE
SIZE MATERIAL SIZE MATERIAL
*1 2'-6" x 8' STONE
~ 6'-0" x 4'-0"
KLWC
~3-0' x 5-0"
USDA
~ 18" x12" FS
WOOD
Signs, (6) on stone base (3)either side
'Kenai Lake Work Center Chugach National Forest', 'U.S. Department of Agriculture', & 'U.S. Forest Service Department of Agriculture'
2 4" x 4" x 5.3' WOOD 1' x 1.5' METAL AUTHORIZED VEHICLES ONLY
3 4" x 4" x 5.3' WOOD 1' x 1.5' METAL AUTHORIZED VEHICLES ONLY
4 4" x 4" x 5' WOOD 1' x 1.5' METAL RESIDENTS ONLY
5 2" x 2" x 6' METAL 18" x 12" METAL HANDICAP PARKING
8" Diam
Utility Pole WOOD 18" x 12" METAL AUTHORIZED VEHICLES ONLY
* See sheet 12 for additional information on sign #1.
T
E
RR
W
T_OH
E_OH
electrical line overhead electrical line telephone line overhead telephone line rail road track water line fence tree line/vegetation line trail curb sidewalk
Line Symbols:
monitoring well.
post, wood.
sign.
bollard (concrete filled metal1" diam. pipe).
sewer vent.
utility pole.
fire hydrant.
water valve.
water drain.
above ground fuel tank.
light pole on 2 Ft diam.
concrete footer telephone junction box.
electrical.
electrical meter.
Symbols:
Notes:
1) Primary and secondary underground electric lines were located by the City of Seward, Electric Utilities Department in May 2016.
2) Underground telephone Lines were located by TelAlaska in April 2006.
3) Water Lines were located based on the KLWC Water System Reconstruction Systems as-built, dated October 1999 and the KLWC ICMAB Water Plans dated 2/28/2006.
Location of the aforementioned water lines and smaller local lines were also determined using a Fisher TW-8800 pipe and cable locator and through local knowledge provided by Mark Kromery , Lead Maintance worker @ KLWC in May 2016.
4) Local underground electric lines were located based on the KLWC ICMAB Electrical plans and determined using a Fisher TW-8800 pipe and cable locator in May 2016.
A Standard Bureau of Land Management 3-14" diam.
brass cap on steel pipe found this survey.
A Standard USDA Forest Service 3-14" diam. alum.
cap on " diam. alum. drive rod, found this survey.
A standard Government Land Office 2-12" diam. brass cap on steel rod, found this survey.
A Standard USDA Forest Service 2-12" diam. alum.
cap on 58" diam. rebar, set this survey.
8" diam. rebar, found this survey.
8" diam. rebar w/ yellow Forest Service plastic cap set this survey.
2" diam. x 2" magnail, set this survey.
2" diam. x 2" magnail, found this survey.
8" diam. x 8" duranail spike, set this survey.
Monuments:
LEGEND:
* See Details on Enlargement Sheets 5 through 12.
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE E
E
E
E
E
E
E E E E
E E
E E E
E
E
E
E E E
E E
E E
E E E
E
E E
E
E
E E
E
E
E
E E
E E
E E
E
E
E
T T
T T
T T
T T
T T
T T
T T
T
T
T
T T
T T
T T
T T
T T
T
T T
T T
TTTTTTTTTTTT
T
T T
T T
T T
T T
T T
T
T T
TT
T
T
T
T
T
T
T T
T T
T
T T
T T
T
T
T
T
T
T
T
T T
T
WWWW
W W
W W W
W W
W W
W
W
W
W
W
W
W W
W W
W
W
W
W
W
W
W
W
W
W
W
WW
W W
WWWW
W
W W
W
W W
W W
W W
W
WWWW
W
W W
W
W W
W
W W
W
W W
W
E
E
E E
E
E E
E
W
W W
W
W
W W
W
T old pump house
T
T T T T
PT 2
Elev.=453.3 FT
PT 3
Elev.=448.76 FT
PT 4
Elev.=450.0 FT
PT 11
Elev.=457.5 FT
PT 13
Elev.=450.9 FT
PT 15
Elev.=454.9 FT
E E
E
T T
T T
T T
T T
T T
T
T
PT 59
Elev.=458.5 FT
PT 55
Elev.=453.1 FT
PT 56
Elev.=452.1 FT gas pump
W
PT 51
PT 53
Elev.=458.1 FT
PT 7
Elev.=451.4 FT grate
PT 12
Elev.=451.2 FT gas pump shed
E E
EEEEEEEE
EEEEEEEEEEEEEE
E
ASPHALT
fence
FT
sign, #2 sign, #4
GRAVEL ASPHALT
GRAVEL
C R
EW
H O
U S E
M O
D
UL
AR
O
FF
IC
E
NO
RT
H D O
RM
SOUTH
DORM.
FLEX-H
O
U S
ING
U
NIT
W
AREH
O U S E
EQUIPMENT STORAGE
OFFICE
CAB
IN
CABIN
C
AB
IN
CABIN
CABIN
new pump house
RES
ID
EN
C E
(LAKE H
O
U S E)
FT
FT
FT
FT
FT
FT
FT
C
ARPEN
TER'S
S H O
P
PT 14
Elev.=452.5 FT
CABIN CABIN
shed shed
WCMC1
C3 concrete ramp sign, #6
FT
KENAI LAKE
FT
FT
hazmat storage units
TRAC
T 3
TRAC
T 3
ALAS
KA RAILRO
AD
U S S
LO
T 1
TRAC
T 3
ALAS
KA RAILRO
AD
top of bank
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
Parking Area trail
C2
PT 52
Elev.=
454.0 FT
PT 50 Elev.=454.9 FT
PT 58
Elev.=452.5 FT
FT
Leach Field
Leach Field
Le ac h Fi el d
Leach Field
Le ac h Fie ld
Leach Field
Leach F ield
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE:
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Septic System & Septic Tank Table
J. Wagner 5-20-2016
R. Schrank 9-12-2016
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 4 13
Leach Field s.t. #1 s.t. #2 s.t. #3 s.t. #10 s.t.
s.t. #4 s.t. #6
SEPTIC TANK TABLE
NUMBER BUILDING
CAPACITY
(GALLONS) SIZE
1 MESS HALL (Crew House) 1000 64" x 80"
2 CARPENTER SHOP 1000 64" x 80"
3 OFFICE 716 UNKNOWN
4 WAREHOUSE ~500 UNKNOWN
5 MODULAR OFFICE 1000 64" x 80"
6 KLWC Office 3000 75.5" x 168"
7 NORTH DORM 2000 64" x 152"
8 LAKE HOUSE 1000 64" x 80"
9 SOUTH DORM 3000 75.5" x 168"
10 FLEX HOUSING 3000 75.5" x 168"
Alaska Railroad
Tract 3
Le ac h Fie ld
T
E
RR
W
T_OH
E_OH
electrical line overhead electrical line telephone line overhead telephone line rail road track water line fence tree line/vegetation line trail curb sidewalk
Line Symbols:
A Standard Bureau of Land Management 3-14" diam.
brass cap on steel pipe found this survey.
A Standard USDA Forest Service 3-14" diam. alum.
cap on " diam. alum. drive rod, found this survey.
A standard Government Land Office 2-12" diam. brass cap on steel rod, found this survey.
A Standard USDA Forest Service 2-12" diam. alum.
cap on 58" diam. rebar, set this survey.
8" diam. rebar, found this survey.
8" diam. rebar w/ yellow Forest Service plastic cap set this survey.
2" diam. x 2" magnail, set this survey.
2" diam. x 2" magnail, found this survey.
8" diam. x 8" duranail spike, set this survey.
Monuments:
LEGEND:
monitoring well.
post, wood.
sign.
bollard (concrete filled metal1" diam. pipe).
sewer vent.
utility pole.
fire hydrant.
water valve.
water drain.
above ground fuel tank.
light pole on 2 Ft diam.
concrete footer telephone junction box.
electrical.
electrical meter.
Symbols:
Leach Field
Notes:
1) Septic Tank capacity and size obtained from Mark Kromery, Lead Maintenance Worker @ KLWC, May 2016.
2) Location and orientation of all underground septic tanks and leach fields are approximate only.
3) The Leach field for the Flex Housing Unit was located on the ground based on the Kenai Lake Work Center Flexible Housing Unit 1, Building Plans dated 1/11//2006.
4) The Leach Field for the KLWC Office was located on the ground based on the 'KLWC ICMAB' Site plan dated 2/28/2006.
5/ Leach Field locations for all other buildings are based on the 'KLWC Administrative site Work Center Area site development plan dated 4/29/1976. Location of these Leach fields shown heron are scaled from the plan drawings and could not be verified in the Field.
6) Approximate location of septic tanks and Leach Fields shown on this sheet only.
Leach Field
* See Details on Enlargement Sheets 5 through 12.
E
E E
E E
E E
E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
TT
T
TTTT
TTTTTTTTTTTTTTTTTTTTTT
T
T T
T
T
T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T
WWWWWW
W
W W
W W
W W
W W
W W
W W
W
WW
W W
W W
W
E
E
E
E
E
E
E
E
E
E
E
E E
E E
E E
E E
E E
E E E E
E E
E
EEEEEEEEEEEEEEEEEEEE
E
EEEEEE
E
E E
E E
E E
E
452451
SHEET 7
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey North Cabins & Lake Loop Road
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 5 13
S H
EE
T
10 Ft wood fence elec. transformer on 4 Ft x 4 Ft concrete pad elec. junction box on 6 Ft x 4 Ft concrete pad telephone junction box
Kenai lake overhead elec. line overhead telephone line elec. line (typ) telephone line (typ)
12" diam.
utility pole
PT 7
Elev. = 451.4 FT water line (typ) light pole (note 1) light pole (note 1) light pole (note 1) light pole (note 1)
Culvert #1 vent vent
Culvert #1 12" diam. x ±42 ft cpp invert elevations inlet: 448.5 ft outlet: 448.4 ft perched ±2.6 ft.
20 Ft
12 Ft
12 Ft20 Ft
19 Ft
12 Ft utility pole
PT 14
Elev. = 452.5 FT
PT 51
PT 6
Elev. = 442.8 FT
Treeline
Electric Lines
USS 2497 (Private)
WCMC1
trail footpaths
CABIN
CA
BIN
CABIN
USS 7398 Lot1 (Forest Service)
N 88° 44' E (R) true USS 2497 (Private)
USS 7398 Lot1 (Forest Service)
GRAVEL
Note:
1. Metal light pole on a 2 Ft.
diam. concrete footer.
2'x4' concrete pad
4.3'x12.0' wood deck wood stairs water valve (under 7" diam. cover)
USS 2497 (Private)
EEE
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T
T T
T
T
T
T
T T
T T
T T
T T
T
TTT
TTTTTTTTTTTTTTTTTTTTTTTTTTT
W W W
W W
W W
W W
W W
W W
W W
W W W W W W
W W
W
W W
W
W
W
W
W
W W
W W
W W
W
W
W W
WWWWWWWWW
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
T
T T
T
T T T T T T T T T T T T T T T T T
T T T T T T T
T
T
T
T T
T
T
TW
E E E
E
E E
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE
EEEEEEEEEEEEEEEEEEEEEEEEEE
456 458 460455 457 459
456 458457
458458458
FT
461453
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE:
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Crew House , Carpenter Shop & Office Plan
J. Wagner 5-20-2016
R. Schrank 9-12-2016
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 6 13
S H
EE
T antenna tower elec. transformer on 4 Ft x 4 Ft concrete pad elec. junction box telephone junction box (typ) sign, 4" x 4" wood post
1000 gal.
above grnd.
fuel tank above grnd. fuel tank (5 Ft Diam.)
electrical line (typ) water line (typ) overhead elec.
line (typ) c/o (note 1) loading dock (note 2) water valve under 7" diam. cover telephone line (typ) elec. junction box on 3 Ft x 6 Ft concrete pad
SHEET 8
drain drain wooden utility pole telephone junction box above grnd.
fuel tank
(5 Ft. Diam.)
C2
PT 9
Elev.=459.6 FT light pole ramp utility pole
SHEET 10
SHEET 7
telephone junction box
71 Ft
20 Ft
56 Ft
20 Ft
24 Ft
60 Ft
20 Ft
36 Ft
24 Ft
40 Ft wooden deck vents note 3
Drain Grate utility pole vent s.t.
64 Ft wooden utility pole
3' x 10' wooden loading dock elec. junc. box
C R
EW
H O
U S E
CARPENTERS SHOP
OFFICEcurb
PT 10
Elev.=456.9 FT
AK RR
Boundary
TRACT 38
AK Railroad elec. meter conduit box
C2 sign, 8" dia. utility pole.
curb
USS 7398 Lot1 (Forest Service)
USS
(Private)
N 88° 44' (R) true 361.68 Ft (R)
ASPHALT
AK Railroad Tract 3
S ° 1 ' E (R) true
U S S
Lot 1
(Forest S ervice) concrete sidewalk
Note:
1. 6 inch. diam. (s.t.) pvc cleanout vent.
2. 7.5 Ft x 10.5 Ft wooden loading dock.
3. 5 inch. diam. PVC cleanout vents (s.t.).
4. 2 Ft x 2 Ft concrete cover above 18 inch. diam. CMP w/ valves.
4.5' x 35' wooden deck.
concrete parking area curb concrete stairs crawl space access note 4 old grease trap
GOV'T LOT 5
(STATE of ALASKA)
Access Road
PT 8 Elev.=454.8 FT
PT 50 Elev.=454.9 FT
PT 53 ELEV.=458.1 FT
water valves
PT 52 Elev.=454.0 FT
E E
E E
E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E E
E E
E E
E E
E E
E
E
E
E
E
E
E
E E
E
E
E
E
EE
E E
E E
E E
E E
E E
E E
E E
E E
E
E E
E E
E E
E E
E E
E E
E
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T
T T
T
T
T
T
T T
T T
T T
T T
TT
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
E
E
E
E E
E E
E E
E E
E E
E
E E
E E
E E
E E
E E
E E
EE
E E
E
451 452
SHEET 5
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey KLWC OFFICE, MODULAR OFFICE & SOUTH CABINS
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 7 13
S H
EE
T
SHEET 9
sewer lift station
4.5 Ft diam. concrete cover
2 Ft x 2 Ft conc. pad
3 Ft wide rubber mat foot path
2.5 Ft. wide trail
(gravel) elec. transformer on 4 Ft x 4 Ft conc. pad elec. junction box (under 1 Ft x 1 Ft concrete cover) telephone junction box (typ) above grnd.
fuel tank (5 Ft Diam.)electrical line (typ) water line (typ) water valve (under 7" diam. cover) telephone line (typ) drain sign, (1) 4" x 4" wood post
5.5 Ft x 10 Ft
above grnd. fuel tank on 6 Ft x 14 Ft concrete pad elec. junction box light pole
Metal light pole on 2 Ft diam.
concrete footer light pole
4 Ft x 4 Ft conc. pad vent s.t.
13 Ft
52 Ft
20 Ft
12 Ft
20 Ft
12 Ft
24 Ft
1 Ft
100 Ft
98 Ft
40 Ft
20 Ft
12 Ft 15 Ft
10 Ft
22 Ft
12 Ft gravel m.h.
steam c/oradio tower on 2 Ft x 2 Ft conc. pad air conditioner on 4 Ft x 4 Ft conc. pad c/o vents
PT 13
Elev.=450.9 FT
PT 57
Elev.=452.2 FT
KLW
C O
FFIC
E telephone line (typ) cabin
M O
D U
LA
R O
FF
IC
E cabin cabin ca bi n cab in
2 Ft x 5 Ft conc. pad metal stairs w/ handrails
Fire Hydrant old culvert inlet elec. meterbox on wooden post electric junction box water line
Kenai lake elect. meter on timbers supported by wooden posts
FT
10 Ft wooden fence leach field
Top of bank
Edge of water on May 5, 2016
Top of bank
14 Ft x 16 Ft deck crawl space air vents
(CMP)
Note:
1. Metal light pole on a 2 inch diam. concrete footer.
4" diam.
PVC vents
4" diam. pvc monitor vents wood stairs water valves water valve bollard junction box on
3.5 Ft x 6.5 Ft
conc. pad
2.5 Ft diam manhole cover
treeline treeline
13 Ft x 16 Ft entryway
3 Ft wide gravel trail
(note 1)
(note 1)PT 5 Elev.=450.5 FT
PT 14
Elev.=452.5 FT
Leach Field
Leach Field trail (gravel) sidewalk light boxes flag pole sign, (1) 2" x 2" metal post
E
E
E
E E
E E
E E
E E
E E
E
E
E
E
E E
E E
E E
E
E
E
E
E
E E
E
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T
T
T
T
T
T
T T
T
T
T
T
T
WWWWWWWWWWWWWWWW
W W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
W W
W W
W W
W W
W W
W W
W W
W
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W W
W W
W W
W W
W W
W W
W W
W W
W
W
W
W
W
W
W W
W W
WW
W
WWWWWWWWWWWWWWWW
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
E_O H
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T
T T
T
T T
W
W
W
W
458458458
FT
FT
FT
FT
W W
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
T_O H
FT
SHEET 6
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Warehouse, North Dorm & Equipment Storage
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 8 13
S H
EE
T
SHEET 9
water valve under 7" diam.
cover electrical line (typ) water line (typ) telephone line (typ) drain above grnd. fuel tank (5 Ft Diam.)
water valves under 7 Ft diam. cover telephone junction box (typ) above grnd. fuel tanks on 7 Ft x 25 Ft concrete pad utility pole drain gas shed
5.4 Ft x 4.6 Ft
overhead elec. line above grnd. fuel tank (5 Ft Diam.)
overhead telephone line (typ) utility pole utility pole
SHEET 10
elec. junction box
33 Ft
76 Ft
33 Ft
97 Ft
86 Ft
36 Ft
PT 15
Elev.=454.9 FT
PT 54
Elev.=455.2 FT
PT 11
Elev.=457.5 FT
Fire Hydrant
Treeline
Fire Hydrant
Treeline
USS 7398
Lot 1
4.5 Ft square wooden cover on
3 Ft diam. CMP
W
AREH
O U S E
EQUIPMENT STORAGE
NO
RT
H D O
RM
curb concrete ramp w/ metal handrails concrete ramp w/ metal handrails
AKRR
Boundary
AK Railroad
TRACT 38
Overhead electric Lines curb
4 Ft x 86 Ft concrete slab monitoring well monitoring well
S
TO
RAG
E
C O
N
TAIN
ERS
18" diam. wooden utility pole
12" diam.
wooden utility pole
9.5 Ft x 10.5 Ft awning
sidewalk water valve under 7" diam. cover bollards
4 Ft x 54 Ft concrete walkway w/ metal rail
4 Ft x 35 Ft concrete slab
Tract 3 AK Railroad
S ° 1 ' E (R) true
U S S
Lot 1
(Forest S ervice)
GRAVEL
4 Ft x 7 Ft concrete slab bollard
4 Ft x 7.5 Ft bollards
5.8 Ft x 12 Ft
4" PVC
cleanout vents
4 Ft diam.
manhole cover cleanout cover water valves under 1 Ft x 1.5 Ft concrete casing
4 Ft x 5 Ft metal grate curb
ASPHALT
4" diam. PVC vents vent monitoring well bollard water valves under 7" diam.
cover utility pole water valve
GRAVEL
above grnd. fuel tank (5 Ft Diam.) (approx.)
E E
E E
E E
E E
E E
E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E E
E E
E
E
E
E
E E
E E
E E
E E
E
E
E
E
E
E
E
E
E E
EEEEEEEEEE
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E E E E E E E E E E E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E
E E
E E
E E
T T
T T
T T
T T
T T
T
T T
T T
T
T
T
T
T
T T
T T
T T
T
T
T
T
T
T T
T T
T T
T T
T
T T
T T
T T
T T
T T
T T
T T
T T
T T
T
T T
T
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W
W W
WWWWWW
W
W W
W
W
W
W
W W
W W
W W
W W
W W
W W
W
W W
W W
W W
W W
W W
W W
W
W W
W W
W W
W W
W
W W
W
W
W
W
W
W
W
W
W
W W
W W
W W
W W
W
W
W W
W
W
W
W
W
W W
W W
W W
W W
W W
W W
T T
T
TTTTTTTTTTT
454454
454 452
SHEET 8
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Lake House & Misc. Bldgs.
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 9 13
SHEET 7
shed
SOUTH DORM.
electrical line (typ) water line (typ) elec. transformer on 4 Ft x 4 Ft concrete pad water valve telephone junction box (typ) above grnd. fuel tank (5 Ft. Diam.)
drain elec. junction box on 3 Ft x 6 Ft concrete pad elec. junction box (not connected) elec.
junction box elec. transformer on 3 Ft x 6 Ft concrete pad drain bollard utility pole
SHEET 10
S H
EET 1
propane tank
14 Ft
19 Ft
15 Ft
17 Ft
24 Ft
59 Ft
RES
ID
EN
C E
(LAKE H
O
U S E) electrical line
Fire Hydrant
Treeline
Telephone Line
Treeline
Treeline
Treeline stone pavers concrete step
Treelines
PT 55
Elev.=453.1 FT
PT 4
Elev.=450.0 FT
PT 12
Elev.=451.2 FT
PT 56
Elev.=452.1 FT
2 Ft wide dirt trail sign, 4" x 4" wood post garden area
5" diam. PVC cleanout under a 1 Ft x 1.5 Ft concrete cover (st)
7" diam. PVC cleanout (st)
PARKING
AREA
water valves under 7" diam. covers
GRAVEL
bollard water valve under 7" diam. cover
6 Ft x 20 Ft concrete deck (slab)
9" diam. PVC vent (st) cleanout
PARKING
AREA
bollard
Treeline
Treeline
5 Ft x 10 Ft concrete slab top of bank bollard
5" diam. PVC vents s.t.
E
E E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E E
E E
E E
E E
E
E E
E
E
E
E
E
E E
E E
T
T T
T
T T
T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T
T T
T
T
T T
T T
T T
T T
T T
T
W
W
W
W
W W
W
W
W
W
W
W
W W
W W
W W
W W
W W
W
W
W
W
W
454 452
448 450 452447 449 451 453 454
446447
447447
445446
448 450449 451
SHEET 9
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Flex Housing & South Dormatory
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 10 13
7" diam. iron cleanout cover
3 Ft x 2.5 Ft metal drain telephone junction box
7 Ft x 12 Ft above grnd. fuel tank on 6 Ft x 18 Ft concrete pad electrical line (typ) water line telephone line (typ) elec. junction box on 4 Ft x 4 Ft concrete pad light pole above grnd. fuel tank (5 Ft. Diam.)
S H
EET 1
leach field culve rt #3
Culvert #2 12" diam. x ±25.5 ft cpp invert elevations inlet: 446.4 ft outlet: 446.2 ft
119 Ft
42 Ft
44 Ft
60 Ft
12" diam. cleanout cover on 3 Ft x 3 Ft concrete pad
FLEX-H
O
U S
ING
U
NIT
SOUTH DORM.PT 59
Elev.=458.5
PT 3
Elev.=448.8 FT
PT 58
Elev.=452.5 FT
PT 2
Elev.=453.3 FT
Timber (12" x 12" ) Crib
Timber (12" x 12") Retaining Wall metal light pole on 2 Ft diam. concrete footer light pole metal light pole f.t.
f.t.
s.t.
wooden stair w/ wooden handrail wooden stairs w/ wooden handrail treeline treeline top of bank
Edge of water on May 5, 2016
Culvert #3 12" diam. x ±52 ft cpp invert elevations inlet: 446.1 ft outlet: 445.3 ft culve rt #2 concrete ramp concrete stairs w/ metal handrail sidewalk
7" diam. iron sewer cleanout cover on 1 Ft x 1 Ft concrete pad
7" diam. iron sewer cleanout cover on 1 Ft x 1 Ft concrete pad
2 Ft diam.
manhole cover
6 Ft x 7 Ft concrete slab
PARKING AREA
crawl space air vents
(CMP)
6 Ft x 119 Ft walkway w/ handrails concrete stairs w/ metal handrails sidewalk
PARKING AREA
top of bank gravel elec. junction box on 4 Ft x 4 Ft concrete pad
Kenai lake
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Outside Storage & Pumphouse
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 11 13 electric line (typ)
(2) Hazmat Storage sheds (7 Ft x 16 Ft) on16 Ft x 41 Ft concrete pad
Outside Storage Area
2 Ft wide dirt trail
Treeline
New Pumphouse (11 Ft x 15 Ft)utility pole
3 Ft x 4 Ft concrete padwater line
1.5 Ft x 3 Ft Telephone
Junction Box on
4 Ft x 6 Ft concrete pad
PT 1
Elev.=455.5 FT
(SRD 3167)
PT 2
Elev.=453.3 FT
SHEET 9
S H
EE
T
SHEET 10
4.5 Ft square
wooden cover on 3 Ft diam. CMP
U S S
Lo t water valves & drain
Electrical junction Box (1.5 Ft x 5 Ft x 2.5 Ft h) on (3 Ft x 6 Ft) concrete pad
USS 7398 LOT 1
C4 overhead electric line telephone line
C3
Electrical Transformer Box 2.7 Ft x 2.7 Ft x 2 Ft h) on (4 Ft x 4 Ft) concrete pad
AK Railroad Tract 38 S14°
48' E
(R) tru e
USS 7283 Lot 1 (Forest Service) telephone junction box
PT 11
Elev.=457.5 FT
EQ
U
IP
M
EN
T
S
TO
RA
G
E
CONNEX
STORAGE
CONTAINERS
water valve (typ) telealaska junction box (2 Ft x 2.3 Ft x 5.5 Ft) mounted on a 14" diam.
wooden utility pole
1 Ft diam. steel pipe x 3 Ft high (wellhead) treeline
S10° 3 0' 25" E
(R) true
102.70 Ft (R)
electric line
4 Ft x 7 Ft concrete pad above ground fuel tank bollard utility pole light pole
Gas Shed
4.6 Ft x 5.4 Ft
AK Railroad Tract 38
AK Railroad Tract 38 S 0° 11
' E (R) tr ue
USS 7283 Lot 1 (Forest Service)
2 Ft x 5.4 Ft conc. pad utility pole utility pole bollards utility pole
GRAVEL
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE:
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME:LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey Seward Highway & Access Road
J. Wagner 5-20-2016
R. Schrank 9-12-2016
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 12 13
S H
EE
T
TRUE U
Access Road to KLWC
RR x-ing control house (6 Ft x 6 Ft) signs (3) mounted on rock wall w/ concrete base
RR X-ing
RR signal on 3 Ft x 5 Ft concrete pad
Alaska Railroad Tract 38 Bdry.
sign, #1 telephone junction box
To KLWC
Asphalt
To P riv at e Re si de nc e
Seward Highway
To Moose Pass
± M.
P. 23
.5
100 Ft
100 Ft
Alaska Railroad ℄
Tract 38
Alaska Railroad ℄
Tract 38
100 Ft
ROW
100 Ft
ROW
To Sew ard
Note:
Not all underground utilities or utility features are shown on this sheet.
SH of
USDA FOREST SERVICE - R10
CHUGACH NATIONAL FOREST
161 EAST 1st AVE., DOOR 8
ANCHORAGE, ALASKA 99501
DATE OF SURVEY:
BEGINNING DATE: 05-03-2016
ENDING DATE: 05-25-2016
DRAWN BY: DATE:
EQUIPMENT:
CHECKED BY: DATE: 9-12-2016
PROJECT NO.:
7035-16
SURVEY NOTE:
This Survey Current as of May 25, 2016.
DRAWING NAME: SCALE:
Horizontal
LOCATED: Chugach National Forest Seward Ranger District Secs 25, T. 4 N., R. 1 W., Seward Meridian
KENAI LAKE WORK CENTER
Site Survey SURVEY CONTROL TABLE
J. Wagner 5-20-2016
R. Schrank
Trimble R8 GNSS Receivers, Nikon NIVO 3.C Total Station, Spectra Precision Ranger 3 Data Collector w/ Survey Pro, Trimble TDL-450H Radio
KLWC_RD_SP_7035_16.dwg 13 13
CONTROL TABLE
POINT
STATE PLANE COORDINATES
US Survey Ft GEOGRAPHIC COORDINATES
DESCRIPTION
NO. NORTH EAST ELEV. LATITUDE LONGITUDE
HAE
US Survey Ft
2340660.3
1754151.6
3 455.5 N60°24'19.952" W149°22'15.433" 494.3 (SRD3167) 3-1/4" DIAM. USDA ALUM. CAP
2340551.6
1754019.8
6 453.3 N60°24'18.893" W149°22'18.077" 492.1 5/8" X 30" REBAR w/ YELLOW FS CAP
2340518.8
1753821.6
7 448.7 N60°24'18.589" W149°22'22.029" 487.5 (SRD3168) 3-1/4" USDA ALUM. CAP
2340786.6
1753583.7
0 450.0 N60°24'21.248" W149°22'26.716" 488.7 5/8" X 30" REBAR w/ 2-1/2" ALUM.FS CAP
2341085.2
8 1753525.81 450.5 N60°24'24.195" W149°22'27.812" 489.3 5/8" X 30" REBAR w/ 2-1/2" ALUM.FS CAP
2341271.7
1753399.5
6 442.8 N60°24'26.043" W149°22'30.290" 481.5 5/8" X 30" REBAR w/ YELLOW FS CAP
2341322.6
1753611.6
4 451.3 N60°24'26.524" W149°22'26.058" 490.1 5/8" X 30" REBAR w/ YELLOW FS CAP
2341290.6
1753887.0
8 454.8 N60°24'26.184" W149°22'20.580" 493.6 5/8" X 30" REBAR w/ 2-1/2" ALUM.FS CAP
2341356.6
1754180.2
4 459.6 N60°24'26.806" W149°22'14.731" 498.4 (S7398) 3-1/4" DIAM. BLM BRASS CAP
2341232.3
1754103.8
2 456.9 N60°24'25.589" W149°22'16.276" 495.7 5/8" X 30" REBAR w/ 2-1/2" ALUM.FS CAP
2340975.8
1754153.3
3 457.5 N60°24'23.058" W149°22'15.339" 496.3 5/8" X 30" REBAR w/ 2-1/2" ALUM.FS CAP
2340807.7
1753769.0
8 451.2 N60°24'21.439" W149°22'23.021" 490.0 5/8" X 8" DURANAIL
2340922.1
1753658.4
3 450.9 N60°24'22.576" W149°22'25.203" 489.7 5/8" X 30" REBAR w/ YELLOW FS CAP
2341136.9
1753639.7
9 452.5 N60°24'24.694" W149°22'25.533" 491.3 5/8" X 8" DURANAIL
2341149.2
1753887.8
7 454.9 N60°24'24.791" W149°22'20.591" 493.7 5/8" X 30" REBAR w/ 2-1/2" ALUM.FS CAP
2341288.9
1753900.7
0 454.9 N60°24'26.166" W149°22'20.309" 493.6 1/2" MAGNAIL
2341249.7
1753711.1
5 452.6 N60°24'25.798" W149°22'24.091" 491.3 5/8" X 30" REBAR w/ YELLOW FS CAP
2341184.7
1753837.2
3 454.0 N60°24'25.146" W149°22'21.593" 492.8 5/8" X 30" REBAR w/ YELLOW FS CAP
2341169.0
2 1754212.81 458.1 N60°24'24.955" W149°22'14.118" 496.9 5/8" X 30" REBAR w/ YELLOW FS CAP
2341099.0
5 1754030.11 455.2 N60°24'24.283" W149°22'17.769" 493.9 1/2" X 1" MAGNAIL
2340858.3
1753876.8
2 453.1 N60°24'21.927" W149°22'20.866" 491.8 5/8" X 30" REBAR w/ YELLOW FS CAP
2340699.9
1753840.5
6 452.1 N60°24'20.371" W149°22'21.619" 490.9 5/8" REBAR w/ YELLOW FS CAP
2340997.6
1753758.1
5 452.2 N60°24'23.311" W149°22'23.203" 491.0 5/8" X 30" REBAR w/ YELLOW FS CAP
2340604.6
1753917.8
8 452.5 N60°24'19.425" W149°22'20.097" 491.3 5/8" X 30" REBAR w/ YELLOW FS CAP
2340636.5
1753621.9
4 448.5 N60°24'19.766" W149°22'25.983" 487.2 5/8" X 30" REBAR w/ YELLOW FS CAP
| Amendment 0002_Attachment Site Plan KLWC.pdf |
| KLWC_RD_SP_7035_16_(Final)-Key |
| KLWC_RD_SP_7035_16_(Final)-Topo |
| KLWC_RD_SP_7035_16_(Final)-UGU |
| KLWC_RD_SP_7035_16_(Final)-Leach |
| KLWC_RD_SP_7035_16_(Final)-Plan 5 |
| KLWC_RD_SP_7035_16_(Final)-Plan 6 |
| KLWC_RD_SP_7035_16_(Final)-Plan 7 |
| KLWC_RD_SP_7035_16_(Final)-Plazn 8 |
| KLWC_RD_SP_7035_16_(Final)-Plan 9 |
| KLWC_RD_SP_7035_16_(Final)-Plan 10 |
| KLWC_RD_SP_7035_16_(Final)-Plan 11 |
| KLWC_RD_SP_7035_16_(Final)-Plan 12 |
| KLWC_RD_SP_7035_16_(Final)-Control |
File details come from the government source that posted it. Updated .