33PLMs-1-20-26-4384058_R1257169.pdf

PDF 3 MB Posted

Attached to
WRRC Boiler Upgrades Federal contract opportunity
Solicitation number
1232SA26R0033
Issued by
Department of Agriculture Agricultural Research Service

About this file

This is an Asbestos Polarized Light Microscopy (PLM) test report prepared by Eurofins Built Environment Testing West, LLC for Terracon Consultants, Inc. The report documents laboratory analysis of 33 building material samples collected on January 20, 2026, from the USDA Western Regional Research Center located at 800 Buchanan in Albany, California (Project R1257169).

The analysis identified zero samples with asbestos content exceeding 1% threshold. All 33 samples tested negative (ND) for asbestos across multiple material categories including green gaskets, concrete, fiberglass pipe insulation, white fiberglass sealants, pipe hangers, blue epoxy, and vinyl sheet flooring. Samples were analyzed using EPA 40CFR Appendix E and EPA METHOD 600/R-93-116 protocols by NVLAP-accredited laboratory (Lab Code 200757-0, EML ID 4384058). Analysis occurred on January 23, 2026, with samples received in acceptable condition on January 21, 2026. The report was issued January 26, 2026, and signed by approved signatory Danny Li with project analyst Nicole Levenson. Non-asbestos components identified in various samples included cellulose (5-15%), glass fibers (3-15%), and other matrix materials such as gypsum, paint, vinyl, and binders.

View the file

Other files for this federal contract opportunity

Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Approved by:

Approved Signatory Danny Li

Report for:

Heidi Santos, Ms. Karin Schroeter Terracon Consultants, Inc.-Concord 1220 Concord Avenue Suite 450 Concord, CA 94520

Regarding:

Eurofins Built Environment Testing West, LLC Project: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

EML ID: 4384058

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing West, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 01-23-2026

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EB-AS-S-1267) NVLAP Lab Code 200757-0

EMLab ID: 4384058, Page 1 of 13Eurofins Built Environment Testing West, LLC

Eurofins Built Environment Testing West, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

Total Samples Submitted: 33 Total Samples Analyzed: 33

Total Samples with Layer Asbestos Content > 1%: 0

Location: 1A, Green Gasket; Service Building East Mechanical Room- West Pump Lab ID-Version‡: 21979144-1

Sample Layers Asbestos Content Green Gasket ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 1B, Green Gasket; Service Building East Mechanical Room- Center Pump Lab ID-Version‡: 21979145-1

Sample Layers Asbestos Content Green Gasket ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 1C, Green Gasket; Service Building East Mechanical Room- Center East Pump Lab ID-Version‡: 21979146-1

Sample Layers Asbestos Content Green Gasket ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 2A, Concrete; Service Building East Mechanical Room- West Slab- West Side Lab ID-Version‡: 21979147-1

Sample Layers Asbestos Content Gray Concrete ND

Sample Composite Homogeneity: Moderate

EMLab ID: 4384058, Page 2 of 13Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

Location: 2B, Concrete; Service Building East Mechanical Room- West Slab- East Side

Lab ID-Version‡: 21979148-1

Sample Layers Asbestos Content Gray Concrete ND

Sample Composite Homogeneity: Moderate

Location: 2C, Concrete; Service Building West Mechanical Room- South Slab Lab ID-Version‡: 21979149-1

Sample Layers Asbestos Content Gray Concrete ND

Sample Composite Homogeneity: Moderate

Location: 3A, Fiberglass Pipe Insulation Paper Coating- Blue; Service Building- West Mech. Room- South Steam Boiler Lab ID-Version‡: 21979150-1

Sample Layers Asbestos Content White Wrap with Blue Paint ND

White Non-Fibrous Material (Plastic) ND Silver Foil Tape ND

Yellow Insulation ND Composite Non-Asbestos Content: 25% Cellulose

15% Glass Fibers Sample Composite Homogeneity: Poor

EMLab ID: 4384058, Page 3 of 13Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

Location: 3B, Fiberglass Pipe Insulation Paper Coating- Blue; Service Building- West Mech. Room- South Steam Boiler Lab ID-Version‡: 21979151-1

Sample Layers Asbestos Content White Wrap with Blue Paint ND

White Non-Fibrous Material (Plastic) ND Silver Foil Tape ND

Yellow Insulation ND Composite Non-Asbestos Content: 25% Cellulose

3% Glass Fibers Sample Composite Homogeneity: Poor

Location: 4A, Green Gasket; Main Building Basement- Mech Room F017-S Corner Pump Lab ID-Version‡: 21979152-1

Sample Layers Asbestos Content Green Gasket ND

Silver Paint (trace) ND Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 4B, Green Gasket; Main Building Attic- South Wing Lab ID-Version‡: 21979153-1

Sample Layers Asbestos Content Green Gasket ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 5A, Concrete; Main Building Basement- Mech Rm F017- South Lab ID-Version‡: 21979154-1

Sample Layers Asbestos Content Gray Concrete ND

Sample Composite Homogeneity: Moderate

EMLab ID: 4384058, Page 4 of 13Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

Location: 5B, Concrete; Main Building Basement- Mech Rm F017- South Lab ID-Version‡: 21979155-1

Sample Layers Asbestos Content Gray Concrete ND

Sample Composite Homogeneity: Moderate

Location: 6A, White Fiberglass Sealant; Main Building- Basement Mech Rm F017- Boiler 8 (N) Pipe Lab ID-Version‡: 21979156-1

Sample Layers Asbestos Content White Sealant with Yellow Fiberglass ND

Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate

Location: 6B, White Fiberglass Sealant; Main Building- Attic- South Wing Lab ID-Version‡: 21979157-1

Sample Layers Asbestos Content White Sealant with Yellow Fiberglass ND

Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate

Location: 6C, White Fiberglass Sealant; Main Building- Basement Auto-Clave Rm// Chase Rm 0037 Lab ID-Version‡: 21979158-1

Sample Layers Asbestos Content White Sealant with Yellow Fiberglass ND

Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate

Location: 6D, White Fiberglass Sealant; Main Building- Third Floor- Equip Rm 1- 302 Lab ID-Version‡: 21979159-1

Sample Layers Asbestos Content White Sealant with Yellow Fiberglass ND

Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate

EMLab ID: 4384058, Page 5 of 13Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

Location: 7A, Pipe Hanger; Main Building Basement- F515 Auto-Clave Rm Lab ID-Version‡: 21979160-1

Sample Layers Asbestos Content White Semi-Fibrous Material ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 7B, Pipe Hanger; Main Building Basement- F515 Auto-Clave Rm Lab ID-Version‡: 21979161-1

Sample Layers Asbestos Content White Semi-Fibrous Material ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 7C, Pipe Hanger; Main Building Basement- Auto-Clave/Chase Rm 0037 Lab ID-Version‡: 21979162-1

Sample Layers Asbestos Content White Semi-Fibrous Material ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 7D, Pipe Hanger; Main Building Basement- Research Equip Rm/Auto-Clave 0127 Lab ID-Version‡: 21979163-1

Sample Layers Asbestos Content White Semi-Fibrous Material ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 7E, Pipe Hanger; Main Building Basement- Third Floor- Equip Rm I-302 Lab ID-Version‡: 21979164-1

Sample Layers Asbestos Content White Semi-Fibrous Material ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 4384058, Page 6 of 13Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

Location: 8A, Blue Epoxy; Main Building Basement F515 Auto Clave Rm- SE Corner Lab ID-Version‡: 21979165-1

Sample Layers Asbestos Content Blue Non-Fibrous Material (Epoxy) ND

Sample Composite Homogeneity: Good

Location: 8B, Blue Epoxy; Main Building Basement F515 Auto Clave Rm- SE Corner Lab ID-Version‡: 21979166-1

Sample Layers Asbestos Content Blue Non-Fibrous Material (Epoxy) ND

Sample Composite Homogeneity: Good

Location: 9A, White Vinyl Sheet Floor w/ Brown Glue & Leveling Compound; Main Building Basement Autoclave Rm 0127- SE Corner Lab ID-Version‡: 21979167-1

Sample Layers Asbestos Content White Sheet Flooring with Fibrous Backing ND

Brown Glue ND White Leveling Compound ND

Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Location: 9B, White Vinyl Sheet Floor w/ Brown Glue & Leveling Compound; Main Building Basement Autoclave Rm 0127- SE Corner Lab ID-Version‡: 21979168-1

Sample Layers Asbestos Content White Sheet Flooring with Fibrous Backing ND

Brown Glue ND White Leveling Compound ND

Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

EMLab ID: 4384058, Page 7 of 13Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

Location: 10A, Fiberglass White Sealant; West Annex- First Floor Mech. Rm- NE Pipe Lab ID-Version‡: 21979169-1

Sample Layers Asbestos Content White Sealant with Yellow Fiberglass ND

Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate

Location: 10B, Fiberglass White Sealant; West Annex- First Floor Mech. Rm- SE Pipe Lab ID-Version‡: 21979170-1

Sample Layers Asbestos Content White Sealant with Yellow Fiberglass ND

Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate

Location: 10C, Fiberglass White Sealant; West Annex- First Floor Mech. Rm- West Pipe Lab ID-Version‡: 21979171-1

Sample Layers Asbestos Content White Sealant with Yellow Fiberglass ND

Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate

Location: 11A, Pipe Hanger; West Annez- First Floor Mech Rm- Center Lab ID-Version‡: 21979172-1

Sample Layers Asbestos Content White Semi-Fibrous Material ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 11B, Pipe Hanger; West Annez- First Floor Mech Rm- West Lab ID-Version‡: 21979173-1

Sample Layers Asbestos Content White Semi-Fibrous Material ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 4384058, Page 8 of 13Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

Location: 11C, Pipe Hanger; West Annez- First Floor Mech Rm- West Lab ID-Version‡: 21979174-1

Sample Layers Asbestos Content White Semi-Fibrous Material ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 12A, Green Gasket; West Annex- First Floor- Mech Rm- West Lab ID-Version‡: 21979175-1

Sample Layers Asbestos Content Green Gasket ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 12B, Green Gasket; West Annex- First Floor- Mech Rm- West Lab ID-Version‡: 21979176-1

Sample Layers Asbestos Content Green Gasket ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 4384058, Page 9 of 13Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/BuiltClient: Terracon Consultants, Inc.-Concord C/O: Heidi Santos, Ms. Karin Schroeter Re: R1257169; USDA Western Regional Research Center- 800 Buchanan Albany CA

Date of Sampling: 01-20-2026 Date of Receipt: 01-21-2026 Date of Report: 01-26-2026

ASBESTOS PLM REPORT

PROJECT ANALYST AND SIGNATORY REPORT

Project Analyst

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Analyst: Nicole Levenson

EMLab ID: 4384058, Page 10 of 13Eurofins Built Environment Testing West, LLC

File details come from the government source that posted it. Updated .