Errata Sheet.docx
DOCX document 17 KB Posted
- Solicitation number
- 12010920R0008
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment006.pdf | ||
| FH20-I-0077.PDF | ||
| Amendment 005.pdf | ||
| Amendment 004.pdf | ||
| 7 - Ex Admin Bldg.zip | ZIP file | |
| 9 - Upper Falls.zip | ZIP file | |
| 5 - Ex Obs - Shelter.zip | ZIP file | |
| 3 - Ex Obs - Lower Deck.zip | ZIP file | |
| 1 - Ex Obs - Upper Deck.zip | ZIP file | |
| 6 - Ex Obs - Trail.zip | ZIP file | |
| 4 - Ex Obs - Toilet Bldg.zip | ZIP file | |
| 0 - General.zip | ZIP file | |
| 2 - Ex Obs - Stairs.zip | ZIP file | |
| 8 - High Tide Access.zip | ZIP file | |
| Amendment 003.pdf | ||
| Final Construction Drawing Specifications.pdf | ||
| Final Construction Drawings.pdf | ||
| Amendment 002.pdf | ||
| Geological Report.pdf | ||
| Soil and Water.pdf | ||
| Amendment 001.pdf | ||
| SF24-16d Bid Bond Form.pdf | ||
| 12010920R0008_Anan_Observatory_RFP.pdf | ||
| Water_Quality_Mgmt_BMPs_April2012.pdf | ||
| Anan 95-percent Drawings.pdf | ||
| Wage Determination AK2020001.pdf | ||
| Anan 95-percent Technical Specifications.pdf | ||
| 12010920R0008_Anan_Observatory_RFP.pdf | ||
| Photographs.pdf |
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
12010920R0008 – Anan Wildlife Observatory Reconstruction Errata Sheet for Drawings and Specifications 08/24/2020
1. General:
a. In the context of soil, replace all instances of “unsuitable” with “unsatisfactory.”
b. Replace all instances of “Observatory Structure” with “Observation Structure.”
2. Amend the Final Construction Drawings as follows:
a. Drawing Sheet 10 – Trail Alignment Plan: Extend proposed contours to meet existing.
b. Drawing Sheet 12 – Observatory Area Details, Detail 1: Change fill slopes to 1.5H:1V.
c. Drawing Sheet 13 – Trailhead Area Signage Plan, Notes: Delete Note 1.
d. Drawing Sheet 15 – Admin Building Area Details, Detail 1: Add note “See Detail 1/Sheet 12 for Aggregate Pad Section Details.”
e. Drawing Sheet 19, Detail A: Add note “Slope on upper deck to be achieved via steel moment frame member placement.”
f. Drawing Sheet 20, Detail A: Add note “Provide half-round gutter on Lower Deck 2nd Floor, above where landing for lower deck 1st floor connect to 1st floor deck. Gutter to match shelter gutters.”
g. Drawing Sheet 28 – Detail D: Wood framed storage box to be on Grid S3. There will be three Gov’t furnished storage tanks under the storage box, and three Gov’t furnished storage tanks inside the toilet room.
h. Drawing Sheet 29, Detail 3 Shelter – Bench: Add note “Provide cedar vertical dividers, between bench base frames, at 2 ft on center. Dividers to provide visitors space to store backpacks and camera equipment during day trips.”
3. Amend the Final Construction Drawing Specifications as follows:
a. Section 32 15 00 – Aggregate Trail, Section 2.3 – Base Course: Delete “Subbase Grading A (2” minus),” replace with “Grading D (Base).”
File details come from the government source that posted it. Updated .