11-Attachment B Refined Crossings Structure Recommendations.pdf
PDF 861 KB Posted
- Solicitation number
- RFP-332-26
- Issued by
- Boulder County, Colorado
About this file
This file is a map and technical attachment from the US 36 Corridor - Safety For All - Wildlife Crossings Conceptual Design Review project in Boulder County, Colorado, prepared in partnership with the U.S. Forest Service and Boulder County Parks & Open Space. Attachment B presents refined crossing structure recommendations for wildlife mitigation along US-36 between Left Hand Creek (Milepost 27.95) and St. Vrain Creek (Milepost 21.8). The project area encompasses approximately 6.15 miles and identifies six specific crossing locations: two anchor point connectivity sites (MP 21.8 North End and MP 27.95 South End), one proposed bridge overpass (MP 24.75), one proposed arch underpass (MP 25), and two proposed arch or bridge underpasses (MP 22.6). The design includes continuous wildlife exclusion fencing along the corridor with gates or grates at driveways and intersections, plus wildlife jump-outs positioned at appropriate intervals. The primary infrastructure footprints are located within CDOT's Right of Way, with the overpass location also involving Boulder County Parks & Open Space property.
The map and structural recommendations document reflects the collaborative nature of this large multi-year infrastructure project involving Boulder County Parks & Open Space, the Colorado Department of Transportation (CDOT), and Colorado Parks and Wildlife (CPW). The 30% engineering design phase requires qualified contractors to develop detailed CDOT design plans, technical specifications, and cost estimates for the complete wildlife crossing system designed to accommodate multiple species. The project encompasses one overpass, three underpasses, exclusionary fencing, jump-outs, existing structure improvements, road and driveway modifications, construction access points, and staging areas. Impacts to properties beyond CDOT's Right of Way will be identified during the design phase, and additional property owner coordination may be necessary for project implementation.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
"J
"J
"J
"J
"J
"J
Left Hand Creek
NELSON RD
HYGIENE RD
LE
FT
HANDCANYON DR
ST VRAIN RD
Property of the US Government: Table Mountain Field Site
Saint Vrain Creek 66
MP 27.95, Anchor Point Connectivity - South End
MP 26.3, Proposed Bridge Underpass
MP 25, Proposed Arch Underpass
MP 24.75, Proposed Bridge Overpass
MP 22.6, Proposed Arch or Bridge Underpass
MP 21.8, Anchor Point Connectivity - North End
0 10.5 Miles n
D at e:
/4 /2
U se r:
kh ol m es
Pa th
: Z :\P ro je ct s\ j1
\M
AP
D O
C \U
S
B ik ew ay
P ro je ct
\U S
B ik ew ay P ro je ct .a pr x
M ap
: R ef in ed
C ro ss in g St ru ct ur e
R ec om m en da tio ns
La yo ut
: F ig ur e
R ef in ed C ro ss in g
St ru ct ur e R ec om m en da tio ns
Mile Post
Project Area of Focus
"J Project North End
"J Project South End
Recommended Wildlife Crossing "J Overpass
"J Underpass
Federal Land Forest Service
Bureau of Land Management
Table Mountain Field Site
Broad Ownership Category County Conservation Easement
County Owned Open Space
Miscellaneous Easement
Barnes Property (County Owned Open Space)
Open Space & Mountain Parks Property Type
Easement
Fee
SOURCE: USFS; Boulder County; ESRI Topographic
U.S. 36 Corridor - Safety For All - Wildlife Crossings Conceptual Design Review, Boulder County, Colorado
Refined Crossing Structure Recommendations
FIGURE 2
* Not Depicted - Wildlife exclusion fencing runs continuous from the South end of St. Vrain Creek Bridge (MP 21.8) to the South end of Left hand Creek bridge (MP 27.95). Driveways and intersections will have gates or grates and Wildlife Jump outs will occur at appropriate intervals
Attachment B: Refined Crossings Structure Recommendations
Accessibility Report
Filename:
Attachment B Refined Crossings Structure Recommendations.pdf
Report created by:
Organization:
[Enter personal and organization information through the Preferences > Identity dialog.]
Summary
The checker found problems which may prevent the document from being fully accessible.
Needs manual check: 2
Passed manually: 0
Failed manually: 0
Skipped: 0
Passed: 29
Failed: 1
Detailed Report
Document
Rule Name Status Description
Accessibility permission flag Passed Accessibility permission flag must be set
Image-only PDF Passed Document is not image-only PDF
Tagged PDF Passed Document is tagged PDF
Logical Reading Order Needs manual check Document structure provides a logical reading order
Primary language Passed Text language is specified
Title Passed Document title is showing in title bar
Bookmarks Passed Bookmarks are present in large documents
Color contrast Needs manual check Document has appropriate color contrast
Page Content
Rule Name Status Description
Tagged content Failed All page content is tagged
Tagged annotations Passed All annotations are tagged
Tab order Passed Tab order is consistent with structure order
Character encoding Passed Reliable character encoding is provided
Tagged multimedia Passed All multimedia objects are tagged
Screen flicker Passed Page will not cause screen flicker
Scripts Passed No inaccessible scripts
Timed responses Passed Page does not require timed responses
Navigation links Passed Navigation links are not repetitive
Forms
Rule Name Status Description
Tagged form fields Passed All form fields are tagged
Field descriptions Passed All form fields have description
Alternate Text
Rule Name Status Description
Figures alternate text Passed Figures require alternate text
Nested alternate text Passed Alternate text that will never be read
Associated with content Passed Alternate text must be associated with some content
Hides annotation Passed Alternate text should not hide annotation
Other elements alternate text Passed Other elements that require alternate text
Tables
Rule Name Status Description
Rows Passed TR must be a child of Table, THead, TBody, or TFoot
TH and TD Passed TH and TD must be children of TR
Headers Passed Tables should have headers
Regularity Passed Tables must contain the same number of columns in each row and rows in each column
Summary Passed Tables must have a summary
Lists
Rule Name Status Description
List items Passed LI must be a child of L
Lbl and LBody Passed Lbl and LBody must be children of LI
Headings
Rule Name Status Description
Appropriate nesting Passed Appropriate nesting
Back to Top
File details come from the government source that posted it. Updated .