11-Attachment B Refined Crossings Structure Recommendations.pdf

PDF 861 KB Posted

Attached to
US36 Wildlife Crossings 30% Engineering Design Project
Solicitation number
RFP-332-26
Issued by
Boulder County, Colorado

About this file

This file is a map and technical attachment from the US 36 Corridor - Safety For All - Wildlife Crossings Conceptual Design Review project in Boulder County, Colorado, prepared in partnership with the U.S. Forest Service and Boulder County Parks & Open Space. Attachment B presents refined crossing structure recommendations for wildlife mitigation along US-36 between Left Hand Creek (Milepost 27.95) and St. Vrain Creek (Milepost 21.8). The project area encompasses approximately 6.15 miles and identifies six specific crossing locations: two anchor point connectivity sites (MP 21.8 North End and MP 27.95 South End), one proposed bridge overpass (MP 24.75), one proposed arch underpass (MP 25), and two proposed arch or bridge underpasses (MP 22.6). The design includes continuous wildlife exclusion fencing along the corridor with gates or grates at driveways and intersections, plus wildlife jump-outs positioned at appropriate intervals. The primary infrastructure footprints are located within CDOT's Right of Way, with the overpass location also involving Boulder County Parks & Open Space property.

The map and structural recommendations document reflects the collaborative nature of this large multi-year infrastructure project involving Boulder County Parks & Open Space, the Colorado Department of Transportation (CDOT), and Colorado Parks and Wildlife (CPW). The 30% engineering design phase requires qualified contractors to develop detailed CDOT design plans, technical specifications, and cost estimates for the complete wildlife crossing system designed to accommodate multiple species. The project encompasses one overpass, three underpasses, exclusionary fencing, jump-outs, existing structure improvements, road and driveway modifications, construction access points, and staging areas. Impacts to properties beyond CDOT's Right of Way will be identified during the design phase, and additional property owner coordination may be necessary for project implementation.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

"J

"J

"J

"J

"J

"J

Left Hand Creek

NELSON RD

HYGIENE RD

LE

FT

HANDCANYON DR

ST VRAIN RD

Property of the US Government: Table Mountain Field Site

Saint Vrain Creek 66

MP 27.95, Anchor Point Connectivity - South End

MP 26.3, Proposed Bridge Underpass

MP 25, Proposed Arch Underpass

MP 24.75, Proposed Bridge Overpass

MP 22.6, Proposed Arch or Bridge Underpass

MP 21.8, Anchor Point Connectivity - North End

0 10.5 Miles n

D at e:

/4 /2

U se r:

kh ol m es

Pa th

: Z :\P ro je ct s\ j1

\M

AP

D O

C \U

S

B ik ew ay

P ro je ct

\U S

B ik ew ay P ro je ct .a pr x

M ap

: R ef in ed

C ro ss in g St ru ct ur e

R ec om m en da tio ns

La yo ut

: F ig ur e

R ef in ed C ro ss in g

St ru ct ur e R ec om m en da tio ns

Mile Post

Project Area of Focus

"J Project North End

"J Project South End

Recommended Wildlife Crossing "J Overpass

"J Underpass

Federal Land Forest Service

Bureau of Land Management

Table Mountain Field Site

Broad Ownership Category County Conservation Easement

County Owned Open Space

Miscellaneous Easement

Barnes Property (County Owned Open Space)

Open Space & Mountain Parks Property Type

Easement

Fee

SOURCE: USFS; Boulder County; ESRI Topographic

U.S. 36 Corridor - Safety For All - Wildlife Crossings Conceptual Design Review, Boulder County, Colorado

Refined Crossing Structure Recommendations

FIGURE 2

* Not Depicted - Wildlife exclusion fencing runs continuous from the South end of St. Vrain Creek Bridge (MP 21.8) to the South end of Left hand Creek bridge (MP 27.95). Driveways and intersections will have gates or grates and Wildlife Jump outs will occur at appropriate intervals

Attachment B: Refined Crossings Structure Recommendations

Accessibility Report

Filename:

Attachment B Refined Crossings Structure Recommendations.pdf

Report created by:

Organization:

[Enter personal and organization information through the Preferences > Identity dialog.]

Summary

The checker found problems which may prevent the document from being fully accessible.

Needs manual check: 2

Passed manually: 0

Failed manually: 0

Skipped: 0

Passed: 29

Failed: 1

Detailed Report

Document

Rule Name Status Description

Accessibility permission flag Passed Accessibility permission flag must be set

Image-only PDF Passed Document is not image-only PDF

Tagged PDF Passed Document is tagged PDF

Logical Reading Order Needs manual check Document structure provides a logical reading order

Primary language Passed Text language is specified

Title Passed Document title is showing in title bar

Bookmarks Passed Bookmarks are present in large documents

Color contrast Needs manual check Document has appropriate color contrast

Page Content

Rule Name Status Description

Tagged content Failed All page content is tagged

Tagged annotations Passed All annotations are tagged

Tab order Passed Tab order is consistent with structure order

Character encoding Passed Reliable character encoding is provided

Tagged multimedia Passed All multimedia objects are tagged

Screen flicker Passed Page will not cause screen flicker

Scripts Passed No inaccessible scripts

Timed responses Passed Page does not require timed responses

Navigation links Passed Navigation links are not repetitive

Forms

Rule Name Status Description

Tagged form fields Passed All form fields are tagged

Field descriptions Passed All form fields have description

Alternate Text

Rule Name Status Description

Figures alternate text Passed Figures require alternate text

Nested alternate text Passed Alternate text that will never be read

Associated with content Passed Alternate text must be associated with some content

Hides annotation Passed Alternate text should not hide annotation

Other elements alternate text Passed Other elements that require alternate text

Tables

Rule Name Status Description

Rows Passed TR must be a child of Table, THead, TBody, or TFoot

TH and TD Passed TH and TD must be children of TR

Headers Passed Tables should have headers

Regularity Passed Tables must contain the same number of columns in each row and rows in each column

Summary Passed Tables must have a summary

Lists

Rule Name Status Description

List items Passed LI must be a child of L

Lbl and LBody Passed Lbl and LBody must be children of LI

Headings

Rule Name Status Description

Appropriate nesting Passed Appropriate nesting

Back to Top

File details come from the government source that posted it. Updated .