About this file
This is a Plot Plans document for the City of Scranton's Levee Storm Pipe Inspection project in Pennsylvania. The document provides technical specifications and drawing references for a stormwater pipe inspection project involving multiple drainage structures owned by the City of Scranton and Pennsylvania American Water Company (PAWC) along the Scranton levee system. The contract work focuses on inspecting City of Scranton-owned stormwater pipe penetrations, with specific identification of 23 drainage structures and associated NPDES outfall numbers. The project utilizes historical U.S. Army Corps of Engineers record drawings as base information, with engineer annotations identifying the specific facilities to be inspected under the contract. Bids for this project are due by 10:00 am on Thursday, December 3, 2026, submitted electronically through the City's e-Procurement Portal, with bid opening to follow in City Council Chambers on the second floor of City Hall.
The document establishes that existing conditions, pipe locations, dimensions, materials, elevations, ownership, and accessibility information depicted on historical record drawings are considered approximate and must be verified by the contractor. Only pipe penetrations specifically identified by project annotations as City of Scranton facilities are included in the base bid, with any variations requiring direction from the owner or engineer. The complete historical record drawing set is available upon request to bidders. No pricing information, set-asides, incumbent contractor details, or specific funding sources are detailed in this plot plans document.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTE:
HISTORICAL U.S. ARMY CORPS OF ENGINEERS RECORD
DRAWINGS HAVE BEEN UTILIZED AS BASE INFORMATION
FOR THIS PROJECT. THE RECORD DRAWINGS MAY DEPICT
UTILITIES AND FACILITIES NOT OWNED BY THE CITY OF
SCRANTON AND NOT INCLUDED IN THIS CONTRACT. ONLY
PIPE PENETRATIONS SPECIFICALLY IDENTIFIED BY THE
PROJECT ANNOTATIONS AS CITY OF SCRANTON
FACILITIES TO BE INSPECTED ARE INCLUDED IN THE BASE
BID, UNLESS OTHERWISE DIRECTED BY THE OWNER OR
ENGINEER.
THE CONTRACT DRAWINGS CONSIST OF SELECTED
HISTORICAL U.S. ARMY CORPS OF ENGINEERS RECORD
DRAWINGS THAT HAVE BEEN ANNOTATED BY THE
ENGINEER TO IDENTIFY CITY OF SCRANTON-OWNED
STORMWATER PIPE PENETRATIONS INCLUDED IN THE
WORK.
THE UNDERLYING RECORD DRAWINGS DEPICT
HISTORICAL CONDITIONS AND ARE PROVIDED AS THE
BASIS FOR LOCATING THE EXISTING LEVEE SYSTEM,
DRAINAGE STRUCTURES, PIPE PENETRATIONS, AND
OTHER FACILITIES. THE ANNOTATIONS ADDED FOR THIS
PROJECT IDENTIFY THE FACILITIES INTENDED FOR
INSPECTION UNDER THIS CONTRACT.
EXISTING CONDITIONS, PIPE LOCATIONS, DIMENSIONS,
MATERIALS, ELEVATIONS, OWNERSHIP, ACCESSIBILITY,
AND OTHER INFORMATION SHOWN ON THE HISTORICAL
RECORD DRAWINGS SHALL BE CONSIDERED
APPROXIMATE AND SHALL BE VERIFIED BY THE
CONTRACTOR AS NECESSARY TO PERFORM THE WORK.
ONLY HISTORICAL RECORD DRAWING SHEETS RELEVANT
TO THE WORK HAVE BEEN INCLUDED IN THE CONTRACT
DRAWINGS. THE COMPLETE HISTORICAL RECORD
DRAWING SET MAY BE PROVIDED TO THE CONTRACTOR
UPON REQUEST.
PLOT PLANS
DRAINAGE STRUCTURE 505 -
SCRANTON
DRAINAGE STRUCTURE 506 -
PAWC
NPDES OUTFALL NO. 37
DRAINAGE STRUCTURE 504 -
PAWC
DRAINAGE STRUCTURE 503 -
PAWC
DRAINAGE STRUCTURE 502 -
PAWC
NPDES OUTFALL NO. 38
DRAINAGE STRUCTURE 501 -
DRAINAGE STRUCTURE 511 -
DRAINAGE STRUCTURE 509 -
PAWC
DRAINAGE STRUCTURE
"508A" - SCRANTON
DRAINAGE STRUCTURE 508 -
SCRANTON
DRAINAGE STRUCTURE 507 -
PAWC
EX. DRAINAGE STRUCTURE
10 - PAWC (TWO LINES -
OVERVLOW AND STORM
WATER DISCHARGE PUMP)
NPDES OUTFALL NO. 78
DRAINAGE STRUCTURE 512 -
DRAINAGE STRUCTURE 516 -
PAWC
DRAINAGE STRUCTURE 515 -
SCRANTON
DRAINAGE STRUCTURE 514 -
DRAINAGE STRUCTURE 517 -
DRAINAGE STRUCTURE SAN
503 - PAWC
EX. DRAINAGE STRUCTURE
13 - PAWC
NPDES OUTFALL NO. 33
| 001-Pcover_25306_2 |
| Pcover_25306_2.dwg |
| 002-PCG015306_2 |
| PCG015306_2.dwg |
| 003-PCG025306_2 |
| PCG025306_2.dwg |
| 004-PCG035306_2 |
| PCG035306_2.dwg |
| 005-PCG045306_2 |
| PCG045306_2.dwg |
| 006-PCG055306_2 |
| PCG055306_2.dwg |
| 007-PCG065306_2 |
| PCG065306_2.dwg |
| 013-GC065306_2 |
| GC065306_2.dwg |
| 014-GC075306_2 |
| GC075306_2.dwg |
| 015-PC085306_2 |
| PC085306_2.dwg |
| 016-PC095306_2 |
| PC095306_2.dwg |
| 017-PC105306_2 |
| PC105306_2.dwg |
| 018-PC115306_2 |
| PC115306_2.dwg |
| 019-PC125306_2 |
| PC125306_2.dwg |
| 023a-GC16a5306_2 |
| GC16a5306_2.dwg |
| 023b-GC16b5306_2 |
| GC16b5306_2.dwg |
| 023c-GC16c5306_2 |
| GC16c5306_2.dwg |
| 023-GC165306_2 |
| GC165306_2.dwg |
| 025-PC185306_2 |
| PC185306_2.dwg |
| 026-PC195306_2 |
| PC195306_2.dwg |
| 027-PC205306_2 |
| PC205306_2.dwg |
| 028-PC215306_2 |
| PC215306_2.dwg |
| 035-GC285306_2 |
| GC285306_2.dwg |
| 040-GC335306_2 |
| GC335306_2.dwg |
| 041-GC345306_2 |
| GC345306_2.dwg |
| 042-PC355306_2 |
| PC355306_2.dwg |
| 043-PC365306_2 |
| PC365306_2.dwg |
| 044-PC375306_2 |
| PC375306_2.dwg |
| 045-PC385306_2 |
| PC385306_2.dwg |
| 046-PC395306_2 |
| PC395306_2.dwg |
| 047-PC405306_2 |
| PC405306_2.dwg |
| 048-PC415306_2 |
| PC415306_2.dwg |
| 049-PC425306_2 |
| PC425306_2.dwg |
| 054-GC475306_2 |
| GC475306_2.dwg |
| 055-PC485306_2 |
| PC485306_2.dwg |
| 056-PC495306_2 |
| PC495306_2.dwg |
| 057-GC505306_2 |
| GC505306_2.dwg |
| 060-PC535306_2 |
| PC535306_2.dwg |
| 065-GC585306_2 |
| GC585306_2.dwg |
| 066-PC595306_2 |
| PC595306_2.dwg |
| 067-PC605306_2 |
| PC605306_2.dwg |
| 069-PC625306_2 |
| PC625306_2.dwg |
| 072-PC655306_2 |
| PC655306_2.dwg |
| 075-PC685306_2 |
| PC685306_2.dwg |
| 076-PC695306_2 |
| PC695306_2.dwg |
| 077-PC705306_2 |
| PC705306_2.dwg |
| 078-PC715306_2 |
| PC715306_2.dwg |
| 079-PS01A5306_2 |
| PS01A5306_2.dwg |
| 080-PS02A5306_2 |
| PS02A5306_2.dwg |
| 081-PS03A5306_2 |
| PS03A5306_2.dwg |
| 084-PS06A5306_2 |
| PS06A5306_2.dwg |
| 085-PS07A5306_2 |
| PS07A5306_2.dwg |
| 086-PS08A5306_2 |
| PS08A5306_2.dwg |
| 087-PS09S5306_2 |
| PS09S5306_2.dwg |
| 088-PS10A5306_2 |
| PS10A5306_2.dwg |
| 089-PS11A5306_2 |
| PS11A5306_2.dwg |
| 090-PS12A5306_2 |
| PS12A5306_2.dwg |
| 091-PS13A5306_2 |
| PS13A5306_2.dwg |
| 093-PS15A5306_2 |
| PS15A5306_2.dwg |
| 094-PS16A5306_2 |
| PS16A5306_2.dwg |
| 095-PS17A5306_2 |
| PS17A5306_2.dwg |
| 096-PS18A5306_2 |
| PS18A5306_2.dwg |
| 097-PS19A5306_2 |
| PS19A5306_2.dwg |
| 098-PS20A5306_2 |
| PS20A5306_2.dwg |
| 099-PS21A5306_2 |
| PS21A5306_2.dwg |
File details come from the government source that posted it. Updated .