Exhibit C1_Room List v.260616.pdf

PDF 1 MB Posted

Attached to
General Services Administration (GSA) seeks to lease Office space in Santa Barbara, CA
Solicitation number
0CA3254
Issued by

About this file

This is a Program Room List and space planning document for the U.S. Bankruptcy Court in Santa Barbara, dated June 16, 2026, serving as Exhibit C1 to a lease agreement. The document specifies detailed requirements for approximately 13,219 usable square feet (15,202 rentable square feet) of court facilities across four functional areas: Court Shared Support Space (1,711 USF), Bankruptcy Judge Chambers Suites (2,503 USF), Courtroom and Associated Spaces (4,115 USF), and Bankruptcy Clerk areas (4,890 USF).

The document provides comprehensive specifications for 50+ individual rooms and spaces, including detailed requirements for floor finishes (carpet tile, vinyl, broadloom), wall treatments, ceiling systems, sound transmission class ratings, door specifications, and mechanical/plumbing requirements. Network equipment requirements include 1 42U floor-anchored and grounded rack, 2 Cisco 3000VA UPS units, 2 Cisco 9300 series 48-port switches, 2 Cisco 4000 series routers, approximately 120 total network drops at 1 Gb/s, and 120 total terminations. The courtroom specifications call for 2–4 inches of access flooring in the well area, speaker systems, virtual judge monitor capability with millwork modifications, spectator seating for 60, and dedicated infrastructure for presentation technology and audiovisual systems. Additional requirements include dedicated circuits for equipment, specialized storage for evidence and records, security screening infrastructure, and multiple support spaces such as judge chambers suites, law clerk offices, attorney/witness rooms, and public facilities.

View the file

Other files

File Type Posted
Request for Lease Proposals (RLP).pdf PDF
Exhibit C3_USCDC RDS v.260616.pdf PDF
Exhibit F_Form 1364 Proposal to Lease Space (Jan. 2023).pdf PDF
Exhibit H_Prelease Evaluation Form 12000 (May 2015).pdf PDF
Exhibit I_Seismic Forms A - F with Instructions.pdf PDF
Exhibit G_GSA Form 1217 (Nov. 2016).pdf PDF
Exhibit J_GSAR Representation 552.270-33 (Nov. 2024).pdf PDF
Exhibit C4_Millwork v.260616.pdf PDF
Exhibit E_3517B General Clauses (Apr. 2026).pdf PDF
Exhibit K_ RLP - Broker Project (May 2026).pdf PDF
Exhibit K1_Lease - Broker Project (May 2026).pdf PDF
Exhibit L_ Lease - CA Tax (May 2026).pdf PDF
Exhibit M_DID_Review_Guide.pdf PDF
Exhibit A_2026.6.16_L100.pdf PDF
Exhibit B_3516 Solicitation Provisions (Mar. 2026).pdf PDF
Exhibit C_Agency Special Requirements.pdf PDF
Exhibit C2_Adjacency Diagram_v.260616.pdf PDF
Exhibit D Security FSL Level III.pdf PDF
RLP Amendment No 6.pdf PDF
RLP Amendment 5.pdf PDF
RLP Amendment 4.pdf PDF
RLP Amendment 3.pdf PDF
Exhibit D Form 3516 Dec. 2023.pdf PDF
RLP Amendment 2.pdf PDF
Exhibit E Form 3517B Dec. 2023.pdf PDF
RLP Amendment 1.pdf PDF
0CA3254 SB RLP.pdf PDF
Exhibit B III ASR.pdf PDF
Exhibit C Security.pdf PDF
Exhibit D Form 3516.pdf PDF
Exhibit F Form 1364.pdf PDF
Exhibit H Form 12000.pdf PDF
Exhibit I Seismic.pdf PDF
Exhibit B II ASR.pdf PDF
Exhibit E Form 3517.pdf PDF
Exhibit J Wage Determination.pdf PDF
Sensitive Information Notice.pdf PDF
Exhibit A Form L100.pdf PDF
Exhibit B I ASR.pdf PDF
Exhibit G From 1217.pdf PDF
Exhibit K For Ownership.pdf PDF
Exhibit L FAR-24.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Bankruptcy Court, Santa Barbara

Program Room list

June 16, 2026

Area Summary (In Usable SF) Network Equipment Requirements:***

1525 USMS 588

1016 Court Shared Support Space 1,123

1014 Bankruptcy Judge Chambers Suites 1,591

1014 Bankruptcy Judge Courtroom, Associated Spaces 4,115

1042 Visiting Judge Chambers Suites 912

1016 Bankruptcy Clerk 4,890

13,219 USF e) ~120 total drops at 1 Gb/s

f) ~120 total terminations

ROOM LIST

QTY.

NSF Space

Std.

Total NSF

Circ.

Factor

TOT.

USF/ABOA

Space

Type

Floor Finish* Wall Finish Ceiling STC Door Power/

Data

Special

Outlets

Mech/

Plmbg.

Equipm't Long Term - Special Requirements or Planning Info.

COURT SHARED SUPPORT SPACE

Multi-purpose/ Computer Training Room 1 200 200 0.35 270 LVT PT ACT 45 Rated Add CFM Use training or conference rooms in Clerks area

Lactation Room 1 75 75 0.35 101 CPT PT ACT 55 Rated sink mini-refrigerator NIC

IT Work Room/Help Desk 1 150 150 0.35 203 non-static PT ACT (6) double duplex, 3 dedicated circuits

Telecommunications Rooms 1 120 120 0.25 150 non-static PT ACT Plywood all walls

Server Room (may be shared w/Telcom) 1 320 320 0.25 400 non-static&raised floor PT ACT Plywood all walls

CSO Office 1 120 120 0.25 150 CPT PT ACT 40 Rated

USMS Security Screening 1 350 350 0.25 438 LVT PT ACT 45 Rated

Subtotal 1335 1711

BANKRUPTCY JUDGES CHAMBER SUITES

a Judge's Chambers Office 1 400 400 0.2 480 BRCPT/wood base chair rail/wallcoveringACT/DW 55 Rated sep.zone CPT pad, shelving per USCDG. Sep. Zone for off hours

Other: Infrastructure for Speaker interconnect with Courtroom b Judge's Private Toilet 1 56 56 0.2 67 CT CT/PT DW 55 Rated GFI Fixtures Fan Mirror, Light Sconces, Accessories c Vestibule 1 50 50 0.2 60 BRCPT/wood base PT/wallcovering ACT 55 Rated d Reception Area 1 100 100 0.2 120 BRCPT/wood base PT/wallcovering ACT 40 Rated e Coat Closet 1 10 10 0.2 12 BRCPT/wood base PT ACT Shelf and Pole, Additional shelving f Judicial Assistant Work Space 1 120 120 0.2 144 BRCPT/wood base PT/wallcovering ACT 40 Rated g Filing Room 1 60 60 0.2 72 VCT or LVT PT ACT h Printer/Copier/Fax Area 1 60 60 0.2 72 VCT or LVT PT ACT Dedicated outlets for equipment i Storage 1 80 80 0.2 96 VCT or LVT PT ACT

Conference/Reference Room 1 240 240 0.2 288 BRCPT/wood base PT/wallcovering ACT 55 Rated 4 floor outlets Recessed Wall Box for IT/AV/Monitor

Law Clerk Office 1 150 150 0.2 180 BRCPT/wood base PT ACT 45 Rated

Visiting Judges' Chambers Suite 1 760 760 0.2 912 a-i a-i a-i 55 Rated Suite similar to spaces a-j

Subtotal 2,086 2,503

COURTROOM, ASSOC. SPACES and JURY FACILITIES

Courtroom 1 1,800 1800 0.35 2430 CPT/wood base Wood/Fabric/PT ACT/DW 60 Rated

Other: CPT is carpet tile Wallcovering

Soundlock 1 80 80 0.35 108 CPT/wood base Wood/PT DW 60 Rated

Attorney/Witness Room 2 150 300 0.35 405 CPT/wood base PT ACT 60 Rated

d) 2 x Cisco 4000 Series router

a) 1 X 42U rack, floor anchored and grounded

b) 2 X 3000VA UPS (NEMA L5-30P ; 30-amp twist-lock plug)

c) 2 X 48 port Cisco 9300 series switches

Other: BRCPT is broadloom and padding, Crown moldings, Wall covering above chair rail and laminate below.

Other: Accent/Decorative lighting

Other: Sidelight or Vision panel in door

Floor outlets, Cable ways for presentation technology in bench, rails and courtroom well. Speaker system. Virtual judge monitor (requires millwork modifications with lift).

Refer to US Court Design Guide for sample layout of bench, rails and seating. The Court will provide the Courtroom Furniture.

Spectator seating for 60. Finishes include wood and fabric wall panels, wood benches, jury and spectator rails and gates. 2-4" high access flooring in courtroom well area for cable and conduit raceways. Access flooring shall extend under all courtroom components providing cable and conduit access back to the telecom/A/V control racks. Provide vision panels in doors.

Other: 6"x 18" impact-resist glass window for doors into Crtrm. Use

Magistrate Courtroom layout example in the Appendix. This Courtroom will include a jury box.

Size and Quantity Typical Finishes** Systems/Equipmt.*** Other

Coord infrastructure req. with District IT staff.

Supp. AC for telecom and server room may be shared

EXHIBIT C1

LESSOR:______GOVERNMENT:______

Public Waiting Area 1 400 400 0.35 540 CPT/wood base Chair rail/PT/ wallcovering

ACT/DW

Equipment Storage Room 1 100 100 0.35 135 VCT or LVT PT ACT

Exhibits Storage 1 50 50 0.35 68 VCT or LVT PT ACT

Public Toilets 2 56 112 0.35 151 CT PT DW 55 Rated GFI Privacy lock with occupancy indicators

Janitor Closet 1 56 56 0.35 76 CT PT - 40

Mediation Room 1 150 150 0.35 203 CPT PT ACT 55 Rated infrastructure for AV Direct access from Courtroom to judges circulation

Subtotal 3,048 4,115

BANKRUPTCY CLERK

Clerk of Court Visiting Office 1 150 150 0.32 198 CPT PT ACT 40 Rated

Chief Deputy Clerk 1 180 180 0.32 238 CPT PT ACT 40 Rated

Manager 1 180 180 0.32 238 CPT PT ACT 40 Rated

Prof., Admin and Line Positions 1 150 150 0.32 198 CPT PT ACT 40 Rated

Deputy Clerk 5 64 320 0.32 422 CPT PT ACT

Courtroom Deputy 1 150 150 0.32 198 CPT PT ACT 40 Rated

Bulk Storage 1 210 210 0.25 263 VCT or LVT PT ACT

Archival Storage 1 150 150 0.25 188 VCT or LVT PT ACT

Public Scanning & Pay Copier 1 128 128 0.32 169 LVT PT ACT

Queuing Area 1 100 100 0.32 132 LVT PT ACT

Public Cntr./Clerk/Cashier Stations 1 150 150 0.32 198 LVT/CPT (staff side) PT ACT 2-4 "L" shape plam stations/hi-lo cabinets/glass. Sim to A-16

Records Exam/Public Fax/Computer 1 100 100 0.32 132 LVT PT ACT

Evidence Vault 1 80 80 0.32 106 VCT or LVT PT ACT Deck to deck partitions enclose the room

Equipment Storage 1 50 50 0.32 66 VCT or LVT PT ACT

Work Area 1 275 275 0.32 363 CPT or VCT or LVT PT ACT 40 Rated

Medium Volume Copier Area (incl. in work area) 1 80 80 0.32 106 VCT or LVT PT ACT 40 Rated 20A ded. Dedicated Circuits for equipment

Mail Work Area (incl. in work area) 1 40 40 0.32 53 VCT or LVT PT ACT 40 Rated Plam work counters all walls, Mail sorter slots

Printer/Copier/Fax Area (incl. in work area) 1 60 60 0.32 79 VCT or LVT PT ACT 20A ded. Dedicated Circuits for equipment

Safe (incl. in work area) 1 20 20 0.32 26 VCT or LVT PT ACT

Shredder (incl. in work area) 1 25 25 0.32 33 VCT or LVT PT ACT

Supplies (incl. in work area) 1 50 50 0.32 66 VCT or LVT PT ACT

Staff Breakroom 1 200 200 0.32 264 VCT or LVT PT ACT 40 Rated GFI Sink Disposer Kitch. App.NIC, Plam Cabinets, Tile Back splash, solid surface countertops, waterliner for tenant provided refrigerator, dedicated circuits for appliances

Coat Closet 1 20 20 0.32 26 LVT or CPT PT ACT Shelf & Pole

Staff Toilets 2 56 112 0.32 148 CT PT DW 55 Rated GFI Fixtures Fan Mirror, Light feature, Accessories

Inactive Records Storage 45 9 405 0.32 535 VCT or LVT PT ACT

Exhibits Storage Room 1 100 100 0.32 132 VCT or LVT PT ACT

Financial Vault 1 150 150 0.32 198 VCT or LVT PT ACT

Conference Room 1 300 300 0.32 396 CPT PT ACT 55 Rated 4 floor outlets Recessed Wall Box for IT/AV/Monitor

(FAC ID) Room 1 64 64 0.32 84 CPT PT ACT

*rubber base U.O.N. *** see lease for additional requirments

Subtotal 3,724 4,890

USF TOTALS (usable square feet) 10,193 13,219 USF assumed R/U factor (R/U = rentable/usable) 1.15

RSF TOTALS (rentable square feet) 15,202 RSF

Infrastructure for security screening equipment, public directory monitor and

EXHIBIT C1