Temporary Tree and Plant Protection Specification
This is a construction specification document for the Escambia County Area Transit (ECAT) Facility project located at 100 Clarinda Lane in Pensacola, Florida. The specification details temporary tree and plant protection requirements for the new ECAT facility infrastructure project, which includes an Administration Building, Bus Wash, Fuel Depot, and Maintenance Building. The document outlines comprehensive protection measures for existing trees and plants affected by construction activities, including general protection protocols, pruning requirements, and maintenance standards. All protection-zone fencing must be installed before materials or equipment are brought on-site and construction operations begin. Protection-zone fencing shall consist of high-visibility orange plastic construction fencing measuring 48 inches in height, constructed from high-density polyethylene fabric with 2-inch maximum openings, weighing a minimum of 0.4 lb/ft, and supported by galvanized-steel posts spaced no more than 96 inches apart. Individual tree trunk protection requires installation of 2-by-4-inch wood planks arranged around the trunk at maximum 1-inch spacing (minimum three planks per tree), wrapped with 12-gauge wire and secured with no fewer than three steel bands, maintained at a height of 48 inches and remaining in place for no longer than 12 months.
The specification mandates that a qualified arborist direct all plant-protection measures and prepare inspection reports. Protection zones must be maintained free of weeds and trash, with plants hydrated to ensure survival. Prohibited activities within protection zones include storage of construction materials or debris, vehicle parking or movement, foot traffic, erection of temporary structures, water impoundment, excavation, and attachment of signage or wrapping materials to vegetation. Temporary access through protection zones requires written preapproval from the arborist and installation of a root buffer effective against soil compaction. All protection-zone fencing and signage must be maintained in good condition and removed only when construction operations are complete and equipment has been removed from the site.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Escambia County Area Transit Facility
100 Clarinda Lane Pensacola, Florida 32505
Project No. 2613
Architectural Design Group, Inc
TEMPORARY TREE AND PLANT PROTECTION
015639-1
SECTION 01 56 39 - TEMPORARY TREE AND PLANT PROTECTION
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: General protection and pruning of existing trees and plants that are affected by execution of the Work, whether temporary or permanent construction.
B. Related Requirements:
1. Section 015000 "Temporary Facilities and Controls" for temporary controls, utilities, support facilities, temporary site fencing.
2. Section 311000 "Site Clearing" for removing existing trees and shrubs.
1.2 DEFINITIONS
A. Caliper (DBH): Diameter breast height; diameter of a trunk as measured by a diameter tape at a height 54 inches above the ground line.
B. Plant-Protection Zone: Area surrounding individual trees, groups of trees, shrubs, or other vegetation to be protected during construction and indicated on Drawings.
C. Tree-Protection Zone: Area surrounding individual trees or groups of trees to be protected during construction and indicated on Drawings.
D. Vegetation: Trees, shrubs, groundcovers, grass, and other plants.
1.3 ACTION SUBMITTALS
A. Product Data: For the following.
1. Protection-Zone Fencing.
1.4 FIELD CONDITIONS
A. The following practices are prohibited within protection zones:
1. Storage of construction materials, debris, or excavated material.
2. Moving or parking vehicles or equipment.
3. Foot traffic.
4. Erection of sheds or structures.
5. Impoundment of water.
6. Excavation or other digging unless otherwise indicated.
7. Attachment of signs to or wrapping materials around trees or plants unless otherwise indicated.
100 Clarinda Lane
015639-2
PART 2 - PRODUCTS
2.1 MATERIALS
A. Protection-Zone Fencing: Fencing fixed in position and meeting the following requirements.
1. Plastic Protection-Zone Fencing: Plastic construction fencing constructed of high-density extruded and stretched polyethylene fabric with 2-inch maximum opening in pattern and weighing a minimum of 0.4 lb/ft.; remaining flexible from minus 60 to plus 200 deg F; inert to most chemicals and acids; minimum tensile yield strength of 2000 psi and ultimate tensile strength of 2680 psi; secured with plastic bands or galvanized-steel or stainless steel wire ties; and supported by tubular or T-shape galvanized-steel posts spaced not more than 96 inches apart.
a. Height: 48 inches.
b. Color: High-visibility orange, nonfading.
PART 3 - EXECUTION
3.1 TREE PROTECTION
A. Trunk Protection: Protect the trunk of each tree to remain as follows:
1. Install 2-by-4-inch wood planks around trunk at a maximum of 1 inches apart.
Minimum three planks per tree. Wrap wood planks with 12 guage wire to band together with no less than three steel bands stapled to the planks to hold them securely in place.
a. Height: 48 inches.
b. Trunk protection to remain in place no longer than 12 months. If construction exceeds timeframe indicated, inspect trunk protection at six-month intervals and loosen if necessary.
3.2 PROTECTION ZONES
A. Protection-Zone Fencing: Install protection-zone fencing along edges of protection zones before materials or equipment are brought on the site and construction operations begin in a manner that will prevent people from easily entering protected areas. Construct fencing so as not to obstruct safe passage or visibility at vehicle intersections where fencing is located adjacent to pedestrian walkways or in close proximity to street intersections, drives, or other vehicular circulation.
1. Posts: Set or drive posts into ground one-third the total height of the fence without concrete footings. Where a post is located on existing paving or concrete to remain, provide appropriate means of post support acceptable to Landscape Architect.
2. Plastic Fencing: Stretch fabric taut and secure to posts without bows or sags.
B. Maintain protection zones free of weeds and trash.
100 Clarinda Lane
015639-3
C. Maintain hydration of plants to assure plant survival.
D. Maintain protection-zone fencing and signage in good condition as acceptable to Architect and remove when construction operations are complete and equipment has been removed from the site.
1. Do not remove protection-zone fencing, even temporarily, to allow deliveries or equipment access through the protection zone.
2. Temporary access is permitted subject to preapproval in writing by arborist if a root buffer effective against soil compaction is constructed as directed by arborist. Maintain root buffer so long as access is permitted.
3.3 FIELD QUALITY CONTROL
A. Inspections: Engage a qualified arborist to direct plant-protection measures in the vicinity of trees, shrubs, and other vegetation indicated to remain and to prepare inspection reports.
END OF SECTION 015639
| SECTION 01 56 39 - TEMPORARY TREE AND PLANT PROTECTION |
| PART 1 - GENERAL |
| 1.1 SUMMARY |
| A. Section Includes: General protection and pruning of existing trees and plants that are affected by execution of the Work, whether temporary or permanent construction. |
| B. Related Requirements: |
| 1. Section 015000 "Temporary Facilities and Controls" for temporary controls, utilities, support facilities, temporary site fencing. |
| 2. Section 311000 "Site Clearing" for removing existing trees and shrubs. |
| 1.2 DEFINITIONS |
| A. Caliper (DBH): Diameter breast height; diameter of a trunk as measured by a diameter tape at a height 54 inches above the ground line. |
| B. Plant-Protection Zone: Area surrounding individual trees, groups of trees, shrubs, or other vegetation to be protected during construction and indicated on Drawings. |
| C. Tree-Protection Zone: Area surrounding individual trees or groups of trees to be protected during construction and indicated on Drawings. |
| D. Vegetation: Trees, shrubs, groundcovers, grass, and other plants. |
| 1.3 ACTION SUBMITTALS |
| A. Product Data: For the following. |
| 1. Protection-Zone Fencing. |
| 1.4 FIELD CONDITIONS |
| A. The following practices are prohibited within protection zones: |
| 1. Storage of construction materials, debris, or excavated material. |
| 2. Moving or parking vehicles or equipment. |
| 3. Foot traffic. |
| 4. Erection of sheds or structures. |
| 5. Impoundment of water. |
| 6. Excavation or other digging unless otherwise indicated. |
| 7. Attachment of signs to or wrapping materials around trees or plants unless otherwise indicated. |
| PART 2 - PRODUCTS |
| 2.1 MATERIALS |
| A. Protection-Zone Fencing: Fencing fixed in position and meeting the following requirements. |
| 1. Plastic Protection-Zone Fencing: Plastic construction fencing constructed of high-density extruded and stretched polyethylene fabric with 2-inch maximum opening in pattern and weighing a minimum of 0.4 lb/ft.; remaining flexible from minus 60 to pl... |
| a. Height: 48 inches. |
| b. Color: High-visibility orange, nonfading. |
| PART 3 - EXECUTION |
| 3.1 TREE PROTECTION |
| A. Trunk Protection: Protect the trunk of each tree to remain as follows: |
| 1. Install 2-by-4-inch wood planks around trunk at a maximum of 1 inches apart. Minimum three planks per tree. Wrap wood planks with 12 guage wire to band together with no less than three steel bands stapled to the planks to hold them securely in place. |
| a. Height: 48 inches. |
| b. Trunk protection to remain in place no longer than 12 months. If construction exceeds timeframe indicated, inspect trunk protection at six-month intervals and loosen if necessary. |
| 3.2 PROTECTION ZONES |
| A. Protection-Zone Fencing: Install protection-zone fencing along edges of protection zones before materials or equipment are brought on the site and construction operations begin in a manner that will prevent people from easily entering protected are... |
| 1. Posts: Set or drive posts into ground one-third the total height of the fence without concrete footings. Where a post is located on existing paving or concrete to remain, provide appropriate means of post support acceptable to Landscape Architect. |
| 2. Plastic Fencing: Stretch fabric taut and secure to posts without bows or sags. |
| B. Maintain protection zones free of weeds and trash. |
| C. Maintain hydration of plants to assure plant survival. |
| D. Maintain protection-zone fencing and signage in good condition as acceptable to Architect and remove when construction operations are complete and equipment has been removed from the site. |
| 1. Do not remove protection-zone fencing, even temporarily, to allow deliveries or equipment access through the protection zone. |
| 2. Temporary access is permitted subject to preapproval in writing by arborist if a root buffer effective against soil compaction is constructed as directed by arborist. Maintain root buffer so long as access is permitted. |
| 3.3 FIELD QUALITY CONTROL |
| A. Inspections: Engage a qualified arborist to direct plant-protection measures in the vicinity of trees, shrubs, and other vegetation indicated to remain and to prepare inspection reports. |