This diagram depicts a second floor supply riser for Building 2 at the New Orleans VA Medical Center. Key details include:
-
The diagram shows the layout of domestic hot water, domestic cold water, and sanitary piping serving various plumbing fixtures on the second floor, including floor drains, sinks, and an electronic automatic trap primer cabinet. Pipe sizes range from 1/2 inch to 4 inches in diameter.
-
The related federal contract opportunity is a solicitation to provide site preparation for a dual energy CT scanner. The solicitation number is 629-22-135 issued by the Department of Veterans Affairs Veterans Health Administration VISN 16. The opportunity details are included in an attached RFP document.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(2)1/2"TP UP TO
AUTOMATIC TRAP
PRIMER CABINET
(3RD FLOOR)
ELECTRONIC AUTOMATIC
TRAP PRIMER CABINET
1 1/2"DCW DROP
1/2"TP DN
TO FLOOR DRAINS
1/2"TP TO
FLOOR DRAINS
(3RD FLOOR)
P-804
1/2"TP TO
FLOOR DRAINS
(3RD FLOOR)
P-804
2E159 P-414
2E159A P-414 P-104A
2E158 P-414
2E165 P-414
2E157 P-414
2E156 P-414
2E155 P-414
2E147 P-414
2E146 P-414
2E145 P-414
2E144 P-414
2E140 P-414
2E148 P-414 P-104A
2E150 P-414
2E178 P-414
2E167 P-414
2E166 P-414
2E167A P-414
P-104A
2E168 P-414 P-104A
2E169 P-414
P-104A P-701
2E164 P-528
2E170 P-504
2E152D P-414
2E154 P-414
2E152A P-414
2F105 P-414
2F106 P-414
P-104A
2F104 P-414
2F107 P-414
P-104A
2F103 P-414
2F108 P-414
P-104A
2F102 P-414
2F109 P-414
P-104A
2F110 P-414
P-104A
2E136 P-414 P-519A
2E136 P-414
2E138 P-504
2E126 P-414 P-104A2E129
P-414
2E125 P-414 P-104A
2E124 P-414 P-104A
2E120 P-414 P-104A
2E130 P-414
2E132 P-414
2E104 P-504
2E108 P-414
2E110 P-414
2E114 P-414
2E127 P-414
2" DHWL
2" DHWL
1" DHWRL
1" DHWL
3" DCWL
3/4" DHWL
3" DCWL
1" DCWL
3/4" DCWL
1 1/4" DHWL
1 1/4" DHWL
2 1/2" DCWL
1" DHWL
1 1/4" DHWL
3/4" DCWL
1 1/2" DCWL
1" DHWL
1" DHWL
1 1/4" DCWL
1 1/4" DHWL
1" DHWL
3/4" DCWL
1 1/4" DHWL
3" DCWL
2" DCWL
1 1/4" DHWL
3" DCWL
1 1/2" DHWL
1 1/2" DCWL
3/4" DCWL
1/2" DCWL
1 1/4" DHWL
1 1/2" DHWL
2" DHWL
2" DHWL
2" DHWL
1/2" DCWL
2" DHWL
ELECTRONIC AUTOMATIC
TRAP PRIMER CABINET
1 1/2"DCW DROP
1/2"TP DN
TO FLOOR DRAINS
ELECTRONIC AUTOMATIC
TRAP PRIMER CABINET
1 1/2"DCW DROP
1/2"TP DN
TO FLOOR DRAINS
P-804
2F101B P-414
P-104A
2F101A P-414
P-104A
1 1/2"DHWL DN
3"DCWL DN
2 1/2"DHWL DN
4"DCWL DN
P-706
1" DHWL
3" DCWL
1" DHWL
1" DCWL
2" DCWL
1/2" DHWL
1 1/4" DHWL
1 1/4" DHWL
1 1/4" DHWL
2" DCWL
P-712
SL
1B
SL
1B
1-1/2"RPBP
FOR HVAC
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
2PL701-E
BLDG 2 SECOND FLOOR SUPPLY RISER DIAGRAM
AREA E
RVD CADDFebruary 29, 2012
02629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING/ PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_08
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
N.T.S.
BLDG 2 2ND FLOOR SUPPLY RISER
DIAGRAM AREA E
BUILDING #2 FLOOR ELEVATIONS:
UPPER ROOF(SEVENTH FLOOR): 214'-0"
ROOF(SIXTH FLOOR): 195'-0"
FIFTH FLOOR: 176'-0"
FOURTH FLOOR: 157'-0"
THIRD FLOOR: 138'-0"
SECOND FLOOR: 119'-0"
FIRST FLOOR: 100'-0"
GENERAL NOTES
1. PROVIDE ISOLATION VALVES FOR ALL BRANCH LINE PIPING.
BUILDING #2 FLOOR ELEVATIONS:
UPPER ROOF(SEVENTH FLOOR): 214'-0"
ROOF(SIXTH FLOOR): 195'-0"
FIFTH FLOOR: 176'-0"
FOURTH FLOOR: 157'-0"
THIRD FLOOR: 138'-0"
SECOND FLOOR: 119'-0"
FIRST FLOOR: 100'-0"
GENERAL NOTES
1. PROVIDE ISOLATION VALVES FOR ALL BRANCH LINE PIPING.
2. PROVIDE WATER ARRESTORS AT ALL SOLENOID VALVES, AT ALL
GROUPS OF TWO OR MORE FLUSH VALVES, AT ALL QUICK OPENING
OR CLOSING VALVES, AT ALL MEDICAL EQUIPMENT AND AT ALL
KITCHEN EQUIPMENT
File details come from the government source that posted it. Updated .