0073-2SB101-E Floor Plan.pdf

PDF 397 KB Posted

Attached to
Z2DZ--Design Build Project 629-22-135 Site Prep For Dual Energy CT - 36C25622R0075
Solicitation number
629-22-135
Issued by

About this file

This document contains a floor plan drawing and details for a federal construction project along with information on a related federal contract opportunity. The floor plan drawing provides layout details for a first floor area including dimensions, notes, and references to other drawings. The related federal contract opportunity is a solicitation for a design-build project for site preparation work for a dual energy CT scanner. The solicitation is seeking proposals for work including site preparation, excavation, installation of utilities and slabs, and other tasks to ready the site for the CT scanner. Proposals are due by the date listed on the attached RFP. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16.

View the file

Other files

Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

E

E

F

F

G

G

D

D

C

C

B

XA

H

F.9

F.9

A.5

AA

5.3

5.3

AA.2

8.3

8.1

E.6

E.3

1" E

XP

. J

T.

13' � 8" 11' � 0"

7.6

6.1

10' � 2" 22' � 10" 33' � 0" 33' � 0" 33' � 0" 33' � 0" 17' � 6" 15' � 6" 8' � 4" 24' � 8"

23' � 10" 10' � 2" 22' � 10" 9' � 11" 12' � 0" 11' � 1" 23' � 0" 10' � 0" 33' � 0"

( 98' � 9" ) ( 98' � 9" )

( 98' � 9" )

98' � 9"

( 9 6'

1"

P44

"96' � 1"

P44

P44

P44

P44

96' � 1"

0SB501

0SB501

0SB501

#6@9" O.C. EA. WAY TOP

#5@12" O.C. EA WAY BOT

2SF201

1' � 0" 1' � 11"

FG

ES

4" 10' � 10" 1' � 11"

ES FG

CC

ES

FG

3' � 0" 1' � 11"

7 1/2"

1' � 1 1/2"

1' � 6" 3"

9"

1' � 6"

9"

1' � 9" 1' � 9"

TYP. U.N.O

FW

FG

FW

FG

CC

1' � 7 1/2"

3' � 11"

ES

FG

CC

2' � 10"FG ES

CC

ES FG

21' � 5 3/4"

2" 2' � 10"

3' � 10"

9"

9"

1' � 6" 9"

ES

ES

CC

CC

FG

10" 5' � 0"

10"

" 4

10" 5' � 0"

10"

EQEQ 4"

E Q

E Q

4' � 0"

VP

#6@9" O.C. EA. WAY TOP, TYP

#5@12" O.C. EA WAY BOT, TYP

#6@9" O.C. x 4'�0"+HK TOP

TYP AT ALL DISCONT. SLAB EDGES

#6@9" O.C. EA. WAY TOP, TYP

#5@12" O.C. EA WAY BOT, TYP

#6@9" O.C. x 4'�0"+HK TOP

TYP AT ALL DISCONT.

SLAB EDGES

2' � 0"

�G

B

�G

B

�G

B

�G

B

�G

B

�G

B

2�GB01 2�GB01 2�GB01 2�GB05 2�GB06 2�GB08 2�GB08 2�GB08 2�GB08

2�GB03 2�GB04

2�GB03 2�GB04

�G

B

�G

B

�G

B

�G

B

�G

B

�G

B

2�GB01 2�GB01 2�GB01 2�GB01 2�GB01

�G

B

�G

B

2�GB01 2�GB01

2�GB01

2�GB07

D.3

8.7

8.5

/1

( 98' � 9" )

( 98' � 9" )

9"9"

( 98' � 9" )

2' � 11" 9' � 1 1/2"

T.O.S. = 99' � 4"

0SB502

0SB502

( 98' � 9" )

( 98' � 9" )

( 98' � 9" )

( 99' � 9" )

( 98' � 9" )

( 99' � 9" )

( 98' � 9" )

T Y

P U

.N .O

1' � 9" (TYP.)1' � 9" (TYP.)

( 98' � 9" )

P

LA

N

TE

R

P

LA

N

TE

R

P

LA

N

TE

R

2�GB05

( 98' � 9" )

#4@12"

(TOP & BOT.)

TYP. IN AREAS

AROUND PLANTERS

(T O

P

(B O

T

T Y

P

IN

A R

E A

S A

R O

U N

D P

L A

N T

E R

S

18' � 7" 24' � 6 1/2" 18' � 7" 26' � 2" 18' � 7" 18' � 4 7/8"

ES

ES

ES

ES

ES

ES

2' � 6"

2' � 7 1/2" 15' � 1" 26' � 1"

6' � 11" 26' � 1" 6' � 11" 15' � 3 1/2"

2�GB07

/2

/2

SIM.

0SB501

4' � 2"

1' � 2"

4"

11 1/2"

5.6

2�GB062�GB05 2�GB05 2�GB06 2�GB05 2�GB05 2�GB06 2�GB05 2�GB06

2�GB052�GB062�GB05 2�GB06 2�GB06 2�GB06 2�GB06 2�GB06 2�GB06 2�GB06

�G

B

�G

B

2SB501

1 1 1 1 1

SIM

1 1

2SB501

SIM.

2SB501

SIM.

2SB501

6' � 0"

0SB501

P

P36

P

Y20

CC

CC

CC

3 3

CC

( 1

2N�PC11

( 1 34' �

4" )

AA.07

1' � 8 1/2"

8"

/2

/4

1' � 8 1/2"

0SB501

2' � 2 3/4"

8"

2 1/2"

/2

6' � 1 1/4" 1

/2 " 2 1/2"

0SB501

0SB501

0SB501

"10' � 9 1/2" 6' � 11"

0SB501

SIM.

12' � 4 1/4"

8"

8 8

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

B3

PLAN

NORTH

B

A

D

C

E

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H A L

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

E E T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

X T

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE

APPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBER

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

BLDG 2 FIRST FLOOR FRAMING PLAN - AREA E

TMD IJPJuly 15, 2011

SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

I.S.C. GROUP, INC. / IRRIGATION

DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE

FULLY SPRINKLERED

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

COMMUNICATIONS DESIGN GROUP / LOW VOLTAGE

2SB101-E

2629-HS2-401

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_5

1/8" = 1'�0"1

BLDG 2 FIRST FLOOR FRAMING

PLAN � AREA E

S

B �D

S

B �E

S

B �E

S

B �F

2SB101�D3

2SB101�F

S

B �D

S

B �D

2SB101�E

2SB101�F

1SB101�C1

2SB101�A.3

S

B �F

S

B �A

.3

S

B �E

S

B �C

S

B �D

S

B �C

2SB101�D

2SB101�E

ALL FOUNDATION DRAWINGS WITH SB PREFIX IN EWP04 WERE REPLACED

BY THE SHEETS OF THE SAME NAME AND NUMBER FROM EWP05 EFFECTIVE

WITH ADDENDUM #5 TO EWP04.

1 ADDENDUM 1 8/24/11

2 ADDENDUM 2 8/24/11

3 ADDENDUM 3 � POST BID 12/2/11

8 BULLETIN 009B 11/27/12

SEE RFI 01408 FOR

TOP OF PIER

CLARIFICATIONS.

-5

/8

Step in curb not needed

RFI 1916

1'-9 1/8"

100'-2"

RFI 1916

Step in curb not needed

RFI 1916

RFI 1916 Curb Clarification at Courtyard

7'-11 3/4"

14'-4 1/4"

RFI 1948 Curb Clarifications

'-8

/8

'-1

/4

11'-7 1/4"

'-8

/8

'-1

/4

10'-11" 7'-11 3/4"

10-'11" 7'-11 3/4"13'-11 1/2"7'-11 3/4"

7'-11 3/4"

4'-3 3/4" 1'-1 3/4"

RFI 1948: See detail provided with RFI 1499

'-1

'-1

'-1

'-4

TOC 100'-3"TOC 100'-3"

TOC 100'-3"

TOC 100'-3"

RFI 04326: Planters per EWP08 Drawings

File details come from the government source that posted it. Updated .