02 USAID - Nampula _ BASE (LOT1) - Pecas Desenhadas - Parte 1.pdf
PDF 24 MB Posted
- Solicitation number
- 72065624R00001
About this file
This solicitation is for construction services to build or rehabilitate up to 10 health facilities across Nampula and Cabo Delgado provinces in Mozambique. The US Agency for International Development Mozambique seeks qualified locally registered construction firms with experience working in northern Mozambique to construct new maternity blocks or rehabilitate existing structures based on scope of work and drawings provided. The selected firm(s) will be responsible for all labor, materials, tools and equipment necessary for construction including installation of solar power systems, water supply via borehole or grid, septic systems, and rainwater collection tanks. Training of local health facility staff on operation and maintenance of electrical and water systems is also required after handover of completed facilities. A one-year warranty is required beginning from project completion date.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B A S E ( L O T 1 ) | C L I N s
Construção e Reabilitação de Centros de Saúde na província de Nampula Fornecimento de mão de obra, equipamento, material, ferramentas e todos os meios necessários para a Construção e Reabilitação dos Centros de Saúde, de acordo com o projecto fornecido pela USAID.
Fevereiro 2024
CONSULTEC – Consultores Associados, Lda.
Rua Tenente General Oswaldo Tazama, 169 Tel.: (+258 – 21) 491 583 – 491 555 Telemóvel: (+258) 82 3044240 Fax: (+258 – 21) 491 578 E-mail: consultec@consultec.co.mz
MAPUTO – MOÇAMBIQUE
Preparado por: Preparado para:
I . C O N S T R U Ç Ã O D E U M A N O V A M A T E R N I D A D E
I I . R E A B I L I T A Ç Ã O D O B L O C O D A M A T E R N I D A D E
CLIN 1.1.1
Centro de Saúde de Odinepa
CLIN 1.1.2
Centro de Saúde de Quinga
CLIN 1.1.3
Centro de Saúde de Ontupaia
Índice
Distrito de Erati Coordenadas: -13.600284, 40.027332
I I I . E D I F Í C I O S D E A P O I O
Cozinha.
Lavandaria.
Lixo Hospitalar.
Sanitário Externo.
Distrito de Liupo Coordenadas: 15°49'29"S 40°13'26"E
Distrito de Nacala Porto Coordenadas: -14.595278, 40.689167
Fevereiro 2024
I. Construção de uma Nova Maternidade
Implantação e Planta de Novas Construções:
Metocheria; Mazua; Mirepe; Namaponda.
Peças Desenhadas - Maternidade Tipo.
Consultores Associados, Lda.
GSPublisherVersion 0.0.100.100
C20-28 | Projecto Executivo Maternidade Tipo | Rev.00
Arquitectura.
Outubro 2023
CONSULTEC –
Tel.: (+258 –
E-
MAPUTO –
Consultores Associados, Lda.
Rua Tenente General Oswaldo Tazama, 169
21) 491 583 – 491 555
Telemóvel: (+258) 82 3044240 Fax: (+258 – 21) 491 578 mail: consultec@consultec.co.mz
MOÇAMBIQUE
"Construíndo o Futuro com Responsabilidade" | "Building the future Responsibly"
Serviços de Consultoria (Projecto Executivo e Fiscalização), para melhoria de infraestruturas de Saúde na província de Nampula, Moçambique.
Fevereiro 2024
"Construíndo o Futuro com Responsabilidade" | "Building the future Responsibly"
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
C20-28
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº| Nr Sheet
No. Projecto | Project Nr:
0020/04/23
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
CENTRO DE SAÚDE DE ODINEPA
OMVS VS BA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente:
Projecto Executivo|Detailed Design
Arquitectura|Architecture
Revisão| Revision:
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
07/23VS OMFor Approval VS BA
Descrição|Descrip on
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
N US.ONTUPAIA II.Pln
C-20-28-ARQ-R-MAT-D-C20-28-MAT-01.1
ODINEPA
PLANTA DE LOCALIZAÇÃO
C20-28-MAT-01.11:1, 1:10.23,
1:6.93
GSPublisherVersion 0.0.100.100
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
C20-28
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº| Nr Sheet
No. Projecto | Project Nr:
0020/04/23
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
ONTUPAIA HEALTH CENTER
OMCA CA BA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente:
Projecto Executivo|Detailed Design
Arquitectura|Architecture
Revisão| Revision:
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
10/07/23CA OMFor Approval CA BA
Descrição|Descrip on
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
N US.ONTUPAIA II.Pln
C-20-28-ARQ-R-MAT-D-A.01.0
EXISTING CONSTRUCTION
GENERAL SITE PLAN
A.01.0
MAP - MOZAMBIQUE / NAMPULA PROVINCE NAMPULA PROVINCE / NACALA PORTO DISTRICT
SITE PLAN - US. ONTUPAIA SITE PLAN - US. ONTUPAIA
MAIN ACCESS
EXTERNAL SERVICE
MATERNITY REAR ACCESS
SANITARYPAV.
WASTE FACILITY
MAP - MOZAMBIQUE / NAMPULA PROVINCE NAMPULA PROVINCE / NACALA PORTO DISTRICT
SITE PLAN - US. ONTUPAIA SITE PLAN - US. ONTUPAIA
MAIN ACCESS
EXTERNAL SERVICE
MATERNITY REAR ACCESS
SANITARYPAV.
WASTE FACILITY
MAIN ACCESS
MATERNITY
BUILDING
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
C20-28
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº| Nr Sheet
No. Projecto | Project Nr:
0020/04/23
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
CENTRO DE SAÚDE DE ODINEPA
OMVS VS BA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente:
Projecto Executivo|Detailed Design
Arquitectura|Architecture
Revisão| Revision:
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
07/23VS OMFor Approval VS BA
Descrição|Descrip on
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
N US.ONTUPAIA II.Pln
C-20-28-ARQ-R-MAT-D-C20-28-MAT-01.2
ODINEPA
PLANTA DE IMPLANTAÇÃO
C20-28-MAT-01.21:1, 1:350
MATERNITY - ODINEPA SITE PLAN 1:350
BLOCO DA MATERNIDADE
EXISTENTE
LEGENDA
NOVO BLOCO DA
MATERNIDADE
COZINHA
4 LAVANDARIA
SANITÁRIOS EXTERIORES
LIXO HOSPITALAR
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
CONSULTEC
Consultores Associados, Lda
CONSULTEC
Consultores Associados, Lda
GSPublisherVersion 0.0.100.100
2 3 4 5 61 7 8 9 10 11 12
2 3 4 5 61 7 8 9 10 11
B
C
D
A
E
F
G
H
B
C
D
A
E
F
G
H
No. de Desenho |Nr. DWG Descrição|Descrip on
Notas | Notes:
Data | DateRev. Descrição|Descrip on
No. Projecto | Project Nr:
REVISÕES DO PROJECTO|PROJECT REVIEWS
Especialidade | Discipline:
OJ OJ01 BA OMC20-28
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
A2
Fase do Projecto | Project Phase :
Eng º Orlando Mavie
Revisão| Revision:Data | Date: Escala | Scale: Formato | Format: Folha nº| Nr Sheet:
Coordenador do Projecto | Project Manager
OJ OJ BA OM
Ficheiro|File:
No. DWG:
Nr. DWG Cliente|Client DWG No.:
Projecto Executivo|Detailed Design
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
For Approval
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
Arquitectura|Architecture
Health Center.Pln
C-20-28-ARQ-N-ED-D-C20-28-HW-01
02/24
1:100, 1:35002/24
MATERNIDADE TIPO | MATERNITY MODEL DESIGN
C20-28-GEN-DRW-03
DESENHOS GERAIS
PLANTA DE COBERTURA GERAL
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
Caleira em betão
Caleira em betão
Linha da cobertura
Linha de Cobertura
1 2
1 2 3
Rampa i = 6 %
Sala de Parto A: 24.59 m2
Copa A: 4.43 m2
Expurgo A: 2.97 m2
Sala de Admissão/Pré-natal A: 8.51 m2
Sala de Pródromos A: 6.57 m2
Sala Pós-Parto A: 34.08 m2
Sanitário Inclusivo A: 6.37 m2
Sala de Observação A: 7.67 m2
RCP Recém-Nascidos A: 5.11 m2
Armazém A: 2.70 m2
Mãe Canguru A: 9.88 m2
Zona de Espera A: 5.80 m2
Armazém A: 3.23 m2
WC Staff A: 4.37 m2
Sanitário Inclusivo A: 5.80 m2
Sala de Baterias A: 3.02 m2
MAT - Circulação A: 13.97 m2
MAT - Circulação A: 2.91 m2
PBT-Corredor A: 11.75 m2
Zona de Espera A: 8.33 m2
PRÉ-NATAL
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO
APOIADO
2500 Litros
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
N
Área Coberta - Maternidade Cobertura 1 - Maternidade:
Cobertura 2 - Pré-Natal:
189.56 m2
106.42 m2
Planta Geral da Maternidade
Ax Bx Cx Dx Ex Hx
1x
2x
3x
Jx Cx Nx
6x
10x
8x
11x
Dx
4x
Fx Gx
LxIx
9x
7x
5x
4x
12x
Kx MxA= A´
A=
A´
B=B´´ B=B´´
C=C´´ C=C´´
D=D D=D
Reservatório elevado
Escada metálica
Cobertura Inclinada em Betão com Inclinação de 5%
Caleira em betão
Caleira em betão
Cobertura 1 Laje de Betão Armado 120mm
Cobertura 2 Laje de Betão Armado 120mm
MAT PLANTA DE COBERTURA 1:100
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
CONSULTEC
Consultores Associados, Lda
CONSULTEC
Consultores Associados, Lda
GSPublisherVersion 0.0.100.100
2 3 4 5 61 7 8 9 10 11 12
2 3 4 5 61 7 8 9 10 11
B
C
D
A
E
F
G
H
B
C
D
A
E
F
G
H
No. de Desenho |Nr. DWG Descrição|Descrip on
Notas | Notes:
Data | DateRev. Descrição|Descrip on
No. Projecto | Project Nr:
REVISÕES DO PROJECTO|PROJECT REVIEWS
Especialidade | Discipline:
OJ OJ01 BA OMC20-28
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
A2
Fase do Projecto | Project Phase :
Eng º Orlando Mavie
Revisão| Revision:Data | Date: Escala | Scale: Formato | Format: Folha nº| Nr Sheet:
Coordenador do Projecto | Project Manager
OJ OJ BA OM
Ficheiro|File:
No. DWG:
Nr. DWG Cliente|Client DWG No.:
Projecto Executivo|Detailed Design
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
For Approval
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
Arquitectura|Architecture
Health Center.Pln
C-20-28-ARQ-N-ED-D-C20-28-HW-01
02/24
1:100, 1:35002/24
MATERNIDADE TIPO | MATERNITY MODEL DESIGN
C20-28-GEN-DRW-04
DESENHOS GERAIS
PLANTA GERAL DA MATERNIDADE
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
Caleira em betão
Caleira em betão
Linha da cobertura
Linha de Cobertura
1 2
1 2 3
Rampa i = 6 %
Sala de Parto A: 24.59 m2
Copa A: 4.43 m2
Expurgo A: 2.97 m2
Sala de Admissão/Pré-natal A: 8.51 m2
Sala de Pródromos A: 6.57 m2
Sala Pós-Parto A: 34.08 m2
Sanitário Inclusivo A: 6.37 m2
Sala de Observação A: 7.67 m2
RCP Recém-Nascidos A: 5.11 m2
Armazém A: 2.70 m2
Mãe Canguru A: 9.88 m2
Zona de Espera A: 5.80 m2
Armazém A: 3.23 m2
WC Staff A: 4.37 m2
Sanitário Inclusivo A: 5.80 m2
Sala de Baterias A: 3.02 m2
MAT - Circulação A: 13.97 m2
MAT - Circulação A: 2.91 m2
PBT-Corredor A: 11.75 m2
Zona de Espera A: 8.33 m2
PRÉ-NATAL
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO
APOIADO
2500 Litros
C20-28-GEN PLANTA GERAL DA MATERNIDADE 1:100
Planta Geral da Maternidade
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
CONSULTEC
Consultores Associados, Lda
CONSULTEC
Consultores Associados, Lda
GSPublisherVersion 0.0.100.100
2 3 4 5 61 7 8 9 10 11 12
2 3 4 5 61 7 8 9 10 11
B
C
D
A
E
F
G
H
B
C
D
A
E
F
G
H
No. de Desenho |Nr. DWG Descrição|Descrip on
Notas | Notes:
Data | DateRev. Descrição|Descrip on
No. Projecto | Project Nr:
REVISÕES DO PROJECTO|PROJECT REVIEWS
Especialidade | Discipline:
OJ OJ01 BA OMC20-28
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
A2
Fase do Projecto | Project Phase :
Eng º Orlando Mavie
Revisão| Revision:Data | Date: Escala | Scale: Formato | Format: Folha nº| Nr Sheet:
Coordenador do Projecto | Project Manager
OJ OJ BA OM
Ficheiro|File:
No. DWG:
Nr. DWG Cliente|Client DWG No.:
Projecto Executivo|Detailed Design
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
For Approval
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
Arquitectura|Architecture
Health Center.Pln
C-20-28-ARQ-N-ED-D-C20-28-HW-01
02/24
1:100, 1:35002/24
MATERNIDADE TIPO | MATERNITY MODEL DESIGN
C20-28-GEN-DRW-06
DESENHOS GERAIS
PLANTA GERAL COTADA
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
Ax Bx Cx Dx Ex Hx
1x
2x
3x
Jx Cx Nx
6x
10x
8x
11x
Dx
4x
Fx Gx
Lx
Ramp i = 6.00 %
Ramp i = 6.00 %
Ix
9x
7x
5x
4x
12x
Kx Mx
Rampa i = 6 %
Caleira em betão
Caleira em betão
Linha da cobertura
Linha de Cobertura
1 2
1 2 3
Rampa i = 6 %
Sala de Parto A: 24.59 m2
Copa A: 4.43 m2
Expurgo A: 2.97 m2
Sala de Admissão/Pré-natal A: 8.51 m2
Sala de Pródromos A: 6.57 m2
Sala Pós-Parto A: 34.08 m2
Sanitário Inclusivo A: 6.37 m2
Sala de Observação A: 7.67 m2
RCP Recém-Nascidos A: 5.11 m2
Armazém A: 2.70 m2
Mãe Canguru A: 9.88 m2
Zona de Espera A: 5.80 m2
Armazém A: 3.23 m2
WC Staff A: 4.37 m2
Sanitário Inclusivo A: 5.80 m2
Sala de Baterias A: 3.02 m2
MAT - Circulação A: 13.97 m2
MAT - Circulação A: 2.91 m2
PBT-Corredor A: 11.75 m2
Zona de Espera A: 8.33 m2
3.60 2.00 1.50 1.50 2.30 1.80 5.00
2.
1.
3.
7.
0.
1.
2.
1.
1.
2.
2.
8.
1.
2.40 1.70 1.87 0.23
1.20 1.50 3.00
11.90
4.
.1
.9
18.00
1.01 11.90 10.43 23.34
4.
.3
.5
8.51 12.12 0.60 2.11
2.69 17.94 2.71
23.23
0.
1.
2.
1.
1.
2.
PRÉ-NATAL
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO
APOIADO
2500 Litros
80X120
A= A´
A=
A´
B=B´´ B=B´´
C=C´´ C=C´´
D=D D=D
N
C20-28-GEN PLANTA GERAL COTADA 1:100
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
CONSULTEC
Consultores Associados, Lda
CONSULTEC
Consultores Associados, Lda
GSPublisherVersion 0.0.100.100
2 3 4 5 61 7 8 9 10 11 12
2 3 4 5 61 7 8 9 10 11
B
C
D
A
E
F
G
H
B
C
D
A
E
F
G
H
No. de Desenho |Nr. DWG Descrição|Descrip on
Notas | Notes:
Data | DateRev. Descrição|Descrip on
No. Projecto | Project Nr:
REVISÕES DO PROJECTO|PROJECT REVIEWS
Especialidade | Discipline:
OJ OJ01 BA OMC20-28
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
A2
Fase do Projecto | Project Phase :
Eng º Orlando Mavie
Revisão| Revision:Data | Date: Escala | Scale: Formato | Format: Folha nº| Nr Sheet:
Coordenador do Projecto | Project Manager
OJ OJ BA OM
Ficheiro|File:
No. DWG:
Nr. DWG Cliente|Client DWG No.:
Projecto Executivo|Detailed Design
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
For Approval
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
Arquitectura|Architecture
Health Center.Pln
C-20-28-ARQ-N-ED-D-C20-28-HW-01
02/24
1:100, 1:65002/24
MATERNIDADE TIPO | MATERNITY MODEL DESIGN
C20-28-GEN-DRW-07
DESENHOS GERAIS
ALÇADOS GERAIS
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
Caleira em betão
Caleira em betão
Linha da cobertura
Linha de Cobertura
1 2
1 2 3
Rampa i = 6 %
Sala de Parto A: 24.59 m2
Copa A: 4.43 m2
Expurgo A: 2.97 m2
Sala de Admissão/Pré-natal A: 8.51 m2
Sala de Pródromos A: 6.57 m2
Sala Pós-Parto A: 34.08 m2
Sanitário Inclusivo A: 6.37 m2
Sala de Observação A: 7.67 m2
RCP Recém-Nascidos A: 5.11 m2
Armazém A: 2.70 m2
Mãe Canguru A: 9.88 m2
Zona de Espera A: 5.80 m2
Armazém A: 3.23 m2
WC Staff A: 4.37 m2
Sanitário Inclusivo A: 5.80 m2
Sala de Baterias A: 3.02 m2
MAT - Circulação A: 13.97 m2
MAT - Circulação A: 2.91 m2
PBT-Corredor A: 11.75 m2
Zona de Espera A: 8.33 m2
PRÉ-NATAL
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO
APOIADO
2500 Litros
-0.45
+1.05
+2.70
+3.92
0.89 1.82 0.61 0.87 0.82 1.30 0.57 0.12
0.11 1.19 0.00 0.00 1.48 0.03 1.40 0.10 1.48 0.82 1.81 1.56 3.43 0.77 0.65 1.29
-0.45
+0.85
+2.66
+3.44
+5.13
+7.05
1.92 1.79 0.48 2.52 1.60 0.08 2.72 1.44 0.04 2.23 1.69 0.27 0.54 0.88 0.52 1.80 1.79 0.40
-0.40
+1.05
+2.66
+3.44
+3.93
1.29 0.65 0.77 3.43 1.56 1.81 0.82 1.48 0.10 1.40 0.03 1.48 0.00 0.00 1.19 0.11 0.12
0.57 1.30 0.82 0.87 0.61 1.82 0.89
-0.45
+0.90
+2.35
+3.92
-0.45
+1.05
+3.44
+5.13
+7.05
0.40 1.79 1.80 0.52 0.88 0.54 0.27 1.69 2.23 0.04 1.44 2.72 0.08 1.60 2.52 0.48 1.79 1.92
C20-28-GEN ALÇADO FRONTAL 1:100 C20-28-GEN ALÇADO LATERAL ESQUERDO 1:100
C20-28-GEN ALÇADO POSTERIOR 1:100 C20-28-GEN ALÇADO LATERAL DIREITO 1:100
C20-28
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-MAT-02
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:100, 1:350
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-MAT-02
A
B
C
D
E
F
BLOCO DA MATERNIDADE
PLANTA DA COBERTURA
Ramp i = 6.00 %Rampa i = 6 %
Caleira em betão
Caleira em betão
Linha de Cobertura
1 2
Sala de Parto A: 24.59 m2
Copa A: 4.43 m2
Expurgo A: 2.97 m2
Sala de Pródromos A: 6.57 m2
Sala Pós-Parto A: 34.08 m2
Sala de Observação A: 7.67 m2
RCP Recém-Nascidos A: 5.11 m2
Mãe Canguru A: 9.88 m2
Armazém A: 3.23 m2
WC Staff A: 4.37 m2
Sanitário Inclusivo A: 5.80 m2
MAT - Circulação A: 13.97 m2
MAT - Circulação A: 2.91 m2
Zona de Espera A: 8.33 m2
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO
APOIADO
2500 Litros
A= A´
B=B´´ B=B´´
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
Planta Geral da Maternidade
Área Coberta - Maternidade Cobertura 1 - Maternidade: 189.56 m2
Ax Bx Cx Dx Ex Hx
1x
2x
3x
11x
4x
Fx Gx
12x
A= A´
B=B´´ B=B´´ Reservatório elevado
Escada metálica
Cobertura Inclinada em Betão com Inclinação de 5%
Caleira em betão
Caleira em betão
Cobertura 1
MAT PLANTA DE COBERTURA 1:100
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-MAT-03
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:100, 1:350
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-MAT-03
A
B
C
D
E
F
BLOCO DA MATERNIDADE
PLANTA DE PISO TÉRREO
Ramp i = 6.00 %Rampa i = 6 %
Caleira em betão
Caleira em betão
Linha de Cobertura
1 2
Sala de Parto A: 24.59 m2
Expurgo A: 2.97 m2
Sala Pós-Parto A: 34.08 m2
Sala de Observação A: 7.67 m2
RCP Recém-Nascidos A: 5.11 m2
Mãe Canguru A: 9.88 m2
Armazém A: 3.23 m2
WC Staff A: 4.37 m2
Sanitário Inclusivo A: 5.80 m2
MAT - Circulação A: 13.97 m2
MAT - Circulação A: 2.91 m2
Zona de Espera A: 8.33 m2
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
A= A´
B=B´´ B=B´´
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
C20-28-MAT-01 PLANTA DE PISO TÉRREO 1:100
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-MAT-04
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:100, 1:350
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-MAT-04
A
B
C
D
E
F
BLOCO DA MATERNIDADE
PLANTA COTADA
Ax Bx Cx Dx Ex Hx
1x
2x
3x
4x
Fx Gx
Ramp i = 6.00 %
12x
Rampa i = 6 %
Caleira em betão
Linha de Cobertura
1 2
Sala de Parto A: 24.59 m2
Expurgo A: 2.97 m2
Sala Pós-Parto A: 34.08 m2
Sala de Observação A: 7.67 m2
RCP Recém-Nascidos A: 5.11 m2
Mãe Canguru A: 9.88 m2
Armazém A: 3.23 m2
WC Staff A: 4.37 m2
Sanitário Inclusivo A: 5.80 m2
MAT - Circulação A: 13.97 m2
MAT - Circulação A: 2.91 m2
3.60 2.00 1.50 1.50 2.30 1.80 5.00
2.
1.
3.
7.
1.
18.00
0.2
1.2
1.60
0.5
0.4 5 0.19 4.84 0.19
1.7
7.6
0.5
5.83 5.01 0.50
1.60
8.51 12.12 0.60 2.11
2.69 17.94 2.71
23.23
1.2
7.0
0.72
5.40 0.20 1.30 0.20
1.30 0.20 3.90 0.20 4.78
2.50 0.90
3.5
0.1
5.5
2.6
0.2
1.4
0.2
2.8
0.2
0.3 50.1
5 0.4
0.2
7.2
3.5
1.6
1.1
2.6
0.2
1.4
0.2
1.7
0.2
0.5
0.2
1.8
30.62 0.15 3.48 0.15 0.51
0.20
1.10 0.81
1.75
1.75
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
80X120
A= A´
B=B´´ B=B´´
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
C20-28-MAT PLANTA COTADA 1:100
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-MAT-05
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:650, 1:50
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-MAT-05
A
B
C
D
E
F
BLOCO DA MATERNIDADE
CORTE A
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
±0.00
-0.45
2.23 0.04 1.44 2.72 0.08 1.60 2.52 0.48 1.79 1.92
Viga de betão armado invertida Ver projecto estrutural.
Acabamento da alvenaria interior com CEMCRETE CemCote Brushed OchreSala de Parto
Entrada Sala de Observação
12x 1x 2x 3x 4x
DET-03
±0.00
+2.80
±0.00
+1.10
+2.35
+3.28
+2.35
+4.00
+5.25
3.0
1.1
1.1
2.4
0.3
0.7
±0.00
+3.00
3.0
0.4
1.44 0.88 3.53 3.00 1.19 10.02
-0.35
2.3
0.0
0.3
0.7
0.3 50.1
0.4
1.4
0.4
00.0 90.1
2 0.2
2.3
0.0
0.3
2.1
0.8
0.3
2.2
0.4
0.1
1.5
+5.25
+7.05
Estrutura metálica galvanizada como suporte Ver detalhes no desenho C20-28-
DET-02
Tecto falso em placas soltas e revestidas, com 1200x600 e espessura de 12,5mm, incluindo estrutura metálica galvanizada para suporte, com arame galvanizado de 3mm.
Ver detalhe no desenho C20-28-DET-02
Caleiras de betão armado Ver detalhes no desenho
C20-28-DET-03
Cobertura de betão armado com inclinação i=5% Ver detalhes no desenho C20-28-DET-03
Janela de madeira maciça Chanfuta (afzelia quanzensis) Ver detalhes no desenho C20-28-W01
Tubo de queda em PVC
Caleiras de betão armado Ver detalhes no desenho
C20-28-DET-03
Reservatório Elevado 5000l
Acabamento da alvenaria exterior com CEMCRETE CEMWASH OCHRE/Light Grey
Ver projecto estrutural.
Guarda-fogos (Alvenaria) Ver detalhes no desenho C20-28-DET-03
Viga de Betão Armado Ver projecto estrutural.
Passeio com acabamento em betonilha esquartelada para proteção das fundações.
Acabamento do piso em betonilha preparada para aplicar o CEMCRETE Colour Hardener Gray.
Ver projecto estrutural.
Rede mosquiteira em aço inoxidável
(AISI 304)
Corredor Coberto
A=A´´ CORTE A - BLOCO DA MATERNIDADE 1:50
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-MAT-06
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:650, 1:60
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-MAT-06
A
B
C
D
E
F
BLOCO DA MATERNIDADE
CORTE B
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
Estrutura metálica galvanizada como suporte Ver detalhes no desenho C20-28-
DET-02
Tecto falso em placas soltas e revestidas, com 1200x600 e espessura de 12,5mm, incluindo estrutura metálica galvanizada para suporte, com arame galvanizado de 3mm.
Acabamento da alvenaria exterior com CEMCRETE CEMWASH OCHRE/Light Grey
Reservatório Elevado
Acabamento da alvenaria interior com CEMCRETE CemCote Brushed Ochre
Janela de madeira Chanfuta (afzelia quanzensis) Ver detalhes no desenho C20-28- W01
Rede mosquiteira em aço inoxidável (AISI 304) lavatório embutido em bancada de betão armado.
Escada metálica fixa na parede
Ax Bx Cx Dx Ex Fx Gx Hx
+2.25 +2.25
+1.10
+3.38
-0.45
±0.00 ±0.00
2.9
0.3
1.1
1.1
0.7
2.9
0.3
0.1
2.71 17.70 2.71
-0.35 -0.35
+7.05
+5.25
+4.00
1.7
0.5
0.7
0.3
1.0
1.1
1.1
0.7
2.9
0.3
0.8
0.1
1.2
0.8
0.3
1.1
1.1
0.7
0.3
2.71 1.48 2.12 0.69 1.31 0.00 1.50 1.50 1.48 0.82 1.81 1.56 3.43 0.77 0.65 1.29
Cobertura de betão armado com inclinação i=5% Ver detalhes no desenho C20-28-DET-03
Viga de Betão Armado Ver projecto estrutural.
Ver projecto estrutural.
Passeio com acabamento em betonilha esquartelada para proteção das fundações.
Acabamento do piso em betonilha preparada para aplicar o CEMCRETE Colour Hardener Gray.
Guarda-fogos (Alvenaria) Ver detalhes no desenho C20-28-DET-03
Sala de Observação Sanitário Inclusivo Sala Pós-partoSala de Parto Expurgo WC Staff
TANQUE DE ÁGUA 2500 Litros
B=B´´ CORTE B - BLOCO DA MATERNIDADE 1:60
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-MAT-07
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:100, 1:650
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-MAT-07
A
B
C
D
E
F
BLOCO DA MATERNIDADE
ALÇADOS
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
Caleira em betão
Caleira em betão
Linha da cobertura
Linha de Cobertura
1 2
1 2 3
Rampa i = 6 %
Sala de Parto A: 24.59 m2
Copa A: 4.43 m2
Expurgo A: 2.97 m2
Sala de Admissão/Pré-natal A: 8.51 m2
Sala de Pródromos A: 6.57 m2
Sala Pós-Parto A: 34.08 m2
Sanitário Inclusivo A: 6.37 m2
Sala de Observação A: 7.67 m2
RCP Recém-Nascidos A: 5.11 m2
Armazém A: 2.70 m2
Mãe Canguru A: 9.88 m2
Zona de Espera A: 5.80 m2
Armazém A: 3.23 m2
WC Staff A: 4.37 m2
Sanitário Inclusivo A: 5.80 m2
Sala de Baterias A: 3.02 m2
MAT - Circulação A: 13.97 m2
MAT - Circulação A: 2.91 m2
PBT-Corredor A: 11.75 m2
Zona de Espera A: 8.33 m2
PRÉ-NATAL
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO
APOIADO
2500 Litros
-0.45
±0.00
+2.25
+3.09
+5.13
+7.05
-0.45
-0.45
±0.00
+3.12
+3.92
+5.13
+7.05
-0.45
±0.00
+3.12
+3.92
0.00 0.12
-0.45-0.45
+3.92
-0.45
+1.05
+3.44
+7.05
-0.45
+2.76
+3.44
+4.00
+5.13
+7.05
-0.45
+3.92
MAT ALÇADO FRONTAL 1:100
MAT ALÇADO POSTERIOR 1:100
MAT ALÇADO LATERAL ESQUERDO 1:100
MAT ALÇADO LATERAL DIREITO 1:100
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-MAT-08
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:100, 1:350
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-MAT-08
A
B
C
D
E
F
BLOCO DA MATERNIDADE
PLANTA DE VÃOS (PORTAS, JANELAS E GRELHAS)
Ramp i = 6.00 %
ND-1d
2.
0.
ND-1d
2.
0.
ND-1d
2.
0.
ND-1c
2.
0.
ND-1b
2.
1.
NW-1C
0.
1.
Sill 1.65
NW-1C
0.
1.
Sill 1.65
NW-1C
0.
1.
Sill 1.65
N D
-1 f
2.10 0.90
N D
-1 a
2.10 1.20
ND-1a
2.
1.
N D
-1 a
2.10 1.20
NW-1a
1.
1.
Sill 1.00
NW-1a
1.
1.
Sill 1.00
ND-1d
2.
0.
Rampa i = 6 %NW-1C
0.
1.
Sill 1.65
NW-1b
1.
1.
Sill 1.00
NW-1b
1.
1.
Sill 1.00
NW-1b
1.
1.
Sill 1.00
NW-1b
1.
1.
Sill 1.00
NW-1b
1.
1.
Sill 1.00
MG02
1.
3.
Sill 0.00
MG03
1.
4.
Sill 0.00
Caleira em betão
Linha de Cobertura
1 2
Sala de Parto A: 24.585 m2
Expurgo A: 2.968 m2
Sala Pós-Parto A: 34.082 m2
Sala de Observação A: 7.673 m2
RCP Recém-Nascidos A: 5.107 m2
Mãe Canguru A: 9.882 m2
Armazém A: 3.226 m2
WC Staff A: 4.375 m2
Sanitário Inclusivo A: 5.796 m2
MAT - Circulação A: 13.975 m2
MAT - Circulação A: 2.912 m2
NW-1b
1.
1.
Sill 1.00
NW-1C
0.
1.
Sill 1.65
NW-1b
1.
1.
Sill 1.00
NW-1C
0.
1.
Sill 1.65
NW-1a
1.
1.
Sill 1.00
NW-1a
1.
1.
Sill 1.00
NW-1a
1.
1.
Sill 1.00
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO APOIADO
2500 Litros
A= A´
B=B´´ B=B´´
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
C20-28-MAT-08 PLANTA DE VÃOS 1:100
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
CONSULTEC
Consultores Associados, Lda
CONSULTEC
Consultores Associados, Lda
GSPublisherVersion 0.0.100.100
2 3 4 5 61 7 8 9 10 11 12
2 3 4 5 61 7 8 9 10 11
B
C
D
A
E
F
G
H
B
C
D
A
E
F
G
H
No. de Desenho |Nr. DWG Descrição|Descrip on
Notas | Notes:
Data | DateRev. Descrição|Descrip on
No. Projecto | Project Nr:
REVISÕES DO PROJECTO|PROJECT REVIEWS
Especialidade | Discipline:
OJ OJ01 BA OMC20-28
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
A2
Fase do Projecto | Project Phase :
Eng º Orlando Mavie
Revisão| Revision:Data | Date: Escala | Scale: Formato | Format: Folha nº| Nr Sheet:
Coordenador do Projecto | Project Manager
OJ OJ BA OM
Ficheiro|File:
No. DWG:
Nr. DWG Cliente|Client DWG No.:
Projecto Executivo|Detailed Design
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
For Approval
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
Arquitectura|Architecture
Health Center.Pln
C-20-28-ARQ-N-ED-D-C20-28-HW-01
02/24
1:0.77, 1:102/24
MATERNIDADE TIPO | MATERNITY MODEL DESIGN
C20-28-MAT-09
BLOCO DA MATERNIDADE
MAPA DE VÃOS
0.20
1.3
1.29
0.3
3.45
1.2
4.85
1.2
2.85
1.6
G05 MG01 MG02 MG03 MG04
22 1 1 1 1
0.20×1.30 1.29×0.32 3.45×1.25 4.85×1.25 2.85×1.60
150x150x150mm 150x150x150mm 150x150x150mm 150x150x150mm 150x150x150mm
Ref. ND-1a ND-1b ND-1c ND-1d ND-1f
1.20
2.1
1.20
2.1
0.95
2.1
0.80
2.1
0.90
2.1
3 1 1 4 1
1.12×2.06 1.14×2.07 0.89×2.07 0.74×2.07 0.84×2.07
1.20×2.10 1.20×2.10 0.95×2.10 0.80×2.10 0.90×2.10
2.10 2.10 2.10 2.10 2.10
Porta de dupla batente com dobradiças duplas, feita em madeira maciça de Chanfuta.
Porta basculante de uma só folha em madeira maciça chanfuta
(1) Folha de porta, feita em madeira de Chanfuta de alta qualidade (especificações técnicas).
Maderia Maciça de Chanfuta
DORMA DDS-017 DORMA DDS-017 - - -
Ref. NW-1a NW-1b NW-1C
1.20
1.1
1.20
1.1
1.20
0.5
5 7 6
1.20×1.15 1.20×1.15 1.20×0.50
1.20×1.15 1.20×1.15 1.20×0.50
1.10 1.10 1.75
2.25 2.25 2.25
Mapa de Vãos: Grelhas de Cimento - Bloco Maternidade
Mapa de Vãos: Portas - Bloco Maternidade
Mapa de Vãos: Janelas - Bloco Maternidade
Quantidade Dimensões Dimensão do Vão Altura do Peitoril
Altura do Lintel
Tipo
Folha da Janela
Dobradiças
Fechaduras
Material
Acabamento
Notas
Quantidade Dimensão da folha Dimensão do Vão Altura do Lintel
Tipo
Folha da Porta
Protecção da Porta
Batente de porta
Acabamento
Notas
Madeira de Chanfuta maciça
Acabamento de verniz sobre primário apropriado.
Todos os acessórios recomendados pelo fabricante para óptimo desempenho.
Madeira de Chanfuta maciça
Madeira de Chanfuta maciça
Todos os acessórios recomendados pelo fabricante para óptimo desempenho.
Todos os acessórios recomendados pelo fabricante para óptimo desempenho.
Dois (2) caixilhos fixos com persianas standard + 2 caixilhos fixos com redes mosquiteiras
Duas (2) folhas simples de abrir com dobradiças + 2 caixilhos de duas folhas com dobradiças com redes mosquiteiras
Duas (2) folhas simples de abrir com dobradiças + 2 caixilhos de duas folhas com dobradiças com redes mosquiteiras
Vidro transparente com espessura de
4mm + Rede mosquiteira em Aço
Inoxidável (AISI 304).
Folhas fixas de madeira tipo beta com 5mm de espessura da
Naco + Rede mosquiteira em Aço
Inoxidável (AISI 304).
Conforme nos desenhos técnicos.
Conforme nos desenhos técnicos.
Conforme nos desenhos técnicos.
Conforme nos desenhos técnicos.
Conforme nos desenhos técnicos.
Vidro transparente com espessura de
4mm + Rede mosquiteira em Aço
Inoxidável (AISI 304).
Acabamento em verniz
Acabamento em verniz
Acabamento em verniz
Acabamento em verniz
Acabamento em verniz
Todos os acessórios recomendados pelo fabricante para óptimo desempenho.
Todos os acessórios recomendados pelo fabricante para óptimo desempenho.
Todos os acessórios recomendados pelo fabricante para óptimo desempenho.
Todos os acessórios recomendados pelo fabricante para óptimo desempenho.
Todos os acessórios recomendados pelo fabricante para óptimo desempenho.
Chapa de aço inoxidável com 2mm de espessura
Chapa de aço inoxidável com 2mm de espessura
Porta de batente em madeira maciça chanfuta
Porta de batente em madeira maciça chanfuta
Porta de dupla batente com dobradiças duplas, feita em madeira maciça de Chanfuta.
Grelhas de cimento
Acabamento das grelhas com
CEMCRETE
SATINCRETE Dolphin Grey
Grelhas de cimento Grelhas de cimento Grelhas de cimento Grelhas de cimento
Acabamento das grelhas com
CEMCRETE
SATINCRETE Dolphin Grey
Acabamento das grelhas com
CEMCRETE
SATINCRETE Dolphin Grey
Acabamento das grelhas com
CEMCRETE
SATINCRETE Dolphin Grey
Acabamento das grelhas com
CEMCRETE
SATINCRETE Dolphin Grey
Madeira de chanfuta maciça revestida com uma placa de aço inoxidável de 2 mm de espessura na parte inferior
Madeira de chanfuta maciça revestida com uma placa de aço inoxidável de 2 mm de espessura na parte inferior
(1) Folha de porta, feita em madeira de
Chanfuta de alta qualidade
(especificações técnicas).
Ref.
Quantidade
Dimensões
Tipo
Acabamento
Acabamento de verniz sobre primário apropriado.
Acabamento de verniz sobre primário apropriado.
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-PBT-02
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:350, 1:100
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-PBT-02
A
B
C
D
E
F
BLOCO PRÉ-NATAL
PLANTA DE COBERTURA
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
Caleira em betão
Linha da cobertura
Linha de Cobertura
1 2
1 2 3
Rampa i = 6 %
Copa A: 4.43 m2
Sala de Admissão/Pré-natal A: 8.51 m2
Sala de Pródromos A: 6.57 m2
Sanitário Inclusivo A: 6.37 m2
Armazém A: 2.70 m2
Zona de Espera A: 5.80 m2
Sala de Baterias A: 3.02 m2
MAT - Circulação A: 2.91 m2
PBT-Corredor A: 11.75 m2
Zona de Espera A: 8.33 m2
PRÉ-NATAL
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO
APOIADO
2500 Litros
A= A´
C=C´´ C=C´´
D=D D=D
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
Área Coberta - Maternidade Cobertura 2 - Pré-Natal: 106.42 m2
Planta Geral da Maternidade
1x
Jx Cx Nx
6x
10x
8x
11x
DxLxIx
9x
7x
5x
4x
12x
Kx MxA= A´
C=C´´ C=C´´
D=D D=D
Caleira em betão
Cobertura 2
PLANTA DE COBERTURA 1:100
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-PBT-03
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:350, 1:100
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-PBT-03
A
B
C
D
E
F
BLOCO PRÉ-NATAL
PLANTA DE PISO TÉRREO
Ramp i = 6.00 %
Ramp i = 6.00 %
Rampa i = 6 %
D-07
1 2
1 2 3
Rampa i = 6 %
Ramp i = 6.00 %
D-07
Caleira em betão
Linha da cobertura
Linha de Cobertura
1 2 3
Rampa i = 6 %
Copa A: 4.43 m2
Sala de Admissão/Pré-natal A: 8.51 m2
Sala de Pródromos A: 6.57 m2
Sanitário Inclusivo A: 6.37 m2
Armazém A: 2.70 m2
Zona de Espera A: 5.80 m2
Sala de Baterias A: 3.02 m2
PBT-Corredor A: 11.75 m2
Zona de Espera A: 8.33 m2
PRÉ-NATAL
MATERNIDADE
Tanque de Água Ver detalhes no desenho
C20-28-DET-01 RESERVATÓRIO
APOIADO
2500 Litros
A= A´
C=C´´ C=C´´
D=D D=D
C20-28-PBT-02 PLANTA DE PISO TÉRREO 1:100
Projecto Executivo|Detailed Design
Arquitectura|Architecture
MATERNITY TYPE.pln
C-20-28-ARQ-N-MAT-D-C20-28-PBT-04
2 3 4 5 61 7 8
2 3 4 5 61 7
A
B
C
D
E
F
CONSULTEC
Consultores Associados, Lda
Data | Date
Fase do Projecto | Project Phase :
Especialidade | Discipline:
A3
No. DWG: Escala | Scale Formato | Format
REVISÕES DO PROJECTO|PROJECT REVIEWS
Folha nº | Nr Sheet
No. Projecto | Project Nr:
0002/24
Rev Data | DateDescrição | Descrip on
Este desenho é propriedade da Consultec - Consultores Associados Lda. e é destinado ao uso apenas no local e ao projecto a que se refere.
Os direitos autorais deste desenho pertencem à Consultec - Consultores Associados Lda.
This drawing is the property of Consultec - Consultores Associados Lda. and is intended for the use only on site and for the project to which it relates. Copyright in this drawing is owned by Consultec - Consultores Associados Lda.
Notas | Notes:
No. 169
Moçambique Maputo Tel: +258 21 491555/83 Fax: +258 21 491578
Rua Tenente General Oswaldo Tazama
OMBA
Coordenador do Projecto | Project Manager
Eng º Orlando Mavie
CONSULTEC
Consultores Associados, Lda
Ficheiro|File:
Nr. DWG Cliente: -
Revisão| Revision :
1:350, 1:100
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
Aprovado| Approved
Verificado| Checked
Desenhado| Drawn
Projectado| Designed
02/24OMFor Approval BA
Mozambique Architecture and Engineering (A&E) services for the Design and Construction Oversight Services for Rehabilitation and Upgrade of Health Facilities in Nampula Province
OJ OJ
OJ OJ MATERNIDADE TIPO | MATERNITY MODEL DESIGN
Descrição|Descrip on C20-28-PBT-04
A
B
C
D
E
F
BLOCO PRÉ-NATAL
PLANTA COTADA
Ramp i = 6.00…