01_DRAFT_CNT2_Plans_4Civil_Part6.pdf
PDF 2 MB Posted
- Solicitation number
- W912EP25Z0012
About this file
This is a general civil notes and symbols sheet containing construction specifications for the Broward County Water Preserve Areas Project Contract 2, which involves the C-11 Impoundment and Mitigation Area A in Broward County, Florida. The sheet includes detailed civil engineering notes covering traffic control, utilities, and general construction requirements.
The notes address key requirements including: dewatering activities, dust and vibration control, stormwater pollution prevention, site protection measures, utility coordination, traffic control compliance with MUTCD standards, excavation specifications up to elevation 6.0' NAVD88, environmental permit requirements, and construction staging area protocols. The sheet also provides comprehensive civil engineering symbols and legends for items like riprap, slurry walls, embankments, utilities, fencing, drainage features, and various site structures and markers. The drawing is marked as "CONTRACT 2 MOD003 - FOR INFORMATION ONLY - NOT REVIEWED - NOT FOR CONSTRUCTION" dated 12/06/2024.
View the file
Other files
Show 40 more
Latest 50 of 56 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H
PB
MW
FLOW
FLOW
D
W W
E B
E R
G
N E
R A
L C
IV
IL
N O
T E
S A
N D
S Y
M B
O L
S
C-0001
M L
U H
V
S E
V E
R A
N C
M
L
U H
O
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
F
IL
E N
A M
E
D R
A W
IN
G
D A
T E
A N
S I
D
W
E P
-2
-C -X
X X
X
JA
C
K S
O N
V
IL
L E
D
IS
T R
IC
T
S
A N
M A
R C
O B
L V
D
J A
C K
S O
N V
IL
L
E F
L
C
-1 C
N T
C
-C -0
.d g n
U s e r:
m lu h
/1
/2
/0
/2
/0
/2 ta n te c T
E T
R A
T E
C H
J O
I N
T V
E T
U R
E N
J V
I I on any electronic copies.
the signature must be verified signed and sealed and document are not considered
Printed copies of this
Vincent Joseph Severance signed and sealed by
This item has been digitally
License No. 93101
Professional Engineer, State of Florida, Vincent Joseph Severance, B R
O W
A R
D C
O U
N T
Y
F L
O R
ID
A
C O
N T
R A
C T
C
-1 I
M P
O U
N D
M E
N T
A N
D M
IT
IG
A T
IO
N
A R
E A
A
B R
O W
A R
D C
O U
N T
Y W
A T
E R
P R
E S
E R
V E
A R
E A
S P
R O
J E
C T
C O
M P
R E
H E
N S
IV
E
E V
E R
G L
A D
E S
R E
S T
O R
A T
IO
N
P L
A N
C
E R
P
W E
P R
C O
N T
R A
C T
R
T A
S U
B M
IT
T
A L
GENERAL CIVIL NOTES
TRAFFIC CONTROL NOTES
OTHERWISE DIRECTED IN THE FIELD.
TRAFFIC CONTROL DEVICES (MUTCD) AND THE FDOT 102-600 DRAWING SERIES UNLESS
DEVICES AND METHODS, MUST COMPLY WITH THE USDOT MANUAL ON UNIFORM
SIGNAGE. CONSTRUCTION TRAFFIC CONTROL SIGNS, BARRICADES, WARNING LIGHTS,
THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER CONSTRUCTION 2.
STOP ON ROUTE 27 NEAR THE SOUTHWEST SITE ENTRANCE.
CONTRACTOR MUST PROVIDE A MINIMUM OF 1 WEEK NOTIFICATION FOR THE TRUCK
A PRIVATE PROPERTY OWNER IS IMPACTED BY CONSTRUCTION. ADDITIONALLY THE
THE CONTRACTOR MUST PROVIDE A MINIMUM OF 48 HOUR NOTIFICATION IF ACCESS TO 1.
UTILITY NOTES
SHOWN OR NOT SHOWN.
PRECAUTIONARY MEASURES NECESSARY TO PROTECT UTILITY LINES WHETHER
THE CONTRACTOR MUST VERIFY ALL LOCATIONS AND ELEVATIONS AND MUST TAKE ALL 6.
THE CONTRACTOR MUST PROTECT ALL REMAINING EXISTING UTILITIES.5.
DRAWINGS FOR POINTS OF CONNECTIONS.
CONTRACTOR MUST POTHOLE FOR EXISTING UTILITIES PRIOR TO SUBMITTAL OF SHOP
EXISTING UTILITIES IN AND AROUND THE AREAS OF NEW CONSTRUCTION. THE
PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR MUST LOCATE ALL 4.
THE CONTRACTOR.
RESPECTIVE UTILITY ENTITY. ALL REPAIR COSTS MUST BE THE RESPONSIBILITY OF
ENTITIES. ALL REPAIRS OF THE DAMAGED UTILITIES MUST BE DONE BY THE
CONSTRUCTION AND MUST IMMEDIATELY REPORT ANY DAMAGE TO THE UTILITY
EXISTING UTILITIES NOT TO BE DISTURBED WHICH OCCURS BY THEIR FAULT DURING
AREA PRIOR TO DIGGING. THE CONTRACTOR MUST BE RESPONSIBLE FOR DAMAGE TO
CONTACT SUNSHINE ONE CALL FOR MARKING OF UNDERGROUND UTILITIES FOR THIS
LOCATIONS PRIOR TO WORKING NEAR EXISTING UTILITIES. CONTRACTOR MUST
UTILITY LOCATIONS SHOWN ARE APPROXIMATE. CONTRACTOR MUST VERIFY 3.
WITH THE UTILITY OWNER AND THE CONTRACTING OFFICER.
TO ANY CONNECTION TO AN EXISTING UTILITY, THE CONTRACTOR MUST COORDINATE
CONTRACTOR MUST COORDINATE WITH THE RESPECTIVE UTILITY COMPANIES. PRIOR
RELOCATION OF PRIVATE UTILITIES AS REQUIRED MUST BE PERFORMED BY OTHERS. 2.
ALL EXISTING UTILITIES ARE TO REMAIN UNLESS OTHERWISE NOTED.1.
LOWER AREAS ADJACENT TO THE CUT AREAS.
IMPOUNDMENT AREA TO EL. 6.0' NAVD88. EXCAVATED MATERALS MAY BE PLACED IN
CONTRACTOR MUST EXCAVATE ALL HIGH LAND AREAS WITHIN THE CLEARED 25.
OF WESTON, FL CODE OF ORDINANCES SECTION 52.50.
CONTRACTOR MUST ABIDE BY APPLICABLE NOISE REGULATIONS INCLUDING THE CITY 24.
NOTES.
SURFACING AND SEDIMENT PIT. SEE SHEET GC0003 AND GC0004 FOR ADDITIONAL
EGRESS FROM CONSTRUCTION AREAS TO PUBLIC ROADS WITH FDOT #1 AGGREGATE
CONTRACTOR MUST PROVIDE A SOIL TRACKING PREVENTION DEVICE AT ALL POINTS OF 23.
PERMITS PRIOR TO BEGINNING CONSTRUCTION.
CONTRACTOR MUST OBTAIN ALL NECESSARY ENVIRONMENTAL, AGENCY, AND OTHER 22.
OF CONTRACT PER SPECIFICATION SECTION 01 57 20.
CONTRACTOR MUST CLEAN AND REMOVE ALL TRASH IN PROJECT LIMITS PRIOR TO END 21.
EL. 3.8' NAVD88. CONTRACTOR WILL BE RESPONSIBLE FOR ELEVATION VERIFICATION.
CONTRACTOR MAY WASTE MATERIAL WITHIN THE CLEARED IMPOUNDMENT AREA UP TO 20.
STOCKPILE AREAS IDENTIFIED IN THE PLANS.
ALL SATISFACTORY EXCESS MATERIAL MUST BE STOCKPILED IN THE EMERGENCY 19.
AND MISCELLANEOUS SITE DEBRIS.
INCLUDE BUT ARE NOT LIMITED TO: ABANDONED UTILITIES, PAVEMENTS, FOUNDATIONS
OFFSITE AND DISPOSED OF LEGALLY AND PROPERLY. UNSATISFACTORY MATERIALS
DESIGNATED AREAS WILL BECOME PROPERTY OF THE CONTRACTOR AND BE HAULED
ON THE PLANS. EXCAVATED MATERIALS WHICH ARE UNSATISFACTORY FOR USE IN
ALL SATISFACTORY EXCAVATED MATERIAL MUST BE PLACED AS FILL IN AREAS SHOWN 18.
STRUCTURES WITHIN THE PROJECT LIMITS PER SPECIFICATION SECTION 02 41 00.
UNLESS OTHERWISE NOTED, THE CONTRACTOR MUST REMOVE ALL CONCRETE 17.
BRACING SYSTEM OR OTHER SHORING PER SPECIFICATION SECTION 31 00 00.
PROTECT THE SIDES OF THE EXCAVATION BY AN INTERLOCKED SHEETING AND
FENCES, AND OTHER PROPERTY CAUSED BY THEIR EXCAVATION. CONTRACTOR MUST
CAVING OR SETTLING AND FOR ALL DAMAGE TO PAVEMENTS, BUILDINGS, HOUSES,
THE CONTRACTOR IS ENTIRELY RESPONSIBLE TO PROTECT EXCAVATIONS FROM 16.
THE LIMITS OF CLEARING AND GRUBBING SHOWN ON THE DEMOLITION PLANS.
LIMITS OF THE PROJECT INSIDE THE C-11 IMPOUNDMENT, CANAL BANKS, AND WITHIN
UNLESS OTHERWISE NOTED, THE CONTRACTOR MUST REMOVE ALL TREES WITHIN THE 15.
ACTIVITIES EXCEPT FOR AREAS WITHIN THE ENVIRONMENTALLY SENSITIVE AREAS.
THE LIMITS OF CONSTRUCTION, AND THOSE DISTURBED BY THE CONTRACTOR'S
CONTRACTOR MUST SEED AND FERTILIZE ALL NON-PAVED AREAS DISTURBED WITHIN 14.
VERIFY EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION.
CONTRACTOR MUST BE RESPONSIBLE FOR BEING FAMILIAR WITH THE SITE AND MUST 13.
ALONG THE EASTERN LIMITS OF THE PROJECT.
STREET CROSSING TO THE C-11 CANAL AND MAINTAIN FLOW OF EXISTING CANAL C/3
OUTFALL AT C-11, MAINTAIN FLOW OF EXISTING CANAL B/4 FROM THE SOUTHWEST 36TH
DURING CONSTRUCTION THE CONTRACTOR MUST MAINTAIN FLOW TO THE CANAL A/5 12.
IMMEDIATE ACTION TO REDUCE VIBRATIONS TO ACCEPTABLE LIMITS.
02 22 13. IF VIBRATIONS EXCEED ALLOWABLE LIMIT, THE CONTRACTOR MUST TAKE
VIBRATION CONTROL - CONTRACTOR MUST MONITOR VIBRATION. SEE SPECIFICATION 11.
COVERED TO PREVENT BLOWING.
CHEMICAL DUST SUPPRESSANT. DUSTY MATERIALS IN PILES OR IN TRANSIT MUST BE
SUBJECT TO DUSTING MUST BE KEPT MOIST WITH WATER OR BY APPLICATION OF
DUST IN ACCORDANCE WITH SPECIFICATION SECTION 01 50 02. EACH SURFACE
DUST CONTROL - CONTRACTOR MUST TAKE MEASURES TO PREVENT UNNECESSARY 10.
INDICATED IN THE SWPPP.
BMPS MUST BE CONSTRUCTED PRIOR TO ANY GROUND DISTURBING ACTIVITIES AS
(SWPPP) FOR THIS PROJECT PER SPECIFICATION SECTION 01 57 20. ALL NECESSARY
THE CONTRACTOR MUST DEVELOP THE STORMWATER POLLUTION PREVENTION PLAN 9.
CUTS, ETC PER SPECIFICATION SECTION 01 11 00.
MUST BE ESTABLISHED PRIOR TO DESTROYING EXISTING MONUMENTS/NAILS/CROSS
THROUGHOUT CONSTRUCTION. ALL CONTROL POINTS REQUIRED FOR CONSTRUCTION
PERMANENT AND TEMPORARY BENCHMARKS AND ADJUST AS NECESSARY
BENCHMARKS (TBM'S) AS NEEDED. THE CONTRACTOR MUST PERIODICALLY VERIFY
IT MUST BE THE RESPONSIBILITY OF THE CONTRACTOR TO ESTABLISH TEMPORARY
VERIFYING ALL MEASUREMENTS AND GRADES PRIOR TO BEGINNING CONSTRUCTION.
THE CONTRACTOR MUST BE RESPONSIBLE FOR LAYING OUT THE WORK AND 8.
THE CONTRACTING OFFICER.
CONSTRUCTION STAGING AREA AS SHOWN ON THE PROJECT DRAWINGS APPROVED BY
SPECIFICATION SECTION 01 50 02. CONTRACTOR IS TO USE AND MAINTAIN
CONSTRUCTION STAGING AREAS AND HAUL ROADS AS NEEDED FOR WORK PER
CONTRACTOR MUST BE RESPONSIBLE FOR OBTAINING AND MAINTAINING 7.
SPECIFICATION SECTION 01 57 20.
(EPSC) MEASURES ARE ALSO OUTLINED ON SHEETS GC0003 AND GC0004 AND IN
OBSTRUCTIONS. INSTALLATION OF EROSION PREVENTION AND SEDIMENT CONTROL
REMOVAL OF EXISTING STRUCTURES, UTILITIES, VEGETATION, AND OTHER
REFER TO CIVIL SITE DRAWINGS FOR STRIPPING, CLEARING, DEMOLITION AND 6.
BE SCALED.
DRAWINGS AND DETAILS MARKED (NTS) ARE NOT SHOWN TO SCALE AND SHOULD NOT 5.
MUST VERIFY ACTUAL DIMENSIONS IN THE FIELD.
DIMENSIONS AND/OR ELEVATIONS MARKED THUS (±) ARE APPROXIMATE. CONTRACTOR 4.
CONTRACTOR MUST MAINTAIN CONTINUOUS ACCESS TO THE SBA CELL TOWER.3.
GEOID 12B. SEE ADDITIONAL NOTES ON SHEET V-0001.
VERTICAL DATUM (NAVD 1988) AND ARE EXPRESSED IN FEET. BENCH MARK "Y 408"
ELEVATIONS, UNLESS OTHERWISE NOTED, ARE BASED ON THE NORTH AMERICAN 2.
SECTION 31 52 10.
CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING ACTIVITIES PER SPECIFICATION 1.
GENERAL CIVIL NOTES - CONTINUED
31 52 10.
OFF-SITE IN ACCORDANCE WITH APPLICABLE PERMITS, PER SPECIFICATION SECTION
ALL DEWATERING DISCHARGES WITHIN THE LIMITS OF CONSTRUCTION OR DISPOSE
31. CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING ACTIVITIES AND MUST RETAIN
32 92 23.
ALL CONSTRUCTED SLOPES 4H:1V OR STEEPER MUST BE SODDED PER SPECIFICATION 30.
PRIOR TO PROCEDURE.
DRAWINGS, CONTRACTOR MUST NOTIFY CONTRACTING OFFICER FOR VERIFICATION
IF ACTUAL FIELD CONDITIONS VARY SIGNIFICANTLY FROM THE CONSTRUCTION 29.
FILL PER SPECIFICATION 31 00 00.
VEGETATED EMBANKMENT SLOPES MUST BE CONSTRUCTED FROM ORGANIC PUSHED 28.
OR BUILDING.
ALL BUILDING COORDINATES ARE TO OUTSIDE CORNER OF COLUMN 27.
SPECIFICATION SECTION 01 11 00.
THE CONTRACTOR'S EXPENSE WITH NO ADDITIONAL COSTS TO USACE, PER
EXPEDITIOUSLY REPAIRED OR RECONSTRUCTED TO THE SATISFACTION OF OWNER AT
ALL STRUCTURES DAMAGED BY THE CONTRACTOR'S OPERATIONS MUST BE
PROTECT FROM DAMAGE, ALL EXISTING STRUCTURES WHICH ARE TO REMAIN IN PLACE.
NECESSARY TO THE CONTRACTOR MUST TAKE ALL PRECAUTIONARY MEASURES 26.
FLOW
FLOW
L1
C1
TEMPORARY LIMITS OF CONSTRUCTION
LIMITS OF CONSTRUCTION
RIGHT OF WAY
RIPRAP PLAN VIEW
CANAL BOTTOM
TEMPORARY FENCE
SECURITY FENCE
STORM DRAIN
SLURRY WALL
GUARDRAIL
DRAINAGE DITCH
ELECTRIC SERVICE
ELECTRIC PRIMARY
WATER LINE
CENTERLINE
PROPOSED CONTOURS
SOIL-CEMENT
SLURRY WALL NOTES
FOR SLURRY WALL NOTES AND DETAILS SEE SHEET CF0004.1.
(STONE TYPE VARIES)
RIPRAP SECTION VIEW
EMBANKMENT FILL
FINE FILTER SAND
CLSM
CONCRETE
EXISTING TEMPORARY LIMITS OF CONSTRUCTION
EXISTING LIMITS OF CONSTRUCTION
EXISTING PROPERTY LINE
EXISTING RIGHT OF WAY
EXISTING RIPRAP PLAN VIEW
EXISTING CANAL BOTTOM
EXISTING TEMPORARY FENCE
EXISTING SECURITY FENCE
EXISTING STORM DRAIN
EXISTING STORM SEWER
EXISTING SLURRY WALL
EXISTING GUARDRAIL
EXISTING DRAINAGE DITCH
EXISTING ELECTRIC SERVICE
EXISTING ELECTRIC/FIBER OPTIC
EXISTING ELECTRIC PRIMARY
EXISTING COMMUNICATION/FIBER OPTIC
EXISTING WATER LINE
EXISTING CENTERLINE
EXISTING CONTOURS
EXISTING STILLING WELL WALKWAY
EXISTING STAFF GAUGE
EXISTING THREE POLE MOUNT RTU
EXISTING BOLLARD
EXISTING DANGER SIGN
EXISTING BOAT WARNING SIGN
EXISTING CLEANOUT
EXISTING MANHOLE
EXISTING DOUBLE VEHICLE GATE
EXISTING SINGLE VEHICLE GATE
EXISTING FLOW ARROW RIGHT
EXISTING FLOW ARROW LEFT
EXISTING BORINGS AND TEST PITS
EXISTING TRAFFIC SIGNAL
EXISTING HANDHELD JUNCTION BOX
EXISTING POWER JUNCTION BOX
EXISTING VALVE PIT
EXISTING MONITORING WELL
EXISTING ROAD SIGN
EXISTING POWER POLE
(STONE TYPE E)
BLANKET DRAIN
2% 2%
EXISTING SOIL-CEMENT
EXISTING GRAVEL/DRAINROCK/AGGREGATE BASE
VIEW (STONE TYPE VARIES)
EXISTING RIPRAP SECTION
EXISTING EMBANKMENT FILL
EXISTING FINE FILTER SAND
EXISTING CLSM
EXISTING CONCRETE
(STONE TYPE E)
EXISTING BLANKET DRAIN
EXISTING SUBGRADE
GRAVEL/DRAINROCK/AGGREGATE BASE
CIVIL SYMBOLS
WALKWAY
STILLING WELL
POST
BAT HOUSE
STAFF GAUGE
THREE POLE MOUNT RTU
BOLLARD
DANGER SIGN
BOAT WARNING SIGN
CLEANOUT
MANHOLE
DOUBLE VEHICLE GATE
SINGLE VEHICLE GATE
VIBRATING WIRE PRESSURE SENSOR
SURVEY SETTLEMENT MARKER
LINE OR CURVE DATA SEGMENT LABELS
WATER LEVEL INDICATOR
SLOPE INDICATOR
SLOPE LINE
FLOW ARROW RIGHT
FLOW ARROW LEFT
BORINGS AND TEST PITS
POWER POLE
D
C O
N
TR
AC
T
M
O D
- F O
R
IN
FO
R
M
AT
IO
N
O N
LY
N O
T R
EV
IE
W
ED
N
O T
FO
R
C O
N
ST
R U
C
TI
O N
/0
6/
C O
N
TR
AC
T
M
O D
- F
IN
AL
N O
T
FO
R C
O N
ST
R
U C
TI
O
NDRAFT
k3endlml Stamp
File details come from the government source that posted it. Updated .