Z2DA--Replace Auxiliary Chiller
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- 36C24626B0004
- Agency
- Veterans Integrated Service Network 6 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Fayetteville Veterans Affairs Medical Center Fayetteville, North Carolina 28301, United States
- Points of contact
-
- Michael Proctor michael.proctor2@va.gov
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 is conducting a Sources Sought Notice to identify qualified vendors for replacing an auxiliary chiller system at the Fayetteville Veterans Affairs Medical Center Building 3. The project involves removing and replacing an existing 120-ton auxiliary chiller, installing two new 250 gpm pumps, and integrating all new equipment with the existing Building Automation System (BAS) using BACNET compliant controllers. Contractors must provide all labor, materials, tools, equipment, transportation, supervision, and coordination necessary to complete the scope of work, including updating graphics, trends, and digital alarming on the Tridium Direct Digital Control Supervisor. The procurement falls under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors) with a size standard of $19.0 million. Interested vendors must submit their responses by 3:00 PM EDT on October 22, 2025, including company details, SAM registration, capabilities statement, bonding capacity, and socio-economic size classification.
This market research notice indicates no set-aside is currently designated, though the VA may consider a Service-Disabled Veteran-Owned Small Business (SDVOSB) or Veteran-Owned Small Business (VOSB) set-aside based on the responses received. No incumbent contractors are identified in the documentation. The anticipated project value ranges between $250,000 and $500,000, representing a Magnitude of Construction procurement. The performance period is expected to be 6 months from the Notice to Proceed. The replacement chiller must match the existing 120-ton capacity to provide chilled water redundancy to Building 3, and contractors may reuse existing concrete pads for the installation.
Notice text
THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited.
The VHA Network Contracting Office 6 (NCO 6) is conducting a market survey to find qualified vendors to provide all labor, materials, tools, equipment, transportation, supervision, coordination, and services necessary to complete the below scope of work.
The proposed NAICS 238220 is applicable to this acquisition; with a size standard of $19.0 million.
The anticipated Magnitude of Construction is between $250,000 and $500,000. The anticipated Period of Performance is 6 months from the Notice to Proceed.
Scope of Work:
Remove and replace the existing 120-ton auxiliary chiller at Building 3. The purpose of this chiller is to provide chilled water redundancy to Building 3. The new auxiliary chiller shall be the same size/capacity as the existing chiller and shall be fully functional.
The contractor shall replace and install all required piping, valves, supports, and controls. The new auxiliary chiller shall be integrated with the existing Building Automation System (BAS). Chiller controller shall be BACNET compliant, and all data points should be pulled through the BACNET connection. The contractor shall install minimum (hard wired) data points to include but not limited to (1) Start/Stop, (2) Status, and (3) Alarm (hard wired). All low voltage control wirings must be installed in blue control conduit. All graphics/trends and digital alarming associated with the new chiller must be updated on the Tridium Direct Digital Control (DDC) Supervisor located in Room 2 in Building no. 35.
The contractor shall replace two (2) 250 gpm pumps located in an adjacent mechanical room. Contractor may reuse the existing concrete pads. Replace/reroute piping, if required, to install the new pumps. Pumps shall be programmed into the BAS with the same data points as the chiller.
Instructions:
The CO will consider responses received for this Sources Sought Notice, along with any other market research that is conducted, when determining the appropriate acquisition strategy. Pursuant to 38 U.S.C. 8127(d), CO s must set aside all acquisitions for SDVOSBs or VOSBs whenever there is a reasonable expectation of receiving two or more offers/quotes from eligible, capable and verified firms, and that an award can be made at a fair and reasonable price that offers best value to the Government. However, if responses from qualified firms prove inadequate, an alternate set-aside or full and open competition may be considered.
In order to be considered eligible for an SDVOSB or VOSB Set-Aside, interested firms must confirm in their response to this Sources Sought Notice that they will be able to comply with all the following criteria:
VA Acquisition Regulation (VAAR) 819.7003 - Eligibility
VAAR Clause 852.219-73 SDVOSB Set-Aside or 852.219-74 VOSB Set-Aside
VAAR Clause 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction.
All interested parties should respond, in writing via email to Michael.Proctor2@va.gov. No telephone inquiries will be accepted. Your response is required by 3:00 PM EDT on Wednesday, October 22, 2025. In your response, please include the following:
Company name
Address
Point of contact with email and phone number
SAM Unique Entry ID number and evidence of current SAM registration (see https://www.sam.gov for more information)
Proposed NAICS code (if different from above)
Capabilities statement, to include experience with contracts of similar scope and magnitude
Information describing your interest
Information demonstrating your company has the capacity to complete this project, to include available bonding capacity
Company Socio-Economic SIZE (example large, small, SDVOSB, VOSB, WOSB etc.)
A brief statement on how you will comply with the Limitations on Subcontracting, if applicable
In addition to this information, please include responses to all of the following in your submission:
What additional information would you require in order to provide an offer for this project?
Is the anticipated Period of Performance sufficient to complete the project?
Is the anticipated Magnitude of Construction appropriate for this project?
Attachments
| File | Type | Posted |
|---|---|---|
| 36C24626B0004.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z2DA--Replace Auxiliary Chiller | Award Notice | |
| Z2DA--Replace Auxiliary Chiller | Solicitation | |
| Z2DA--Replace Auxiliary Chiller | Pre-Solicitation | |
| Z2DA--Replace Auxiliary Chiller | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity