This is a Sources Sought Notice for a Department of Veterans Affairs (VA) project at the Fayetteville Veterans Affairs Medical Center. The VA Network Contracting Office 6 is conducting market research to identify qualified vendors for replacing an auxiliary chiller in Building 3, with an anticipated project value between $250,000 and $500,000. The 6-month project involves removing the existing 120-ton auxiliary chiller, installing a new chiller of equivalent size, replacing two 250 gpm pumps, and integrating the new equipment with the existing Building Automation System (BAS).
The solicitation (36C24626B0004) targets NAICS code 238220 with a size standard of $19.0 million and has a potential Service-Disabled Veteran-Owned Small Business (SDVOSB) or Veteran-Owned Small Business (VOSB) set-aside. Interested vendors must submit a response by 3:00 PM EDT on October 22, 2025, via email to Michael Proctor, including company details, SAM registration, capabilities statement, bonding capacity, and socio-economic size classification. The VA will use the responses to determine the most appropriate acquisition strategy, with potential for a set-aside or full and open competition depending on the market research results.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Replace Auxiliary Chiller |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 23249 |
| SOLICITATION NUMBER* |
| 36C24626B0004 |
| RESPONSE DATE/TIME/ZONE |
| 10-22-2025 3:00PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 99 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| Z2DA |
| NAICS CODE* |
| 238220 |
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs Network Contracting Office 6 1201 Broad Rock Blvd Richmond VA 23249
POINT OF CONTACT*
Contracting Officer Michael Proctor Michael.Proctor2@va.gov
EMAIL ONLY
PLACE OF PERFORMANCE
| ADDRESS |
| Fayetteville Veterans Affairs Medical Center |
2300 Ramsey Street
Fayetteville NC
| POSTAL CODE |
| 28301 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/ |
| URL DESCRIPTION |
| Department of Veterans Affairs |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Michael.Proctor2@va.gov |
| EMAIL DESCRIPTION |
| Michael Proctor, Contracting Officer |
THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited.
The VHA Network Contracting Office 6 (NCO 6) is conducting a market survey to find qualified vendors to provide all labor, materials, tools, equipment, transportation, supervision, coordination, and services necessary to complete the below scope of work.
The proposed NAICS 238220 is applicable to this acquisition; with a size standard of $19.0 million.
The anticipated Magnitude of Construction is between $250,000 and $500,000. The anticipated Period of Performance is 6 months from the Notice to Proceed.
Scope of Work:
Remove and replace the existing 120-ton auxiliary chiller at Building 3. The purpose of this chiller is to provide chilled water redundancy to Building 3. The new auxiliary chiller shall be the same size/capacity as the existing chiller and shall be fully functional.
The contractor shall replace and install all required piping, valves, supports, and controls. The new auxiliary chiller shall be integrated with the existing Building Automation System (BAS). Chiller controller shall be BACNET compliant, and all data points should be pulled through the BACNET connection. The contractor shall install minimum (hard wired) data points to include but not limited to (1) Start/Stop, (2) Status, and (3) Alarm (hard wired). All low voltage control wirings must be installed in blue control conduit. All graphics/trends and digital alarming associated with the new chiller must be updated on the Tridium Direct Digital Control (DDC) Supervisor located in Room 2 in Building no. 35.
The contractor shall replace two (2) 250 gpm pumps located in an adjacent mechanical room. Contractor may reuse the existing concrete pads. Replace/reroute piping, if required, to install the new pumps. Pumps shall be programmed into the BAS with the same data points as the chiller.
Instructions:
The CO will consider responses received for this Sources Sought Notice, along with any other market research that is conducted, when determining the appropriate acquisition strategy. Pursuant to 38 U.S.C. 8127(d), CO’s must set aside all acquisitions for SDVOSBs or VOSBs whenever there is a reasonable expectation of receiving two or more offers/quotes from eligible, capable and verified firms, and that an award can be made at a fair and reasonable price that offers best value to the Government. However, if responses from qualified firms prove inadequate, an alternate set-aside or full and open competition may be considered.
In order to be considered eligible for an SDVOSB or VOSB Set-Aside, interested firms must confirm in their response to this Sources Sought Notice that they will be able to comply with all the following criteria:
· VA Acquisition Regulation (VAAR) 819.7003 - Eligibility
· VAAR Clause 852.219-73 – SDVOSB Set-Aside or 852.219-74 – VOSB Set-Aside
· VAAR Clause 852.219-75 – VA Notice of Limitations on Subcontracting—Certificate of Compliance for Services and Construction.
All interested parties should respond, in writing via email to Michael.Proctor2@va.gov. No telephone inquiries will be accepted. Your response is required by 3:00 PM EDT on Wednesday, October 22, 2025. In your response, please include the following:
· Company name
· Address
· Point of contact with email and phone number
· SAM Unique Entry ID number and evidence of current SAM registration (see https://www.sam.gov for more information)
· Proposed NAICS code (if different from above)
· Capabilities statement, to include experience with contracts of similar scope and magnitude
· Information describing your interest
· Information demonstrating your company has the capacity to complete this project, to include available bonding capacity
· Company Socio-Economic SIZE (example…large, small, SDVOSB, VOSB, WOSB etc.)
· A brief statement on how you will comply with the Limitations on Subcontracting, if applicable In addition to this information, please include responses to all of the following in your submission:
· What additional information would you require in order to provide an offer for this project?
· Is the anticipated Period of Performance sufficient to complete the project?
· Is the anticipated Magnitude of Construction appropriate for this project?
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .