Z2DA--436-20-105 Bldg. 150 Sanitary Sewer Replacement
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25922R0096
- Agency
-
Veterans Integrated Service Network 19
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks proposals to replace the sanitary sewer system located under Building 150 at the Fort Harrison VA Medical Center in Montana. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19 will evaluate proposals based on technical qualifications, past performance, and price. Offerors must submit proposals by October 20, 2022 and have relevant experience replacing underground piping systems. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses and involves replacing approximately 105 linear feet of 4-inch sanitary sewer piping.
The NAICS code for this requirement is 238220 - Plumbing, Heating, and Air-Conditioning Contractors. The estimated contract value ranges from $250,000 to $500,000. Work must be completed within 120 calendar days of the notice to proceed at the Fort Harrison VAMC facility located in Fort Harrison, Montana. The contractor will be responsible for complying with all infection control, safety, and environmental requirements outlined in the solicitation documents during the project period.
Notice text
5 versions
Update #5 · Latest ·
436-20-105 Bldg. 150 Sanitary Sewer Replacement at Fort Harrison VAMC
SDVOSB Set-aside
Due 10/20/22 11 AM via email to sylwia.zak@va.gov
Period of Performance is 120 days from NTP.
Update #4 ·
436-20-105 Bldg. 150 Sanitary Sewer Replacement at Fort Harrison VAMC SDVOSB Set-aside Due 10/20/22 11 AM via email to sylwia.zak@va.gov
Update #3 ·
436-20-105 Bldg. 150 Sanitary Sewer Replacement at Fort Harrison VAMC Due 9/27/22 11 AM via email to sylwia.zak@va.gov A site visit will be held on September 1, 2022 10am MT Administration Building 141, Conference Room 208 at Fort Harrison VAMC
Update #2 ·
436-20-105 Bldg. 150 Sanitary Sewer Replacement at Fort Harrison VAMC
Due 9/27/22 11 AM via email to sylwia.zak@va.gov
A site visit will be held on September 1, 2022 10am MT Administration Building 141, Conference Room 208 at Fort Harrison VAMC
Update #1 ·
Infection Control Risk Assessment 2.0 Matrix of Precautions for Construction, Renovation and Operations ©2022 American Society for Health Care Engineering of the American Hospital Association ***This document must be posted at the entrance of the construction site*** Name of Project: 436-20-105 BLDG 150 SANITARY SEWER REPLACEMENT Step One: Using Table 1, identify the Construction Project Activity Type (A-D). Table 1 - Construction Project Activity Type: Type C Type A Inspection and non-invasive activities. Includes but is not limited to: Removal of ceiling tile for visual inspection-limited to 1 tile per 50 square feet with limited exposure time. Limited building system maintenance (e.g., pneumatic tube station, HVAC system, fire suppression system, electrical and carpentry work to include painting without sanding) that does not create dust or debris. Clean plumbing activity limited in nature. Type B Small-scale, short duration activities that create minimal dust and debris. Includes but is not limited to: Work conducted above the ceiling (e.g., prolonged inspection or repair of firewalls and barriers, installation of conduit and/or cabling, and access to mechanical and/or electrical chase spaces). Fan shutdown/startup. Installation of electrical devices or new flooring that produces minimal dust and debris. The removal of drywall where minimal dust and debris is created. Controlled sanding activities (e.g., wet or dry sanding) that produce minimal dust and debris. Type C Large-scale, longer duration activities that create a moderate amount of dust and debris. Includes but is not limited to: Removal of preexisting floor covering, walls, casework or other building components. New drywall placement. Renovation work in a single room. Non-existing cable pathway or invasive electrical work above ceilings. The removal of drywall where a moderate amount of dust and debris is created. Dry sanding where a moderate amount of dust and debris is created. Work creating significant vibration and/or noise. Any activity that cannot be completed in a single work shift. Type D Major demolition and construction activities. Includes but is not limited to: Removal or replacement of building system component(s). Removal/installation of drywall partitions. Invasive large-scale new building construction. Renovation work in two or more rooms. Step Two: Using Table 2, identify the Patient Risk Group(s) that will be affected. If more than one risk group will be affected, select the higher risk group. Table 2 - Patient Risk Group: Low Risk Low Risk Non-patient care areas such as: Medium Risk Patient care support areas such as: High Risk Patient care areas such as: Highest Risk Procedural, invasive, sterile support and highly compromised patient care areas such as: Public hallways and gathering areas not on clinical units. Office areas not on clinical units. Breakrooms not on clinical units. Bathrooms or locker rooms not on clinical units. Mechanical rooms not on clinical units. EVS closets not on clinical units. · Waiting areas. Clinical engineering. Materials management. Sterile processing department - dirty side. Kitchen, cafeteria, gift shop, coffee shop, and food kiosks. Patient care rooms and areas All acute care units Emergency department Employee health Pharmacy - general work zone Medication rooms and clean utility rooms Imaging suites: diagnostic imaging Laboratory. · All transplant and intensive care units. All oncology units. OR theaters and restricted areas. Procedural suites. Pharmacy compounding. Sterile processing department - clean side. Transfusion services. Dedicated isolation wards/units. Imaging suites: invasive imaging. Step Three: Match the Patient Risk Group (Low, Medium, High, Highest) from Step Two with the planned Construction Activity Project Type (A, B, C, D) from Step One using Table 3 to find the Class of Precautions (I, II, III, IV or V) or level of infection control activities required. The activities are listed in Table 5 Minimum Required Infection Control Precautions by Class. Table 3 - Class of Precautions: Type C, Low Risk Class II Construction Project Type Patient Risk Group TYPE A TYPE B TYPE C TYPE D LOW Risk Group I II II III* MEDIUM Risk Group I II III* IV HIGH Risk Group I III IV V HIGHEST Risk Group III IV V V Infection control permit and approval will be required when Class of Precautions III (Type C) and all Class of Precautions IV or V are necessary. Environmental conditions that could affect human health, such as sewage, mold, asbestos, gray water and black water will require Class of Precautions IV for LOW and MEDIUM Risk Groups and Class of Precautions V for HIGH and HIGHEST Risk Groups. *Type C [Medium Risk groups] and Type D [Low Risk Groups] work areas [Class III precautions] that cannot be sealed and completely isolated from occupied patient care spaces should be elevated to include negative air exhaust requirements as listed in Class IV Precautions. Step Four: Assess potential risk to areas surrounding the project. Using Table 4, identify the surrounding areas that will be affected and the type of impact that will occur. If more than one risk group will be affected, select the higher risk group using Table 2 - Patient Risk Group. Table 4 - Surrounding Area Assessment Unit Below: n/a Unit Above: Kitchen Unit Lateral: n/a Unit Behind:Crawlspace Unit in Front: Exterior Risk Group: - Risk Group: Risk Group: - Risk Group: none Risk Group: none Contact: - Contact: Lisa Giese Contact: - Contact: Joe Bilodeau Contact: Joe Bilodeau Phone: - Phone: 406-447-6768 Phone: - Phone: 406-447-7383 Phone: 406-447-7383 Additional Controls: Noise Vibration Dust control Ventilation Pressurization Impact to other systems, such as: Data Mechanical Med Gases Water Systems Additional Controls: Noise Vibration Dust control Ventilation Pressurization Impact to other systems, such as: Data Mechanical Med Gases Water Systems Additional Controls: Noise Vibration Dust control Ventilation Pressurization Impact to other systems, such as: Data Mechanical Med Gases Water Systems Additional Controls: Noise Vibration Dust control Ventilation Pressurization Impact to other systems, such as: Data Mechanical Med Gases Water Systems Additional Controls: Noise Vibration Dust control Ventilation Pressurization Impact to other systems, such as: Data Mechanical Med Gases Water Systems Noise & Vibration Mitigation Strategies Use diamond drills instead of powder-actuated fasteners. Schedule noise-making periods with adjacent spaces. Use beam clamps instead of shot. Prefab where possible. Use tin snips to cut metal studs instead of using a chop saw. Install metal decking with vent tabs, then use cellular floor deck hangers. Consider pro-press instead of soldering, brazing or welding. Wet core drill instead of dry core or percussion. Instead of jackhammering concrete, use wet diamond saws. Use HEPA vacuums instead of standard wet/dry vacuums. Use mechanical joining system sprinkler fittings instead of threaded. Where fumes are tolerated, use chemical adhesive remover (flooring glue) instead of mechanical. To remove flooring, shot blast instead of using a floor scraper. Use electric sheers instead of reciprocating saw for ductwork cutting. Install exterior man/material lifts. Ventilation & Pressurization Mitigation Strategies HEPA 99.97% to exterior. Install temporary ductwork. Utilize temporary HVAC equipment. Vacate the area. Install temporary partitions. Use carbon filtration to filter odors. Impact to Other Systems Mitigation Strategies Schedule outages. Provide temporary systems Back-feed electricity or medical gases. Flushing and testing of building water systems. Infection Control Risk Assessment 2.0 Matrix of Precautions for Construction, Renovation and Operations ©2022 American Society for Health Care Engineering of the American Hospital Association Table 5 - Minimum Required Infection Control Precautions by Class | Before and During Work Activity: Type C, Low Risk Class II (from above classifications) Class of Precautions Mitigation Activities (Performed Before and During Work Activity) Class I Perform noninvasive work activity as to not block or interrupt patient care. Perform noninvasive work activities in areas that are not directly occupied with patients. Perform noninvasive work activity in a manner that does not create dust. Immediately replace any displaced ceiling tile before leaving the area and/or at end of noninvasive work activity. Class II Perform only limited dust work and/or activities designed for basic facilities and engineering work. Perform limited dust and invasive work following standing precautions procedures approved by the organization. This Class of Precautions must never be used for construction or renovation activities. Class III Provide active means to prevent airborne dust dispersion into the occupied areas. Means for controlling minimal dust dispersion may include hand-held HEPA vacuum devices, polyethylene plastic containment, or isolation of work area by closing room door. Remove or isolate return air diffusers to avoid dust from entering the HVAC system. Remove or isolate the supply air diffusers to avoid positive pressurization of the space, If work area is contained, then it must be neutrally to negatively pressurized at all times. *If negative pressure is required, refer to 8-11 guidance listed under Class IV precautions. Seal all doors with tape that will not leave residue Contain all trash and debris in the work area. Nonporous/smooth and cleanable containers (with a hard lid) must be used to transport trash and debris from the construction areas. These containers must be damp-wiped cleaned and free of visible dust/debris before leaving the contained work area. Install a sticky (dust collection) mat at entrance of contained work area based on facility policy. Sticky mats must be changed routinely and when visibly soiled. Maintain clean surroundings when area is not contained by damp mopping or HEPA vacuuming surfaces. Class IV Construct and complete critical barriers meeting NFPA 241 requirements. Barriers must extend to the ceiling or if ceiling tile is removed, to the deck above. All (plastic or hard) barrier construction activities must be completed in a manner that prevents dust release. Plastic barriers must be effectively affixed to ground and ceiling and secure from movement or damage. Apply tape that will not leave a residue to seal gaps between barriers, ceiling or floor. Seal all penetrations in containment barriers, including floors and ceiling, using approved materials (UL schedule firestop if applicable for barrier type). Containment units or environmental containment units (ECUs) approved for Class IV precautions in small areas totally contained by the unit and that has HEPA-filtered exhaust air. Remove or isolate return air diffusers to avoid dust entering the HVAC system. Remove or isolate the supply air diffusers to avoid positive pressurization of the space. Negative airflow pattern must be maintained from the entry point to the anteroom and into the construction area. The airflow must cascade from outside to inside the construction area. The entire construction area must remain negatively pressurized. Maintain negative pressurization of the entire workspace by use of HEPA exhaust air systems directed outdoors. Exhaust discharged directly to the outdoors that is 25 feet or greater from entrances, air intakes and windows does not require HEPA-filtered air. If exhaust is directed indoors, then the system must be HEPA filtered. Prior to start of work, HEPA filtration must be verified by particulate measurement as no less than 99.97% efficiency and must not alter or change airflow/pressure relationships in other areas. Exhaust into shared or recirculating HVAC systems, or other shared exhaust systems (e.g., bathroom exhaust) is not acceptable. Install device (e.g., magnehelic, manometer, or digital monitoring) on exterior of work containment to continually monitor negative pressurization. The ball in the wall or similar apparatus are not acceptable. Contain all trash and debris in the work area. Nonporous/smooth and cleanable containers (with a hard lid) must be used to transport trash and debris from the construction areas. These containers must be damp-wiped cleaned and free of visible dust/debris before leaving the contained work area. Worker clothing must be clean and free of visible dust before leaving the work area. HEPA vacuuming of clothing or use of cover suites is acceptable. Workers must wear shoe covers prior to entry into the work area. Shoe covers must be changed prior to exiting the anteroom to the occupied space (non-work area). Damaged shoe covers must be immediately changed. Install a sticky (dust collection) mat at entrance of contained work area based on facility policy. Sticky mats must be changed routinely and when visibly soiled. Consider collection of particulate data during work to monitor and ensure that contaminates do not enter the occupied spaces. Routine collection of particulate samples may be used to verify HEPA filtration efficiencies. Class V Construct and complete critical barriers meeting NFPA 241 requirements. Barriers must extend to the ceiling or if ceiling tile is removed, to the deck above. All (plastic or hard) barrier construction activities must be completed in a manner that prevents dust release. Plastic barriers must be effectively affixed to ground and ceiling and secure from movement or damage. Apply tape that will not leave a residue to seal gaps between barriers, ceiling or floor. Seal all penetrations in containment barriers, anteroom barriers, including floors and ceiling using approved materials (UL schedule firestop if applicable for barrier type). Construct anteroom large enough for equipment staging, cart cleaning, workers. The anteroom must be constructed adjacent to entrance of construction work area. Personnel will be required to wear coveralls at all times during Class V work activities. Coveralls must be removed before leaving the anteroom. Remove or isolate return air diffusers to avoid dust entering the HVAC system. Remove or isolate the supply air diffusers to avoid positive pressurization of the space. Negative airflow pattern must be maintained from the entry point to the anteroom and into the construction area. The airflow must cascade from outside to inside the construction area. The entire construction area must remain negatively pressurized. Maintain negative pressurization of the entire workspace using HEPA exhaust air systems directed outdoors. Exhaust discharged directly to the outdoors that is 25 feet or greater from entrances, air intakes and windows does not require HEPA-filtered air. If exhaust is directed indoors, then the system must be HEPA filtered. Prior to start of work, HEPA filtration must be verified by particulate measurement as no less than 99.97% efficiency and must not alter or change airflow/pressure relationships in other areas. Exhaust into shared or recirculating HVAC systems, or other shared exhaust systems (bathroom exhaust) is not acceptable. Install device (e.g., magnehelic, manometer, or digital monitoring) on exterior of work containment to continually monitor negative pressurization. The ball in the wall or similar apparatus are not acceptable. Contain all trash and debris in the work area. Nonporous/smooth and cleanable containers (with a hard lid) must be used to transport trash and debris from the construction areas. These containers must be damp-wiped cleaned and free of visible dust/debris before leaving the contained work area. Worker clothing must be clean and free of visible dust before leaving the work area anteroom. Workers must wear shoe covers prior to entry into the work area. Shoe covers must be changed prior to exiting the anteroom to the occupied space (non-work area). Damaged shoe covers must be immediately changed. Install a sticky (dust collection) mat at entrance of contained work area based on facility policy. Sticky mats must be changed routinely and when visibly soiled. Consider collection of particulate data during work to monitor and ensure that contaminates do not enter the occupied spaces. Routine collection of particulate samples may be used to verify HEPA filtration efficiencies. Table 6 - Minimum Required Infection Control Precautions | Upon Completion of Work Activity: Type C, Low Risk Class II (from above classifications) Class of Precautions Mitigation Activities (Performed upon Completion of Work Activity) Classes I, II and III Cleaning: Clean work areas including all environmental surfaces, high horizontal surfaces and flooring materials. Check all supply and return air registers for dust accumulation on upper surfaces as well as air diffuser surfaces. HVAC Systems: Remove isolation of HVAC system in areas where work is being performed. Verify that HVAC systems are clean and operational. Verify the HVAC systems meet original airflow and air exchange design specifications. Classes III, IV and V Class III (Type C Activities only), IV, and V precautions require inspection and documentation for downgraded ICRA precautions. Construction areas must be inspected by an infection preventionist or designee and engineering representative for discontinuation or downgrading of ICRA precautions. Work Area Cleaning: Clean work areas including all environmental surfaces, high horizontal surfaces and flooring materials. Check all supply and return air registers for dust accumulation on upper surfaces as well as air diffuser surfaces. Removal of Critical Barriers: Critical barriers must remain in place during all work involving drywall removal, creation of dust and activities beyond simple touch-up work. The barrier may NOT be removed until a work area cleaning has been performed. All (plastic or hard) barrier removal activities must be completed in a manner that prevents dust release. Use the following precautions when removing hard barriers: Carefully remove screws and painter tape. If dust will be generated during screw removal, use hand-held HEPA vacuum. Drywall cutting is prohibited during removal process. Clean all stud tracks with HEPA vacuum before removing outer hard barrier. Use a plastic barrier to enclose area if dust could be generated. Negative Air Requirements: The use of negative air must be designed to remove contaminates from the work area. Negative air devices must remain operational at all times and in place for a period after completion of dust creating activities to remove contaminants from the work area and before removal of critical barriers. HVAC systems: Upon removal of critical barriers, remove isolation of HVAC system in areas where work is being performed. Verify that HVAC systems are clean and operational. Verify the HVAC systems meets original airflow and air exchange design specifications. ©2022 The American Society for Health Care Engineering of the American Hospital Association Disclaimer: This document is provided by ASHE as a service to its members. The information provided may not apply to a reader s specific situation and is not a substitute for application of the reader s own independent judgment or the advice of a competent professional. ASHE does not make any guaranty or warranty as to the accuracy or completeness of any information contained in this document. ASHE and the authors disclaim liability for personal injury, property damage, or other damages of any kind, whether special, indirect, consequential, or compensatory, that may result directly or indirectly from use of or reliance on this document. Legionella Risk Assessment: TB Risk Assessment: (required per JC) ________________________ Infection Prevention ________________________ Contracting Officer s Representative (COR) Contact information: ________________________ Safety ________________________ Contract Company Supervisor Contact information:
Files
| File | Type | Posted |
|---|---|---|
| Bid Questions_VA Responses.docx | DOCX document | |
| 150 Structural.pdf | ||
| 36C25922R0096 0003.docx | DOCX document | |
| 436-20-105 Sanitary Sewer Site Visit Sign-in Sheet 2.pdf | ||
| 36C25922R0096 0002.docx | DOCX document | |
| S04 -Site Visit 2 Meeting Doc.docx | DOCX document | |
| S04 -Site Visit Meeting Doc.docx | DOCX document | |
| 36C25922R0096 0001.docx | DOCX document | |
| Past Performance Questionnaire.docx | DOCX document | |
| 436-20-105 Bldg 150 Sanitary Sewer Replacement_Pre-bid Site Visit Attendance_08242022.pdf | ||
| Asbestos Test_Building 150_01082022.pdf | ||
| Asbestos Test_Building 150_01122021.pdf | ||
| 36C25922R0096_1.docx | DOCX document | |
| CON 436-20-105 SPEC BLDG 150 SANITARY SEWER REPLACEMENT.pdf | ||
| CON 436-20-105 ICRA BLDG 150 SANITARY SEWER REPLACEMENT 02.docx | DOCX document | |
| CON 436-20-105 SCHEM BLDG 150 SANITARY SEWER REPLACEMENT.pdf |
Show all 16
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z2DA--436-20-105 Bldg. 150 Sanitary Sewer Replacement 436-C30123 | Award Notice | |
| This notice | Solicitation | |
| Z2DA--436-20-105 Bldg. 150 Sanitary Sewer Replacement | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| Z1ND--EL paso lift station piping repair | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ-- 658-23-108 Correct Stormwater Drainage | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--Renovate Space for Patient Care Improvements | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--CON-NRM-668-22-106 Correct Domestic Water System | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity