Z1DA--Replace Electrical Primary Distribution 515-15-117

Closed Solicitation Posted

Solicitation number
36C25025B0047
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 seeks replacement of the electrical primary distribution system at Battle Creek VA Medical Center in Battle Creek, Michigan, with sealed bids due August 6, 2026 at 1:00 PM EDT. This is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside; all bidders must be certified in the SBA Veteran Small Business Certification registry prior to bid submission and at award, or bids will be rejected.

Place of performance is 5500 Armstrong Road, Battle Creek, Michigan 49037. The project is NAICS 238210, Electrical Contractors and Other Wiring Installation Contractors, with a PSC code of Z1DA. The work scope includes demolition of existing electrical systems, excavation for duct banks and electrical equipment pads, installation of conduit in concrete-encased duct banks, switchgear and transformer installation, and related electrical infrastructure upgrades. Work must be completed within 500 calendar days from Notice to Proceed. The contractor must develop a Critical Path Method schedule within 10 days of Notice to Proceed and coordinate all activities with the Contracting Officer's Representative to maintain the facility's 24/7 operations, with normal work hours 7:00–18:00 and after-hours work 17:00–06:00 as coordinated.

The estimated contract value is between ten million and twenty million dollars. All applicable prevailing wage rates under Davis-Bacon Act Wage Determination MI20260079 apply, effective January 2, 2026. A 75% subcontracting limitation applies: the contractor cannot pay more than 75% of government-paid amounts to non-certified SDVOSB or Veteran-Owned Small Business firms (material costs excluded). Performance and payment bonds are required within 10 days of award. Contractors must submit an Experience Modification Rate certification, including three years of OSHA safety data, and acknowledge receipt of all solicitation amendments. FAR 52.222-90, addressing DEI discrimination compliance, applies and flows down to all subcontractors at any tier, except work performed outside the United States.

Notice text

2 versions

Update #2 · Latest ·

515-15-117

Update #1 ·

Page 2 of 2

515-15-117

Files

Show all 16

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
Z1DA--Replace Electrical Primary Distribution 515-15-117 Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Y1DZ--Brooklyn Upgrade Life Safety/Critical Branch Electrical Distribution Construction Brooklyn, New York 11209, United States · NAICS 238210 VA Technology Acquisition Center Total Small Business
C211--589A6-24-410, Replace MDP Panel Bld 89| EKH Dwight D. Enisenhower VA Medical Center Leavnworth Leavenworth Kansas 66048 · NAICS 238210 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business
Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. Richard L. Roudebush VA Medical Center 1481 W. 10th Street · NAICS 238210 Veterans Integrated Service Network 10 Service-Disabled Veteran-Owned Small Business
J061--Triennial Circuit Breaker and Feeder Testing Reno, Nevada 89502, United States · NAICS 238210 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland Department of Veterans Affairs Louis Stokes Cleveland VA Medical Center, Ohio 44106, United States · NAICS 238210 Veterans Integrated Service Network 10 Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity