Z1DA--Improve CLC and Facility Security 539-25-506
Closed Solicitation Posted
- Solicitation number
- 36C25025Q0554
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 is seeking complete construction services to improve security at the Cincinnati Veterans Affairs Medical Center through the installation of additional security cameras in Building 2 (Community Living Center) and Building 1. The project requires a contractor to provide all labor, materials, equipment, and supervision necessary to install nine Avigilon IP-based CCTV system cameras that will integrate with the existing facility infrastructure, with most cameras connecting via fiber optic cables to the Police Watch Office. Contractors must be Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) certified in the SBA database and comply with limitations on subcontracting, which restrict subcontracting to no more than 50% of services or 85% of general construction work. The project requires BICSI certified installers and a project superintendent, with specific technical requirements including CAT6A power over ethernet cables and integration with the existing Avigilon CCTV system. The solicitation amendment extended the proposal submission deadline to July 14, 2025, at 10:00 AM ET, with quotes to be submitted via email to the contracting officer.
This procurement is set aside specifically for Service-Disabled Veteran-Owned Small Businesses, with no incumbent contractor identified in the documentation. The contract value is estimated between $25,000 and $100,000 according to the initial RFP, though a separate justification document references an estimated value of approximately $250,000 for the Avigilon CCTV system devices. The project involves installing a total of nine security cameras across multiple locations, including six cameras in the CLC building's first floor, cameras in the Methadone Clinic area, and additional cameras in various hallway locations. The performance period is established at 90 days from Notice to Proceed, with work to be performed at the Cincinnati VA Medical Center campus. A site visit was conducted on June 18, 2025, and the project includes comprehensive specifications for electronic safety and security systems, requiring compliance with Davis-Bacon wage determinations for Hamilton County, Ohio construction trades.
Notice text
3 versions
Update #3 · Latest ·
Page 2 of 2
Q: The SOW 3.1.c.iii states to use 12 x 4 basket type cable tray for communication cables in corridors. Can we get updated drawings of where the cable trays are?
The SOW 4.1.a states that all new cameras must be tied into either directly or via an adjacent fiber patch panel in a nearby teledata closet. All new cameras will have to run fiber back to the switch
in the Police Watch Office.
Are these cameras to be installed with the use of fiber optic cable and not Cat 6 copper cable?
Can you call out which cameras can go to which teledata closets and which need to be run all the way to the Police Watch Office?
UPDATED ANSWER:
3.1 Contractor to verify.
1 We want these using standard CAT6A power over ethernet.
2 The camera in A731A will only run to A731. The 6 cameras in the (CLC) building 2 floor 1 will all run to 1144
teledata closet. The camera in A728D will run to B505G teledata closet. The camera in the hallway directly out
side of C3024 will run to (C176 Current / C1022 Future)(same location) in the primary care construction area.
Update #2 ·
Q&A
Q: Spec section 01 35 26 states the SSHO needs to be separate from the superintendent. Can this be change to where the superintendent can act as the SSHO. A separate SSHO will add considerable cost to the project.
A: I need both superintendent and a SSHO.
Q: Will a BICSI RCDD and BICSI certifies installers be required for this project?
A: 28 05 00 8
The Contractor shall provide proof project superintendent with BICSI Certified Commercial Installer Level 1, Level 2, or Technician to provide oversight of the project.
Q: The SOW 3.1.c.iii states to use 12 x 4 basket type cable tray for communication cables in corridors. Can we get updated drawings of where the cable trays are?
The SOW 4.1.a states that all new cameras must be tied into either directly or via an adjacent fiber patch panel in a nearby teledata closet. All new cameras will have to run fiber back to the switch in the Police Watch Office.
Are these cameras to be installed with the use of fiber optic cable and not Cat 6 copper cable?
Can you call out which cameras can go to which teledata closets and which need to be run all the way to the Police Watch Office?
A: 3.1 Contractor to verify.
1 Yes, we want these using Fiber Optic Cable.
2 All cameras will need to run to the police watch office besides the camera in A731A. This feed will only run to A731.
Update #1 ·
The chosen contractor shall provide complete construction services for labor, materials, equipment, and supervision required to complete the Improved CLC & Facility Security project for the Cincinnati VAMC, Cincinnati Campus. This project will install additional security cameras in building 2, the CLC, as well as building no. 1 at the Cincinnati VAMC.
Files
| File | Type | Posted |
|---|---|---|
| 36C25025Q0554 0002.docx | DOCX document | |
| Site visit sign in sheet 6.18.25.pdf | ||
| 36C25025Q0554 0001.docx | DOCX document | |
| ATTACHMENT VI - RFI FORM.docx | DOCX document | |
| ATTACHMENT III - DRAWINGS 5.27.pdf | ||
| ATTACHMENT I - JA.pdf | ||
| ATTACHMENT V- LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE.pdf | ||
| ATTACHMENT IV - SPECS COMBINED.pdf | ||
| ATTACHMENT II - DBA WD.pdf | ||
| 36C25025Q0554_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Z1DA--Improve CLC and Facility Security 539-25-506 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--Project No. 539-24-101 - Replace Failing Electrical Equipment. | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--AE Replace Roofing Cx - 539-25-101 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--AE Replace Roofing 539-25-101 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--AE Replace Elevators Cx 539-24-102 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--Construct Inpatient Tower 7th Floor, Cincinnati, OH | VA Technology Acquisition Center | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity