Z1DA--658-26-123 replace fire pump controller
Closed Solicitation Posted
- Solicitation number
- 36C24626Q0229
- Agency
- Veterans Integrated Service Network 6 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Points of contact
-
- Daniel Spaulding daniel.spaulding@va.gov (757) 728-7144
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Integrated Service Network 6 is procuring the replacement of a fire pump controller, jockey pump, and associated components in Building 143 at the Salem VA Medical Center in Salem, Virginia. The project is classified under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors) and PSC category Z1DA (Maintenance of Hospitals and Infirmaries). Key contract requirements include compliance with NFPA 20, NFPA 101, and VA safety standards, installation of a 60 horsepower, 460-volt fire pump controller with digital readouts, USB ports, surge arrestors, and remote monitoring capabilities, and a jockey pump rated for a minimum of 60 gallons per minute. Evaluation criteria focus on technical factors including equipment specifications, corporate experience, work plan, and safety record; past performance; and pricing. Critical deadlines include a mandatory site visit on December 29, 2025, technical questions due by December 30, 2025, and proposals due by January 16, 2026, at 5:30 PM EST.
This solicitation is designated as a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) with a size standard of $19.0 million in annual revenue, and no incumbent contractor is identified in the documentation. The contract will be awarded on a firm fixed-price basis to the most advantageous offeror, with the performance period estimated at 60 calendar days from February 9, 2026, to April 10, 2026, requiring all work to be completed within two consecutive shifts to accommodate fire watch requirements. Specific qualifications include demonstration of no more than three serious OSHA violations within the past three years and an Experience Modification Rate (EMR) of 1.0 or less. The work will take place at the Salem VA Medical Center located at 1970 Roanoke Boulevard in Salem, Virginia, a medical facility requiring strict compliance with safety, security, and environmental protocols as outlined in the comprehensive specification sections addressing waste management, quality control, safety requirements, and temporary environmental controls.
Notice text
4 versions
Update #4 · Latest ·
See attached SF30 Amendment 0003.
Update #3 ·
See attached SF30 Amendment 0002.
Update #2 ·
See attached Amendment 0001.
Update #1 ·
658-26-123 Replace Fire Pump Controller; See attached SF1442 solicitation. This project includes the replacement of the Fire Pump Controller, Jockey Pump, and associated components in Building 143 at the Salem VA Medical Center.
Attachments
| File | Type | Posted |
|---|---|---|
| 36C24626Q0229 0003.docx | DOCX document | |
| 36C24626Q0229 0002.docx | DOCX document | |
| 36C24626Q0229 0001.docx | DOCX document | |
| 658-26-123_Section 01 35 26 Safety Requirements.pdf | ||
| Attachment B - Salem VA Medical Center Map.pdf | ||
| Attachment A - DBA WD VA20250172 20250919.pdf | ||
| 658-26-123_Section 01 74 19 Const Waste Management.pdf | ||
| 658-26-123_01 45 00 Quality Control.pdf | ||
| 36C24626Q0229.docx | DOCX document | |
| 658-26-123_Section 01 57 19 Temp Enviro Controls.pdf | ||
| 658-26-123_Section 01 00 00 General Requirements.pdf |
Show all 11
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--658-26-123 replace fire pump controller | Solicitation | |
| Z1DA--658-26-123 replace fire pump controller | Pre-Solicitation |