Y1DA--Fire Damper Repairs Project

Closed Solicitation Posted

Solicitation number
36C24225R0036
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Department of Veterans Affairs 151 Knollcroft Rd. Lyons N.J. 07939, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is seeking a contractor to perform fire damper repairs at the Lyons VA Medical Center in New Jersey. The project involves inspecting and repairing fire damper deficiencies across four buildings, including replacing broken temperature links, springs, access doors, and addressing damaged dampers and linkages. Contractors must have at least 10 years of experience working with fire dampers and provide a full-time job foreman to oversee the project. The evaluation will be based on technical capability, price, and past performance, with contractors required to submit a maximum 5-page capability statement demonstrating relevant experience and trained personnel. Key dates include a site visit on January 29, 2025, questions due by February 3, 2025, and proposals due by February 7, 2025, at 12:00 PM Eastern Time.

The contract is exclusively set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238220 for Plumbing, Heating, and Air-Conditioning Contractors. The project involves repairing 33 total fire dampers across four buildings: Building 7 (12 dampers), Building 135 (3 dampers), Building 143 (9 dampers), and Building 57 (9 dampers), with 16 total air handlers. The contract has a magnitude of construction between $25,000-$100,000 and a $19 million size standard. Work must be performed during regular hours from Monday to Friday, 8 AM-4:30 PM, with a total performance period of 45 calendar days after receiving the notice to proceed. The place of performance is located at 151 Knollcroft Rd, Basking Ridge, New Jersey, and the contractor must adhere to VA, OSHA, and EPA safety policies throughout the project.

Notice text

2 versions

Update #2 · Latest ·

Amendment #1 to RFP 36C24225R0036

Update #1 ·

Please see attached solicitation and supporting documents.

Files

File Type Posted
36C24225R0036 0001.pdf PDF
36C24225R0036 0001_1.docx DOCX document
36C24225R0036_1.docx DOCX document
S02 - LIMITATIONS ON SUBCONTRACTING certificate s.pdf PDF
FAR 52.225-2 BUY AMERICAN CERTIFICATE.docx DOCX document
SOW fire dampers.docx DOCX document
36C24225R0036.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
H912--Fire Dampers Inspection and Testing Services NAICS 541350 Veterans Integrated Service Network 16 No set-aside
Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC Department of Veterans Affairs Franklin D. Roosevelt VA Medical Center Montrose, New York 10548, United States · NAICS 238210 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Y1DA--561-24-600 Upgrade Mechanical Systems-C Level Department of Veterans Affairs New Jersey VA Health Care System East Orange, New Jersey 07018, United States · NAICS 238220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Smoke barrier door replacement Northport, New York 11768, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Z1DA--Fix Legionella Deficiencies Construction 676-22-101 Tomah Vamc 500 East Veterans Street Tomah, Wisconsin 54660, United States · NAICS 238220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business