About this opportunity

The U.S. Coast Guard is seeking a contractor to relocate an existing well and install a chlorine injection system at Coast Guard Station Still Pond in Worton, Maryland. The project requires drilling a new well to 65 feet depth, connecting it to existing infrastructure, installing a submersible pump with electrical connections, sealing the old well, and implementing a chlorine injection system that maintains water quality standards with minimum total chlorine of 0.5 ppm and maximum residual disinfectant level of 4.0 ppm. Contractors must obtain all necessary permits and ensure compliance with federal, state, and local regulations. The government will use a Lowest Price Technically Acceptable (LPTA) evaluation methodology, requiring offerors to submit a five-page technical capabilities volume and a price volume using the provided Excel spreadsheet. Site visits are available from September 3-8, 2025, questions are due by September 10, 2025 at 12:00 PM EDT, and quote submissions must be received by September 12, 2025 at 12:00 PM EDT.

This solicitation does not utilize any set-aside designations and no incumbent contractors are identified in the documentation. While specific award values are not disclosed, the project falls under NAICS code 237110 for water and sewer line construction and requires completion within 21 days of contract acceptance. The work location is at U.S. Coast Guard Station Still Pond, 24192 Still Pond Road, Worton, Maryland 21678. The contract structure is a firm-fixed price purchase order with a total potential duration limited to five years including any option periods. Key personnel contacts include MK1 Shawn Gabert as the primary point of contact and MK1 Juan Caraballo as the Quality Assurance Evaluator Representative, with CWO2 Nicholas D. Johnson serving as the Environmental Protection Specialist.

Notice text

Relocate existing well to a position on property that meets all federal, state and local laws and install a chlorine injection, located at Station Still Pond U.S. Coast Guard 24192 Still Pond RD ,Worton, MD 21678.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Kelly Pierson OSS Shelton, Washington, United States · NAICS 237110 Indian Health Service Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors