W50S9J-24-B-0007 B109 Roof Replacement
Closed Solicitation Posted
- Solicitation number
- W50S9J-24-B-0007
- Agency
-
Army National Guard
Department of the Army, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238160 Roofing Contractors
- Place of performance
- Charleston, West Virginia 25311, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The federal contract opportunity is for the replacement of the roofing system on Building 109 of the West Virginia Air National Guard (ANG) facility located at Yeager Airport. The Department of the Army National Guard is the procuring agency. The work includes removing and replacing the existing EPDM roof membrane, insulation, flashing, penetrations, and accessories, and installing a new EPDM roof system with a 20-year manufacturer's warranty. The contractor must also remove and replace 12 skylights and install safety railings. Contractors must have a current NIST SP 800-171 DoD assessment posted in the Supplier Performance Risk System (SPRS) prior to contract award.
This solicitation is set aside for 100% Total Small Business. The government estimate for the project is between $203,058.40 and $235,882.20. Six offers were received, with bid prices ranging from $215,000 to $383,900. The work must be completed within 60 days after the Notice to Proceed is issued, and is located in Charleston, West Virginia.
Notice text
The proposed work on this project consists of replacing the roofing system of Building 109, of The West Virginia Air National Guard (ANG) at Yeager Airport. Reference attached Solicitation. Solicitations with Provision 252.204-7019, Notice of NIST SP 800-171 DoD Assessment Requirements NOV 2023 and then Awards with Clause 252.204-7020, must complete this assessment prior to award of contract. The contractor must have a current (no more than 3 years old) NIST SP 800-171 DoD assessment posted in SPRS. Please reference attached Solicitation and Drawings for specific details.
Files
| File | Type | Posted |
|---|---|---|
| Absract of Offers B7 B109 Roof Replacement2.pdf | ||
| Absract of Offers B7 B109 Roof Replacement.pdf | ||
| QandA 7172024.docx | DOCX document | |
| QandA 7102024.docx | DOCX document | |
| QandA.docx | DOCX document | |
| Amendment 0001.pdf | ||
| Attendance Sheet - Site Visit.pdf | ||
| Q and A B7.docx | DOCX document | |
| Solicitation.pdf | ||
| B109 Drawings.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| W50S9J-24-B-0007 B109 Roof Replacement | Pre-Solicitation | |
| W50S9J-24-B-0007 B109 Roof Replacement | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA-- 460-26-004 | Wilmington VAMC Roof Replacement | NCO 4 Construction East (VA-26-00029152) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| WWYK260004 - repair structural integrity, B1134, post 34 & north wall | Air Force Sustainment Center | Total Small Business | |
| SLV-CB pumping plant roof | Bureau of Reclamation | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity