Underground Storage Tank Inspection/Testing Services
Closed Solicitation Posted
- Solicitation number
- FA462625Q0011
- Agency
- Global Strike Command Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541990 All Other Professional, Scientific, and Technical Services
- PSC
- H399 Inspection- Miscellaneous
- Place of performance
- Malmstrom AFB, Montana 59402, United States
- Points of contact
-
- Joshua Crist joshua.crist.1@us.af.mil (406) 731-3624
- 1st Lt Randolph Foote randolph.foote.1@us.af.mil (406) 731-4476
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Global Strike Command is seeking a private third-party inspector to conduct underground storage tank (UST) compliance inspections and testing services at Malmstrom Air Force Base. The solicitation requires a contractor with Montana DEQ-licensed inspectors certified in Veeder-Root ATG systems to perform annual and triennial compliance inspections for 4 main base UST systems, 150 Missile Launch Facilities with 4,000-gallon diesel tanks, and 15 Missile Alert Facilities with 12,000-gallon tanks. Specific inspection requirements include sump tests, overfill tests, spill bucket leak tests, and cathodic protection testing using Montana-specific RP1200 testing forms. The contract will be awarded to the lowest-priced technically acceptable offer that meets all specifications, with offers due by February 25, 2025 at 12:00 PM. Evaluation will involve assessing offer completeness and conducting a price reasonableness analysis.
This is a total small business set-aside contract with a NAICS code 541990 and a size standard of $19.5 million. The period of performance includes a base period from March 3, 2025 to March 2, 2026, with four one-year option periods extending potential contract duration through March 2, 2030. Work will be performed at Malmstrom AFB facilities in the 10th, 12th, and 490th Missile Squadrons, covering a significant geographic area in central Montana. Contractors must comply with strict security protocols, including background checks, Entry Authority Lists, and mandatory government escorts when accessing missile facilities. The contract requires work to be completed within 90 days of inspection due dates, with normal work hours from 7:30 AM to 4:30 PM, excluding weekends and federal holidays.
Notice text
The purpose of this requirement is to have a private third-party inspector conduct underground storage tank (UST) compliance inspections/testing (triennial and annual) and walkthrough checklists at Malmstrom Air Force Base (MAFB) facilities in the 10th, 12th and 490th Missile Squadrons (MS) and on base in accordance with ARM 17.56 Underground Storage Tanks Petroleum and Chemical Substances and MCA Title 75, Chapter 11 Underground Storage Tanks in accordance with the Statement of Work (SOW).
Attachments
| File | Type | Posted |
|---|---|---|
| QA_FA4626-25-Q-0011.xlsx | XLSX spreadsheet | |
| 3 Attachment B Malmstrom AFB Monthly UST.pdf | ||
| 4 Attachment C Current Inspections Base and Missile Field.pdf | ||
| Solicitation - FA462625Q0011.pdf | ||
| 1 UST Inspections SOW.pdf | ||
| 5 Attachment D Map.pdf | ||
| 6 WD 2015-5391 Rev 23.pdf | ||
| 7 Offeror CEAL_Underground Storage Tanks.xlsx | XLSX spreadsheet | |
| 2 Attachment A Malmstrom AFB Annual UST.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Underground Storage Tank Inspection/Testing Services | Solicitation | |
| Underground Storage Tank Inspection/Testing Services | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity