3 Attachment B Malmstrom AFB Monthly UST.pdf

PDF 136 KB Posted

Attached to
Underground Storage Tank Inspection/Testing Services Federal contract opportunity
Solicitation number
FA462625Q0011
Issued by
Department of the Air Force Global Strike Command

About this file

This is a monthly tank assessment checklist form (341CES-500-1-UST-SF) for an underground storage tank at Malmstrom AFB. The form is designed to document inspections of a 12,000-gallon diesel fuel underground storage tank (Tank Real Prop ID: 465608) owned by the 341st Civil Engineer Squadron.

The checklist covers comprehensive inspection points including fire extinguisher maintenance, vent system conditions, pad/pavement integrity, safety conditions, spill response equipment, manhole covers, fill pipe components, containment sumps, drainage systems, release detection equipment, and record keeping requirements. Key inspection areas focus on ensuring proper tank operation and maintenance while preventing environmental and safety hazards through regular monitoring of components like spill prevention equipment, interstitial spaces, and release detection systems. The form indicates this is an official use document with all responses requiring "Yes," "No," or "N/A" selections along with space for comments on each inspection point.

View the file

Other files for this federal contract opportunity

Other files attached to Underground Storage Tank Inspection/Testing Services, newest first.
File Type Posted
QA_FA4626-25-Q-0011.xlsx XLSX spreadsheet
4 Attachment C Current Inspections Base and Missile Field.pdf PDF
Solicitation - FA462625Q0011.pdf PDF
1 UST Inspections SOW.pdf PDF
5 Attachment D Map.pdf PDF
6 WD 2015-5391 Rev 23.pdf PDF
7 Offeror CEAL_Underground Storage Tanks.xlsx XLSX spreadsheet
2 Attachment A Malmstrom AFB Annual UST.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

tankschedassessment.rpt

MONTHLY TANK ASSESSMENT CHECKLIST

341CES-500-1-UST-SF

2024/09/12 20:14 UTC

2000/01/01

12,000

Installation/GSU: Installation Date:

Owner: 465608Tank Real Prop ID:

Unit/Org: Supp Fac Real Prop ID:

Location: Designation: HFR - Underground

Model: Volume (Gallons):

Serial #:

MALMSTROM AFB

CC

0341 CIVIL ENGINEER SQ 0000

TANK 341CES-500-1-UST-SF

U-HFR-999000090568

07-08954 DIESEL FUELContents:

Finding Status:

Perform Date: Status:

Assessor: Duty Phone:

Comments:

Assessor Signature:

For Official Use Only

1. UST Monthly Walkthrough Checklist Review

2. Is the tank assessor/inspector conducting this inspection a qualified/trained operator?

Response: Yes No N/A

Comments:

2.02 UST Monthly Walkthrough Fire Extinguisher

5. Are fire extinguishers maintained in a serviceable condition and located in the designated area per NFPA 30 and 30A?

Response: Yes No N/A

Comments:

3.04 UST Monthly Walkthrough Venting

9. Is the normal vent located five feet or more from adjacent buildings and apart the required distance from an air intake?

Response: Yes No N/A

Comments:

10. Is the immediate surrounding area of the normal vent clear and free of obstructions?

Response: Yes No N/A

Comments:

11. Is the normal vent cap present and in good condition?

Response: Yes No N/A

Comments:

12. Is the normal vent riser solidly supported and standing vertical?

Response: Yes No N/A

Comments:

3.07 UST Monthly Walkthrough Pad

15. For tank pad and pavement: is concrete or asphalt over or near tank level with no significant cracks?

Response: Yes No N/A

Comments:

341CES-500-1-UST-SF

2024/09/12 20:14 UTCFor Official Use Only

3.07 UST Monthly Walkthrough Pad (continued)

16. Is the concrete cracking or settling over the top of the tank?

Response: Yes No N/A

Comments:

3.08 UST Monthly Walkthrough Safety

17. Are there other conditions that should be addressed for continued safe operation or that may affect the site spill prevention plan?

Response: Yes No N/A

Comments:

4.01 UST Monthly Walkthrough Spill Response

18. Are spill response kits properly supplied based on the product with absorbents, booms, PPE, etc. to properly contain/clean-up spillage from filling the tank?

Response: Yes No N/A

Comments:

4.04 UST Monthly Walkthrough Manhole

22. Are all manhole covers present, in good condition, seated firmly on the tank for the product type?

Response: Yes No N/A

Comments:

4.05 UST Monthly Walkthrough Spill Prevention

23. Visually check spill prevention equipment for damage and remove liquid or debris. (MDEQ, Q #1)

Response: Yes No N/A

Comments:

24. Is spill prevention equipment free of corrosion?

Response: Yes No N/A

Comments:

4.06 UST Monthly Walkthrough Fill Pipe

25. Check for and remove obstructions in the fill pipe. (MDEQ, Q #2)

Response: Yes No N/A

Comments:

26. Check the fill pipe cap to make sure it fits securely on the fill pipe. (MDEQ, Q #3)

Response: Yes No N/A

Comments:

27. Does the fill cap assembly (i.e., brass coupler and swivel) function properly before, during and after deliveries from any damage?

Response: Yes No N/A

Comments:

5.01 UST Monthly Walkthrough Containment Sumps

28. For double-walled spill prevention equipment with interstitial monitoring, check for leaks in the interstitial area. (MDEQ #4)

341CES-500-1-UST-SF

2024/09/12 20:14 UTCFor Official Use Only

5.01 UST Monthly Walkthrough Containment Sumps (continued)

29. Are spill buckets and containment sumps (integrity) free of vegetation, holes, cracks, bulges, corrosion, fire hazards and damage?

Response: Yes No N/A

Comments:

30. Are containment sumps (or manholes) free of water, product and debris?

Response: Yes No N/A

Comments:

5.02 UST Monthly Walkthrough Drainage

31. Does the surface water drainage system allow water to accumulate in a low spot, on top of the tank ?

Response: Yes No N/A

Comments:

5.04 UST Monthly Walkthrough Containment Drain Valves

33. Are the drain valves on the spill containment sump on the fill pipe operable and closed?

Response: Yes No N/A

Comments:

6.01 UST Monthly Walkthrough Release Detection

36. Ensure records of release detection testing are reviewed and current. (MDEQ, Q #6)

Response: Yes No N/A

Comments:

37. Have copies of passing release detection reports (i.e., leak detection test report) been obtained, for piping system(s), to meet record keeping and compliance requirements?

Response: Yes No N/A

Comments:

6.05 UST Monthly Walkthrough Wet Interstice

43. For double-walled, is the level of brine or monitoring fluid within normal range with no alarms?

Response: Yes No N/A

Comments:

6.06 UST Monthly Walkthrough RD Equipment (Tank)

44. Is the tank release detection equipment operating properly to determine usual operating conditions (i.e., faulty alarms, monitoring discrepancies, readings, etc.)?

Response: Yes No N/A

Comments:

6.08 UST Monthly Walkthrough RD Equipment (General)

46. Check release detection equipment to make sure the release detection equipment is operating with no alarms or other unusual operating conditions present. (MDEQ, Q #5)

Response: Yes No N/A

9. UST Monthly Walkthrough Reporting and Record Keeping

341CES-500-1-UST-SF

2024/09/12 20:14 UTCFor Official Use Only

9. UST Monthly Walkthrough Reporting and Record Keeping (continued)

60. Is reporting being conducted to the appropriate agency and recordkeeping being maintained of required documentation? (40 CFR 280.34)

Response: Yes No N/A

Comments:

10. UST Monthly Walkthrough Miscellaneous

62. Has an AF Form 332 been completed or electronic equivalent and submitted for any deficiencies observed? (Answer "no" if no deficiencies requiring a work request were noted)

Response: Yes No N/A

Comments:

63. If required, have all other Service, Local, State, or Federal requirements checklist(s) been accomplished, and documents uploaded/linked to this tank assessment record?

File details come from the government source that posted it. Updated .