J012--Dry-Type Fire Suppression System
Open Pre-Solicitation Posted
Not the latest version. See the latest pre-solicitation from .
- Solicitation number
- 36C26127Q0169
- Agency
-
Veterans Integrated Service Network 21
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Place of performance
- VA Palo Alto Health Care System Palo Alto CA 94304, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 is issuing a sources sought announcement for dry-type fire suppression system maintenance services, with responses due November 30, 2026. No solicitation is available, and the Government retains discretion over procurement strategy based on the responses. The Set Aside line reads "No Set-Aside Used." The requirement carries NAICS 811310 with a $12.5 million size standard and PSC J012 (maintenance, repair, and rebuild of fire control equipment). Offerors must be registered in SAM with current Online Representations and Certifications on file and should confirm that their SAM profile lists NAICS 811310. As a service acquisition, the Limitations on Subcontracting requirement applies to all small businesses, including SDVOSBs and VOSBs: they may not pay more than 50 percent of the Government's payment for performance to subcontractors that are not similarly situated entities.
The attached inventory, identified in the source as the solicitation reference 36C26127Q0169 package, covers grease hood systems, exhaust fans, hazmat storage containers, and fire suppression systems at VA locations in Palo Alto, Menlo Park, and Livermore. Fire suppression equipment includes Pyro Chem, Ansul, Kidde IND-21, and FIKE Cheetah-XI/HFC-125 systems. Grease hoods and exhaust fans require semi-annual or quarterly service, and fire suppression systems require semi-annual or annual testing. Certification testing requires alarm de-activation and electrical breaker box keys for Gaylord units. Canteen work must occur after hours at Palo Alto Building 101 (after 5pm), Menlo Park Building 334 (after 3pm), Palo Alto Building 100 (after 6pm), and Livermore Building 329 (after 7pm).
The announcement provides no award value, period of performance, or incumbent. Responses are not compensated and are used solely within the VA.
Notice text
THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY.
No Solicitation is currently available.
All information contained in this Sources Sought Announcement is preliminary, as well as subject to modification, and is in no way binding on the Government. The Government will not pay for any information submitted in response to this request. The information requested will be used solely within the Department of Veterans Affairs to facilitate decision making and will not be disclosed outside of the Government. The determination of a procurement strategy, based upon the comments submitted in response to this Sources Sought Announcement, is solely within the discretion of the Government.
Potential Offerors must be registered in the System for Award Management (SAM) to be eligible for an award (See Internet Site https://www.sam.gov/portal/public/SAM/). Potential Offerors must also have a current Online Representations and Certification Application on file with SAM.
The applicable North American Industry Classification System (NAICS) Code is 811310, Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance and size standard is $12.5 million. NOTE: Please ensure that System For Award Management (SAM) indicates this NAICS code if you are interested in the requirement.
Before responding please carefully read and consider the following:
As this is a service acquisition, the Small Business Administration and the Federal Acquisition Regulation have a Limitations on Subcontracting requirement. For all small businesses, to include SDVOSB and VOSB, it will not pay more than 50 percent of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract. See FAR 52.219-14 and FAR 52.219-27 available in full text at https://www.acquisition.gov/far/html/52_217_221.html
Brief Description of Services
The VA Palo Alto Health Care System (VAPAHCS) has a requirement for Dry-type fire suppression system maintenance and testing of Grease hoods, exhaust fans and chemical Hazmat Sheds. The Government is seeking only qualified kitchen exhaust cleaning specialists who hold current certification through the International Kitchen Exhaust Cleaning Association (IKECA) or an equivalent recognized industry association. Vendors must provide documentation demonstrating compliance with applicable NFPA standards, including NFPA 72 and 96, and furnish all required qualifications, training records, and certifications for personnel performing kitchen exhaust and grease hood cleaning services.
General
This is a non-personal services contract to provide Dry-Type Fire Suppression System services for the VA Palo Alto Health Care System (VAPAHCS). The Government shall not exercise any supervision or control over the contract service providers performing the services herein. Such contract service providers shall be accountable solely to the Contractor who, in turn is responsible to the Government.
Place of Performance:
Palo Alto Main Campus
3801 Miranda Ave.
Palo Alto, CA 94304
Menlo Park Medical Center
795 Willow Rd.
Menlo Park, CA 94025
Livermore Medical Center
4951 Arroyo Rd.
Livermore, CA 94550
Contractor Qualifications:
Contractor shall possess a California C-16 contractor license and be certified by the system manufacturer to service and repair Ansul and related Automatic Fire Control Systems, or provide documentation of equivalent system training. Grease hood cleaning shall be performed by International Kitchen Exhaust Cleaning Association (IKECA)-certified or equivalent association Certified Exhaust Cleaning Specialists (CECS), or personnel who can document compliance with all applicable NFPA 72 and NFPA 96 grease hood cleaning qualification and certification requirements. The Government reserves the right to request and review such licenses, certifications, and supporting documentation at any time during the contract period.
Preventative Maintenance and Testing
Contractor shall provide all tools, materials, equipment, labor, and transportation to perform annual and semi-annual cleaning and fire protection services/ certification of the following grease hoods, exhaust fans, and chemical storage sheds at three divisions of the Veterans Administration Palo Alto Health Care System (VAPAHCS). All cleaning shall be done in accordance with NFPA 96 latest edition. All fire protection service/inspections and certifications shall be performed per NFPA 17A, 96, 10 and 72 latest editions.
Capability Statement
The Government requests that only firms seriously interested and truly capable should send their capability information to the Contracting Officer, Kulvinder Brar by email at: Kulvinder.brar@va.gov no later than 3:00 PM Pacific Time, November 30, 2026:
(a)Â Business Size (Large/Small)
(b)Â Business Socio-Economic Status (SDVOSB, WOSB, 8(a), HUBZone, etc.)
(c) SAM record (www.sam.gov)
(d) VIP record (SDVOSB/VOSB firms only) (https://www.vip.vetbiz.gov/)
(e)Â DUNS number
(f) Ability and experience in managing similar projects. Include general information and technical background describing your firm's experience on contracts requiring similar efforts to meet the program objectives.
(g) List of Projects (Government and Commercial) that are similar in scope and size.
(h) Anticipated Teaming Arrangements (if any)
(i) GSA Contract Number if applicable.
(j) Copies of certificates/licenses as identified above under Contractor Qualifications
Interested parties shall not submit more than 10 single-sided, type-written pages using 12-point font or larger. Published literature may be any number of pages.
The Government will use this information when determining its business type decision. Â Â Â Â
*Failure to provide the information requested above (items (a) (j)) will be considered non-responsive and will not be considered a viable source.
DISCLAIMER
This Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly. The Government will not compensate an offeror for providing information in response to this sources sought. Furthermore, the Government reserves the right to cancel this requirement at its discretion. This is simply a sources sought notice.
   Â
Files
| File | Type | Posted |
|---|---|---|
| Grease Hood-HAZMAT shed inventory-Schedule- bldg plans 7-24-206.pdf | ||
| 36C26127Q0169.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| J012--Dry-Type Fire Suppression System | Pre-Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J012--Fire Suppression System Maintenance and | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| J012--Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service | Veterans Integrated Service Network 16 | No set-aside | |
| Northern California Area Office (NCAO) Fire Alarm | — | Service-Disabled Veteran-Owned Small Business | |
| H961--Tri-Annual Electrical Inspection | Veterans Integrated Service Network 21 | Total Small Business | |
| CTX Life Safety Assessment and Fire Damper Inspection | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity