RFQ for one (1) Tunable Laser Multi-Photon Microsc
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 75N98026Q00462
- Agency
- Office of Logisitics and Acquisition Operations National Institutes of Health, Department of Health and Human Services
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 Laboratory Equipment And Supplies
- Points of contact
-
- Brittany N May brittany.may@nih.gov
Notice details come from SAM.gov. Updated .
About this opportunity
The National Institute of Mental Health, part of the National Institutes of Health, is soliciting quotations for one tunable laser multi-photon microscope for shared research use, with proposals due June 12, 2026. This is an unrestricted, competitive acquisition not expected to exceed the simplified acquisition threshold, conducted as a commercial item purchase under FAR 12.603.
Place of performance is the Systems Neurodevelopment Laboratory at NIMH. The microscope must deliver a gap-free tuning range of 680 nm to 1300 nm with optimized performance in the 900–1100 nm range, dual output capability (tunable main output and fixed 1045 nm beam), minimum average power levels ranging from greater than 1.4W to greater than 3.0W depending on wavelength, pulse widths less than 120fs/170fs, integrated dispersion compensation, and integrated attenuators. The equipment enables monitoring and manipulation of large neuronal populations at single-cell resolution, supporting multiple fluorescent indicators and wavelength-sensitive stimulation options with greater tissue penetration.
NAICS code is 334516, Analytical Laboratory Instrument Manufacturing; PSC is 6640, Laboratory Equipment and Supplies. Size standard for this NAICS is 1,000 employees.
Notice text
NIMH: Supply: Diagnostic Laboratory Equipment: N/A
For shared use allowing monitoring and manipulation large neonural populations at a single-cell resolution, giving the lab greater versatility in experiments, greater penetration of tissue, use of multiple fluorescent indicators, and stimulation of different wavelength-sensitive options.
Attachments
| File | Type | Posted |
|---|---|---|
| Sol_75N98026Q00462.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| RFQ for One (1) Tunable Laser Multi-Photon Microsc | Award Notice | |
| RFQ for one (1) Tunable Laser Multi-Photon Microsc | Solicitation |