Replace Peachtree Summit Federal Building Fire Alarm Design/Build
Closed Solicitation Posted
- Solicitation number
- 47PE0321R00006
- Agency
-
Region 4
Public Buildings Service, General Services Administration
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Z1AA Maintenance Of Office Buildings
- Place of performance
- Atlanta, Georgia 30306, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The General Services Administration seeks to replace the fire alarm system at the Peachtree Summit Federal Building in Atlanta, Georgia through a design-build contract. The selected contractor shall remove the existing system and design and install a new fully addressable, non-proprietary and open source fire protection system serving the entire building. Proposals are due by contacting the contracting officer, Joseph Ardoin III, by specified dates. The agency will evaluate proposals using a lowest price technically acceptable methodology. Interested parties must provide a 20% bid bond and the awardee must furnish a $5 million performance bond.
This requirement is set aside as a total small business solicitation. The project involves NAICS codes 541330, 238210, and PSC J065. The estimated value is between $1 million to $5 million, and the place of performance is the Peachtree Summit Federal Building located at 401 W. Peachtree Street NW in Atlanta, Georgia. The period of performance is from April 2022 through April 2023. The successful offeror must complete all work while coordinating with the occupied building according to an approved phasing plan.
Notice text
The General Service Administration (GSA), Public Building Service (PBS), R04 intends to issue a Request for Proposal as a Total Small Business Set-aside under the authority of FAR 19.502 – Setting Aside Acquisitions and FAR 19.10 – Small Business Competitiveness Program. This requirement is for the replacement of the existing Fire Alarm System in the Peachtree Summit Federal Building located in Downtown Atlanta, GA. All responsible sources may submit a response which shall be considered by the agency if timely received by the point of contact described herein.
Bid Bond is requied and should be 20 Percent of Proposal Total Costs.
Performance Bond will be required in the amount of $5 Million.
Order of Magnatude for Project is from $1 Million to $5 Million.
The project will include a full Fire Alarm System Replacement, and will include, but shall not be limited to, the removal of the existing fire alarm system and the design and installation of a new fully addressable non-proprietary, open source FPS, to include GUI programming which will serve the entire building.
Please contact the Contracting Officer for access to building Blue Prints and Drawings.
Point of Contact - Joseph Ardoin III, Contracting Officer, General Services Administration (4P1QG), 77 Forsyth St. SW, Atlanta, GA 30303; Phone: (404) 772-8076.
Place of Performance - Peachtree Summit Federal Building
Building Manager: Eric Anthony - 401 W. Peachtree Street NW; Atlanta, GA 30308
If you have any questions or concerns, please call or email Joseph Ardoin III at joseph.ardoin@gsa.gov.
Files
Show all 13
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Replace Peachtree Summit Federal Building Fire Alarm Design/Build | Special Notice | |
| Replace Peachtree Summit Federal Building Fire Alarm Design/Build | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| SACN Replace Fire Alarms and Intrusions Systems | — | Total Small Business | |
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity