REPLACE HVAC UNITS Building 7050
Closed Solicitation Posted
A later notice was posted. The latest for this opportunity is the Limited / Sole Source Justification from . See the latest notice
- Solicitation number
- W91151-21-B-0003
- Agency
- MICC Fort Hood Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- Z1AA Maintenance Of Office Buildings
- Place of performance
- Fort Hood TX 76544, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks to replace HVAC units and upgrade the chilled water system at Building 7050 on Fort Hood, Texas for the Department of the Army Materiel Command Mission and Installation Contracting Command. The project includes replacing nine existing air handlers with one new air-cooled chiller, two pumps, and associated piping accessories. Offerors must be licensed, certified small businesses and able to complete the work within 240 calendar days. Questions were due by April 19th and responses were provided by amendment on April 26th. Proposals are due by 2:00 PM on May 6th and will be evaluated based on technical qualifications and price.
The solicitation is set aside as a 100% small business contract under NAICS 238220 for plumbing, heating, and air conditioning contractors. The estimated value is between $500,000 and $1,000,000 to be awarded as a firm fixed-price contract. The place of performance is Building 7050 at Fort Hood, Texas. Respondents must have three years of relevant experience and the work must be completed within 240 calendar days of award or liquidated damages will be assessed.
Notice text
The purpose of this project is to upgrade the chilled-water system at building 7050 and replace nine existing air handlers. The existing system consists of two water-cooled chillers, two cooling towers, and five pumps, which shall be replaced with one air-cooled chiller and two pumps. Work shall also include replacing several existing piping accessories, balancing existing air devices, and modifying existing HVAC controls.
Attachments
Show all 11
Notice history
| Notice | Type | Posted |
|---|---|---|
| REPLACE HVAC UNITS Building 7050 | Limited / Sole Source Justification | |
| REPLACE HVAC UNITS Building 7050 | Solicitation | |
| REPLACE HVAC UNITS Building 7050 | Pre-Solicitation | |
| REPLACE HVAC UNITS Building 7050 | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities