REPLACE HVAC UNITS Building 7050
Closed Pre-Solicitation Posted
A newer solicitation was posted. See the latest solicitation from .
- Solicitation number
- W91151-21-B-0003
- Agency
- MICC Fort Hood Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- Not on record
- Place of performance
- Fort Hood TX 76544 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice seeks information from small businesses for a planned solicitation by the Mission and Installation Contracting Command Fort Hood to replace HVAC units in Building 7050 at Fort Hood, Texas. The project scope involves upgrading the chilled water system and replacing nine air handlers at a magnitude between $500,000 and $1,000,000. Interested parties must be licensed and experienced in HVAC, electrical, plumbing and construction work. Responses are requested to include company and licensing details, socioeconomic status, bonding and insurance information, project scheduling expertise, and three references. The deadline to respond is January 22, 2021.
No set-aside designation is specified. The anticipated NAICS code is 238220 for plumbing, heating, and air conditioning contractors. The pre-solicitation seeks information on potential small business sources to determine adequate competition for the requirement. The project involves replacing nine existing air handlers by installing one air-cooled chiller and two pumps, along with associated piping, balancing, and control work. System for Award Management registration is also required to be eligible for consideration.
Notice text
Sources Sought Synopsis
Synopsis: REPLACE HVAC UNITS Building 7050, Fort Hood TX, 76544
The purpose of this sources sought is to gain knowledge of the potential interested small business sources for this project, the Government is considering a set aside for Socio-economic status. This notice is for planning purposes only. All interested parties should respond. MICC-FH, may issue a solicitation and award of a contract to “Replace HVAC Units in Building 7050”. The magnitude of this project is between “$500,000 and $1,000,000”. The anticipated NAICS code(s) is NAICS Code 238220 – Plumbing, Heating, and Air-Conditioning Contractors and standard business size is $16,500,000 million.
Description of project is as follows: The purpose of this project is to upgrade the chilled-water system at building 7050 and replace nine existing air handlers. The existing system consists of two water-cooled chillers, two cooling towers, and five pumps, which shall be replaced with one air-cooled chiller and two pumps. Work shall also include replacing several existing piping accessories, balancing existing air devices, and modifying existing HVAC controls. All work shall comply with all State, Local and Federal laws and regulations, industry and construction codes and standards, manufacturer’s specifications and recommendations, and all contract special provisions, terms and conditions. The Contractor shall be responsible for obtaining all required licenses and permits to perform construction work on a Federal installation, be properly bonded and insured in accordance with FAR requirements.
This is only the market research phase of this requirement. By no means does this sources sought mean that the Government will enter into an agreement with your agency. The Government is trying to determine if there is adequate competition in order to compete this requirement. If you are a small business and you are interested in competing in this requirement please reply to this sources sought and respond to the following questions by Friday January 22, 2021 at 2:00 P.M. Please submit via e-mail to Sonja Fields at Sonja.s.fields.civ@mail.mil, (254) 287-1581. REF NO: W91151-21-B-0003
SUBMISSION DETAILS/INFORMATION SOUGHT BY THE GOVERNMENT:
Responses must include the following:
1. Company Information
a. Company Name
b. Address
c. Points of Contact
d. Telephone Numbers
e. E-mail address
2. Are you licensed for HVAC, Master Electrician, Master Plumber and all other trades for this requirement which requires 3 year experience on similar jobs?
3. Socio-economic status for the listed NAICS code please select all that applies:
____ Large Business
____ Small Business
____ Small Disadvantage Business
____ HubZone Business
____ 8(a) Program participant
____ Woman-Owned Business
____ Service-Disable Veteran-Owen Small Business (SDVOSB)
4. What is your bonding capability and limits?
5. Would you consider work on Fort Hood which includes the Wage Determination Act policies and guidelines?
6. Are you familiar with Gannt Charts or similar Project Scheduling programs and their purpose?
7. Please attach 3 references for similar work that your company has performed.
8. How long have you been doing business renovating and repurposing buildings?
9. Is your company name and address registered in System for Award Management (SAM)?
The firm must be registered in System for Award Management (SAM) http://www.sam.gov/portal/public/SAM/, with the socio-economic status NAICS codes specified in the information Contractor provides in response to this Source Sought.
This notice is issued solely for information and planning purposes - it does not constitute an Invitation for Bid (IFB) or a promise to issue an IFB in the future. This notice does not commit the U.S. Government to contract for any supply or service. Further, the U.S. Government is not seeking quotes, bids or proposals at this time and will not accept unsolicited proposals in response to this sources sought notice. The U.S. Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future IFB, if any is issued. If a solicitation is released, it will be synopsized on the Government wide Point of Entry (Federal Business Opportunities (FedBidOpps – https://www.fbo.gov). It is the responsibility of potential offerors to monitor the Government wide Point of Entry for additional information pertaining to this requirement.
Attachments
| File | Type | Posted |
|---|---|---|
| Sources Sought Synopsis W91151-21-B-0003 Replace HVAC Units in BLDG 7050 15 Jan 2021.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| REPLACE HVAC UNITS Building 7050 | Limited / Sole Source Justification | |
| REPLACE HVAC UNITS Building 7050 | Solicitation | |
| REPLACE HVAC UNITS Building 7050 | Pre-Solicitation | |
| REPLACE HVAC UNITS Building 7050 | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity