Repair - Upgrade Fire Protection Systems B6205
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- FA301624Q0041
- Agency
-
Air Education and Training Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541370 Surveying and Mapping (except Geophysical) Services
- Place of performance
- Jbsa Lackland, Texas 78236, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This federal contract opportunity seeks proposals to evaluate and repair the fire protection systems at Building B6205 on Camp Bullis in San Antonio, Texas. The Department of the Air Force Air Education and Training Command is soliciting quotes for these services, which include inspecting the sprinkler and alarm systems, providing hydraulic calculations, conducting a dust hazard analysis, preparing hazardous material inventories and management plans, and coordinating a fire flow test. Offerors must deliver comprehensive reports with findings and upgrade recommendations. Quotes are due by March 22, 2024, and any questions must be submitted in writing by March 18.
The solicitation is a 100% Small Business Set-Aside with a NAICS code of 541370 and a size standard of $19 million. The period of performance is 45 calendar days from date of award, and award will be made to the responsible vendor with the lowest evaluated price among technically acceptable proposals. The work is to be performed at Building B6205 in San Antonio, Texas.
Notice text
4 versions
Update #4 · Latest ·
AMENDMENT 3- The RFQ has been amended to change the period of performance.
AMENDMENT 2- The RFQ has been amended to change the NAICS, PSC, SOW, due date and CLIN description.
AMENDMENT 1- The RFQ has been amended to incorporate the Wage Determination attachment.
A licensed Fire Protection Engineer (FPE) will evaluate and asses B6205 existing fire system compatibility to accommodate the new woodshop. This includes inspecting sprinkler and alarm systems, providing hydraulic calculations, conducting a dust hazard analysis, and coordinating a fire flow test with American Water. The contractor shall deliver comprehensive reports and recommendations to bring the building up to code according to NFPA standards based on findings.
If interested and capable of fulfilling the requirements listed in the statement of work (SOW) please complete the attached RFQ and return to me no later than suspense date NLT 10 April 2024 at 10am. If any questions please have the attached with your RFQ NLT 4 April 2024 at 10am.
Please refer to the following attachement for all pertinent information:
1. RFQ Document
2. SOW
3. Reference pictures
Any interested party may inquire with the below point of contact:
Amn Larissa Showers, Contract Specialist,
Email: Larissa.showers.br@us.af.mil
Update #3 ·
AMENDMENT 2- The RFQ has been amended to change the NAICS, PSC, SOW, due date and CLIN description.
AMENDMENT 1- The RFQ has been amended to incorporate the Wage Determination attachment.
A licensed Fire Protection Engineer (FPE) will evaluate and asses B6205 existing fire system compatibility to accommodate the new woodshop. This includes inspecting sprinkler and alarm systems, providing hydraulic calculations, conducting a dust hazard analysis, and coordinating a fire flow test with American Water. The contractor shall deliver comprehensive reports and recommendations to bring the building up to code according to NFPA standards based on findings.
If interested and capable of fulfilling the requirements listed in the statement of work (SOW) please complete the attached RFQ and return to me no later than suspense date NLT 10 April 2024 at 10am. If any questions please have the attached with your RFQ NLT 4 April 2024 at 10am.
Please refer to the following attachement for all pertinent information:
1. RFQ Document
2. SOW
3. Reference pictures
Any interested party may inquire with the below point of contact:
Amn Larissa Showers, Contract Specialist,
Email: Larissa.showers.br@us.af.mil
Update #2 ·
AMENDMENT 1- The RFQ has been amended to incorporate the Wage Determination attachment.
Description of Service: Evaluate the existing fire system for B6205’s compatibility with the new woodshop. This includes inspecting sprinkler and alarm systems, providing hydraulic calculations, conducting a dust hazard analysis, preparing a hazardous material inventory statement, developing a hazardous material management plan, and coordinating a fire flow test with American Water. Deliver comprehensive reports and recommendations based on findings.
If interested and capable of fulfilling the requirements listed in the statement of work (SOW) please complete the attached RFQ and return to me no later than suspense date NLT 22 March 2024 at 10am. If any questions please have the attached with your RFQ NLT 18 March 2024 at 10am.
Please refer to the following attachement for all pertinent information:
1. RFQ Document
2. SOW
3. Reference pictures
Any interested party may inquire with the below point of contact:
Amn Larissa Showers, Contract Specialist,
Email: Larissa.showers.br@us.af.mil
Update #1 ·
Description of Service: Evaluate the existing fire system for B6205’s compatibility with the new woodshop. This includes inspecting sprinkler and alarm systems, providing hydraulic calculations, conducting a dust hazard analysis, preparing a hazardous material inventory statement, developing a hazardous material management plan, and coordinating a fire flow test with American Water. Deliver comprehensive reports and recommendations based on findings.
If interested and capable of fulfilling the requirements listed in the statement of work (SOW) please complete the attached RFQ and return to me no later than suspense date NLT 22 March 2024 at 10am. If any questions please have the attached with your RFQ NLT 18 March 2024 at 10am.
Please refer to the following attachement for all pertinent information:
1. RFQ Document
2. SOW
3. Reference pictures
Any interested party may inquire with the below point of contact:
Amn Larissa Showers, Contract Specialist,
Email: Larissa.showers.br@us.af.mil
Files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment 3 Final- FA301624Q00410003.pdf | ||
| CAMP BULLIS B6205 SOW 26 Mar 2024.docx | DOCX document | |
| Final Solicitation Amendment - FA301624Q00410002.pdf | ||
| Attachment 3- Wage Determination 2015-5253 REV.22.txt | TXT text file | |
| Solicitation Amendment 1 - FA301624Q00410001.pdf | ||
| Final RFQ - FA301624Q0041.pdf | ||
| Attach 1 CAMP BULLIS B6205 SOW 06 Feb 24.docx | DOCX document | |
| Attach 2 Reference pictures.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Repair - Upgrade Fire Protection Systems B6205 | Award Notice | |
| This notice | Solicitation | |
| Repair - Upgrade Fire Protection Systems B6205 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Inspection of Fire Extinguishers and Suppression Systems for AMXG at Hill AFB, Utah | Air Force Sustainment Center | Total Small Business | |
| 2-STEP SEALED BID - TINKER AFB WWYK250019 Remove and Replace Fire Sprinkler in Plasma Booth Dust Collectors and Replace the Building F/A System, B3221 | Air Force Sustainment Center | Total Small Business | |
| Fire apparatus intercom system uplift and installation | Air Force Test Center | Total Small Business | |
| J012-- Fire Alarm Suppression Maintenance & Repair Services | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| SACN Replace Fire Alarms and Intrusions Systems | — | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity