Nitrogen piping replacement for plasma spray booth
Closed Solicitation Posted
- Solicitation number
- FA812627Q0004
- Agency
-
Air Force Sustainment Center
Air Force Materiel Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Place of performance
- Tinker AFB, Oklahoma 73145, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force, Air Force Sustainment Center, through contracting activity AF SC/PZIMB at Tinker Air Force Base, seeks quotes to replace nitrogen piping for a plasma spray booth, with quotations due November 9, 2026, at 12:00 p.m. Central Standard Time. The procurement is a Total Small Business set-aside, issued as a Request for Quote under FAR Part 13 for commercial items.
The requirement is one unit under a firm-fixed-price contract awarded to the lowest-priced, technically acceptable vendor. Work is performed at Tinker Air Force Base, Oklahoma City, Oklahoma, Monday through Friday, 0700 to 1900, excluding federal holidays and base closures. Delivery is due within 60 days after receipt of order to Building 3001 at Tinker AFB, Oklahoma 73145, FOB Destination, with inspection and acceptance at both the contractor's facility and destination.
The scope is a complete replacement of a 5,000 psi nitrogen piping system using 316 stainless steel pipe, installed per ASME B31.3 and government drawing 24E173. Welding is TIG, and the welder must hold 6G certification in 316 stainless steel piping. Hydrostatic testing at 7,500 psi for one hour applies to piping and valves only, excluding the generator, tanks, regulator, and filter. Pneumatic testing at 5,500 psi runs two continuous hours with zero leaks. The finished system must be free of particulates and oils and 99.9 percent free of water and moisture after testing, with the contractor responsible for water removal. Approximate existing runs are 275 to 325 feet and 50 to 75 feet at 25 feet above finished floor, and all dimensions require field verification.
The contractor provides all labor, tools, materials, equipment including lifts for overhead work, and the Fire Department Hot Work permit. Personnel complete ISO 50001 training of approximately 1.0 hour per employee. Removed materials return to the government.
Vendors must be registered in SAM or are ineligible for award. The size standard is $12.5 million under NAICS 811310, and the PSC is J049. No incumbent is named. Quotes must include pricing on the CLIN unit pricing sheet and proof of fulfillment of technical evaluation criteria. Contact Brian Eakers, Contracting Specialist, at Brian.eakers@us.af.mil.
Notice text
A complete, leak-free nitrogen piping system connecting the nitrogen generator, storage cylinders, regulator, and plasma spray booth.
IAW PWS
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Gas Line Repair | Air Combat Command | Total Small Business | |
| Nitrogen Generator | Air Force Sustainment Center | No set-aside | |
| 2-STEP SEALED BID - TINKER AFB WWYK250019 Remove and Replace Fire Sprinkler in Plasma Booth Dust Collectors and Replace the Building F/A System, B3221 | Air Force Sustainment Center | Total Small Business | |
| Purging system, dry NI | Land and Maritime | No set-aside | |
| Remanufacture of Liquid Oxygen Tanks | Air Force Sustainment Center | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity