J065--Imaging Service & Maintenance EHCC & MTV
Open Solicitation Posted
- Solicitation number
- 36C25527Q0053
- Agency
-
Veterans Integrated Service Network 15
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 seeks preventative maintenance of imaging equipment through an unrestricted solicitation, with offers due December 2, 2026. No set-aside is used.
Place of performance is the Evansville VA Health Care Center in Evansville, Indiana and the Mt. Vernon Clinic in Mt. Vernon, Illinois. The notice describes Philips imaging equipment, while the attachment's GovTribe AI summary describes 14 pieces of GE Healthcare equipment, including X-ray systems, ultrasound equipment, and digital detectors. The attachment summary states the contractor must be an authorized OEM service provider and employ Field Service Engineers with manufacturer training and at least two years of field experience. Required services include full-service preventative maintenance, repairs, software updates, remote diagnostic support, and parts replacement, with all parts and software updates provided at no additional cost. On-site repairs must begin within four hours of service calls during VA business hours of 8:00 AM to 4:30 PM, Monday through Friday. Guaranteed uptime is 97 percent for radiology equipment and 95 percent for ultrasound equipment. Work must comply with NFPA-99, OSHA, and CDRH standards, along with VA information security, privacy, and personnel credentialing requirements.
The base period is one year, with four optional one-year extensions for a potential five-year total. The attachment summary cites a $34 million total acquisition budget. The attachment summary also sets liquidated damages of $37.50 per affected individual for data breaches and requires workers' compensation with at least $100,000 employer's liability, $500,000 general liability, and $200,000/$500,000 automobile liability coverage.
Notice text
This is a solicitation for preventative maintenance of Philips imaging equipment.
Files
| File | Type | Posted |
|---|---|---|
| 36C25527Q0053_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| J065--Imaging Service & Maintenance EHCC & MTV | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J065--Fort Harrison GE Precision Radiology Preventive Maintenance | Veterans Integrated Service Network 19 | No set-aside | |
| 36C25527Q0048 - CT Contrast Injector Maintenance Services | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| 6525--SEP 2026 Equipment Only Consolidation | National Acquisition Center | No set-aside | |
| J065-- Bayer Radiology Injector Maint. - White River Junction VAMC | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business | |
| NX EQ Transesophageal Echocardiography (TEE) Scanning Systems | VA Strategic Acquisition Center Frederick | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity