J063--Building 350 Avigilon Security

Closed Solicitation Posted

Solicitation number
36C25026Q0672
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 10 seeks installation and programming of an Avigilon Physical Access Control System at Building 350 (Hospice) of the Dayton VA Medical Center, with proposals due July 24, 2026. The procurement is a total SDVOSB set-aside, restricting competition to service-disabled veteran-owned small businesses.

Place of performance is Building 350, Dayton VA Medical Center, 4100 West Third Street, Dayton, Ohio 45428. The project scope involves replacing existing Honeywell and C-Cure systems and controlling 12 access-controlled doors with network improvements. Specific equipment required includes one Mercury MP1502 controller, one Mercury MR-52-S3B controller, and one 24-port Lantronix SM24TAT2S4 network switch with one Cat6 port and one fiber port. Life safety power components are either two FPO 150-B100C808PE4M units or four FPO 75-B100C4D8PE2M units. Existing card readers, locks, REX devices, door contacts, and cabling will be reused with no hardware replacement required.

Contractor responsibilities include demolition of existing enclosures, installation of three new Avigilon PACS enclosures, programming all doors in Avigilon ACM, creating user profile templates, coordinating with VA Police Department for access validation, and providing one year of maintenance, support, programming, testing, and licensing following system commissioning. Work must be completed within 90 days of contract award during normal business hours Monday through Friday, 8:00 AM to 4:30 PM.

The NAICS code is 811210, Electronic and Precision Equipment Repair and Maintenance. The PSC code is J063, Maint/Repair/Rebuild Of Equipment—Alarm, Signal, And Security Detection Systems. A mandatory site visit was held July 16 at 9:00 AM. Service Contract Act wage determination WD #2015-4731 (Revision 29) applies. For services, the contractor must not pay more than 50% of the government-paid contract amount to firms not certified as SDVOSB or VOSB. Quotations must be submitted electronically to Stacie Hill at stacie.hill@va.gov. Amendment 0003, issued July 17, confirms sufficient door licenses are available on the existing system and closes the Q&A period.

Notice text

4 versions

Update #4 · Latest ·

Attachment(s):

***END OF AMENDMENT***

Update #3 ·

Q&A

Can you please identify the 16 access-controlled doors included in the project scope? (1) 101A, (2) 147D & 112, (2) 122C & 132D, (1) 103B, (2) 108 & 119, (1) 128A, (2) 138A & 147E, (1) 115A. There are only 12 access controlled doors.

Are the existing card readers, locks, REX devices, door contacts, and cabling intended to be reused? Yes

Can you please identify the location of Room 138A on the Building 350 floor plan? On the blueprint, it is the unmarked room next to 138B

Are there specific Avigilon controller models or part numbers required for this project? (1) Mercury MP1502, (1) Mercury MR-52-S3B

Are there any specific requirements for the new network switch, including manufacturer, model, uplink, or fiber/SFP requirements? (1) 24 Port Network Switch Lantronix SM24TAT2S4

Are there any Drawings? Please see previous amendment.

Are all existing Doors Hardware working? (Strikes, Mags, Card readers, Door contacts, Motions, Etc.) Yes

Are we replacing any Hardware? (Strikes, Mags, Card readers, Door contacts, Motions, Etc.) No

If existing Hardware Is not compatible/nonfunctional will that be covered under a Change order? All existing hardware should be compatible.

Is all Existing Cabling working and compatible with Avigilon Access control? Yes

Are we replacing Cabling? No

How many Existing doors are in each one of these Existing Honeywell/C-Cure panels? (12) Door and (15) Readers

Are we Wiring the Enclosures/Panels or just replacing Enclosures/Panels? Replacing Enclosures Life Safety Power (2) FPO 150-B100C808PE4M or (4) FPO 75-B100C4D8PE2M and wiring the enclosers

What type of Media converters are Existing? Fiber to Ethernet

How many Cat6/Fiber Ports do they need on their New Switch? 1 of each, 24 port switch for possible camera upgrade

Update #2 ·

See attached: B-350 1st Floor Plan

Update #1 ·

DVAMC needs to upgrade the access control system at DVAMC Building 350 by replacing the existing Honeywell and C-Cure systems with an Avigilon Physical Access Control System (PACS). The upgrade will include 16 doors and network improvements to support the new system infrastructure.

Files

File Type Posted
Sign In Sheet.pdf PDF
36C25026Q0672 0003.docx DOCX document
36C25026Q0672 0002.docx DOCX document
36C25026Q0672 0001.docx DOCX document
B-350 1st Floor Plan.pdf PDF
ATTACHMENT II - VAAR 852.219-75.docx DOCX document
ATTACHMENT III - JA redacted.pdf PDF
ATTACHMENT I - WD.pdf PDF
36C25026Q0672_1.docx DOCX document

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
J063--Building 350 Avigilon Security Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--Project No. 539-24-101 - Replace Failing Electrical Equipment. Cincinnati VA Medical Center 3200 Vine Street · NAICS 238210 Veterans Integrated Service Network 10 Service-Disabled Veteran-Owned Small Business
7A21--460-24-009 CLC and Fourth Floor Patient Elopement System Wilmington VA Medical Center 1601 Kirkwood Highway Wilmington DE 19805 · NAICS 541519 Veterans Integrated Service Network 4 Service-Disabled Veteran-Owned Small Business
Z2DA--Renovate Space for Patient Care Improvements Asheville, North Carolina 28805, United States · NAICS 236220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity