J041--Cooling Towers Structural Repairs
Closed Solicitation Posted
- Solicitation number
- 36C25724Q0534
- Agency
- Veterans Integrated Service Network 17 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- J041 Maint/Repair/Rebuild Of Equipment- Refrigeration, Air Conditioning, And Air Circulating Equipment
- Place of performance
- Vamc Garland 2300 Marie Curie Dr.
- Points of contact
-
- Sherine Brooks sherine.brooks@va.gov (254) 538-0416
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Department of Veterans Affairs (VA), Veterans Health Administration, Veterans Integrated Service Network 17 is seeking structural repairs and maintenance to the cooling towers that serve the YORK Centrifugal Chillers at the Garland VA Medical Center campus. The required work includes component replacement and structural repairs to three EVAPCO and one Marley cooling towers, as well as a 6-month rental of a 900-ton cooling tower. The project scope covers replacing cooling tower fill, louvers, supports, valves, nozzles, and other structural elements. The repairs must be performed in phases to minimize impact on the hospital's cooling load. Offers will be evaluated on technical capability, price, and past performance to determine the best value.
This is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs). The Period of Performance is 180 days after contract award, with a place of performance at 2300 Marie Curie Dr., Garland, TX 75042. Proposals are due by May 31, 2024 at 4:00 PM Central Time.
Notice text
2 versions
Update #2 · Latest ·
INTENTIONALLY LEFT BLANK
Update #1 ·
Structural Repairs Cooling Towers Cooling Tower
VAMC Garland
Repairs that include, Component Replacement and Structural Repairs of (3) EVAPCO (2 Cells each) and (1) Marley Cooling Towers that serve the YORK Centrifugal Chillers located at the Garland VA Campus. And will include, but not limited to: New Cooling Tower Fill, Louvers, Tower Supports and Brackets, Makeup Fill Valves, Nozzles, Basin Heaters, Vibration Switches, and Repair or Replacement of the Structural Components of load bearing nature associated with Cooling Towers - Motor Supports, and Gear Box Supports if needed. Disposal of removed materials. Includes 6-month Rental (900 ton) Cooling Tower with tie into Condenser Water System at the Cooling Tower Yard.
Crane service, lifts, and scaffolding needed are included. Operational testing and vibration analysis included.
All Cooling Tower Equipment/Materials/Installation as per Engineering Standard ES-2019-001, VHA Construction Spec Section 23 65 00 Cooling Towers, and HVAC Design Manual Rev. Nov 1, 2023.
Project will require phasing of the repairs to minimize impact on the hospital cooling load. Contractor will coordinate phasing plan with the COR upon contract award.
POP: 180 days after award. | Location: 2300 Marie Curie Dr., Garland TX 75042
Attachments
| File | Type | Posted |
|---|---|---|
| SF30 36C25724Q0534 0002.docx | DOCX document | |
| Technical Questions-Cooling Towers.docx | DOCX document | |
| 36C25724Q0534 0002_1.docx | DOCX document | |
| SF30 36C25724Q0534 0001.docx | DOCX document | |
| 36C25724Q0534 0001_1.docx | DOCX document | |
| 36C25724Q0534_2.docx | DOCX document | |
| Service Contract Act WD_2015-5227_rv21_12-23-2023.pdf | ||
| S02 RFQ 36C25724Q0534.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| J041--Cooling Towers Structural Repairs | Solicitation | |
| J041--NEW | Cooling Towers Structural Repairs Garland, TX | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity