J012--Replace Fire Dampers Bldg. 1
Closed Pre-Solicitation Posted
- Solicitation number
- 36C24624Q0558
- Agency
-
Veterans Integrated Service Network 6
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Fayetteville Vamc Fayetteville, North Carolina 28301, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs (VA) Veterans Health Administration Veterans Integrated Service Network 6 is seeking a contractor to provide all supervision, labor, materials, and equipment necessary to complete the removal and replacement of fire/smoke dampers in Building 1 at the VA Medical Center in Fayetteville, North Carolina. The work must be performed in accordance with applicable regulations and standards, including confirming damper locations and sizes, submitting product data, providing a detailed schedule, protecting surrounding areas, and installing the new dampers per specified methods. The contractor will also be required to perform verification testing and provide a final report. The tentative dates for the solicitation issuance and bid opening are June 17, 2024 and July 17, 2024, respectively.
This is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside procurement under NAICS code 238220, Commercial and Institutional Building Construction, with a maximum small business size standard of $19 million. The estimated magnitude of the construction work is between $25,000 and $100,000. All interested parties must be verified as an SDVOSB with the Small Business Administration Veterans Certification prior to submitting a bid.
Notice text
The VA Medical Center, Fayetteville, NC (VAMC Fayetteville) has need for a firm to provide all
supervision, labor, materials, and equipment necessary to complete Project 565-24-109, Replace Fire
Dampers Bldg. 1. The contractor shall complete the removal and replacement of Fire/Smoke dampers.
Installation Requirements
All work shall be performed in full accordance with applicable local and Federal regulations. All equipment and installation shall conform to the VA master specifications, recommendations of the National Fire Protection Association (NFPA), and Underwriters Laboratories, Inc. The contractor shall use good safety practices during demolition and installation.
Contractor to perform a site visit to confirm damper locations and sizes.
Contractor to submit cutsheets for products to be used and a detailed schedule identifying location of work with anticipated durations (coordination with patient care and VA COR is required) before starting work.
Contractor to remove as much dust and debris on damper and within ductwork utilizing HEPA filtered vacuums before demolition begins. Diffusers within the space will need to be covered during removal and installation of new dampers.
Contractor to install dampers with required perimeter mounting angles, sleeves, breakaway duct connections, corrosion resistant springs, bearings, bushings and hinges per UL and NFPA.
Contractor to perform verification and demonstrate of re setting and operation of dampers.
Contractor to provide a final report listing each damper replaced, a check list showing that all post-installation test functions are complete with pictures of open , closed:, and reopen demonstrating the operability of the damper, date of installation, the model, and identification number of the damper.
This is a Pre-solicitation only. Interested contractors should watch for the issuance of the solicitation which will have specific instructions and requirements associated with this procurement. The tentative date for issuing the solicitation is June 17, 2024, with a bid opening on or about July 17, 2024. These are only tentative dates. The solicitation will have specific dates, times, and locations for the bid opening and site visit. The magnitude of construction per FAR Part 36 is between $25,000.00 and $100,000.00. This is a 100% SDVOSB set-aside. The NAICS Code for this procurement is 238220, Commercial and Institutional Building Construction, with a maximum small business size standard of $19 million. All interested parties must be verified as an SDVOSB with the Small Business Administration Veterans Certification prior to submitting a bid.
This is a PRESOLICITATION NOTICE only. This is not a request for pricing at this time.
Files
| File | Type | Posted |
|---|---|---|
| 36C24624Q0558_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Pre-Solicitation | |
| J012--Replace Fire Dampers Bldg. 1 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--Renovate Space for Patient Care Improvements | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Annual Inventory and Inspection of Fire and Smoke Doors | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--542-21-113 | Correct FCA Deficiencies – Repair Water Penetration | NCO 4 Construction East (VA-26-00020634) (VA-26-00020634) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| J012-- Fire Alarm Suppression Maintenance & Repair Services | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity