Inspection services for Fire Protection Systems
Closed Pre-Solicitation Posted
- Solicitation number
- FA480025QA061
- Agency
-
Air Combat Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238390 Other Building Finishing Contractors
- Place of performance
- Langley AFB, Virginia 23665, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Combat Command, specifically the 633rd Contracting Squadron, is seeking inspection services for fire protection systems at Langley Air Force Base. The primary objective is to upgrade the fire protection system in Building 1102's Bays A and D from a water-based sprinkler system to a heat detection system using Honeywell Velociti Series 3 intelligent addressable heat detectors. The contract requires a licensed engineer to conduct a comprehensive site survey, procure and install heat detectors, set individual detector addresses, and perform full system testing. Interested vendors must submit company information, including point of contact details, business size, description, and estimated pricing by 5:00 PM EST on April 18, 2025. The evaluation criteria will focus on compliance, technical capabilities, and pricing, with an emphasis on the vendor's ability to address the critical safety concerns in the munitions storage area.
The procurement is designated as a total small business set-aside, targeting small businesses with expertise in fire protection systems and building finishing contractors. No incumbent contractors are specifically mentioned in the notice. While a precise award value is not disclosed, the contract will be structured as a firm-fixed-price (FFP) agreement under FAR Part 13 guidelines. The project timeline indicates work is scheduled to be performed between 31 April and 3 May 2025, with the 1st Lt Jorge Y. Ramirez Reyes serving as the point of contact. The project addresses a significant safety hazard in a facility used for flare storage and processing, where the current water-based system poses risks due to potential electrical ignition with Class V assets. Interim fire watch will be maintained by Conventional Maintenance personnel until the new heat detection system is fully operational.
Notice text
SUBJECT: Sources Sought Inspection Services for Fire Protection Systems
1. Purpose:
The 633rd Contracting Squadron is conducting market research to identify potential sources capable of providing inspection services for fire protection systems, specifically thermal detectors. This is a Sources Sought notice, NOT a solicitation. The requirement involves inspections in Building 1102, Bays A and D, located within the Munitions Storage Area of Langley Air Force Base at 594 Worley Road, Hampton, VA, 23665. The government seeks a licensed engineer to perform these inspections. This Sources Sought is issued in accordance with FAR Subpart 12.6 and includes supplemental information.
The 633rd Contracting Squadron plans to award a firm-fixed-price (FFP) contract to a small business in accordance with the guidelines established in FAR Part 13 and the requirements outlined in this request, along with the attached Statement of Work (SOW).
2. Background:
Building 1102, Bays A & D, utilized for flare storage and processing, currently employs an automatic water sprinkler system that presents a significant hazard. A semi-annual fire drill conducted on December 7, 2023, highlighted this critical safety concern. These Class V assets require a "no water" fire suppression approach due to the significant ignition hazard posed by static electricity interacting with electrically initiated materials. Since March 2024, the 1st Munitions Squadron has been working to address this issue by procuring appropriate heat detectors, but has faced challenges identifying the correct type, quantity, pricing, and a suitable contractor. This building is occupied almost daily, and the current system poses a serious risk of rapid fire spread and potential loss of life should an incident occur. Therefore, we are reaching out to invite engineers with relevant expertise to collaborate with us in developing effective solutions. Details regarding the specific hazards associated with the current system, as well as the requirements for remediation, are outlined in the attached Statement of Work (SOW). We encourage you to review the SOW and work with us to ensure the safety of everyone in and around this facility. Your expertise could make a significant difference in mitigating this critical safety hazard.
3. Requirement Description
This requirement calls for upgrading the fire protection system in Building 1102's Chaff and Flare processing bay (Bays A & D) from a water-based sprinkler system to a heat detection system. The designated system shall utilize Honeywell Velociti Series 3 intelligent addressable heat detectors with point ID capability, complete with appropriate mounting bases, and integrated into the existing fire alarm control panel. The contractor will be responsible for conducting a comprehensive site survey to determine the necessary quantity and placement of detectors for complete regulatory compliance. Following the survey, the contractor will procure and install the specified heat detectors, setting individual detector addresses for precise location identification. Full system testing and verification will be required to ensure proper communication with the fire alarm control panel and accurate temperature monitoring. Finally, the contractor will deactivate the existing water-based sprinkler system upon successful heat detector system installation and testing. All work must adhere to applicable state and federal regulations. Interim fire watch will be maintained by Conventional Maintenance personnel until the new system is fully operational.
4. Anticipated Procurement Approach:
The procurement strategy is expected to be a competitive set-aside for small businesses, with an emphasis on compliance and pricing.
5. Response Requested:
Interested vendors are requested to provide the following information:
-
- Company Name
- Point of Contact Information (Name, Title, Phone, Email)
- Business Size (Small Business, Large Business, Other)
- Description of the proposed bus and size
- Estimate pricing information
6. Submission Instructions:
Responses and questions to this notice should be submitted via email to Kelly Voigts at kelly.voigts.3@us.af.mil no later than 5:00 PM EST, 18 April 2025.
7. Point of Contact:
For questions or further information regarding this notice, please contact Kelly Voigts at kelly.voigts.3@us.af.mil.
8. Conclusion:
This Sources Sought notice is for market research purposes only and does not serve as a solicitation. The information gathered will be utilized to shape the acquisition strategy. For further details, please refer to the attached SOW.
Files
| File | Type | Posted |
|---|---|---|
| 1 MUNS Heat Detectors SOW (Final).pdf | ||
| Sources Sought - 1 MUNS Heat Detectors.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Fire Alarm/Suppression Inspection, Testing, and Maintenance | Air Force Research Laboratory | No set-aside | |
| Inspection of Fire Extinguishers and Suppression Systems for AMXG at Hill AFB, Utah | Air Force Sustainment Center | Total Small Business | |
| H312--Fire Alarm Maintenance Service Contract FY27 - NEW Base + Four - 583 | Veterans Integrated Service Network 10 | No set-aside | |
| Tessy control panel | Land and Maritime | Total Small Business | |
| Airfield Lighting Computer System | Air Combat Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity