Generator Rewinds, Chief Joseph Dam, WA

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W912DW22R0005
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Bridgeport, Washington 98813, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation seeks rehabilitation of generator rewinds at Chief Joseph Dam in Washington. The U.S. Army Corps of Engineers Seattle District requires disassembly and reassembly of 16 generators, removal and installation of new stator windings, optional replacement of up to 15 stator cores, cleaning and testing or replacement of field windings, replacement of generator breaker components and piping, installation of new machine condition monitoring systems, and other refurbishment and inspection work. Proposals will be evaluated on technical approach, past performance, and price. The submission deadline is February 22, 2022.

There is no set-aside designation. The NAICS code is 238210 and PSC code is R499. The estimated value ranges from $100 million to $250 million to be performed over 3,285 calendar days at the Chief Joseph Dam facility in Bridgeport, Washington. Work includes removal and replacement of existing stator and field windings for 16 generators, replacement of piping, brakes and air coolers, installation of monitoring systems, and optional testing and component replacement.

Notice text

The U.S. Army Corps of Engineers (USACE), Seattle District, requires rehabilitation of the Chief Joseph Generator Rewinds (16 Units) and incidental related work. The following is a list of the major items of work included in this Contract. The work includes the removal of the existing components and systems of components which are known to have lead-based paint, without being specifically identified. The work includes:

Mobilization and demobilization.

Disassemble and reassemble 16 generators, including generator alignment.

Removal of 16 existing stator windings.

Installation of 16 new stator windings, including winding supplies and connections such as circuit rings, surge rings, main and neutral leads, neutral Current Transformer (CTs), wedges, fillers, etc.

Supply and install one stator core in a to be determined unit.

Reuse up to 15 existing stator cores, following cleaning and testing.

Optional replacement of up to 15 stator cores.

Reuse existing field winding and collector rings of all units, following cleaning and testing.

Optional field winding refurbishment on a per pole basis.

Replace generator breaker CTs for all units.

Replacement of all generator raw water piping from the cooling water strainer to the discharge valve, with the exception of the thrust bearing cooling branch, for all units.

Clean, inspect, and reuse the brake system of all units without disassembly.

Redesign and replace the brake ring of all units.

Replace generator brake pads.

Install new Machine Condition Monitoring (MCM) system including shaft vibration, generator air gap, and continuous online partial discharge monitoring devices for all units.

Instrumentation for generator temperature monitoring, Resistance Temperature Detector (RTDs), MCM system design drawings and specifications, interfacing with Generic Data Acquistiion and Control System (GDACS) or evaluating alternative interfaces for all units.

Stator foundation inspection of all units with optional minor repairs.

Replace all generator air coolers.

Optional model validation testing of up to 16 units.

In accordance with FAR 36.204 "Disclosure of the Magnitude of Construction Projects," the magnitude of the project is estimated between $100,000,000 and $250,000,000.

See attached solicitation W912DW22R0005 for additional information.

Files

File Type Posted
W912DW22R0005 R0006.pdf PDF
W912DW22R0005 R0005.pdf PDF
W912DW22R0005-R0004.pdf PDF
W912DW22R0005-R0003.pdf PDF
W912DW22R0005-R0002.pdf PDF
W912DW22R0005-R0001.pdf PDF
Brand Name JA - CJD Generator Rewinds 1-16.pdf PDF
Attachment D PPQ.docx DOCX document
Attachment A Past Performance Project Relevancy Template.docx DOCX document
Attachment C PROPOSAL DATA SHEET.docx DOCX document
Attachment B SBPCD.docx DOCX document
W912DW22R0005 CJD GENERATOR REWINDS (1-16).pdf PDF
Show all 12

Notice history

Notice Type Posted
Chief Joseph Dam Generator Rewinds, 1-16, Bridgeport, WA Award Award Notice
This notice Latest solicitation Solicitation
Generator Rewinds, Chief Joseph Dam, WA Pre-Solicitation
Generator Rewinds, Chief Joseph Dam, WA Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
LLA Fish Pump - Motor Rewind Pomeroy, Washington 99347, United States · NAICS 811310 ENDIST Walla Walla No set-aside
Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT Mansfield Center, Connecticut, United States · NAICS 238290 ENDIST New England Total Small Business
Johnston Ridge Observatory Backup Generator Repairs Gifford Pinchot National Forest Toutle, Washington 98649, United States · NAICS 238290 Region 6 - Pacific Northwest Region Total Small Business
John day DAM unit 10 packing box replacement John Day Dam, Sherman County, Oregonthe John Day Dam On The Columbia River Between Sherman County, Oregon, And Klickitat County, Washington. Rufus, Oregon 97050, United States · NAICS 237990 ENDIST Portland No set-aside
Tenkiller Hydropower Excitation System Replacement Gore, Oklahoma, United States · NAICS 237990 ENDIST Tulsa No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity