Generator Rewinds, Chief Joseph Dam, WA

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
W912DW21X0999
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

PSC
Not on record
Place of performance
Bridgeport, Washington 98813, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This notice seeks information from contractors interested in the rehabilitation of 16 generator units at Chief Joseph Dam in Washington State. The U.S. Army Corps of Engineers, Seattle District, intends to issue a firm fixed-price construction contract valued between $100-250 million requiring payment and performance bonds. Contractors must demonstrate experience rehabilitating similar hydroelectric generator units by providing descriptions of three past projects including contract values, locations, dates and customer references. Capabilities statements must be submitted to the Contract Specialist by April 21, 2021.

There is no set-aside designated for this opportunity. The applicable NAICS code is 237990 for other heavy and civil engineering construction, with a $39.5 million size standard. The work is estimated to take place over multiple years and includes removal and replacement of stator windings, cooling systems, instrumentation and testing of all 16 generator units. Optional work may include replacement of stator cores or field windings. Interested parties must be registered in SAM.gov to receive any future solicitation that may be issued for this requirement.

Notice text

2 versions

Update #2 · Latest ·

Point of Contact: Contract Specialist Monique Paano at Monique.a.paano@usace.army.mil

US Army Corps of Engineers (USACE), Seattle District, is seeking interested business sources for a construction Project titled: Generator Rewinds, Chief Joseph Dam, WA.

Proposed project will be a firm fixed-price construction project. Construction magnitude is estimated to be between $100,000,000 and $250,000,000. 100 percent payment and performance bonds will be required.

The North American Industry Classification System (NAICS) code for this project is 237990, Other Heavy and Civil Engineering Construction, and the associated small business size standard is $39,500,000 in average annual receipts.

This sources-sought announcement is a tool to identify businesses with the capability to accomplish the work and is for information/market research purposes only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS, NOR A SYNOPSIS OF A PROPOSED CONTRACT ACTION UNDER FAR SUBPART 5.2. The type of solicitation to be issued will depend upon information received in response to this sources sought announcement. No reimbursement will be made for any costs associated with providing information in response to this sources sought announcement or any follow up information. Responses to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. NO SOLICITATION IS CURRENTLY AVAILABLE. This is not a request to be placed on a solicitation mailing list and is not to be construed as a commitment by the Government. The results of this survey will be in effect for a period of one year from the date of this notice.

Summary Scope of Work (SOW):

OVERVIEW: U.S. Army Corps of Engineers (USACE), Seattle District, requires rehabilitation of the Chief Joseph Generator Rewinds (16 Units) and incidental related work. The following is a list of the major items of work included in this Contract. The work includes the removal of the existing components and systems of components which are known to have lead-based paint, without being specifically identified. The work includes, but is not limited to:

  1. Mobilization and demobilization.
  2. Disassemble and reassemble 16 generators, including generator alignment.
  3. Removal of 16 existing stator windings.
  4. Installation of 16 new stator windings, including winding supplies and connections such as circuit rings, surge rings, main and neutral leads, neutral CTs, wedges, fillers, etc.
  5. Supply and install one stator core in a to be determined unit.
  6. Reuse up to 15 existing stator cores, following cleaning and testing.
  7. Optional replacement of up to 15 stator cores.
  8. Reuse existing field winding and collector rings of all units, following cleaning and testing.
  9. Optional field winding refurbishment on a per pole basis.
  10. Replace generator breaker CTs for all units.
  11. Replacement of all generator raw water piping from the cooling water strainer to the discharge valve, with the exception of the thrust bearing cooling branch, for all units.
  12. Clean, inspect, and reuse the brake system of all units without disassembly.
  13. Redesign and replace the brake ring of all units.
  14. Replace generator brake pads.
  15. Install new MCM system including shaft vibration, generator air gap, and continuous online partial discharge monitoring devices for all units.
  16. Instrumentation for generator temperature monitoring, RTDs, MCM system design drawings and specifications, interfacing with GDACS or evaluating alternative interfaces for all units.
  17. Stator foundation inspection of all units with optional minor repairs.
  18. Replace all generator air coolers.
  19. Optional model validation testing of up to 16 units.

REQUIREMENTS:

Interested firms should submit a capabilities package, to include the following:

1. Firm's name, address (mailing and URL), point of contact, phone number, email address.

2. Business classification, i.e., Small Business (SB), Small Disadvantage Business (SDB), Woman-Owned Small Business (WOSB), Veteran Owned Small Business (VOSB), Service Disabled Veteran Owned Small Business (SDVOSB), Historically Underutilized Business Zone (HUBZone) Small Business, 8(a) Program, or Other Than Small Business (large business).

3. Submit three projects that demonstrates Contractor’s ability to rehabilitate Chief Joseph Dam Generator Rewinds. Project information submitted shall contain:

  • Project Name/Title;
  • Contract awarded amount;
  • Project location;
  • Project start date;
  • Project completion date;
  • Contractor shall provide a detailed description of the following: The completed projects scope and complexity, number of units rehabilitated and CPARs or performance rating.

4. CAGE code and DUNS number.

5. Firm's Joint Venture Information, if applicable.

6. Bonding Information:

a. Provide the following, on the bonding company's letterhead:

(1) Bonding Limits

(a) Single Bond

(b) Aggregate

7.  Identify if your firm intends to team or subcontract any work under this requirement, and what is the anticipated percentage of work you are capable of in your own right and what percentage you are subcontracting:

__Large Business (LB)____%

__Small Business (SB)____%

__Small Disadvantaged Business (SDB)____%

__Woman-Owned SB (WOSB)____%

__Veteran-Owned SB (VOSB)____%

__Service-Disabled VOSB (SDVOSB)____%

__Historically Underutilized Business Zone (HUBZone)____%

This research is for planning purposes only and does not constitute a solicitation for competitive bids/proposals and is not to be construed as a commitment by the Corps.  All interested parties who believe they can meet the requirements are invited to submit, in writing, complete information describing their interest and ability to meet all requirements stated above. Prior Government contract work is not required for submitting a response under the sources sought announcement.

The official Synopsis citing a solicitation number will be issued on Federal Business Opportunities (www.SAM.gov) inviting firms to register electronically to receive an electronic notification of a solicitation should one be issued.

SUBMIT TO: Responses to the Sources Sought Announcement should be received no later than 1:00 pm (Pacific Time) on 12 July 2021. Submit responses to the attention of Monique Paano, Contract Specialist, by email: monique.a.paano@usace.army.mil.

All interested firms must be registered in SAM (https://www.sam.gov) and remain current for the duration of the contract to be eligible for award of Government contracts.

 

Update #1 ·

Point of Contact: Contract Specialist Monique Paano at Monique.a.paano@usace.army.mil

US Army Corps of Engineers (USACE), Seattle District, is seeking interested business sources for a construction Project titled: Generator Rewinds, Chief Joseph Dam, WA.

Proposed project will be a firm fixed-price construction project. Construction magnitude is estimated to be between $100,000,000 and $250,000,000. 100 percent payment and performance bonds will be required.

The North American Industry Classification System (NAICS) code for this project is 237990, Other Heavy and Civil Engineering Construction, and the associated small business size standard is $39,500,000 in average annual receipts.

This sources-sought announcement is a tool to identify businesses with the capability to accomplish the work and is for information/market research purposes only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS, NOR A SYNOPSIS OF A PROPOSED CONTRACT ACTION UNDER FAR SUBPART 5.2. The type of solicitation to be issued will depend upon information received in response to this sources sought announcement. No reimbursement will be made for any costs associated with providing information in response to this sources sought announcement or any follow up information. Responses to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. NO SOLICITATION IS CURRENTLY AVAILABLE. This is not a request to be placed on a solicitation mailing list and is not to be construed as a commitment by the Government. The results of this survey will be in effect for a period of one year from the date of this notice.

Summary Scope of Work (SOW):

OVERVIEW: U.S. Army Corps of Engineers (USACE), Seattle District, requires rehabilitation of the Chief Joseph Generator Rewinds (16 Units) and incidental related work. The following is a list of the major items of work included in this Contract. The work includes the removal of the existing components and systems of components which are known to have lead-based paint, without being specifically identified. The work includes, but is not limited to:

  1. Mobilization and demobilization.
  2. Disassemble and reassemble 16 generators, including generator alignment.
  3. Removal of 16 existing stator windings.
  4. Installation of 16 new stator windings, including winding supplies and connections such as circuit rings, surge rings, main and neutral leads, neutral CTs, wedges, fillers, etc.
  5. Supply and install one stator core in a to be determined unit.
  6. Reuse up to 15 existing stator cores, following cleaning and testing.
  7. Optional replacement of up to 15 stator cores.
  8. Reuse existing field winding and collector rings of all units, following cleaning and testing.
  9. Optional field winding refurbishment on a per pole basis.
  10. Replace generator breaker CTs for all units.
  11. Replacement of all generator raw water piping from the cooling water strainer to the discharge valve, with the exception of the thrust bearing cooling branch, for all units.
  12. Clean, inspect, and reuse the brake system of all units without disassembly.
  13. Redesign and replace the brake ring of all units.
  14. Replace generator brake pads.
  15. Install new MCM system including shaft vibration, generator air gap, and continuous online partial discharge monitoring devices for all units.
  16. Instrumentation for generator temperature monitoring, RTDs, MCM system design drawings and specifications, interfacing with GDACS or evaluating alternative interfaces for all units.
  17. Stator foundation inspection of all units with optional minor repairs.
  18. Replace all generator air coolers.
  19. Optional model validation testing of up to 16 units.

REQUIREMENTS:

Interested firms should submit a capabilities package, to include the following:

1. Firm's name, address (mailing and URL), point of contact, phone number, email address.

2. Business classification, i.e., Small Business (SB), Small Disadvantage Business (SDB), Woman-Owned Small Business (WOSB), Veteran Owned Small Business (VOSB), Service Disabled Veteran Owned Small Business (SDVOSB), Historically Underutilized Business Zone (HUBZone) Small Business, 8(a) Program, or Other Than Small Business (large business).

3. Submit three projects that demonstrates Contractor’s ability to rehabilitate Chief Joseph Dam Generator Rewinds. Project information submitted shall contain:

  • Project Name/Title;
  • Contract awarded amount;
  • Project location;
  • Project start date;
  • Project completion date;
  • Contractor shall provide a detailed description of the following: The completed projects scope and complexity, number of units rehabilitated and CPARs or performance rating.

4. CAGE code and DUNS number.

5. Firm's Joint Venture Information, if applicable.

6. Bonding Information:

a. Provide the following, on the bonding company's letterhead:

(1) Bonding Limits

(a) Single Bond

(b) Aggregate

All interested parties who believe they can meet the requirements are invited to submit, in writing, complete information describing their interest and ability to meet all requirements stated above. Prior Government contract work is not required for submitting a response under the sources sought announcement.

The official Synopsis citing a solicitation number will be issued on Federal Business Opportunities (www.SAM.gov) inviting firms to register electronically to receive an electronic notification of a solicitation should one be issued.

SUBMIT TO: Responses to the Sources Sought Announcement should be received no later than 1:00 pm (Pacific Time) on 21 April 2021. Submit responses to the attention of Monique Paano, Contract Specialist, by email: monique.a.paano@usace.army.mil.

All interested firms must be registered in SAM (https://www.sam.gov) and remain current for the duration of the contract to be eligible for award of Government contracts.

 

Notice history

Notice Type Posted
Chief Joseph Dam Generator Rewinds, 1-16, Bridgeport, WA Award Award Notice
Generator Rewinds, Chief Joseph Dam, WA Latest solicitation Solicitation
Generator Rewinds, Chief Joseph Dam, WA Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Eufaula Powerhouse Hydroelectric Generator Rewind Eufaula, Oklahoma, United States · NAICS 237990 ENDIST Tulsa No set-aside
Tenkiller Hydropower Excitation System Replacement Gore, Oklahoma, United States · NAICS 237990 ENDIST Tulsa No set-aside
Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT Mansfield Center, Connecticut, United States · NAICS 238290 ENDIST New England Total Small Business
LLA Fish Pump - Motor Rewind Pomeroy, Washington 99347, United States · NAICS 811310 ENDIST Walla Walla No set-aside
Camp wooten/starbuck levee rehab Starbuck, Washington 99359, United States · NAICS 237990 ENDIST Walla Walla No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity