Fort Totten, NY Army Reserve Center FFR
Closed Solicitation Posted
- Solicitation number
- W912QR20R0049
- Agency
-
ENDIST Louisville
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- New York Ny Usa
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers Louisville District is soliciting proposals under solicitation number W912QR20R0049 to conduct a full facility restoration of the 2000-member Army Reserve Center located at 200 Duane Rd., Fort Totten, Bayside, New York. The scope of work includes fully renovating 146,000 square feet of the existing training building, repairing failing building systems, and constructing new asphalt parking areas. Proposals will be evaluated based on technical qualifications, past performance, and price, with the award being made to the responsible offeror whose proposal provides the best overall value to the government. Proposals are due by August 3, 2020.
There is no set-aside designation for this procurement. The project's NAICS code is 238210 and PSC code is S206. The place of performance is New York, New York. The contract duration is 990 calendar days from notice to proceed. Optional items include roof replacement and additional parking areas. The total contract value is estimated between $10-25 million.
Notice text
2 versions
Update #2 · Latest ·
The U.S. Army Corps of Engineers (USACE) Louisville District publishes Request for Proposal (RFP) W912QR20R0049 to Conduct a Full Facility Restoration (FFR) on the 2000-member Army Reserve Center (USARC) at the existing Ft Totten, NY Army Reserve Center (ARC) Located at 200 Duane Rd., Ft Totten, Bayside, New York. This will be a Design/Build Construction project to fully renovate 146,000 SF of a 2,000-member Army Reserve Center (ARC) Training Building and will include new construction of asphalt parking areas with associated grade and drain work. Facilities will be designed according the USAR Design Guide, and to a minimum life of 40 years in accordance with DoD's Unified Facilities Criteria (UFC 1-200-02) including energy efficiencies, building envelope and integrated building systems performance. Scope of work will include design and repair construction of failing building systems to include Heating, Ventilation and Air Conditioning (HVAC), mechanical, electrical and plumbing (ME&P), fire alarm, telecommunications, and roof. Interior repair work includes corridors, classrooms, office areas, equipment rooms, commercial grade kitchen, restrooms, ceilings, lighting, doors, sprinklers, finishes and asbestos abatement. Exterior work includes site work, lighting and new Personal Operational Vehicle (POV) Parking. Accessibility for the disabled will be provided. Anti-Terrorism/Force Protection (AT/FP) and physical security measures per Army Regulations will be incorporated into the design including maximum standoff distances from roads, parking areas and vehicle unloading areas. Sustainability/Energy measures will be provided. The project contains options such as: roof replacement, paved parking areas and supplemental AT/FP provisions. The Contract Duration is 990 calendar days from Contract Notice To Proceed.
Update #1 ·
The U.S. Army Corps of Engineers (USACE) Louisville District publishes Request for Proposal (RFP) W912QR20R0049 to Conduct a Full Facility Restoration (FFR) on the 2000-member Army Reserve Center (USARC) at the existing Ft Totten, NY Army Reserve Center (ARC) Located at 200 Duane Rd., Ft Totten, Bayside, New York. This will be a Design/Build Construction project to fully renovate 146,000 SF of a 2,000-member Army Reserve Center (ARC) Training Building and will include new construction of asphalt parking areas with associated grade and drain work. Facilities will be designed according the USAR Design Guide, and to a minimum life of 40 years in accordance with DoD's Unified Facilities Criteria (UFC 1-200-02) including energy efficiencies, building envelope and integrated building systems performance. Scope of work will include design and repair construction of failing building systems to include Heating, Ventilation and Air Conditioning (HVAC), mechanical, electrical and plumbing (ME&P), fire alarm, telecommunications, and roof. Interior repair work includes corridors, classrooms, office areas, equipment rooms, commercial grade kitchen, restrooms, ceilings, lighting, doors, sprinklers, finishes and asbestos abatement. Exterior work includes site work, lighting and new Personal Operational Vehicle (POV) Parking. Accessibility for the disabled will be provided. Anti-Terrorism/Force Protection (AT/FP) and physical security measures per Army Regulations will be incorporated into the design including maximum standoff distances from roads, parking areas and vehicle unloading areas. Sustainability/Energy measures will be provided. The project contains options such as: roof replacement, paved
parking areas and supplemental AT/FP provisions. The Contract Duration is 990 calendar days from Contract Notice To Proceed.
Files
Show all 13
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Fort Totten, NY Army Reserve Center FFR | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Design-Build Maintenance and Repair Army Reserve (MRAR) of Equipment Concentration Site (ECS), B-56767, at North Fort Hood, TX | ENDIST Louisville | Total Small Business | |
| Design/Build Maintenance and Repair Army Reserve (MRAR), Area Maintenance Support Activity (AMSA) 21, JBMDL, NJ | ENDIST Louisville | Total Small Business | |
| Renovation at Truman Hall Headquarters in Fort Belvoir, VA | ENDIST Louisville | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity