Fort Totten, NY Army Reserve Center FFR

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
W912QR20R0049
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
New York Ny Usa

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers Louisville District will issue a Request for Proposal for a full facility restoration of the 2000-member Army Reserve Center located at 200 Duane Rd, Fort Totten, Bayside, New York. This will be a design-build project to renovate 146,000 SF of the training building and associated asphalt parking areas. The scope of work includes repairs to HVAC, mechanical, electrical and plumbing systems, the fire alarm, telecommunications, and roof. Interior repairs comprise corridors, classrooms, offices, equipment rooms, a commercial kitchen, restrooms, ceilings, lighting, doors, sprinklers and finishes. Exterior work includes site work, lighting and new POV parking. Anti-terrorism and force protection measures must be incorporated per Army regulations. Sustainability and energy measures are also required. Proposals are due by August 3, 2020.

There is no set-aside designated for this opportunity. The NAICS code is 238210 and the PSC code is S206. The contract duration is estimated at 990 calendar days from notice to proceed.

Notice text

The U.S. Army Corps of Engineers (USACE) Louisville District intends to issue a Request for Proposal (RFP) W912QR20R0049 to Conduct a Full Facility Restoration (FFR) on the 2000-member Army Reserve Center (USARC) at the existing Ft Totten, NY Army Reserve Center (ARC) Located at 200 Duane Rd., Ft Totten, Bayside, New York. This will be a Design/Build Construction project to fully renovate 146,000 SF of a 2,000-member Army Reserve Center (ARC) Training Building and will include new construction of asphalt parking areas with associated grade and drain work.  Facilities will be designed according the USAR Design Guide, and to a minimum life of 40 years in accordance with DoD's Unified Facilities Criteria (UFC 1-200-02) including energy efficiencies, building envelope and integrated building systems performance.  Scope of work will include design and repair construction of failing building systems to include Heating, Ventilation and Air Conditioning (HVAC), mechanical, electrical and plumbing (ME&P), fire alarm, telecommunications, and roof.  Interior repair work includes corridors, classrooms, office areas, equipment rooms, commercial grade kitchen, restrooms, ceilings, lighting, doors, sprinklers, finishes and asbestos abatement. Exterior work includes site work, lighting and new Personal Operational Vehicle (POV) Parking. Accessibility for the disabled will be provided. Anti-Terrorism/Force Protection (AT/FP) and physical security measures per Army Regulations will be incorporated into the design including maximum standoff distances from roads, parking areas and vehicle unloading areas. Sustainability/Energy measures will be provided. The project contains options such as: roof replacement, paved parking areas and supplemental AT/FP provisions.  The Contract Duration is estimated at 990 calendar days from Contract Notice To Proceed after Contract Award.

Notice history

Notice Type Posted
Fort Totten, NY Army Reserve Center FFR Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Design-Build Maintenance and Repair Army Reserve (MRAR) of Equipment Concentration Site (ECS), B-56767, at North Fort Hood, TX Bldg. 56767 Equipment Concentration Site (ECS) #6428th St. and Park Ave.North Fort Hood, TX Gatesville, Texas 76528, United States · NAICS 236220 ENDIST Louisville Total Small Business
Design/Build Maintenance and Repair Army Reserve (MRAR), Area Maintenance Support Activity (AMSA) 21, JBMDL, NJ Joint Base MDL, New Jersey, United States · NAICS 236220 ENDIST Louisville Total Small Business
Sources Sought- Sources Sought & Other Transaction Authority (OTA) Construction for Non-Destructive Testing Facility, Red River Army Depot, Texas Texas 75570, United States · NAICS 236220 ENDIST Fort Worth No set-aside
Renovation at Truman Hall Headquarters in Fort Belvoir, VA NAICS 236220 ENDIST Louisville No set-aside
Sources Sought -Building 493 Generator and Backup Power Installation- Red River Army Depot Texarkana, Texas 75501, United States · NAICS 238210 ENDIST Fort Worth No set-aside