About this opportunity

The Department of Veterans Affairs Veterans Health Administration (VA) is seeking a contractor to upgrade WiFi infrastructure at two medical centers in New York: the Margaret Cochran Corbin VA Medical Center in Manhattan and the St. Albans medical center in Queens. The project requires installation of 180 WiFi Access Points (154 in Manhattan, 26 in St. Albans), including 600 linear feet of EMT conduit, 36,000 linear feet of CAT 6A cable, and associated infrastructure improvements such as mounting brackets, junction boxes, and fire stopping. Contractors must follow strict infection control procedures, including using mobile HEPA containment when removing ceiling tiles. The solicitation will evaluate bids based on the lowest-priced, technically acceptable offer, with bids due by March 27, 2025 at 10:00 AM. A site visit is scheduled for March 6, 2025, at St. Albans VAMC and March 11, 2025, at Manhattan VAMC, with requests for information due by March 14, 2025.

The contract is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238210 with a size standard of $19 million. The project magnitude is estimated between $100,000 and $250,000, with a performance period of 10 weeks from the Notice to Proceed, requiring work to be completed during business hours (Monday through Friday, 8 AM to 4:30 PM). A bid bond of 20% of the bid price or $3,000,000 (whichever is less) is required. The contractor will be responsible for providing all labor, tools, materials, and equipment to support the WiFi access point installations, including creating new conduit pathways, installing cables from access points to IT rooms, and implementing comprehensive infection control measures. The work will involve detailed technical requirements, including specific provisions for cable routing, penetration sealing, and coordination with VA infrastructure standards.

Notice text

2 versions

Update #2 · Latest ·

VA New York Harbor HCS 12/17/24

423 East 23rd St.

New York, NY 10010

Page 2 of 8

CONSTRUCTION SCOPE OF WORK

EHRM NEXTGEN WIFI UPGRADES

PROJECT NO: 630-22-704

PROJECT NAME: EHRM NextGen WiFi Upgrades New York Harbor Healthcare System

1. GENERAL INTENT:

The Contractor shall furnish all labor, tools, materials and equipment to support installation of new WiFi Access Points at the Margaret Cochran Corbin VA Medical center in Manhattan 423 East 23rd St. New York, NY and at the St Albans medical center located at 179-00 Linden Blvd Queens, NY. Please note that the scope of this work is limited and specifically as listed below.

2. STATEMENT OF WORK:

Provide and install conduit, raceways, horizontal and vertical penetrations, and fire stopping to support NextGen WiFi installation at the New York Harbor healthcare system as shown and described in the project drawings and specifications. A list of required access point locations requiring conduits and/or penetrations are provided as SOW Attachment 1. SOW Attachment 2 and 2A include access point floor plans of the two medical centers.

Work shall include:

1. Installation of 180 WiFi Access Points (WAP s). WAP s will be provided by the VA, but the mounting brackets shall be provided by the Contractor. (154 access points are located at Manhattan campus and 26 at St Albans campus.)

2. Supply and Installation of 600 linear feet of EMT conduit, including junction boxes, pull cords, and fire stopping, throughout the Medical Centers. Existing conduit paths between floors/IT rooms will not have the capacity for more cable and new conduit paths will need to be created. Most AP s will be wired to a telecommunication room on same floor however Manhattan Building 2 and 3, and St. Albans Buildings 89 and 85_86 are exceptions requiring vertical conduit pathways- see attached drawings for details.

Conduit sleeves are required from WAP room locations to corridors. Once in corridor it is expected that cable will travel in existing cable trays. Where cable tray is not present, J-Hooks shall be utilized if existing J-Hooks have not been previously installed or are at capacity. Include pricing for supply and installation of (400) J Hooks. Turnover any unused J-Hooks to VA at end of job.

Where the cables passes through a smoke zone as seen in drawings as a corridor door, provide and install a smoke rated sleeve e.g. EZ Path 44NEZ or equal where existing sleeves don t exist. Also utilize the smoke rated sleeve for all penetrations into telecommunication rooms. Assume Qty (94) to be required, turn over any unused sleeves to VA at end of job.

3. Installation of approximately 36,000 linear feet of CAT 6A cable from APs to nearest IT rooms and terminating in a patch panel. WAP locations and IT room locations are shown on drawings.

4. Infection Control Procedures.

When removing ceiling tiles in corridors and inpatient sleeping rooms, all work must be done within mobile HEPA containment containers. Contractor will be responsible for providing , renting if needed, and transporting such containers. A minimum of two HEPA carts will be required while pulling cable.

All work will be performed during business hours, Monday thru Friday, 8 AM to 4:30 PM.

3. PERIOD OF PERFORMANCE:

3.1 Work timelines and completion progress shall be communicated to the COR for tracking purposes.Â

Â

3.2 Work described in Section 2 shall be completed within 10 weeks of NTP

4. REFERENCES:

4.1 VA OEHRM Site Infrastructure and End User Device (EUD) Requirements Version 2.0Â (Attachment 3).

4.2 Infrastructure Standard for Telecommunication Spaces Vers 3.1 https://www.cfm.va.gov/til/dguide/OIT-InfrastrucStdTelecomSpaces.pdf

5. SPECIFICATIONS:

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00 General Requirements

01 32 16.15 Project Schedule

01 33 23 Shop Drawings, Product Data, and Samples

01 35 26 Safety Requirements

01 74 19 Construction Waste Management

DIVISION 07 THERMAL AND MOISTURE PROTECTION

07 84 00 Firestopping

DIVISION 27 COMMUNICATIONS

27 05 11 Requirements for Communications Installations

27 05 33 Raceways and Boxes for Communications Systems

27 15 00 Communications Structured Cabling

6. SUBMITTALS:

The contractor shall submit the following submittals for review:

Product data and sample of conduit or raceway , smoke rated sleeves and Cat 6A cable.

As-built drawings for all data locations and labels. The Contractor shall provide the central drawing set to the Owner at the end of the project. The marked-up drawing set will accurately depict the as-built status of the system.

6. ATTACHMENTS:

6.1 Attachment 1: List of Access Point locations and site prep requirements.

6.2 Attachment 2 and 2A: NextGen WiFi Access Point location drawings

6.3 Attachment 3: VA OEHRM Site Infrastructure and End User Device (EUD) Requirements Version 2.0

6.4 Attachment 4: Sensitive Infrastructure Data Classification Memo

6.5 Attachment 5: Seasonal Influenza with Vaccines

6.6 Attachment 6: Specifications

The above paragraphs constitute a basic outline of the work to be accomplished and in no way comprises all the details for this project. Contractor shall refer to drawings and specifications for comprehensive construction requirements.

End of SOW

Update #1 ·

Page 2 of 2

CONSTRUCTION SCOPE OF WORK

EHRM NEXTGEN WIFI UPGRADES

PROJECT NO: 630-22-704

PROJECT NAME: EHRM NextGen WiFi Upgrades New York Harbor Healthcare System

1. GENERAL INTENT:

The Contractor shall furnish all labor, tools, materials and equipment to support installation of new WiFi Access Points at the Margaret Cochran Corbin VA Medical center in Manhattan 423 East 23rd St. New York, NY and at the St Albans medical center located at 179-00 Linden Blvd Queens, NY. Please note that the scope of this work is limited and specifically as listed below.

2. STATEMENT OF WORK:

Provide and install conduit, raceways, horizontal and vertical penetrations, and fire stopping to support NextGen WiFi installation at the New York Harbor healthcare system as shown and described in the project drawings and specifications. A list of required access point locations requiring conduits and/or penetrations are provided as SOW Attachment 1. SOW Attachment 2 and 2A include access point floor plans of the two medical centers.

Work shall include:

1. Installation of 180 WiFi Access Points (WAP s). WAP s will be provided by the VA, but the mounting brackets shall be provided by the Contractor. (154 access points are located at Manhattan campus and 26 at St Albans campus.)

2. Supply and Installation of 600 linear feet of EMT conduit, including junction boxes, pull cords, and fire stopping, throughout the Medical Centers. Existing conduit paths between floors/IT rooms will not have the capacity for more cable and new conduit paths will need to be created. Most AP s will be wired to a telecommunication room on same floor however Manhattan Building 2 and 3, and St. Albans Buildings 89 and 85_86 are exceptions requiring vertical conduit pathways- see attached drawings for details.

Conduit sleeves are required from WAP room locations to corridors. Once in corridor it is expected that cable will travel in existing cable trays. Where cable tray is not present, J-Hooks shall be utilized if existing J-Hooks have not been previously installed or are at capacity. Include pricing for supply and installation of (400) J Hooks. Turnover any unused J-Hooks to VA at end of job.

Where the cables passes through a smoke zone as seen in drawings as a corridor door, provide and install a smoke rated sleeve e.g. EZ Path 44NEZ or equal where existing sleeves don t exist. Also utilize the smoke rated sleeve for all penetrations into telecommunication rooms. Assume Qty (94) to be required, turn over any unused sleeves to VA at end of job.

3. Installation of approximately 36,000 linear feet of CAT 6A cable from APs to nearest IT rooms and terminating in a patch panel. WAP locations and IT room locations are shown on drawings.

4. Infection Control Procedures.

When removing ceiling tiles in corridors and inpatient sleeping rooms, all work must be done within mobile HEPA containment containers. Contractor will be responsible for providing , renting if needed, and transporting such containers. A minimum of two HEPA carts will be required while pulling cable.

All work will be performed during business hours, Monday thru Friday, 8 AM to 4:30 PM.

3. PERIOD OF PERFORMANCE:

3.1 Work timelines and completion progress shall be communicated to the COR for tracking purposes.Â

Â

3.2 Work described in Section 2 shall be completed within 10 weeks of NTP

4. REFERENCES:

4.1 VA OEHRM Site Infrastructure and End User Device (EUD) Requirements Version 2.0Â (Attachment 3).

4.2 Infrastructure Standard for Telecommunication Spaces Vers 3.1 https://www.cfm.va.gov/til/dguide/OIT-InfrastrucStdTelecomSpaces.pdf

5. SPECIFICATIONS:

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00 General Requirements

01 32 16.15 Project Schedule

01 33 23 Shop Drawings, Product Data, and Samples

01 35 26 Safety Requirements

01 74 19 Construction Waste Management

DIVISION 07 THERMAL AND MOISTURE PROTECTION

07 84 00 Firestopping

DIVISION 27 COMMUNICATIONS

27 05 11 Requirements for Communications Installations

27 05 33 Raceways and Boxes for Communications Systems

27 15 00 Communications Structured Cabling

6. SUBMITTALS:

The contractor shall submit the following submittals for review:

Product data and sample of conduit or raceway , smoke rated sleeves and Cat 6A cable.

As-built drawings for all data locations and labels. The Contractor shall provide the central drawing set to the Owner at the end of the project. The marked-up drawing set will accurately depict the as-built status of the system.

6. ATTACHMENTS:

6.1 Attachment 1: List of Access Point locations and site prep requirements.

6.2 Attachment 2 and 2A: NextGen WiFi Access Point location drawings

6.3 Attachment 3: VA OEHRM Site Infrastructure and End User Device (EUD) Requirements Version 2.0

6.4 Attachment 4: Sensitive Infrastructure Data Classification Memo

6.5 Attachment 5: Seasonal Influenza with Vaccines

6.6 Attachment 6: Specifications

The above paragraphs constitute a basic outline of the work to be accomplished and in no way comprises all the details for this project. Contractor shall refer to drawings and specifications for comprehensive construction requirements.

End of SOW

Files

File Type Posted
SAMPLE BID SHEET WiFi UPGRADE.docx DOCX document
36C24225B0017 0001.docx DOCX document
Attachment 4 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATION (1).pdf PDF
C22 ALL POSTERS.pdf PDF
S02 DRAWINGS .pdf PDF
36C24225B0017_1.docx DOCX document
WAGE-RATES.docx DOCX document
C10 VA ID PACKAGE UPDATED 12-19-2023.pdf PDF
Attachment 5 FAR 52.225-2 BUY AMERICAN CERTIFICATE.pdf PDF
ADDITIONAL INSERTS.doc DOC document
S02 SPECS .pdf PDF
Show all 11

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
7E21--NextGen Wi-Fi Upgrades Manhattan and St. Albans VAMC Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Y1DZ--Brooklyn Upgrade Life Safety/Critical Branch Electrical Distribution Construction Brooklyn, New York 11209, United States · NAICS 238210 VA Technology Acquisition Center Total Small Business
Y1DA--561-26-103 Upgrade Electrical and Plumbing in Building 18B East Orange, New Jersey 07018, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC Department of Veterans Affairs Franklin D. Roosevelt VA Medical Center Montrose, New York 10548, United States · NAICS 238210 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Building 13 Stair and Roof Replacement at Castle Point VAMC New York 12590, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Z1DA--Project # 528A6-26-607 Replace Flooring for Rm. 140 B76 | Bath VAMC NAICS 236220 Veterans Integrated Service Network 2 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors