About this opportunity
The U.S. Army Corps of Engineers Omaha District is seeking tank inspection services for three JP-8 fuel storage tanks at Eielson Air Force Base in Alaska. The solicitation requires an API internal inspection for Facility 6381 (Tank 59) and API external inspections for Facilities 6380 (Tank 61) and 1317 (Tank 100). Contractors must provide certified API 653 inspectors and NACE Level II coating inspectors to perform comprehensive tank assessments, including ultrasonic testing, coating condition surveys, and secondary containment area inspections. The evaluation will focus on technical capabilities, past performance, and pricing, with offerors required to submit a technical proposal not exceeding 5 pages, including inspector certifications and project resumes. Proposals must be submitted electronically by 2:00 PM on January 3, 2025, with questions due at least 7 calendar days before the proposal deadline.
The contract is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses under NAICS code 541990 with a $19.5 million size standard. The contract will be awarded as a firm-fixed-price agreement with a 240-day performance period, covering work at Eielson Air Force Base in Alaska (ZIP code 99702). While specific award values are not disclosed, the solicitation includes three Contract Line Items (CLINs) for the individual tank inspections. Contractors must provide all necessary equipment, materials, and personnel to complete the inspections, with deliverables including project management plans, health and safety plans, draft and final inspection reports, and teleconference briefings. The Installation will handle tank cleaning and preparation, with the contractor responsible for detailed technical inspections and comprehensive reporting.
Notice text
API Internal Inspection at Eielson AFB, AK on FAC 6381, and an API External Inspection on FAC's 6380, 1317 in accordance with all laws standards, federal regulations, as well as any state and local regulations and guidelines.