Diesel Powered Portable Skid Mounted Enclosed Generators and Maintenance
Closed Solicitation Posted
- Solicitation number
- N0040625QS563
- Agency
-
Naval Strategic Systems Programs
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Silverdale, Washington 98315, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Navy Strategic Systems Programs is seeking to procure two diesel-powered portable skid-mounted enclosed generators for the United States Coast Guard Airstation in Port Angeles, Washington. The contractor must provide complete turnkey services including removal and disposal of two existing 50kW generators, delivery and installation of two new 50kW three-phase generators with specific electrical specifications (480 VAC line voltage, 277 VAC phase voltage, 0.8 power factor), and 12 months of original equipment manufacturer maintenance. The generators must be capable of starting a 7.5 horsepower sewage lift pump motor and operating continuously for at least 12 hours, with weatherproof enclosures suitable for Pacific Northwest conditions. The solicitation requires detailed specifications and recommended OEM maintenance plans to be submitted with proposals. The submission deadline is September 3, 2025 at 5:00 PM, with a six-month delivery and installation timeline following contract award.
This opportunity is set aside for Women-Owned Small Business (WOSB) concerns under the Total Small Business designation, with a size standard and total award amount of $19,000,000. The existing generators being replaced are APTG 70 model units manufactured by Power Technique North America LLC in 2018, showing significant weathering and rust damage. The contract includes specific line items for generator procurement, disconnection and disposal services, shipping, installation, operational testing, and both monthly and annual maintenance, with an option to extend maintenance for an additional 12-month period. Work will be performed at the Coast Guard facility located at 1 Ediz Hook Road, Port Angeles, Washington, with the place of performance listed as Silverdale, WA. Contractors must be registered in the System for Award Management (SAM) and obtain base access through the Defense Biometric Identification System (DBIDS) to perform the required services.
Notice text
Diesel Powered Portable Skid Mounted Enclosed Generators
Statement of Work
Strategic Weapons Facility Pacific (SWFPAC), Code SPB14
Scope of Work: The contractor shall provide, unpack and deliver in-place two (2), enclosed Diesel Powered Portable Skid Mounted Generator-Sets with power cable connections to United States Coast Guard Airstation/SFO Port Angeles, 1 Ediz Hook Road, Port Angeles, WA 98362. Prior to delivery contractor shall remove and dispose of (2) currently installed 50kW generators. Contractor shall coordinate delivery, installation, connection and operational testing of (2) new generators with Government Point of Contact (POC). Contractor shall submit detailed specifications and recommended origninal equipment manufacturer (OEM) maintenance for proposed generators. Contractor shall provide 12 months of OEM recommended maintenance following installation and successful testing, to be performed on-site. Maintenance may be extended up to 1 time for an additional 12-month period.
Period of Performance: Once awarded, contractor will provide equipment specified by this contract within 6 (six) months from award date.
Deliverables:
Diesel Generator #1
- Rating shall be 50 kW, three phase, four-wire, 480 VAC line voltage, 277 VAC phase voltage, with a continuous power factor of 0.8.
- The load under normal conditions is approximately 18 kW. A single 7.5 horsepower three-phase sewage lift pump motor will be called upon intermittently as an addition to this normal load.
- Contractor may recommend a diesel-generator rating lower than the recommended 50 kW @ PF=0.8 is viable to avoid unnecessary 'wet-stacking' of the diesel during times when the lift pump is not operating, i.e., 18 kW.
- Contractor shall provide connection cable compatible with transfer switch in Enclosure (1).
- Diesel-generator shall be able to start sewage lift pump motor directly across the line without causing an unacceptable voltage drop to the system. The specific technical cut sheets for the sewage lift pump motor are attached as Enclosure (2).
- Diesel-generator shall have the capability to auto-start via an automatic transfer bus/switch for future capability.
- Diesel Generator #2
- Rating shall be 50 kW, three phase, four-wire, 480 VAC line voltage, 277 VAC phase voltage, with a continuous power factor of 0.8.
- The load under normal conditions is approximately 18 kW. A single 7.5 horsepower three-phase sewage lift pump motor will be called upon intermittently as an addition to this normal load.
- Contractor may recommend a diesel-generator rating lower than the recommended 50 kW @ PF=0.8 is viable to avoid unnecessary 'wet-stacking' of the diesel during times when the lift pump is not operating, i.e., 18 kW.
- Contractor shall provide connection cable compatible with transfer switch in Enclosure (1).
- Diesel-generator shall be able to start sewage lift pump motors directly across the line simultaneously without causing an unacceptable voltage drop to the system. The specific technical cut sheets for the sewage lift pump motors are attached as Enclosure (3).
- Diesel-generator shall have the capability to auto-start via an automatic transfer bus/switch for future capability.
Power Cable Connections
- Provide 2 power cables, one for each generator.
- Power cables shall be of an appropriate rating such that they can handle the full capacity of the generators.
- Cables shall be compatible with the transfer switch connection specified in Enclosure (1).
- Cables shall be at least 20 feet in length.
Equipment provided shall meet or exceed the following requirements:
- Generator shall be an all season operating system, portable diesel-generator set designed and constructed for outdoor use in the Pacific Northwest region, situated in an environment adjacent to salt-water and unshielded from all potential types of weather including windblown rain and snow. Enclosure to have drainage.
- Generator shall have a fully lockable enclosure to allow safe unattended operation.
- All aspects of their diesel-generator set including the excitation equipment, voltage regulator, and governor will perform properly under the following transient loading conditions: Assume that the diesel-generator set is supplying a steady-state load of 35 kW (44 kVA @ P.F. = 0.8) at which time the sewage lift pump induction motor (480 VAC, three-phase, 7.5 horsepower) starts directly across the line at full voltage, i.e., without soft-starting equipment.
- The generator shall be capable of running for an indefinite period of time with the 'normal' phase imbalance of Phase A=9.26 kW, Phase B=7.24 kW, Phase C=1.59 kW in addition to the lift pump motor in Enclosure (1) running and will not cause damaging negative sequence heating beyond the generator thermal capabilities.
- Generator shall have a tank capacity to support at least 12 hours of continuous, full rate operation before refueling is required.
Maintenance Description
- Maintenance shall include but it not limited to the following maintenance actions:
- Monthly operational check of at least 30 min (per OEM guidance)
- Monthly fluid level check and top off as necessary (per OEM guidance), to include:
- Fuel
- Oil
- Coolant
- Diesel Exhaust Fluid (if equipped)
- Once Annual Oil Change
- Contractor shall be responsible for providing all consumables and proper disposal of all waste.
- Maintenance shall include but it not limited to the following maintenance actions:
- Disposal
- Contractor shall dispose of currently installed generators in accordance with all applicable federal and state regulation.
Install
- Contractor will deliver generators to the site locations at the specified address.
- Contractor will place and secure the generator to the designated concrete pads.
- Contractor will make all required electrical connections for operation.
- Contractor will fill fuel and check all required fluids and fill to the OEMS specification.
Operational Test
- Contractor will coordinate with the Government POC to conduct operational load test of newly install generators.
- Contractor will provide initial operator training and (3) operation manuals.
- Contractor will run and oversee initial operation of generators during operational test.
Files
Show all 13
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Diesel Powered Portable Skid Mounted Enclosed Generators & Maintenance | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 750kW Emergency Diesel Generator (EDG) Rental (PSNS&IMF) | Naval Supply Systems Command | Total Small Business | |
| Johnston Ridge Observatory Backup Generator Repairs Gifford Pinchot National Forest | Region 6 - Pacific Northwest Region | Total Small Business | |
| Generator, alternati, in repair/modification of | Naval Supply Systems Command | No set-aside | |
| Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Non-Commercial NSN's | Land and Maritime | No set-aside | |
| Request for Information (RFI) - CONUS Generator Maintenance | Federal Emergency Management Agency | Total Small Business |