Deionization System with Recirculation and Monitoring Skid 2

Closed Solicitation Posted

Solicitation number
485281
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Oak Ridge, Tennessee 37830, United States

Notice details come from SAM.gov. Updated .

About this opportunity

UT-Battelle, LLC, the Management & Operations contractor for Oak Ridge National Laboratory, seeks proposals for a deionization system with recirculation and monitoring skid in building 7930, with proposals due August 3, 2026. This is a competitive, non-set-aside fixed-price procurement under NAICS 221310 (Water Supply and Irrigation Systems) and PSC 4610 (Water Purification Equipment).

Place of performance is Oak Ridge, Tennessee. The system must deliver one 14-inch diameter mixed-bed deionization unit processing approximately 150 ppm total dissolved solids feed water to yield approximately 3,800 gallons per 14-inch MB tank, flowing at 2 to 15 gallons per minute. The recirculation and monitoring skid includes dual 20-inch filter housings with 5-micron and 1-micron cartridges, two-channel conductivity monitors, an inline flow meter reading 0.3 to 19.8 gallons per minute with remote monitoring capability, a Click PLC control panel with MODBUS communication and cellular modem for wireless monitoring, and a stocked spare pressure pump with motor and sensors. The supplier must provide 24/7 operational support, deliver equipment and installation assistance, comply with Department of Energy Nonreactor Nuclear Facilities Division work controls (NNFD-004, Revision 11), and submit an Activity Hazard Analysis. All personnel require current Site Access Training and Environmental Management System Awareness Training, and must possess DOE security clearances per DOE Order 472.2 where applicable. Work occurs during normal hours 7:00 a.m. to 3:30 p.m. Monday through Friday, with facility badging requirements and comprehensive accident and incident reporting. The anticipated period of performance is award date through four years from award. Award will be made to the responsible offeror submitting the lowest-priced offer meeting all specified technical acceptability requirements under Lowest Price Technically Acceptable evaluation. The technical proposal is limited to 15 pages excluding resumes and must address personnel qualifications, project objectives, technical approach, methodologies, delivery schedule, facilities and resources, and supporting factors. Procurement Officer: Mckenzi Baz (865-576-6063, bazmk@ornl.gov).

Notice text

2 versions

Update #2 · Latest ·

UT-Battelle, LLC (the Company), is the Management & Operations contractor for the Oak Ridge National Laboratory (ORNL) located in Oak Ridge, TN. The Company is seeking proposals for the Deionization System with Recirculation and Monitoring Skid within building 7930 in support of a Department of Energy (DOE) funded project.
 
RFP-PR485281 - 7930 Deionization System with Recirculation and Monitoring Skid 2
Attachment A - Statement of Work - Deionization System with Recirculation and Monitoring Skid
Attachment B -  Terms and Conditions Fixed Price (10/01/2025)
Attachment C - Datasheet_THORNTON_M300_Transmitters
Attachment C - NNFD-004 Work Control
Attachment C - EH-Picomag-ELectromagnetic-Flow-Meter-Datasheet
Attachment C - Grundfis SCALA2
Attachment C - Pentek Big_Blue_Housings
Attachment D - Prime Supplemental Flowdown Document (BSD-CS-2258)-01/13/2026
Attachment E - Representations & Certifications – Abbreviated (BSD-CS-2260 dated 03/2026)
Attachment F - Activity Hazard Analysis
Attachment F - Exhibit 2 Representation of Limited Rights Data and Restricted Computer Software
Attachment G - Exhibit 9 Technical Data
Attachment G - Exhibit 17 Rights to Proposal Data Technical

Update #1 ·

UT-Battelle, LLC (the Company), is the Management & Operations contractor for the Oak Ridge National Laboratory (ORNL) located in Oak Ridge, TN. The Company is seeking proposals for the Deionization System with Recirculation and Monitoring Skid within building 7930 in support of a Department of Energy (DOE) funded project.
 
RFP-PR485281 - 7930 Deionization System with Recirculation and Monitoring Skid 2
Attachment A - Statement of Work - Deionization System with Recirculation and Monitoring Skid
Attachment B -  Terms and Conditions Fixed Price (10/01/2025)
Attachment C - NNFD-004 Work Control
Attachment C - EH-Picomag-ELectromagnetic-Flow-Meter-Datasheet
Attachment C - Grundfis SCALA2
Attachment C - Pentek Big_Blue_Housings
Attachment D - Prime Supplemental Flowdown Document (BSD-CS-2258)-01/13/2026
Attachment E - Representations & Certifications – Abbreviated (BSD-CS-2260 dated 03/2026)
Attachment F - Activity Hazard Analysis
Attachment F - Exhibit 2 Representation of Limited Rights Data and Restricted Computer Software
Attachment G - Exhibit 9 Technical Data
Attachment G - Exhibit 17 Rights to Proposal Data Technical

Files

Show all 15

Similar open opportunities

Opportunity Agency Set-aside Responses due
Maintenance and Service for Deionized (DI) Water Systems Patuxent River, Maryland 20670, United States · NAICS 811210 Naval Air Warfare Center Total Small Business
Demineralizer, water, IO NAICS 333310 Construction and Equipment Total Small Business
TriCARB Instruments Bundle or Equivalent Oak Ridge, Tennessee 37830, United States · NAICS 334516 Department of Energy No set-aside
Industrial Automation Control System Components Oak Ridge, Tennessee 37830, United States · NAICS 335313 Department of Energy No set-aside
Metal Removal Technologies-400M Oak Ridge, Tennessee 37830, United States · NAICS 333248 Department of Energy No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity